TECHNICAL STATEMENT

In addition to the Technical Product Data Sheet and the Safety Data Sheet the following additional test data
are listed for the product:

HEMPADUR PRIMER 153000

Please note that the measurements given below have been obtained under very controlled laboratory
conditions. On-site measurements may give different results depending on circumstances.

ADHESION/COHESION: (ISO 4624/ASTM D 4541, PAT - Hydraulic adhesion tester):


Pull Off Value: 16 MPa (160 kgf/cm2 )

ADHESION: (ISO 2409/ASTM D 3359, Cross-cut adhesion):


Excellent adhesion: Adhesion rating 0 according to ISO 2409 and
5B according to ASTM D 3359 for the system:
1 X 40 µm DFT HEMPADUR PRIMER 15300 +
1 X 80 µm DFT HEMPATEX HI-BUILD 46410
Overcoating interval: 6 hours/20°C.

IMPACT RESISTANCE: (ISO 6272/ASTM D 2794):


No visible cracks at a frontal impact of 60 inch.lbs on 1.5 mm
panel. (Coating system: 1 X 40 µm DFT HEMPADUR PRIMER 15300
+1 X 80 µm DFT HEMPATEX HI-BUILD 46370)

RESISTANCE TO AGEING: Coating system:


40 µm DFT HEMPADUR PRIMER 15300 +
80 µm DFT HEMPATEX HI-BUILD 46370
(ISO 11997-2/ASTM D 5894, Cyclic QUV/Salt spray. Modified):
Perfect adhesion, no blistering or red rust formation and 0 mm rust
creep from the scribe after 8 cycles/1340 hours.

Coating system:
1 x 75 µm HEMPADUR PRIMER 15300 +
1 X 125 µm HEMPADUR HI-BUILD 45200:
(ISO 7253/ASTM B 117, Salt Spray):
No blistering or red rust formation, excellent adhesion and 1 - 2 mm
under cutting from scribe after 1000 hours exposure.