KS_PN_1

Building 1 · Story 1 · Room 2 (Light scene 1)


Summary

Ground area: 22.23 m² | Reflection factors: Ceiling: 66.1 %, Walls: 46.4 %, Floor: 73.3 % | Light loss factor: 0.80 (fixed) | Clearance
height: 2.670 m | Mounting height: 0.900 m - 3.078 m 1
KS_PN_1

Building 1 · Story 1 · Room 2 (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 235 lx ≥ 100 lx WP2

g1 0.001 - - WP2

Consumption values Consumption 1100 kWh/a max. 800 kWh/a

Room Lighting power density 25.64 W/m² - -

10.93 W/m²/100 lx - -

Utilization profile: General areas inside buildings - Rest, sanitation and first aid rooms, Rest rooms

Luminaire list

pcs. Manufacturer Article No. Article name P Φ Luminous efficacy

2 MPE LBL-7V LED bulb 7W 2800K 7.0 W 764 lm 109.2 lm/W

8 MPE LBL-7V LED bulb 7W 2800K 7.0 W 764 lm 109.2 lm/W

6 Philips DN561B 1xLED8S/840 F PG 8.0 W 760 lm 95.0 lm/W

1 SLV 1000730 ENOLA B 4.0 W 270 lm 67.6 lm/W

8 Targetti 1V7335 SLIM LINE 56.0 W 2798 lm 50.0 lm/W