You are on page 1of 2

AVOCENT® UNIVERSAL

MANAGEMENT GATEWAY APPLIANCE


Universal Management IQ Module
Quick Installation Guide
UMIQ Module Configuration

NOTE: UMIQ modules are available connected to a 5V DC power the back of the appliance and
with single or dual ports. supply. See the Safety, EMC and the other end into the module’s
Environmental Approvals and RJ45 connector. For modules
ABOUT THE UMIQ MODULE Markings section for more with two RJ45 ports, the other
The UMIQ module converts information. port can be used to connect to
keyboard, video and mouse (KVM) a dedicated service processor.
NOTE: A patch panel is not
and smart card signals from a target NOTE: Maximum cable length
recommended as a connection
to digital IP data, enabling is 100 meters.
point between the appliance and
bi-directional control of the attached
an IQ module because it can cause 3. Turning on the target
target by a remote user.
distance, power or video quality system
The module draws its operating control feature issues. If the issues Ensure the target is turned on
power from the connected server are still present when the patch before attempting to establish a
over USB. The Avocent® Universal panel is removed, contact remote KVM session.
Management Gateway appliance Technical Support.
provides stand-by power over the 4. Updating the initial
CAT5 cable, which keeps the module 1. Connecting a target firmware
in a suspended state. It is important device to the module When connecting the module
that networking equipment is never Plug the module, DB15 (VGA) to an appliance for the first
used in the connection path and USB connectors into the time, the module will
between the appliance and the appropriate target ports. automatically receive a
module since stand-by power will Repeat this procedure with firmware update. Ensure the
damage networking devices additional modules for each module remains connected
(switches/routers/firewalls). target that is to be connected until the update is complete.
NOTE: Stand-by power is not to the appliance.
compatible with Power over 2. Connecting the module
Ethernet (PoE) devices. to your appliance
There is an external DC power Connect one end of a CAT5
cable option available which can be cable into an available port on

590-1533-501F 1
UMIQ MODULE
Universal Management IQ Module

UMIQ-E Module with the instruction manual, may SAFETY, EMC AND
The UMIQ-E (Enhanced) module is cause harmful interference to radio ENVIRONMENTAL
a new operating mode that enables communications. Operation of this APPROVALS AND
the module to be connected to a equipment in a residential area is MARKINGS
Universal Management Gateway likely to cause harmful interference Safety certifications and EMC
appliance through the GB1 (eth0) in which case the user will be certifications for this product are
or GB2 (eth1) ports. Once a network required to correct the interference obtained under one or more of the
connection is made, the appliance at his own expense. following designations: CMN
can be accessed through your (Certification Model Number), MPN
Canada
intranet. See the Avocent® (Manufacturer’s Part Number) or
This Class A digital apparatus
Universal Management Gateway Sales Level Model designation.
complies with the Canadian
Appliance Installer/User Guide for Designations that are referenced in
ICES-003.
more information on converting the EMC and/or safety reports and
and configuring the UMIQ-E Cet appareil numérique de la classe certificates are printed on the label
module. A est conforme à la norme applied to this product.
NMB-003 du Canada.
For use with Listed Information
For more information
Japan Technology Equipment (I.T.E.).
Visit www.vertiv.com for more
information about your Avocent® External power supply (optional
Universal Management Gateway and sold separately): For safe use
appliance and UMIQ or UMIQ-E when using the optional external
modules. Korea power supply, only use the
UMIQ-PS power supply provided
USA by Vertiv. Please contact a Vertiv
WARNING: Changes or sales representative or authorized
modifications to this unit not distributor for details.
expressly approved by the party
European Union
responsible for compliance could
WARNING: This is a class A
void the user’s authority to operate
product. In a domestic environment
the equipment.
this product may cause radio
NOTE: This equipment has been interference in which case the user
tested and found to comply with may be required to take adequate
the limits for a Class A digital measures.
device, pursuant to Part 15 of the
FCC Rules. These limits are
designed to provide reasonable
protection against harmful
interference when the equipment
is operated in a commercial
environment. This equipment
generates, uses and can radiate
radio frequency energy and, if not
installed and used in accordance

PATENT
KCC-REM-AVO-CMN1002
AVOCENT CORP
https://www.vertiv.com/patents
RIP/CMN:1002

To contact Vertiv Technical Support: visit Vertiv.com


© 2019 Vertiv Group Corp. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp. All other names and logos referred to
are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv
Group Corp. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to
change without notice.

2 590-1533-501F