You are on page 1of 3

1 2 3 4 5 6 7 8

FOR CONTINUATION REFER SHEET: 11 OF 18

A A

egl22
EGL:55.697
egl27 egl26 E:302797.381
egl30 egl29 egl25
egl28 EGL:56.248 EGL:57.952
EGL:54.102 EGL:56.910 EGL:57.283 egl24 N:2740582.122
EGL:57.543 E:302533.022 E:302584.699
E:302365.898 E:302430.319 E:302482.071 E:302636.811 EGL:56.247 egl23
N:2740327.516 N:2740380.279
B N:2740146.292 N:2740218.055 N:2740273.997 N:2740432.000 E:302689.982 EGL:57.243 B
N:2740483.152 E:302744.758
N:2740534.321

C PROPOSED MV CABLE JOINT-08 C


1 M LOOP FOR STRAIGHT JOINT
.285
.912 E=302330 E=302545.153
E=302263 4.720
5.208 N=274010 N=2740339.672
N=274002

R CONTINU FO
42+000 42+100

ATION RE
D 41+900 42+200 D
42+300
41+800
42+400
41+700

FER SHEET
: 13 OF 18
CULVERT - CU-DMB-008
CH: 41+865
US IL: 53.948
DS IL: 53.837
E PIPE CULVERT(1 x 1000mmØ) E
PLAN AND PROFILE REFER TO DRAWING
NO. C0304-DMB-EUT-DG-39035

F F

LEGEND: LAYOUT REFERENCE DRAWING : E0001-S02-EGE-DG-3005B-AB KEY PLAN DUBAI PREPARED PROJECT
ETIHAD RAIL STAGE 2 & 3 PROJECT DRAWING TITLE
Rev. Date CO Revision Description Drwn Vrfr Appr Atzr
BTME LINESIDE PROPOSED MV CABLE ROUTING LAYOUT
MV RING SLD REFERENCE DRAWING : E0001-S02-ERZ-DG-30036-00 B E0001 - PACKAGE 2S
KP

DM DATE 09-DEC-2021 SHELTER DMB 05 TO SHELTER DMB 06


Z

H PR. 3Cx150sq.mm XLPE AL. 11kV U.G CABLE LINESIDE ACCESS ROAD AA 12-DEC-2021 -- ISSUED FOR APPROVAL (VER 00.00) HE MI DT AA
VERIFIED
Design & Build Contract
PR. REINFORCED ROAD CROSSING DUCT RIGHT OF WAY ABU DHABI
(Railway Integration and Systems) PROPOSED LAYOUT
A. ELGOHARI
PROPOSED UTILITY PROTECTION EXISTING FENCE DATE 09-DEC-2021
CLIENT PMC SHEET No SCALE ORIGINAL SIZE

ABBREVIATIONS: NOTE: 12 of 18 1:1000 A1


DMA

PROPOSED DUCT (BY DMD CONTRACTOR) DITCH / DRAIN QUALITY PROCESS APPROVAL
ICA CONTRACTOR PROJECT STAGE DOCUMENT STATUS
PROPOSED DUCT (BY OTHERS) EGL: EXISITNG GROUND LEVEL 1. ALL DIMENSIONS ARE IN METERS UNLESS OTHERWISE NOTED. D C.ORTIZ
DATE 09-DEC-2021 DCP3 Issued for Acceptance
PROPOSED MV CABLE JOINT BOC: BOTTOM OF CABLE 2.COORDINATE REFERENCE SYSTEM WG84 UTM39N. C
GM APPROVED
ELECTRICAL SUB CONTRACTOR DRAWING No REVISION
ROUTE MARKER TOC: TOP OF CONCRETE AL AIN ENGINEER
M. ESPOSITO
JUPITER EMC LLC.
ELECTRO MECHANICAL CONTRACTING
E0001-FJP-GCX-DS-90026 AA
FGL: FINISH GRADE LEVEL DATE 09-DEC-2021
P.O.Box : 128150
Abu Dhabi
Tel. : 02-6419541
Fax. : 02-6419542
FILE NAME: E
0001F
-JPG
-CXD
-S9-0026A
-A
d.wg
1 2 3 4 5 6 7
1 2 3 4 5 6 7 8

A A

egl9
EGL:55.638
egl19 egl17 egl12 egl11 egl10 E:303412.244
egl16 egl15 egl14 egl13
EGL:55.547 egl18 EGL:53.427 EGL:54.274 EGL:54.287 EGL:54.170 N:2741055.531
EGL:55.041 EGL:55.661 EGL:55.782 EGL:54.983
egl20 E:302939.964 EGL:54.652 E:303048.198 E:303258.216 E:303314.661 E:303364.878
egl21 E:303083.834 E:303119.403 E:303168.974 E:303217.882
EGL:55.023 N:2740705.190 E:302995.372 N:2740792.718 N:2740949.297 N:2740988.618 N:2741023.062
EGL:56.144 N:2740820.463 N:2740847.756 N:2740884.819 N:2740920.545
E:302894.932 N:2740750.606
B
E:302851.196 B
N:2740629.663 N:2740667.311

P O S ED M V C ABLE JOINT-07
PRO IGHT JOINT
P F OR S T R A
1 M LOO
E=302884.715 E=303144.644
C C
N=2740658.600 N=2740866.490
FOR CONTINUATI

D D
42+600 42+700 42+800 42+900 43+000
ON

42+500 43+100 43+200


REFER SHEET: 12
OF 18

E E

F F

FOR CONTINUATION REFER SHEET: 14 OF 18


G

LEGEND: LAYOUT REFERENCE DRAWING : E0001-S02-EGE-DG-3005B-AB KEY PLAN DUBAI PREPARED PROJECT
ETIHAD RAIL STAGE 2 & 3 PROJECT DRAWING TITLE
Rev. Date CO Revision Description Drwn Vrfr Appr Atzr
BTME LINESIDE PROPOSED MV CABLE ROUTING LAYOUT
MV RING SLD REFERENCE DRAWING : E0001-S02-ERZ-DG-30036-00 B E0001 - PACKAGE 2S
KP

DM DATE 09-DEC-2021 SHELTER DMB 05 TO SHELTER DMB 06


Z

H PR. 3Cx150sq.mm XLPE AL. 11kV U.G CABLE LINESIDE ACCESS ROAD AA 12-DEC-2021 -- ISSUED FOR APPROVAL (VER 00.00) HE MI DT AA
VERIFIED
Design & Build Contract
PR. REINFORCED ROAD CROSSING DUCT RIGHT OF WAY ABU DHABI
(Railway Integration and Systems) PROPOSED LAYOUT
A. ELGOHARI
PROPOSED UTILITY PROTECTION EXISTING FENCE DATE 09-DEC-2021
CLIENT PMC SHEET No SCALE ORIGINAL SIZE

ABBREVIATIONS: NOTE: 13 of 18 1:1000 A1


DMA

PROPOSED DUCT (BY DMD CONTRACTOR) DITCH / DRAIN QUALITY PROCESS APPROVAL
ICA CONTRACTOR PROJECT STAGE DOCUMENT STATUS
PROPOSED DUCT (BY OTHERS) EGL: EXISITNG GROUND LEVEL 1. ALL DIMENSIONS ARE IN METERS UNLESS OTHERWISE NOTED. D C.ORTIZ
DATE 09-DEC-2021 DCP3 Issued for Acceptance
PROPOSED MV CABLE JOINT BOC: BOTTOM OF CABLE 2.COORDINATE REFERENCE SYSTEM WG84 UTM39N. C
GM APPROVED
ELECTRICAL SUB CONTRACTOR DRAWING No REVISION
ROUTE MARKER TOC: TOP OF CONCRETE AL AIN ENGINEER
M. ESPOSITO
JUPITER EMC LLC.
ELECTRO MECHANICAL CONTRACTING
E0001-FJP-GCX-DS-90026 AA
FGL: FINISH GRADE LEVEL DATE 09-DEC-2021
P.O.Box : 128150
Abu Dhabi
Tel. : 02-6419541
Fax. : 02-6419542
FILE NAME: E
0001F
-JPG
-CXD
-S9-0026A
-A
d.wg
1 2 3 4 5 6 7
1 2 3 4 5 6 7 8

FOR CONTINUATION REFER SHEET: 13 OF 18

A A
- The copying, reproduction and use of this work in any form whatsoever
is forbidden without the written authorization of Hitachi Rail STS S.p.A.
© Property of Hitachi Rail STS S.p.A, 2020, all rights reserved.

egl8 egl7
EGL:55.904 egl6 egl5
EGL:53.518 EGL:55.254
E:303461.519 E:303504.018 EGL:55.694
N:2741089.275 E:303565.671 E:303621.204 egl4
N:2741118.440 N:2741198.767 EGL:54.884
N:2741160.701
E:303689.476
B N:2741245.566 B

1
E=303951.77
PROPOSED MV CABLE JOINT-06 59
N=2741425.3
1 M LOOP FOR STRAIGHT JOINT
E=303781.598
egl3 N=2741197.022
EGL:55.788 egl2
E:303741.423 EGL:53.191 egl1
C N:2741169.563 E:303804.514 EGL:52.851 C
N:2741212.685 E:303864.341 8
N:2741253.577 E=304003.95
05
N=2741349.0

D D
43+300 43+400 43+500 43+600 43+700 43+800 43+900 44+000

E CULVERT - CU-DMB-0010 E
CH: 43+680
US IL: 53.500
DS IL: 53.300
PIPE CULVERT(1 x 1000mmØ)
PLAN AND PROFILE REFER TO DRAWING
NO. C0304-DMB-EUT-DG-39036

F F

FOR CONTINUATION REFER SHEET: 15 OF 18


G

LEGEND: LAYOUT REFERENCE DRAWING : E0001-S02-EGE-DG-3005B-AB KEY PLAN DUBAI PREPARED PROJECT
ETIHAD RAIL STAGE 2 & 3 PROJECT DRAWING TITLE
Rev. Date CO Revision Description Drwn Vrfr Appr Atzr
BTME LINESIDE PROPOSED MV CABLE ROUTING LAYOUT
MV RING SLD REFERENCE DRAWING : E0001-S02-ERZ-DG-30036-00 B E0001 - PACKAGE 2S
KP

DM DATE 09-DEC-2021 SHELTER DMB 05 TO SHELTER DMB 06


Z

H PR. 3Cx150sq.mm XLPE AL. 11kV U.G CABLE LINESIDE ACCESS ROAD AA 12-DEC-2021 -- ISSUED FOR APPROVAL (VER 00.00) HE MI DT AA
VERIFIED
Design & Build Contract
PR. REINFORCED ROAD CROSSING DUCT RIGHT OF WAY ABU DHABI
(Railway Integration and Systems) PROPOSED LAYOUT
A. ELGOHARI
PROPOSED UTILITY PROTECTION EXISTING FENCE DATE 09-DEC-2021
CLIENT PMC SHEET No SCALE ORIGINAL SIZE

ABBREVIATIONS: NOTE: 14 of 18 1:1000 A1


DMA

PROPOSED DUCT (BY DMD CONTRACTOR) DITCH / DRAIN QUALITY PROCESS APPROVAL
ICA CONTRACTOR PROJECT STAGE DOCUMENT STATUS
PROPOSED DUCT (BY OTHERS) EGL: EXISITNG GROUND LEVEL 1. ALL DIMENSIONS ARE IN METERS UNLESS OTHERWISE NOTED. D C.ORTIZ
DATE 09-DEC-2021
DCP3 Issued for Acceptance
PROPOSED MV CABLE JOINT BOC: BOTTOM OF CABLE 2.COORDINATE REFERENCE SYSTEM WG84 UTM39N. C
GM APPROVED
ELECTRICAL SUB CONTRACTOR DRAWING No REVISION
ROUTE MARKER TOC: TOP OF CONCRETE AL AIN ENGINEER
M. ESPOSITO
JUPITER EMC LLC.
ELECTRO MECHANICAL CONTRACTING
E0001-FJP-GCX-DS-90026 AA
FGL: FINISH GRADE LEVEL DATE 09-DEC-2021
P.O.Box : 128150
Abu Dhabi
Tel. : 02-6419541
Fax. : 02-6419542
FILE NAME: E
0001F
-JPG
-CXD
-S9-0026A
-A
d.wg
1 2 3 4 5 6 7