Rated Power
Capacity 60kVA / 54kW
(Apparent/Active)
Voltage/frequency
208Y/120V three-phase, 50/60Hz auto-sensing
nominal
Voltage/frequency
121–253VAC* (L-L), 40–70Hz
range
Efficiency
Certified 94.1% online mode, or 98% ECO mode
(Maximum%)
Enclosure Capacity Holds up to 3 UPS modules. Does not hold battery modules
Operating
0–40°C (32–104°F)**
Temperature
Whats in the box User manual, RS-232 cable, ramp for unloading UPS enclosure
The M90L-60 60kVA Parallel Online UPS can be a vital when following energy saving frameworks. The
ENERGY STAR certification ensures your equipment uses less energy and leaves a smaller carbon
footprint. The M90L-60 provides best-in-class high efficiency, lowest energy consumption and heat
output.
Benefits of the M90L-60 UPS include:
SCALABLE: When power and runtime requirements change M90L modular design makes it easy to add
modules and increase capacity
HIGHEST AVAILABILITY: The UPS system can be configured with redundant power and battery modules
making for a highly reliable UPS platform.
REDUCE ENERGY COST: Best in-class energy efficiency provides lowest energy consumption and heat
output
DUAL or SINGLE UTILITY INPUT: Provides maximum installation flexibility
MAINTENANCE BYPASS: Manually transfer critical loads from UPS power to utility power, enabling M90L-60
maintenance with no disruption to connected loads
LARGE LCD DISPLAY 5.7” LCD display provides graphic display including UPS status and warnings
MOUNTING: Standard Floor Mount Brackets included. Seismic Hold Down Anchorage available
EXTENDED BATTERY BACKUP: External battery cabinets available for extended battery runtimes
SERVICE & SUPPORT: Options to extend to 3-year factory warranty, Start Up and On-site warranties also
available.
To ensure 7/24 up time the double conversion UPS topology utilizes a static “bypass switch” within its
circuity design. If the M90L-60 54kw parallel online ups
detects a system failure, audible alarms will sound as the bypass switch is engages. This routes power
around the failed UPS and ensures critical load power to target equipment. This very important feature
allows for 100% up time for critical equipment during repair.
In the event of total power failure, the UPS will power off the rectifier when the loss of power is detected.
The UPS’ internal backup batteries will continue to supply DC power to the inverter. There is no transfer time
as the transition to battery power is instantaneous. This feature provides true uninterruptible power to
mission critical equipment.