PV BREAKERS/ISOLATORS

SMART MPPT ORION-Tr SMART-1 ORION-Tr SMART-2


SOLAR ARRAY MAIN FUSES Orion Inputs
victron energy
BLUE POWER
victron energy
BLUE POWER
as close to starter battery victron energy
BLUE POWER

as possible
BMV-712 SMART COLOR CONTROL GX
BMV-712 SMART
victron energy
BLUE POWER

SmartSolar charge controller Orion-Tr Smart T


A POSITIVE T
A
Orion-Tr Smart
B
BUSBAR B

MPPT 100 | 50 12 I 12 - 30 12 I 12 - 30
BATTERY MONITOR AC Input Inverting AC Loads
victron energy victron energy
BLUE POWER

0W 45W
MAIN V 285060F 285060F
name
Non-isolated DC/DC charger 60 AMPERE
THERMAL CIRCUIT BREAKER
60 AMPERE
THERMAL CIRCUIT BREAKER Non-isolated DC/DC charger
SETUP SELECT
PV-Charger
victron energy
0 OFF 0 OFF
- +

RE

RE
75% 345W
! IP43 IP43

SE

SE
DC Power i IP43 i i

T
219W
12.8V 17.1A -75W
Battery 12/24V 50A Input I 8-17V Input I 8-17V
MCB Output I 10-15V L L Output I 10-15V

Absorbtion
PV 100Vmax 50A Power I 360W (30A)
O
A
O
A Power I 360W (30A)
D D

Float
Bulk
on/off on/off
V+
BATTERY PV IN GND OUT IN GND OUT
GND

+ - - + L H + - + L H + - +
color control

The SmartBatteryProtect must be


programmed for Li-Ion mode-C and 12 Volt

VE-direct
ORION-2 H-CONTACT
either through programming on the device VRM
itself or with a Bluetooth enabled WORLD
There are several configuration options

VE-direct-2

VE-direct-1

VE.Bus

ETHERNET
smartphone or tablet. possible. Read the Orion-Tr manual carefully
Connect the load disconnect output of the and choose the one fitting your installation.
VE.Bus BMS to Remote H terminal.
CCGX POWER + MAIN DC
REMOTE PANEL DISTRIBUTION FROM MultiPlus
VE.Bus MAINS DETECTOR MultiPlus VE.Bus MAINS DETECTOR MultiPlus
SMART BATTERY PROTECT 220 FROM MPPT
POSITIVE
BUSBAR
MAIN SWITCH-2
VE.Bus BMS MEGA
xxxA Load 1 +
The VE.Bus BMS is enlarged
visible in this drawing. OFF
The BMS GND is not connected MEGA
ORION-1 H-CONTACT MAIN SWITCH-3
to prevent ground loops. xxxA Load 2 +
OFF
Ground comes through the
ALTERNATOR STARTER-MOTOR Charge light Blue Smart
VE.Bus UTP cable. Charger 12V-5A
MEGA FROM ALTERNATOR D+
ON xxxA Load 3 + 1
CCGX 1A
A
FUSE m ON
CCGX POWER + AMI IGNITION
175A
5x20mm FUSE
FUSE MEGA xx AMP.
xxxA Load 4 + INTERNAL
30 15
ALTERNATOR
FUSE 50 12V Charger
10A FUSE
MEGA
xxxA Load 5 + B- D+ B+
30 FROM STARTER+(30)
ENGINE SYSTEM
Starter Battery
IP-65 | waterproof
CYRIX Li CHARGE 230 POSITIVE
BMS ON/OFF BUSBAR STARTER
MOTOR
31 AGM 12-125 S

THERMAL CIRCUIT BREAKER


BMS POWER+ ALTERNATOR AGM Super Cycle Battery
BMS LOAD DISCONNECT
12V-150A

60 AMPERE
NEG. POS.

285060F
A
B
T
BMS CHARGE DISCONNECT

D
A
L
li-ion
M8 CIRCULAR CYRIX Li recondition
CONNECTORS
SE
T MPPT + high [14.7V]
ALARM LED - CHARGE RE normal [14.4V]

Li-DISTRIBUTION 230 Charger mode


Batt. victron energy

THERMAL CIRCUIT BREAKER


BLUE POWER

60 AMPERE
POSITIVE

285060F
ALARM LED + blue smart

A
B
T

D
A
L
BUSBAR ORION 1 + BMV-B2 / 100mA FUSE
charger
ET
Maximum 5mA S 12V 5A
RE
Starter Battery +
BTV CABLE

BTV CABLE

THERMAL CIRCUIT BREAKER


MultiPlus / 3KW/12V/120V-60Hz AC

60 AMPERE
285060F
victron energy

A
B
T
B L U E P O W E R

D
A
L
MAIN SWITCH-1 T ORION 2 +
INVERTER/CHARGER
SE
ANL RE
OFF
300A Shore power Generator power
MultiPlus Batt + MAIN INCOMING
AC BREAKERS
KEEP POSITIVE BATTERY CABLES Battery Pre Main Fuses ON MEGA TOWARDS
400A
ALL AS SHORT AS POSSIBLE AND ISOLATION TRANSFORMER
MultiPlus
ALL AT THE SAME LENGTH ! MultiPlus Batt +
OR GALVANIC ISOLATOR
SHOULD BE INSERTED
ANL HERE IF NEEDED.
INCLUDING NECESSARY
BREAKERS.
300A www.victronenergy.com

victron energy
BLUE POWER

BMS 2A charger inverter


mains on inverter on
I on
BMV 100mA AC in 1 AC out 1
bulk
O off
overload
AC out 2
absorption low battery
Spare xxA float
charger only
temperature 0
Shore Gen
50A
2 x Lithium
.battery charger .sinewave inverter .transfer switch name name
5x20mm Battery
.powerassist .parallel .three phase 125/250V
FUSES connectable Easy Lock
0 OFF 0 OFF 0 OFF 0 OFF
MultiPlus
12.8V-200Ah AC transfer capacity: 50A | Inverter 120V CE

VOLT
12 |3000 |120

AMP
VA
VE.Bus-1 VE.Bus-2
MCB MCB
Smart LiFePO4 BMV POWER + BATTERY

BTV CABLE BATTERY SHORE POWER

victron energy
BLUE POWER
CONNECTION

Mains detector
_ _

NOT IN USE
BTV CABLE

VE.Bus BMS
L IN N IN G L OUT-1 N OUT-1 G L OUT-2 N BATTERY
+ + 120V/60Hz AC Shore Generator
BATTERY power power
M8 CIRCULAR

NEUTRAL

NEUTRAL

NEUTRAL
GROUND

GROUND
LINE

LINE

LINE
M8 CIRCULAR CONNECTOR M8 CIRCULAR AC IN-1 AC OUT-1 AC OUT-2 ON

CONNECTOR CONNECTOR +
T-SENSE
- +
AUX1
- +
AUX2
- +
GND
-
1

S1 S2
2

+
TRICKLE
NC NO COM
K1
NC NO COM
K2
+ -
V-SENSE
RELAY CHARGE

CENTRAL
NEGATIVE BUSBAR VE.Bus to CCGX VE.Bus BMS mains
detector inside MultiPlus
MultiPlus AC IN-1
CYRIX LI-
MultiPlus AC OUT-1
BP220 GND-
12.8V-200Ah

12.8V-200Ah

CCGX- VE.Bus mains detector to BMS


Smart LiFePO4

Smart LiFePO4

MultiPlus AC OUT-2
Lithium

Lithium

Load 1 -
Drawing BJE-276A AC DISTRIBUTION
victron energy

victron energy

Load 2 -
from MultiPlus
BLUE POWER

BLUE POWER

Load 3 - AC Out-1 & AC Out-2 GENERATOR 4KW


Load 4 - Conn-G Batt+ 120V/60Hz AC

Load 5 - Conn-G Batt+


MPPT-
Engine- name :hager :hager name :hager :hager

MultiPlus Batt- Conn-F Batt- 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF 0 OFF

MultiPlus Batt- Conn-F Batt- MCB MCB


MultiPlus Case Ground Conn-L Case ground

SUPPLIED UTP CABLE MultiPlus MultiPlus


AC out-2 AC out-1

+B2 Starter Battery +


+B1

BMV-712 Smart
120V Switched load-1
THE BMV SHUNT CAN BE UPGRADED 120V Switched load-2
KEEP NEGATIVE BATTERY CABLES FROM STANDARD 500A TO 1000A. 120V No Break load-1
ALL AS SHORT AS POSSIBLE AND THE BMV SHUNT IS MOUNTED 120V No Break load-2
ALL AT THE SAME LENGTH ! DIRECT ON BOTH BUSBARS.
Blue Smart charger

IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION !
When operating in inverter mode, the Neutral output of Recommended AC Out-1 cable/breaker size MultiPlus Recommended AC Out-2 cable/breaker size MultiPlus Recommended DC cable/fuse size MultiPlus Recommended AC IN WARNING
a inverter/charger must be connected to ground to cable/breaker size MultiPlus
With Power assist the MultiPlus can add AC Out-2 only is available when power is 0-5 m cable length: 4 x 50SQmm, 5-10 m cable 120 VOLT AC IS EXTREMELY
guarantee proper functioning of a GFCI or RCD device. 3KW to the output load when needed. present on AC IN. During battery operation length: 4 x 70SQmm. When used in closed AC IN must be protected by a circuit HAZARDOUS !!!
In case of a split phase supply the Neutral also must Together with the adjustable 50A input this it will be disconnected. conduits, cable size should double. Cable length breaker rated at 50A max or less. This DO NOT TOUCH ANY LIVE WIRED
Drawing BJE-276A be grounded. all adds up to the max sum of input and AC Out-2 supports up to 25A. stands for the distance between the battery and the depends heavily on the size of the PARTS OF THE INSTALLATION !!!
output current of 50+25=75A. An Earth An Earth leakage device with breaker or a MultiPlus connections !!! Recommendations are connected power source.The input current WHEN IN DOUBT, ALWAYS CONSULT
The primary Case ground connection from a inverter must be adjusted to fit the size of the
leakage device with breaker or a combination MCB/RCD must be installed without other loads in the system and these also YOUR VICTRON DEALER !!!
charger like a Multi or a Quattro, must be connected to combination MCB/RCD must be installed on the output. Cable size must be adjusted should be taken into account for proper main connected power source.
the Central Negative Busbar of the DC system. Size of on the output. Cable size must be adjusted accordingly. battery, main fuse & main switch cables !!! The breaker and cable size for AC IN
this cable must be identical to connected DC negative. accordingly. Fuse size should be 400A. should be adjusted accordingly.