F01S200 cabinet

The F01S200 cabinet can be configured with the MA5616 or MA5608T service device to provide the
POTS, VDSL2, and PON services.
Easy Installation
The F01S200 cabinet can be installed on a wall, against a pole, on a concrete pedestal, or on an elevated
platform
F01S200 cabinet installation modes figure

High Security
1-Prominent performance in electromagnetic compatibility (EMC) and anti-attack
2-Superior water and dust resistance, meeting requirements of the IP55 protection rating
2-Providing the HW-2802A door lock (on the left door), HW-2802B door lock (on the right door), and
an interface for an external lock, offering better protection for devices inside the cabinet.
3-Excellent performance in anti-theft by fastening bolts at the bottom inside the cabinet
Convenient Maintenance
1-Components inside the equipment compartment of the F01S200 cabinet are frontserviceable.
2-The built-in main distribution frame (MDF) in the cable distribution compartment of the F01S200
cabinet supports wire seating from the front side. The built-in optical distribution frame (ODF) supports
pre-deployment of device-side optical ports and fibers, user-side external optical cable splicing, and
device-side and user-side (internal and external) fiber patching.
3-The AC maintenance socket inside the F01S200 cabinet supplies power to an external maintenance
terminal
Prominent Monitoring
The F01S200 cabinet uses internal service devices and sensors to monitor the cabinet environment,
battery, surge protection module, and door status in real time and remotely report nalarms.
Integrated Structure Design
1-The F01S200 cabinet is integrated with service, power supply, monitoring, temperature control, and
cable distribution units. This design minimizes the installation costs and space. The F01S200 cabinet
can be installed quickly onsite to satisfy the demand for quick deployment.
2-The sealing design protects the F01S200 cabinet from dust, moisture, and rain, and ensures reliable
running of devices in harsh environments.
3-The battery power backup or remote power supply ensures the normal running of the F01S200
cabinets used in areas with unstable mains supply.
4-The F01S200 cabinet supports both MDF and ODF.Therefore, the F01S200 cabinet can
accommodate the MA5616 to provide copper line/copper-fiber/optical fiber access.
Appearance and Structure
Structure of the F01S200 cabinet configured with one DC-powered MA5616 (configured with

1
ETP4830 power system) Figure

Door Lock
The F01S100 cabinet uses the HW-2802 door lock.
Power Supply System
The power supply unit inside the F01S200 cabinet consists of the AC power distribution unit (PDU),
DC PDU, terminal block, battery (optional), and battery heater (optional)
General Power Distribution (When an ETP4830 Power System Is Used)
The AC power cable is led into the cabinet from the bottom of the battery compartment, and then
connected to the mains AC circuit breaker in the AC PDU of the equipment compartment. The AC
PDU divides the power supply into 2 channels:
1-One channel is fed to the battery heater (optional).
2-The other channel, after being converted to –48 V DC power supply by the ETP4830 power system,
is fed to the DC PDU. Then the DC PDU supplies power to the service units and enhanced heat
dissipation module (optional). In addition, the DC PDU provides 1 output for the battery to implement
battery management.
The general power distribution of the F01S200 cabinet.Figure

2
ETP4830 Power System
An AC-powered cabinet uses the ETP4830 power system to convert the AC power to the DC power for
power distribution. The small and modular ETP4830 power system supports easy installation and
maintenance, effective LCD interface management, and excellent security specifications design. The
power system supports a maximum of 30 A output current.
ETP4830 power system Figure

AH Battery
The 24 AH battery is the valve regulated lead-acid battery whose power can be restored through
charging after the battery is discharged. It can be used as the backup power supply of the device
Appearance of the 24 AH battery Figure

Specifications of the 24 AH battery Table

38 AH Battery
The 38 AH battery is the valve regulated lead-acid battery whose power can be restored through
charging after the battery is discharged. It can be used as the backup power supply of the device.
Appearance of the 38 AH battery Figure

3
Specifications of the 38 AH battery Table

NOTE
The battery charging status can be float charging or equalized charging, as described in the following:
-Equalized charging: It is a method that fully charges the discharged battery quickly by constant voltage
And limited current.The voltage is usually set high. This method balances the capacity among batteries
In a battery group
-Float charging: It is a charging method that preserves full charge for the battery by constant voltage.
The voltage is usually set low
Battery Heater
Two battery heaters must be configured when the F01S100 cabinet is used in the area where the
ambient temperature is below 0°C.
AC PDU
The F01S200 cabinet is configured with a built-in AC power distribution unit (PDU). The PDU draws
in power from the AC mains supply, and implements AC power distribution and power supply
protection.The AC PDU consists of a surge protector and circuit breaker

Surge Protector
The surge protector provides over-voltage protection against lightning for the 220 V single-phase power
systems. It protects the power system and powered devices against the surge voltage caused by
lightning strikes
Technical parameters of the surge protector Table

Circuit Breaker
The circuit breaker controls the external AC input
DC PDU
The DC PDU leads in the –48 V DC inputs from the ETP4830 power system and provides four DC
outputs, each output controlled by a separate switch.

4
Working principle of the DC PDU Figure

Output Terminal
Mapping between the circuit breakers of the output channels and the loads.Table

Maintenance Socket
The maintenance socket is used to supply power to the external device during field maintenancee.
Maintenance sockets include the European standard socket and the universal socket. You can select one
type based on your requirements

Specifications of the maintenance socket Table

Temperature Control Principle


The F01S200 cabinet provides a built-in temperature control unit for heat dissipation and heating. The
temperature control unit controls the temperature inside the cabinet within a proper range and ensures
that the service unit inside the cabinet functions properly.

5
Heat Dissipation
The F01S200 cabinet uses a wall-mounted heat exchanger, meeting the requirement for heat dissipation
at varied ambient temperatures (not higher than 40°C). To enhance heat dissipation, the F01S200
cabinet can also use an enhanced heat dissipation module, meeting the requirement for heat dissipation
at ambient temperatures higher than 40°C.Cool air enters the F01S200 cabinet through the bottom of
the cabinet, and hot air exits through the top of the cabinet, as shown in Figure
Heat dissipation principle of the F01S200 cabinet (configured with ETP4830 power system) Figure

Temperature Control Unit


The temperature control unit inside the F01S200 cabinet consists of enhanced heat dissipation module
and a heating module.
Enhanced Heat Dissipation Module
The enhanced heat dissipation module is an optional configuration. It is located at the top of the
Cabinet and addresses the heat dissipation requirements in environments with ambient temperatures
higher than 40°C. The enhanced heat dissipation module includes two 92 mm outdoor water-proof
cabinet fans and a fan monitoring board. The fan monitoring board automatically adjusts the fan speed
by monitoring the ambient temperature through its temperature sensor, implementing heat dissipation
for the cabinet.

6
Appearance of the enhanced heat dissipation module Figure

Appearance of the 92 mm cabinet fan Figure

Specifications of the 92 mm cabinet fan Table

Heater
A heater is not a mandatory component. It is installed in the battery compartment. The heater, with the
battery heater as the main component, provides heat for batteries. If the environmental temperature is
lower than -15ºC, the heater must be configured.

Technical specifications of the battery heater Table

7
Monitoring Principle
When the F01S200 cabinet is configured with service units, various sensors collect information and
report the information to the control board of the device. In this way, the F01S200 cabinet monitors the
environment, power units, and other main components inside the cabinet.
Monitoring principle of the F01S200 cabinet Figure

MA5616 Self-Monitoring Solution in the F01S200 Cabinet

.
The MA5616 uses the ETP4830 power system + VESC monitoring solution in F01S200 cabinet.
the SMU01B monitoring module monitors power status in real time and reports alarms to the control
board. The H831VESC monitoring module monitors in real time the environment parameter values
reported by the sensor connected to the monitoring port on the device and reports alarms to the control

8
Sensor
The built-in sensors of the F01S200 cabinet monitor various environment parameters of the cabinet.
Specifically, the temperature controller monitors the temperature inside the cabinet, the door status
sensor monitors the door status of the cabinet, and the battery temperature sensor monitors the battery
temperature.
Temperature Controller Relay
The temperature relay monitors the temperature in the cabinet in real time, and reports an alarm when
the temperature exceeds the threshold.When the temperature reaches the range of 67°C to 73°C, the
temperature controller is disconnected and generates an alarm. When the temperature decreases to the
range of 57°C to 67°C, the temperature controller is connected and cancels the alarm.
Appearance of the temperature controller Figure

Technical parameters of the temperature controller Table

Door Status Sensor

Battery Temperature Sensor (NTC Type)

9
Cable Distribution Unit
The F01S200 cabinet provides a built-in main distribution frame (MDF) and a built-in optical
distribution frame (ODF) for service access and service upstream transmission. When the F01S200
cabinet is configured with the MA5608T service device, it can provide PON service access. When the
F01S200 cabinet is configured with the MA5616 service device, it can provide VDSL2 and POTS
service access.
MDF
The 16-pair exchange side terminal blocks are installed to be connected with the internal cables of the
MDF and the jumper cables. The exchange side terminal blocks are also used for tests and open circuits.
The 10-pair cable side terminal blocks are installed to be connected with the external cables of the MDF
and the jumper cables. The protective unit (optional) installed in the cable side terminal block provides
the overvoltage protection and generates alarms.
Cable Distribution Device

ODF
The 6-core installation rack of the adapter and the 12-core fiber splice tray are used for optical upstream
connection.
The main functions of ODF are as follows:
1-Fixing and protecting optical fibers
2-Protecting the cores of the optical fibers with jacket peeled.
3-Splicing optical fibers
4-Distributing optical fibers
5-Routing optical fibers
6-Storing optical fibers
Appearance of the ODF in the F01S100 cabinet Figure

10
Service configuration
F01S200 Cabinet Configured with an MA5616
The layout of the F01S200 cabinet configured with an MA5616. Figure

Configuration Users/Ports
MA5616 192 VDSL2
128 (POTS + VDSL2/ADSL2+)
256 ADSL2+