You are on page 1of 2

fisbang

Site 1 · Building 1 · Storey 1 · Master Bedroom (ARTIFICIAL)


Summary

Ground area 57.84 m² Clearance height 2.500 m – 3.000 m

Reflection factors Ceiling: 67.2 %, Mounting height 0.700 m – 3.000 m


Walls: 34.1 %,
Floor: 33.9 % Height Working plane 1.000 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.000 m

1
fisbang

Site 1 · Building 1 · Storey 1 · Master Bedroom (ARTIFICIAL)


Summary

Results

Symbol Calculated Target Check Index

Daylight D 0.736 % – DF1

Working plane Ēperpendicular 254 lx ≥ 250 lx WP1

Ē/E min 876 ≤ 3.00 WP1

Glare valuation(1) RUG, max 28 ≤ 22

Energy estimation(2) Consumption [293.08 - 369.99] kWh/a max. 2050 kWh/a

Room Lighting power density 3.32 W/m² –

1.31 W/m²/100 lx –

(1) Based on a rectangular space of 8.920 m x 6.484 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: 33 - LIGHTING FOR RESIDENCES (Residental Interiors; Bedrooms, Television Viewing)

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

2 BRIGHT LED-LAMP PENNA 3 TABLE – 14.0 W 1521 lm 108.6 lm/W


SPECIAL
LIGHTING S.A.

1 LEDS C4 S.A. 10-3273-2 Queen 28 7.0 W 284 lm 40.5 lm/W


1-05

3 Philips PT320T 1 xLED39S/PW930 MB 17 36.0 W 3857 lm 107.1 lm/W

4 Philips RS150B LED12S/840 WB D78 PSR 20 12.3 W 1322 lm 107.5 lm/W