Professional Documents
Culture Documents
Industrielaan 17b, 2250 Olen, Belgium The present document and its contents remain the property
of OTN Systems NV and shall not, without prior written
Tel: +32 14 25 28 47 consent, be copied or transmitted or communicated to third
Fax: +32 14 25 20 23 parties, nor be used for any other purpose than such as
E-mail: info@otnsystems.com underlies their delivery to the addressee.
www.otnsystems.com
The present document and its contents may change in the
Ref. No.: Edition 1 course of time or may not be suitable in a specific situation.
Issued: March 2022 Consequently, they are recommended as suggested
guideline only.
Specifications subject to change as design im-
provements are implemented. OTN Systems NV hereby disclaims any liability for any dam-
©2022 OTN Systems NV - All rights reserved. ages that may result from the use of the present document
unless it is used with respect to the operation and mainte-
nance of equipment originally manufactured by
OTN Systems NV and covered by its standard warranty.
Page 2 of 17 Edition 1
eXcellence in TRANsport XTran Release Notes
1. INTRODUCTION
This page documents new features, enhancements and changes included in this XTran
release. For detailed information on using any of XTran features, please refer to the user
manuals.
2. RELEASE DATE
XTran R4.7.2 has been released on March 2th , 2022.
3. REQUIREMENTS
The XTran products in XTran Release R4.7.2 require the following hardware editions and
firmware versions. For ETS releases, refer to the ETS release notes.
XT-2215-A Core Node with dual PSU position, dual 1 Not Applicable Not Applicable
CSM position and 15 interface module
positions
XT-2210-A Aggregation Node with dual PSU 1 Not Applicable Not Applicable
position, dual CSM position and 10
interface module positions
XT-2209-A Aggregation Node with dual PSU 1 Not Applicable Not Applicable
position, dual CSM position, 9 interface
module positions and optimized 9-L3A-L
support
XT-2206-A Aggregation Node with dual PSU 1 Not Applicable Not Applicable
position, dual CSM position and 6
interface module positions
XT-1104-A Aggregation Node with single PSU 1 Not Applicable Not Applicable
position, single CSM position and 4
interface module positions
16 6.17.13.83_macsec
Capable
Edition 1 Page 3 of 17
XTran Release Notes eXcellence in TRANsport
16 6.17.13.83_macsec
Capable
5 1.14.13.81_macsec
Capable
NSM-A Node Support Module with PoE support 3 Not Applicable Not Applicable
Page 4 of 17 Edition 1
eXcellence in TRANsport XTran Release Notes
4.19 TXCare_SupportPack_<TXCare-VERSION>.exe
Edition 1 Page 5 of 17
XTran Release Notes eXcellence in TRANsport
4. IMPORTANT REMARK
• MAC Security feature on the 4-GC-LW, 4-GCB-LW and 4-GO-LW requires “macsec-
Capable” image.
5. CHANGES IN R4.7.2
Page 6 of 17 Edition 1
eXcellence in TRANsport XTran Release Notes
8. RESTRICTIONS/KNOWN ISSUES
• At startup of the node connected directly to TXCare, the node can report an 'NTP
unreachable' problem if TXCare is configured as NTP server for this node. The node is
not able to connect to the NTP server. This alarm will disappear automatically after 1
hour maximum and the date/time on the node will be synchronized.
• Links between 1-10G-LW modules should have the same PHY mode configuration on
both sides, if the PHY mode differs the link does not come up.
• If the clock settings of a synchronous RS232 port are changed from internal to
adaptive and back to internal clock it is possible that bit errors occur in the serial data
traffic. Rebooting the 7-SERIAL interface module or interrupting the WAN link for a
short time will restore the service.
• When creating an Ethernet service on a 1-10G-LW interface port with a high
bandwidth (typical more than 4 Gbit/s), the default burst size may be too low,
depending on the traffic behavior of the connected devices. This can lead to traffic
loss in the network. The burst size can be changed when creating the service or
modifying the service.
• Connecting a remote TXCare client to the module in the second CSM slot (CSM-2) can
result in communication loss between the remote TXCare client and TXCare server.
Connect a remote TXCare client to CSM-1 if possible.
• The following fields only allow alphanumeric character sets (a-z, A-Z, 0-9, <space>, _,
-): name of tunnels and services, PoE description field.
• IEEE1588v2 is supported on 4-GC-LW, 4-GCB-LW, 4-GO-LW, 1-10G-LW (full-duplex
ports) with following restrictions:
o Only Ethernet encapsulation on Port 1 and 2 of 4-GC-LW, 4-GCB-LW, 4-GO-LW
o Any change in link down/up, configuration, or CSM switchover, results in an
automatic reset of IEEE1588v2.
o Bit errors can result in corrupt IEEE1588v2 packets causing faulty IEEE1588v2
handling. In that case, reset IEEE1588v2 in the port properties of TXCare Network
Hardware. Traffic will be interrupted for respectively 10 seconds maximum on 4-
GC-LW, 4-GCB-LW, 4-GO-LW and 1 second on a 1-10G-LW IFM.
• In very rare cases, a 10G link (1-10G-LW) can generate “remote alarm” with no data
being sent after a module reboot or port enable/disable. Workaround: reboot the
module again.
• Fast Ethernet is not supported on the 4-GO(C)-L modules in a 10G slot.
• CSM switch over times are increased since MACSec functionality is added.
• When a 4-GC-LW or 4-GO-LW module is running an R4.3.3 image, while the CSM 540
has an image < R4.3.3, and no-negotiation is configured on one of the IFM ports, then
the CSM 540 keeps on booting.
• Connecting external ETS devices to XTran requires fixed port settings on both sides.
Correct speed and duplex setting are required on the optical ports.
Edition 1 Page 7 of 17
XTran Release Notes eXcellence in TRANsport
• Limitations for IFM type versus slot compatibility in the XT-2215-A chassis.
o 1-10G-LW and 1-40G-LW: only allowed in slots 6/7/8/9 (slots around the
CSMs)
o All other modules are only allowed in slots 1-5,10-15.
• Regarding IFM compatibility in XT-2215-A nodes:
o In some cases, it is possible that an IFM that is inserted in the node or
configured via TXCare, is not taken into service because the slot has been
used previously in a manner that is not compatible with the IFM. In such a
case an alarm is raised: "Current hardware setting not compatible for
Measured Interface Module IFM-<slot>”.
o Possible solutions are to reboot the node or to insert and configure the IFM in
another slot in order to enable the ports and allow load actions.”
• Issues noticed if using Fast Ethernet SFP modules on port of 4-GO-LW and 4-GC(B)-
LW.
• Combining MACSEC functionality with IEEE1588 timestamping on the same port is
currently not working for the of 4-GO-LW and 4-GC(B)-LW module.
• IEEE1588 timestamping is not supported on the 1-40G-LW (S30924-Q218-X101) and
4-10G-LW (S30924-Q219-X101) modules.
9. ADVISABLE GUIDELINES
OTN SYSTEMS ensures backwards compatibility with previous MySQL version 5.6, but
strongly recommends the migration to MySQL 8.0 for security reasons. To know more about
MySQL 8.0 security enhancements, please visit:
https://dev.mysql.com/doc/refman/8.0/en/mysql-nutshell.html
Page 8 of 17 Edition 1
eXcellence in TRANsport XTran Release Notes
CSMxx0x-A XTD-2110-A
XTR-2124-A(F)
Area Parameter Reached Unit Reached Unit
Level Level
Services Terminating unprotected services 128 (1) node 64 (1) node
Logical Ring Logical ring size (nodes that terminate service) 60 local ring 60 local ring
LPS 1:1 LPS instances on one node that have switchover < 50ms 8 node 8 node
7-SERIAL Slaves supported for Serial Ethernet PTMP 156 service 156 service
Edition 1 Page 9 of 17
XTran Release Notes eXcellence in TRANsport
u IFMs or Node
8-FXS 4-2/4WEM, 4-CODIR, 4-E1-L/4-T1-L, Ethernet IFMs: Layer2 IFMs: Layer3 IFMs: Access Node:
4-CONTRA, 16-E1-L/16-T1-L, 4-GC-LW, 4-GCB-LW, 6-GE-L, 9-L3A-L XTD-2110-A
(6-SERIAL = Future 2-C37.94,4-C37.94 4-GO-LW, 1-10G-LW, 6-GEP-L, 9-L3EA-L XTR-2124-
support), 4-10G-LW, 1-40G-LW 16-GEP-L A(F)
7-SERIAL, 2-OLS,
4-DSL-LW
Backbone MPLS-TP Network
WAN Ports --- --- --- Yes --- --- Yes
MACsec on 1 Gbps / 10 Gbps --- --- --- Yes: --- --- ---
WAN Ports
1-10G-LW in Aggregation Node:
Min. PHY Ed. 1
1-10G-LW in Aggregation Node:
Min. PHY Ed. 1
4-10G-LW: Min. HW Ed. 10
Synchronisation
Page 10 of 17 Edition 1
eXcellence in TRANsport XTran Release Notes
u IFMs or Node
8-FXS 4-2/4WEM, 4-CODIR, 4-E1-L/4-T1-L, Ethernet IFMs: Layer2 IFMs: Layer3 IFMs: Access Node:
4-CONTRA, 16-E1-L/16-T1-L, 4-GC-LW, 4-GCB-LW, 6-GE-L, 9-L3A-L XTD-2110-A
(6-SERIAL = Future 2-C37.94,4-C37.94 4-GO-LW, 1-10G-LW, 6-GEP-L, 9-L3EA-L XTR-2124-
support), 4-10G-LW, 1-40G-LW 16-GEP-L A(F)
7-SERIAL, 2-OLS,
4-DSL-LW
SyncE --- Yes on 2-OLS E1 ports Yes: on E1/T1 ports Yes: --- --- ---
No: on C37.94 ports Member: all IFMs, all ports
Recovery: all IFMs, all ports except
port 2,3,4 on 4-10G-LW
PTP IEEE 1588v2 --- --- --- Yes: as Transparent Clock, not as --- --- ---
Grandmaster, Boundary clock nor
Ordinary Clock (not for 4-10G-LW,
1-40G-LW)
Hardware
LAG + LACP --- --- --- In Aggregation Nodes: Yes Yes ---
(Only LAN ports) LAG: Yes / LACP: No
In Core Nodes:
LAG: No / LACP: No
PoE --- --- --- Yes, on 4-GC-LW Yes on 6-GEP-L --- Yes
(ports[1..4]), 16-
GEP-L
Smart SFP --- --- --- Yes on 4-GO-LW ports or --- --- ---
4-GC-LW/4-GCB-LW front port 1
(not for 4-10G-LW, 1-40G-LW)
Services
Ethernet Yes Yes on 4-DSL-LW --- Yes Yes Yes Yes
Ethernet: Local Service --- --- --- --- Yes Yes Yes on L2/L3
XTD:ports[5..10
Edition 1 Page 11 of 17
XTran Release Notes eXcellence in TRANsport
u IFMs or Node
8-FXS 4-2/4WEM, 4-CODIR, 4-E1-L/4-T1-L, Ethernet IFMs: Layer2 IFMs: Layer3 IFMs: Access Node:
4-CONTRA, 16-E1-L/16-T1-L, 4-GC-LW, 4-GCB-LW, 6-GE-L, 9-L3A-L XTD-2110-A
(6-SERIAL = Future 2-C37.94,4-C37.94 4-GO-LW, 1-10G-LW, 6-GEP-L, 9-L3EA-L XTR-2124-
support), 4-10G-LW, 1-40G-LW 16-GEP-L A(F)
7-SERIAL, 2-OLS,
4-DSL-LW
]
XTR:ports[5..24
]
Circuit Emulation --- Yes (except for Yes --- --- --- ---
4-DSL-LW)
Serial Ethernet --- Yes on 7-SERIAL --- --- --- --- ---
(6-SERIAL = future
support)
Serial Port Server --- (6-SERIAL = future --- --- --- --- ---
(future support) support)
Voice Yes (analog --- --- Yes (VoIP) Yes (VoIP) Yes (VoIP) ---
Voice)
Local Mode --- Yes on 2-OLS Yes on E1 ports of the --- --- --- ---
2-C37.94
Transparent SDH-SONET --- --- --- Yes on 4-GO-LW ports or --- --- ---
(TSoP Smart SFP) for 4-GC-LW/4-GCB-LW front port 1.
STM-1/STM-4/OC-3/OC-12 Required: TSoP Port Modules
Channelized SDH --- --- Yes on 16-E1-L Yes on 4-GO-LW ports or --- --- ---
(CSoP Smart SFP) for STM-1 4-GC-LW/4-GCB-LW front port 1
Required: CSoP Port Modules
Page 12 of 17 Edition 1
eXcellence in TRANsport XTran Release Notes
u IFMs or Node
8-FXS 4-2/4WEM, 4-CODIR, 4-E1-L/4-T1-L, Ethernet IFMs: Layer2 IFMs: Layer3 IFMs: Access Node:
4-CONTRA, 16-E1-L/16-T1-L, 4-GC-LW, 4-GCB-LW, 6-GE-L, 9-L3A-L XTD-2110-A
(6-SERIAL = Future 2-C37.94,4-C37.94 4-GO-LW, 1-10G-LW, 6-GEP-L, 9-L3EA-L XTR-2124-
support), 4-10G-LW, 1-40G-LW 16-GEP-L A(F)
7-SERIAL, 2-OLS,
4-DSL-LW
and this ring is connected to a port
based Ethernet service.
RGERP --- --- --- MAC flush on topology change, MAC flush on MAC flush on ---
immediate switchover. Port based topology change, topology change,
and VLAN based services. immediate immediate
switchover. Port switchover. Port
based and VLAN based and VLAN
based services. based services.
MRP --- --- --- MAC flush on topology change, MAC flush on MAC flush on ----
immediate switchover. Port based topology change, topology change,
and VLAN based services. immediate immediate
switchover. Port switchover. Port
based and VLAN based and VLAN
based services. based services.
Layer2
LLDP --- --- --- Yes Yes Yes ---
IGMP Snooping --- --- --- --- Yes, MAC based Yes, IP based ---
MSTP --- --- --- MAC flush on topology change: Yes: Port based Yes: Port based ---
Port based service: Network wide service: Network service: Network
VLAN based service: No MAC flush wide; VLAN based wide; VLAN based
service: Local in service: Local in
Node Node
Layer3
Edition 1 Page 13 of 17
XTran Release Notes eXcellence in TRANsport
u IFMs or Node
8-FXS 4-2/4WEM, 4-CODIR, 4-E1-L/4-T1-L, Ethernet IFMs: Layer2 IFMs: Layer3 IFMs: Access Node:
4-CONTRA, 16-E1-L/16-T1-L, 4-GC-LW, 4-GCB-LW, 6-GE-L, 9-L3A-L XTD-2110-A
(6-SERIAL = Future 2-C37.94,4-C37.94 4-GO-LW, 1-10G-LW, 6-GEP-L, 9-L3EA-L XTR-2124-
support), 4-10G-LW, 1-40G-LW 16-GEP-L A(F)
7-SERIAL, 2-OLS,
4-DSL-LW
Virtual Router --- --- --- --- --- Yes ---
Ethernet: E-Tree --- --- --- Yes on LAN ports Yes, only back end Yes, only back end Ports[1..4] in
ports ports LAN mode
Storm Control --- --- --- Yes, Port Properties Yes, Port Yes, Port Properties Yes, Port
Properties Properties
BPDU Guard --- --- --- Yes, Port Properties Yes, included in Yes, included in Ports[1..4]: yes
Layer2 MSTP Layer2 MSTP Wizard Ports[5..10]: no
Wizard
IP ACL --- --- --- Yes (max. 1 rule) Yes Yes (max. 128 rules) Yes
(max. 128 rules) (max. 1 rule for
Page 14 of 17 Edition 1
eXcellence in TRANsport XTran Release Notes
u IFMs or Node
8-FXS 4-2/4WEM, 4-CODIR, 4-E1-L/4-T1-L, Ethernet IFMs: Layer2 IFMs: Layer3 IFMs: Access Node:
4-CONTRA, 16-E1-L/16-T1-L, 4-GC-LW, 4-GCB-LW, 6-GE-L, 9-L3A-L XTD-2110-A
(6-SERIAL = Future 2-C37.94,4-C37.94 4-GO-LW, 1-10G-LW, 6-GEP-L, 9-L3EA-L XTR-2124-
support), 4-10G-LW, 1-40G-LW 16-GEP-L A(F)
7-SERIAL, 2-OLS,
4-DSL-LW
ports[1..4],
max. 128 rules
for L2/L3 ports)
MAC ACL --- --- --- Yes (max. 1 rule) Yes (max. 128 Yes (max. 128 rules) Yes
rules)
Sticky MAC Yes --- --- Yes Yes (Back End Yes (Back End Ports) L2/L3 ports:Yes
Ports) on backend
ports
Ports[1..4]:yes
MAC Limit Yes --- --- Yes (not for 4-10G-LW, Yes Yes Yes
(In Aggregation Node/ Access 1-40G-LW)
Nodes)
Static MAC Table Yes --- --- Yes Yes (Back End Yes (Back End Ports) L2/L3 ports:Yes
Ports) on backend
ports
Ports[1..4]:yes
Loss Measurement (LM) Yes Yes Yes Yes (not for 4-10G-LW, --- --- Yes
(In Aggregation/Access Nodes) 1-40G-LW)
Delay Measurement (DM) Yes Yes Yes Yes (not for 4-10G-LW, --- --- Yes
(In Aggregation/Access Nodes) 1-40G-LW)
Edition 1 Page 15 of 17
XTran Release Notes eXcellence in TRANsport
u IFMs or Node
8-FXS 4-2/4WEM, 4-CODIR, 4-E1-L/4-T1-L, Ethernet IFMs: Layer2 IFMs: Layer3 IFMs: Access Node:
4-CONTRA, 16-E1-L/16-T1-L, 4-GC-LW, 4-GCB-LW, 6-GE-L, 9-L3A-L XTD-2110-A
(6-SERIAL = Future 2-C37.94,4-C37.94 4-GO-LW, 1-10G-LW, 6-GEP-L, 9-L3EA-L XTR-2124-
support), 4-10G-LW, 1-40G-LW 16-GEP-L A(F)
7-SERIAL, 2-OLS,
4-DSL-LW
Tunnel Ping Yes Yes Yes Yes --- --- Yes
Port Mirroring Yes, intra node: Yes, intra node: can only Yes, intra node: can only Yes, intra node: source can be any Yes, same IFM: Yes: source and Yes
can only be a be a source, can be be a source, can be IFM except L3 IFM, destination: source and destination can be a
source, can be mirrored to Ethernet mirrored to Ethernet Ethernet IFMs destination must mix of main and
mirrored to IFMs IFMs be same L2 IFM extension L3 IFM
Ethernet IFMs
MAC Monitor Yes (Node level) Yes on 7-SERIAL (Node --- Yes Yes Yes Yes
level) (6-SERIAL = future)
Page 16 of 17 Edition 1
eXcellence in TRANsport XTran Release Notes
Edition 1 Page 17 of 17