Performance curve

Pump unit: CD 400-1040 I1 Speed: 973 1/min Impeller: 1020 mm


Quotation no.: 5477-5313-22 Position: P01 Date: 2022-06-29
Medium: Water Density: 1000 kg/m³ Viscosity: 1 mm²/s
Flow Head Efficiency Power NPSH
3500.0 m³/h 145.0 m 80.0 % 1728.7 kW 7.1 m
Water parameters: 3500.0 m³/h 145.0 m 80.0 % 1725.6 kW -
Unless otherwise specified in the contract, pump acceptance tests are performed in accordance with ISO 9906 IIB, water 20 ° C.
For calculation will be use these viscosity correction factors:
cQ 1 cH 1 ch 1
H/m Head — Ø 1020 (973.1 1/min) ∆p / kPa

1800
180
1700
170
1600
160
1500
150
145 80% 1422
1400
140
A1
130 1300

120 1200

110 1100

100 1000

90 900

80 800

70 700

60 600

50 500

40 400

30 300

20 200

10 100

0 0
P₂ / kW Shaft power P2
1800
1729
1600

1400

1200

1000

800
NPSH₃ / m NPSH3

7.1
7

5
η /80
% Hydraulic efficiency

70
60
50
40
30
20
10
0
0 400 800 1200 1600 2000 2400 2800 3200 3500
3600 4000 4400 4800 Q / m³/h

NPSH values below 1m are expected, not guaranteed as they cannot be measured during performance test Curve no.: 980-0301-202012