You are on page 1of 2

RX FINAL NA

REX DREAM HOUSE · Story 1 · Main Comfort Room (Main Comfort Room Light Scene 1)
Summary

Ground area: 31.83 m² | Reflection factors: Ceiling: 70.0 %, Walls: 27.5 %, Floor: 59.3 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.370 m - 3.700 m | Mounting height: 3.415 m - 3.457 m 1
RX FINAL NA

REX DREAM HOUSE · Story 1 · Main Comfort Room (Main Comfort Room Light Scene 1)
Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 45.4 lx ≥ 150 lx WP8

g1 0.006 - - WP8

Consumption values Consumption 110 kWh/a max. 1150 kWh/a

Room Lighting power density 0.91 W/m² - -

2.01 W/m²/100 lx - -

Utilization profile: General areas inside buildings - Rest, sanitation and first aid rooms, Canteens, pantries

Luminaire list

pcs. Manufacturer Article No. Article name P Φ Luminous efficacy

1 SYLVANIA 3033931 Insaver HO Topper LED II 150 RO 12W NW 12.1 W 1134 lm 93.7 lm/W

1 SYLVANIA 3098113 + Insaver LED II 150 Low Output NW DALI 17.0 W 1746 lm 102.7 lm/W
3098128 E3 + UGR19 accessory
17.0 W 118 lm (100 %) -