You are on page 1of 210

R8 D

U 1 DISPLACEMENT

T
Y H E AV Y

I T A LY

HEAVY DUTY SINGLE DISPLACEMENT HYDRAULIC MOTOR


R8D SERIES
T E C H N I C A L C ATA LO G U E

The data specified into the catalogue are for product description purpose only
and must not be interpreted as warranted characteristics in legal sense.
Italgroup S.r.l. reserves the right to implement modifications without notice.

All partial or total reproduction and copy without written authorization of Ital-
group S.r.l. is strictly forbidden.

©2018 ITALGROUP S.R.L. - ALL RIGHTS RESERVED -

R8D rev.00 - Oct. 2018


GENERAL INDEX
FORMULAS Pag. 3

INTRODUCTION - GENERAL INFORMATION Pag. 4 - 5

MOTOR TECHNICAL DATA Pag. 6 - 7

INTERCHANGEABILITY CHART Pag. 8

R8D ORDERING CODE Pag. 9

HYDRAULIC FLUID RECOMMENDATIONS Pag. 10 - 11

DRAIN RECOMMENDATIONS - FLUSHING Pag. 12 - 13

STANDARD SHAFT SEAL FEATURES Pag. 14 - 15

MOTOR INSTALLATION AND STARTUP Pag. 16 - 18

MOTOR HANDLING AND STORAGE Pag. 19 - 20

MAINTENANCE OPERATION Pag. 21

INSTRUCTION AND ADVICES Pag. 22

SPECIAL FEATURES Pag. 23

TROUBLESHOOTING Pag. 24 - 25

UNIT CONVERSIONS Pag. 26

R8D H2 Pag. 27 - 36

R8D H3 Pag. 37 - 50

R8D H4 Pag. 51 - 69

R8D H45 Pag. 71 - 79

R8D H5 Pag. 79 - 99

R8D H55 Pag. 101 - 113

R8D H6 Pag. 115 - 133

R8D H7 Pag. 135 - 149

R8D H8 Pag. 151 - 162

R8D H9 Pag. 163 - 173

MOTOR DISTRIBUTORS Pag. 174 - 175

TACHOMETERS Pag. 177 - 180

SPLINED BILLETS - SPLINED BARS Pag. 181 - 185

ADAPTOR FLANGES Pag. 186 - 187

VALVES Pag. 189 - 206

CONTACT US - REACH US Pag. 207

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
I TALGR OUP M OTORS R8D SE RIE S T E CH N ICAL CATALOGU E

R8D rev.00 - Oct. 2018


FORMULAS
Torque [Nm] = Specific torque [Nm/bar] * Pressure [bar]

Displacement [cc/Rev] * Pressure [bar]


Torque [Nm] =
62.8

Torque [Nm] * Speed [rpm]


Power [kW] =
9549

Torque [Nm] * Speed [rpm]


Power [CV] =
7023

Flow [l/min] * 1000


Speed [rpm] =
Displacement [cc/Rev]

Torque [Nm] * 62,8


Displacement [cc/Rev] =
Pressure [bar]

Displacement [cc/Rev] * Speed [rpm]


Flow [l/min] =
1000

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 3
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

INTRODUCTION
GENERAL INFORMATION
Carefully read the use and maintenance manual before start-up the motor. The
use and maintenance manual must be placed near to motor installation location
in order to guarantee operators easy access to the instruction manual. For further
information please contact Italgroup.

MOTOR DESC RI P T ION

R8D series motors are radial piston hydraulic motors (generally indicated as LSHT motors,
low speed high torque motors) with a rotating shaft (1) and a stationary housing (2). The pi-
stons (4) are located radially and the working fluid provide the mechanical force that push
the pistons against the eccentric shaft, providing the shaft ouput torque. The inlet and outlet
flow to and from the pistons is regulated by a distributor (5), that provides the oil distribution
correct timing. The pistons transfer the forces to the eccentric shaft through a connecting rod
(3). Acting in the adequate way (increasing or reducing the oil flow coming from the pump)
the motor rotational speed can be increased or reduced. The motor design guarantee extre-
mely high starting torque and high mechanical working efficiency. Respecting the limitation
of working parameters (indicated into the technical datasheets) and all recommendations (in-
cluding fluid recommendations), high motor lifetimes are obtained and very low maintenance
requirements are needed.

4
2
3

4 R8D rev.00 - Oct. 2018


R8D SERIES
Hydraulic motors of the R8D series are single displacement crankshaft radial piston motors. Thanks to great
variety of accessories R8D series can be used in a wide range of applications such as:

• marine equipments
• winches
• offshore equipments
• conveyors
• injection moulding machines
• steel bending machines
• fork lifts trucks
• skid steer loaders
• dumpers
• agricultural and forestry machines
• municipal vehicles
• airport machinery

P R ODUCT FEAT UR ES:

High volumetric and mechanical efficiencies


Very smooth running at low speeds
High starting torque / constant torque
Wide speed range
Compact Design
Low maintenance and high reliability
Bi-directional
High radial and axial force allowed
Speed sensor available
Built-in valves available

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 5
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

MOTOR TECHNICAL DATA


Motor Size Displacement Theoretical Max cont. Max cont. Peak speed Max cont. Max Dry
torque pressure speed (**) power (*) power weight
[cc] [Nm/bar] [bar] [rpm] [rpm] [kW] [kW] [kg]
R8D 300 H2 314 5 270 900 1100 45 66 42
R8D 350 H3 342 5.4 270 850 950 85 130 68
R8D 400 H3 398 6.3 270 750 860 85 130 68
R8D 450 H3 452 7.2 270 650 760 85 130 68
R8D 500 H3 492 7.8 270 600 690 85 130 68
R8D 600 H3 594 9.5 270 500 570 85 130 68
R8D 700 H3 707 11.2 170 440 500 78 118 68
R8D 500 H4 493 7.8 270 700 800 130 160 92
R8D 600 H4 584 9.3 270 700 800 130 160 92
R8D 700 H4 714 11.4 270 500 580 130 160 92
R8D 800 H4 792 12.6 270 450 530 130 160 92
R8D 850 H4 847 13.5 270 420 490 130 160 92
R8D 900 H4 904 14.4 270 400 460 130 160 92
R8D 1000 H4 992 15.8 270 355 405 130 160 92
R8D 1250 H4 1247 19.8 200 280 320 102 130 92
R8D 1100 H45 1182 18.8 250 400 450 158 190 120
R8D 1400 H45 1376 21.9 250 350 400 158 190 120
R8D 900 H5 941 15 270 550 600 178 210 173
R8D 1000 H5 1094 17.4 270 500 550 178 210 173
R8D 1200 H5 1231 19.6 270 450 510 178 210 173
R8D 1400 H5 1376 21.9 270 410 470 178 210 173
R8D 1500 H5 1528 24.3 270 390 450 178 210 173
R8D 1600 H5 1648 26.2 270 370 425 178 210 173
R8D 1800 H5 1815 28.9 250 340 390 178 210 173
R8D 2000 H5 2034 32.4 190 280 310 140 160 173
R8D 1800 H55 1800 28.7 270 265 290 190 220 203
R8D 2000 H55 1962 31.2 270 245 270 190 220 203
R8D 2100 H55 2035 32.4 270 235 260 190 220 203
R8D 2150 H55 2126 33,8 270 235 260 190 220 203
R8D 2200 H55 2193 34,9 270 220 240 190 220 203
R8D 2300 H55 2293 36.5 250 210 235 180 210 203
R8D 2400 H55 2393 38.1 250 190 220 170 210 203
R8D 1800 H6 1866 29.7 270 350 400 220 245 308
R8D 2000 H6 1993 31.7 270 350 400 220 245 308
R8D 2200 H6 2206 35.1 270 325 375 220 245 308
R8D 2500 H6 2525 40.2 270 285 325 220 245 308
R8D 2800 H6 2807 44.7 270 250 290 220 245 308
R8D 3000 H6 2983 47.5 270 235 270 220 245 308
R8D 3200 H6 3289 52.4 270 210 240 220 245 308
R8D 3500 H6 3479 55.4 270 200 230 210 235 308

6 R8D rev.00 - Oct. 2018


Motor Size Displacement Theoretical Max cont. Max cont. Peak Max cont. Max Dry
torque pressure speed speed (**) power (*) power weight
[cc] [Nm/bar] [bar] [rpm] [rpm] [kW] [kW] [kg]
R8D 3400 H7 3413 54.3 270 200 220 238 265 405
R8D 3600 H7 3650 58.1 270 185 210 238 265 405
R8D 3900 H7 3907 62.2 270 175 200 238 265 405
R8D 4300 H7 4343 69.1 270 160 190 238 265 405
R8D 4600 H7 4616 73.5 270 150 190 238 265 405
R8D 5000 H7 5088 81.0 270 140 180 238 265 405
R8D 5400 H7 5384 85.7 270 130 170 230 258 405
R8D 3000 H8 3020 48.1 270 240 300 215 236 590
R8D 6000 H8 5966 95 250 120 140 215 236 590
R8D 6500 H8 6581 104.7 250 120 140 215 236 590
R8D 6800 H8 6962 110.8 250 120 140 215 236 590
R8D 7600 H8 7620 121.3 250 90 100 215 236 590
R8D 8000 H8 8062 128.3 240 80 90 215 236 590
R8D 7000 H9 7050 112 270 160 190 330 370 750
R8D 8000 H9 8332 132.6 270 135 160 330 370 750
R8D 9000 H9 8757 139.4 260 130 155 330 370 750
R8D 10000 H9 10214 162.6 250 110 135 330 370 750
R8D 11000 H9 11016 175.3 250 105 120 330 370 750
R8D 12000 H9 12073 192,2 250 95 110 330 370 750
R8D 13000 H9 13020 207.3 250 90 105 330 370 750

For all motors:


- Hydrostatic test pressure: 420 bar
- Refer to motor performance diagrams for more information
- (*) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required.
For more information please contact our technical department.
- (**) Do not exceed maximum power.
The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 7
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

INTERCHANGEABILITY CHART
Italgroup motor code Cross reference motor code

R8D 450/B30 HMB 30


R8D 800/B45 HMB 45
R8D 1000 H5 - R8D 1000/B60 H5 HMB 60
R8D 1400 H5 - R8D 1400/B80 H5 HMB 80
R8D 1600 H5 - R8D 1600/B100 H5 HMB 100
R8D 2150 H55 HMB 125
R8D 2200 H6 - R8D 2200/B125 H6 HMB 125
R8D 2500 H6 - R8D 2500/B150 H6 HMB 150
R8D 3000 H6 - R8D 3000/B200 H6 HMB 200
R8D 4600 H7 HMB 270
R8D 5400 H7 HMB 325
R8D 350-450-500/C H3 MR 350 - MR 450 - MRE 500
R8D 600-700-800/C H4 MR 600 - MR 700 - MRE 800

R8D 1100-1400/C H45 MR 1100 - MRE 1400

R8D 1000-1400-1600/C1100 H5 MR 1100 - MRE 1400 - MR 1600


R8D 1600-1800-2000/C H5 MR 1600 - MR 1800 - MRE 2100
R8D 1800-2100-2400/MR1800 H55 MR 1800 - MRE 2100 - MRA 2400
R8D 2500-2800-3000-3500/C H6 MR 2400 - MR 2800 - MRE 3100 MRA 3500
R8D 3600-4500-5400/C H7 MR 3600 - MR 4500 - MRE 5400
R8D 6500-6800-8000/C H8 MR 6500 - MR 7000 - MRE 8200
R8D 450-500/RM H3 RM 450 - RM 500
R8D 900/RM H5 RM 900
R8D 5000/RM H7 RM 5000
R8D H2/GM2 GM2
R8D H4/GM4 GM4
R8D H5/GM5 GM5
R8D H6/GM6 GM6
R8D H2/S M2
R8D H3/S M3
R8D H4/S M4

8 R8D rev.00 - Oct. 2018


R8D - ORDERING CODE

R8D -- -- -- -- -- -- -- --

DISPLACEMENT INTERCHANGEABILITY SERIE SHAFT TACHOMETER SPECIAL


FEATURES
300 /GM2 /S H2 A0 A01 TA
See pag. 27-36 MP
A1 A11 TB
SPSL
350 400 450 /C /RM H3 A12 A13 TT1
HPS
500 600 700 /H4C A2 A21 TQ1
CCW
See pag. 37-50 A22 A23 EST
See pag. 23
500 600 700 /C /B45 H4 A3 A31 EST30
A32 A33 Z--
800 850 900 /GM4 /S EST31
A34 A4 Italgroup
1000 1250 /SB506 EST32
internal code
See pag. 51-69 A5 EST33

1100 1400 /C H45 See pag. 177-180


See pag. 71-78

900 1000 1200 /C1100 /C H5


1400 1500 1600 /B60 /B80 DISTRIBUTOR SPLINED BILLET / SPLINED BAR
1800 2000 /B100 /GM5
D31B D31BJ SB2 SB3
/S /RM D36B D36BJ SB4 SB5
See pag. 79-99
D310B D310BJ SB6 SB7
1800 2000 2100 /MR1800 H55
D40 D40J SB8 SB9
2150 2200 2300
D47 D47J SB10 SB11
2400
See pag. 101-113 D416 D416J SB12 SB16
D75 D75J SB17 SB21
1800 2000 2200 /C /B125 H6
D90 D90J SB22 SB24
2500 2800 3000 /B150 /B200
D200 D200J SB27 SB30
3200 3500 /GM6 /PL
D202 D202J B8076 B8078
See pag. 115-133
See pag. 174-175 B8079
3400 3600 3900 /C /RM H7 See pag. 181-185
4300 4600 5000
5400
See pag. 135-149

3000 6000 6500 /C H8


6800 7600 8000
See pag. 151-162

7000 8000 9000 /C H9


10000 11000 12000
13000
See pag. 163-173

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 9
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

HYDRAULIC FLUID RECOMMENDATIONS


Fluid selection In general, we recommend the use of hydraulic oils with minimum viscosity
index of 95, with anti-wear additives (ISO HM and HV). Once normal working
temperature is reached, the drain oil viscosity must be at least 35-40 cSt,
preferably in the range from 40 to 60 cSt.
HE oils (ecological fluids) are allowed, but must be used with particular at-
tention, because them can influence the motor seals compatibility, and can
reduce motor performances and life. Please contact us in case of HE oils
usage.

Optimal viscosity selection Referring the first approximated selection to the room temperature, we ad-
vice the following:
Room temperature Oil
-20°C/0°C BP ENERGOL HLP – HM 22
-15°C/+5°C BP ENERGOL HLP – HM 32
-8°C/+15°C BP ENERGOL HLP – HM 46
0°C/+22°C BP ENERGOL HLP – HM 68
+8°C/+30°C BP ENERGOL HLP – HM 100
-20°C/+5°C BP BARTRAN HV 32
-15°C/+22°C BP BARTRAN HV 46
0°C/+30°C BP BARTRAN HV 68
ATF (automatic transmission fluid) oils, SAE 10-20-30 W oils, multigra-
de motor oils (SAE 15 W 40, 10 W 40), universal oils, can also be used.
Always fill the motor (please refer to the “DRAIN RECOMMENDATIONS”
section) with the selected hydraulic fluid before motor start-up. Du-
ring cold start-up avoid high-speed operation until the system reach
the working temperature, in order to provide an adequate lubrication.
Every 5-8 °C of increase respect to the optimal working tempera-
ture for the selected oil, the hydraulic fluid life decrease of about
40-50% (refer to “OXIDATION” section). Consequently, the mo-
tor lifetime will be affected by the working temperature increa-
se respect to the optimal working temperature of the selected oil.
The maximum continuous working temperature is 70 °C, the tempera-
ture must be measured from motor drain line. If the motor doesn’t have
a drain line, the temperature must be evaluated at the return line port.

Fire resistant oil limita- Max cont. Max int. Max


tions Pressure Pressure Speed
[bar] [bar] [rpm]
HFA, 5-95% oil-water 103 138 50%
HFB, 60-40% oil-water 138 172 100%
HFC, water-glycol 103 138 50%
HFD, ester phosphate 250 293 100%

10 R8D rev.00 - Oct. 2018


Filtration Hydraulic systems oil must always be filtered.
The choice of filtration grade derives from needs of service life and money
spent. In order to obtain stated service life it is important to follow our recom-
mendations concerning filtration grade.
When choosing the filter it is important to consider the amount of dirt particles
that filter can absorb and still operate satisfactorily. For that reason we recom-
mend filters showing when you need to substitute filtering cartridge.
· 25 μm filtration required in most applications
· 10 μm filtration in closed circuit applications

Oxidation Hydraulic oil oxidizes with time of use and temperature. Oxidation causes
changes in colour and smell, acidity increase or sludge formation in the tank.
Oxidation rate increases rapidly at surface temperatures above 60°C, in these
situations oil should be checked more often.
The oxidation process increases the acidity of the fluid; the acidity is stated in
terms of the “neutralization number”. Oxidation is usually slow at the begin-
ning and then it increases rapidly.
A sharp increase (by a factor of 2 to 3) in neutralization number between
inspections shows that oil has oxidized too much and should be replaced
immediately.

Water content Oil contamination by water can be detected by sampling from the bottom of
the tank. Most hydraulic oils repel the water, which then collects at the bottom
of the tank. This water must be drained off at regular intervals. Certain types
of transmission oils and engine oils emulsify the water; this can be detected
by coatings on filter cartridges or a change in the colour of the oil. In such
cases, obtain your oil supplier advice.

Degree of contamina- Heavy contamination of the oil causes wear rising in hydraulic system compo-
tion nents. Contamination causes must be immediately investigated and reme-
died.

Analysis It is recommended oil being analyzed every 6 months. The analysis should
cover viscosity, oxidation, water content, additives and contamination. Most
oil suppliers are equipped to analyze oil state and to recommend appropriate
action. Oil must be immediately replaced if the analysis shows that it is exhau-
sted.

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 11
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

DRAIN RECOMMENDATIONS
MOTOR AXIS HORIZONTAL

Leakage line Leakage line

Plug Plug
Check valve
1 bar setting
50 min

50 min

MOTOR AXIS VERTICAL, SHAFT DOWN


50 min
50 min

Leakage line
Leakage line Plug
Plug
50 min
50 min
50 min

Check valve
1 bar setting
50 min

50 min
50 min
50 min

MOTOR AXIS VERTICAL, SHAFT UP

Leakage line using


50 min
50 min
50 min

an additional drain Leakage line using


(on request) an additional drain
(on request)

Leakage line

Plug Plug Check valve Plug Check valve


Plug Plug
1 bar setting 1 bar setting

LEAKAGE LINE CONNECTION


Always fill the motor with hydraulic fluid before start-up. Arrange piping in a way that the motor cannot
drain off and cannot generates air bubbles into the motor case. Under certain conditions may be is neces-
sary to arrange a check valve in order to help avoiding the motor drain off. Always check carefully that the
leakage line pressure doesn’t overcome 10 bar pressure: therefore leakage lines must be shorter as possi-
ble and with a minimum flow resistance.

12 R8D rev.00 - Oct. 2018


FLUSHING
Motor Flushing flow [l/min]

R8D H2 5
R8D H3 8
R8D H4 10
R8D H45 - R8D H5 15
R8D H55 - R8D H6 - R8D H7 - R8D H8 - R8D H9 20

Important note: the above value are approximated. The correct way to operate is the following: the flushing flow is
adequate if during the motor operation the drain oil viscosity be at least 35-40 cSt, preferably in the range from 40 to
60 cSt.

Maximum continuous case pressure 6 bar (10 bar peak pressure). Special seals for 20-25 bar continuous case pres-
sure are available upon request (ordering code: HPS).

FLUSHING OUTLET PORT

Please note: the flushing outlet port


must always be located in the highest
possible position.

MAXIMUM CASE PRESSURE

6 bar continuous
10 bar peak
FLUS HING
For standard R8D motors INLET PORT

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 13
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

STANDARD SHAFT SEAL FEATURES


Features Type: BABSL
Form: AS DIN 3760
Material: SIMRIT® 72 NBR 902
SIMRIT® 75 FKM 595

Material SIMMERRING® radial shaft seal with rubber covered O.D., short,
flexibility suspensed, spring loaded sealing lip and additional dust
lip:
see Part B/SIMMERRING®, sections 1.1 and 2.

Application Sealing lip and O.D.:

– Acrylonitrile-butadiene rubber with 72


Shore A hardness (designation: SIMRIT® 72 NBR 902)
– Fluoro rubber with 75 Shore A hardness
(designation: SIMRIT®75 FKM 595)

Metal insert:
– Plain steel DIN 1624

Spring:
– Spring steel DIN 17223

Operating conditions See Part B/ SIMMERRING®, sections 2. 4.

Media: mineral oils, synthetic oils

Temperature:
-40°C to +100°C (SIMRIT® 72 NBR 902)
-40°C to +160°C (SIMRIT® 75 FKM 595)

Surface speed: up to 5 m/s

Working pressure: see diagram on next page, pressure is function of


surface speed (i.e. of rotating speed and shaft diameter)

14 R8D rev.00 - Oct. 2018


Housing and machining See Part B/ SIMMERRING®, sections 2.
criteria
Shaft:
Tolerance: ISO h11
Concentricity: IT 8
Roughness: Ra=0.2-0.8 μm
Rz=1-4 μm
Rmax=6 μm
Hardness: 45-60 HRc
Roughness: non oriented;
preferably by plunge grinding

Housing:
Tolerance: ISO H8
Roughness: Rmax<25 μm

Pressure diagram

Special seals for 20-25 bar continuous case pressure are available upon request (ordering code:
HPS). Refer to page 23 for more information.

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 15
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

MOTOR INSTALLATION AND STARTUP


Motor installation and The motor, after testing, it’s packed in different ways that depends by cu-
start-up stomer and/or logistic requirements. The motor must be carefully moved
from his box or pallet, with the assistance of correctly sized movimenta-
tion tools, like eyebolts (all the motors has a thread hole in the shaft end,
please refer to the R8D general catalogue, shafts section) or lifting slings.

When the motor is moved from one place to another always be very ca-
reful and act in a way that the motor is stable and under control during
movimentation (refer to handling and storage section for more details).

Before mount the motor, check carefully the absence of damage happened
for example during transportation and/or storing.

For mounting dimensions please refer to the R8D installation drawings. The
motor must be installed using the correct screws size (we recommends the
use of 10.9 and 12.9 class resistance fixing screws) and must be placed on
a structure that is capable to correctly support the motor during functioning:
for this reason the structure must not only be able to support the motor
weight but must also assure the absence of vibration during operation and
must win the reaction forces that are generated by the working torque. Re-
garding the motor fitting design, the concentricity between the centering
diameter (spigot) and shaft (both splined or parallel) must be assured with a
strict tolerance (please refer to the following general indication). If the con-
centricity between the shaft and the centering diameter and/or fixing holes
is not respected, in the worst case the motor can have an unusual failure or
can work only with low performances. Splined adaptors (splined billets) are
available upon request.

Ø0,15 A B
C

0,05
A
0,05
0,05 B
ØA H6
D

D
ØA
ØB

ØB

B 3.2

E
3.2

A
F

+1
E+1 0 0.1
+1
F+1 0

16 R8D rev.00 - Oct. 2018


Hoses and piping must be clean and free from contamination. Use proper
hoses for oil connection, both for inlet and outlet main ports, and for drain line.
Refer to hoses and fitting constructors in order to correctly size and select ho-
ses and fittings. In order to keep control on the oil compressibility keep hoses
to the minimum recommended size and select pipelines most rigid as possible.

The motor can be mounted in any position (refer also to drain recommenda-
tions section). In run-away conditions you must use counterbalance valves.
When the motor is installed vertically with shaft pointing upwards, consult our
technical department. If the motor is connected to high inertial loads, the hy-
draulic system must be designed to prevent peaks of pressure and cavitation.
Consider the use of relief valves, possibly directly mounted on motor distributor
in case the application can generates pressure peaks at the motor ports: the
relief valve should be able to discharge all the flow (or at least a good part of
it) with a limited pressure increase. Italgroup can provide differents valve types
that can be placed directly on the motor distributor (please refer to Italgroup
valves technical catalogue).

Motor case and pistons must be completely filled with oil before starting.
Do not load motor to maximum working pressure instantly. During cold start-up
avoid high-speed operation until the system reach the working temperature.
Connect the case drain directly to tank, and avoid excessive drain line pressure
losses (the case drain pressure must not exceed 10 bar continuous pressure for
R8D serie standard motors). The case drain port on the motor must be located
on the highest point of the installation to ensure that the motor will always be
full of oil. (See drain recommendations page for more details)

Maximum oil temperature must not exceed 70°C. Heath exchangers must be
used with higher temperatures. The operating fluid viscosity must always be
higher than a certain minimum value (see “fluid recommendation” section) in
order to guarantee an optimal motor internal lubrication. When the working
conditions cause the motor case overheating above a critical value, the motor
flushing is required. Flushing consists in the introduction of fresh oil (taken from
the hydraulic circuit) into the motor case. Oil must be taken from the return line
to avoid internal motor damage (the continuous motor case pressure must be
maximum 6 bar). Flushing is an important operation that can be very effective
to improve motor lifetime with heavy duty working conditions and improve the
motor mechanical efficiency.
The motor flushing, if the motor works in one direction only, can be easily
performed connecting the motor return line to the lowest motor drain port. The
highest motor drain port must be connected to the tank. For D75 and D90 flow
distributors, the side 1/4” metallic plugs can be used for flushing circuit instal-
lation: infact the plug (corresponding to the return line port) can be removed
and the connection between motor low pressure port and motor case can be
correctly realized.

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 17
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

MOTOR INSTALLATION AND STARTUP


If the motor axis is not horizontal and/or the motor works in bidirectional
operation, please contact Italgroup technical department, that can assist
you to advice how to perform the desired operation in the best way. Just
for your reference, Italgroup can provide you flushing valves in order to
perform an effective flushing circuit.

Minimum speed is very low and can reach values near to 0.5-1 rpm (depen-
ding on motor displacement). In case of low speed vibration a reasonable
back pressure can eliminate or minimize the vibration and noise level (a
general guideline value can be defined by 5-8 bar back pressure). For
more information please contact our technical department.

Back pressure limit for R8D series motors is 70-80 bar (back pressure oc-
curs for example when hydraulic motors are installed in series circuit). High
back pressure values are often responsible of motor overheating, so if drain
temperature reach values that bring the oil viscosity under the recommen-
ded limit (refer to fluid recommendations section), perform appropriate mo-
tor flushing and/or reduce the back pressure.

During start-up and in the period immediately after it, any hydraulic instal-
lation must be regurarly and carefully checked at frequent intervals. The
working pressure must be checked in order to understand that it agrees
with the design values. The drain line pressure for standard motors must
not overcome 10 bar continuous. If leakage occurs, check the reason,
correct it and carry out new measurements. Check all lines, connections,
screws, etc, and tighten if necessary. Replace contaminated fluid immedia-
tely.

The motor installation and start-up must be performed by instructed and


experienced personnel only.

Please contact us freely to obtain further information.

18 R8D rev.00 - Oct. 2018


MOTOR HANDLING AND STORAGE
Motor handling The motor must be correctly packed during transport and correctly stored into
the warehouse in order to avoid eventual damages that can make the motor
functioning not adequate.

During handling operations, make sure that the motor shaft and tachometer
shaft (if present) don’t receive any hit, in order to avoid motor damage.

During all operations of lifting and handling, never movimentate motors by


hand but use adequate tools. In order to avoid that motor can falls, creating
danger for authorized working persons in the nearings, use one of following
methods:

- use lifting slings of adequate capacity;


- use adequate eyebolt using the thread hole in the shaft end.

Refer to the following pictures.

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 19
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

MOTOR HANDLING AND STORAGE


Storage Storing must be carefully made using adequate storing tools (for example
boxes, pallets, etc...) that can guarantee that the motor is stable and cannot
move without control, in order to avoid damage problems. Make sure that
the weight of the motor doesn’t be substained by the motor shaft or by the
tachometer shaft (if present).

R8D series motors are supplied together with plastic plugs, that keep the
hydraulic oil (that was used during final test in Italgroup testing workbench)
inside the motor. A thin oil film is present on the internal motor parts, where-
as the external parts are covered with antirust oil that prevents damage from
oxidation and corrosion.

Therefore the motors can be safely stored into the customer warehouse
without performance losses for long periods (up to 4-6 months).
The storing location must has some important characteristics:
- room temperature comprised between -15°C and +55°C without fast and/or
excessives temperature excursions;
- low relative humidity;
- absence of aggressive and corrosive medias in the motor nearings.

In particular, if motor should be motionless for more than 4-6 months, it must
be protected against internal rust. Proceed as follows:
- fill the motor case with hydraulic oil. After that the motor case is full of oil,
close it with a screw plug;
- fill the motor also from inlet or outlet port. Turn the shaft by hand (the shaft
must make about one revolution) and finally close the inlet and outlet ports.

Please note that the plastic plugs are necessary not only to keep the hydrau-
lic oil inside the motor, but even to avoid that dirt and other fluids (like water
for example) can enter into the motor and create damage during storing or
during motor start-up. Therefore make sure all drain ports, supply ports and
discharge ports are closed during motor handling and storing. If plugs are
missing, use plastic plugs or adequate systems in order to guarantee that
the motor is well protected by dirt and other fluids.

20 R8D rev.00 - Oct. 2018


MAINTENANCE OPERATIONS
Maintenance operations All the assembly and maintenance works must be performed when the motor
is stopped and not connected to any power source, in order to avoid an acci-
dental start-up. In addition the pressure inside the motor must be set to zero
(the motor must be depressurized) before to perform maintenance operations.
The motor maintenance must be performed by instructed and experienced
personnel only, following carefully Italgroup advices and procedures.

R8D series motors are internally lubricated by the operating fluid, if the motors
are used according to the technical data reported into the R8D catalogue, they
need very limited maintenance operations. In order to achieve good perfor-
mances, long bearings lifetime and safe working, the working fluid must be
carefully selected in function of the operating parameters (a fundamental para-
meter is the ambient temperature range). In case of fire resistence fluid usage
, some limitation on pressure and speed can be required. Refer to hydraulic
fluid recommendations section for more information. If required please contact
Italgroup technical department for further information.

Motor parts Material


Motor shaft, rollers, pins, screws,
distributor bush, rotating distributor,
Steel
distributor joint, pistons, connecting
rod, ring for rod
Motor case, cylinders, motor flange,
Cast iron
distributor body
Distributor disk, piston shoes Bronze
Slippers Charged PTFE, PTFE
O-Rings Elastomer
Radial shaft seal rings Elastomer / charged PTFE

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 21
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

INSTRUCTIONS AND ADVICES


Bearings The bearing life depends by different factors, like bearing type, motor
speed, working pressure, external loads, duty cycle, fluid viscosity, oil
cleanliness, type and temperature.

Lifetime is measured by L10 which is called “theoretic lifetime”. It repre-


sents the number of cycles that 90% of identical bearings can effort at
the same load without showing wear and tear.

Please refer to bearing lifetime diagrams reported in the following pages


to obtain the theoretical bearing lifetime. The lifetimes diagrams shown
the L50, median or average lifetime, that can be considered as 5 times
L10.

Please note that the theoretical lifetime can be different from the real
lifetime, especially in case of heavy duty applications with continuous
work cycle.

Please contact Italgroup S.r.l. for more information.

Motor creep speed The hydraulic motor is able to hold the load acting as a brake (if proper
valves or circuit are considered and installed), but a certain creep spe-
ed is always present: this is typical of all brands hydraulic motors.

The motor creep speed depends by many factors, like operating condi-
tions (motor displacement and type, pressure load on the shaft, oil visco-
sity, type and temperature)

If creep speed is higher than desired value a negative brake can be


considered: Italgroup can supply negative brakes that can be fitted to
the hydraulic motor.

Please contact Italgroup S.r.l. for more information.

22 R8D rev.00 - Oct. 2018


SPECIAL FEATURES
Special features Marine painting

If needed, special painting or primers are available in order to guarantee


optimal protection against normal corrosion and marine environment cor-
rosion. The ordering code is MP. Please contact Italgroup S.r.l. for more
information.

Speedy-sleeve

A special inox sleeve is available upon request. In case the motor is used
in aggressive medias or environments, this can be very useful in order
to protect the motor shaft surface located in proximity of the motor shaft
seal. This improves the shaft and seal endurance respect to wear and
corrosion. The ordering code is SPSL. Please contact Italgroup S.r.l. for
more information.

High pressure shaft seal

Standard R8D motors are supplied with high pressure shaft seals, the
continuous drain pressure must be maximum 6 bar, whereas the peak
drain pressure must be maximum 10 bar. In case the drain line can or
must has a higher pressure, special shaft seals are available upon re-
quest. The ordering code is HPS. The drain pressure with HPS shaft seal
can reach 20-25 bar continuous pressure and 30 bar peak pressure. The
HPS shaft seal is bi-directional also, so it can be used for example in un-
derwater applications. Please contact Italgroup S.r.l. for more information.

Counterclockwise rotation

Standard R8D motors are supplied with clockwise distributor timing. Ple-
ase refer to the installation drawings of each section for more informa-
tion. With ordering code CCW the motor is supplied with counterclockwi-
se rotation timing. Contact Italgroup for more information.

Standard timing CCW timing

Oil inlet

Oil outlet

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 23
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

TROUBLESHOOTING
Problem Possible cause Solution
Cavitation Adopt an anti-cavitation system
Check and fix damaged
Mechanical vibrations
components
Excessive noises Check other components
Irregular pressure or flow (pump, valves, accumulators)
and check drain flow
Air bubbles in the circuit Bleed circuit
Overflow Check max allowed flow
Check relief valve pressure
Overpressure
setting
Choose the appropriate oil
Unit overheating Oil viscosity too low
according to the temperature
Undersized cooling system Improve cooling system
Overhaul the unit, fill with oil
Working without oil in the case
before start-up
Worn motor internal
Overhaul the motor
components
Motor internal seals worn Overhaul the motor
Anomalous drainage flow
Check drain port size, pres-
Excessive pressure in the mo-
sure and flow, check piping
tor case
connections
Pressure relief valve set Check relief valve pressure
incorrectly setting
Undersized motor displace- Replace with bigger displ.
Insufficient torque
ment motor
Pump not able to reach the
Check pump integrity
design pressure
Replace with smaller displ.
Oversized motor displacement
motor
Pump not able to reach the
Insufficient speed Check pump integrity
design flow
Undersized pump Improve pump output flow
Excessive drain flow Overhaul the motor
Seized motor flow distributor Overhaul the flow distributor
Motor internal seizure Overhaul the motor
Output shaft cannot rotate Check drain flow, overhaul the
Motor internal seals worn
motor
Air in the circuit Bleed the circuit

24 R8D rev.00 - Oct. 2018


Problem Possible cause Solution
Worn seals Replace seals
Check drain port size, pressure
Excessive pressure in the mo-
and flow, check piping con-
tor case
Oil leakage nections
Check drain port size, pressure
Burst motor shaft seal and flow, check piping con-
nections
Pipes incorrectly connected Check pipe connections
Incorrecte sense of rotation Incorrect rotating distributor Change rotating distributor
timing timing

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 25
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

LENGHT 1m = 39,3701 in MASS 1 kg = 2,2046 lb POWER 1 kW = 1,341 HP


= 3,2808 ft = 1,3596 CV
= 1,0936 yd FORCE 1N = 0,102 kgf 1 HP = 0,7457 kW
= 1000 mm = 0,2248 lbf = 1,0139 CV
1 in = 0,0833 ft 1 kgf = 2,205 lbf
= 25,4 mm = 9,806 N VOLUME 1 m3 = 1000 l
1 ft = 0,3048 m 1 lbf = 0,4536 kgf 1 l = 61,023 in3
= 0,3333 yd = 4,448 N = 0,264 galUS
3
= 12 in 1 in = 0,01639 l
1 yd = 0,9144 m PRESSURE 1 bar = 14,223 psi = 16,39 cm3
= 3 ft = 0,99 atm = 0,004326
galUS
= 36 in = 1,02 ata 1 galUS = 3,7879 l
1 km = 1000 m = 100000 Pa =231,15 in3
= 1093,6 yd = 100 kPa
= 0,6214 mile = 0,1 MPa TORQUE 1 Nm = 0,102 kgm
1 mile = 1,609 km 1 psi = 0,0703 bar = 0,7376 lbf ft
= 1760 yd 1 kgm = 9,806 Nm
FLOW 1 l/min = 0,264 gpm = 7,2325 lbf ft
SPEED 1 m/s = 3,6 km/h = 1000 cc/Rev 1 lbf ft = 0,1383 kgm
= 2,237 mph 1 gpm = 3,785 l/min = 1,3558 Nm
= 3,2808 ft/s = 3785 cc/min
3
1 km/h = 0,2778 m/s 1 m /s = 60000 l/min
= 0,6214 mph = 15852 gpm
= 0,9113 ft/s
1 mph = 1,609 km/h
= 0,447 m/s
= 1,467 ft/s
1 ft/s = 0,3048 m/s
= 1,0973 km/h
= 0,6818 mph

26 R8D rev.00 - Oct. 2018


R8D H2
R8D 300 H2 Pag. 28 - 29

R8D 300/GM2 H2 Pag. 30 - 31

R8D 300/S H2 Pag. 32 - 33

R8D H2 - PERFORMANCE CURVES Pag. 34 - 35

R8D H2 - ORDERING CODE Pag. 36

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 27
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D 300 H2
20
DRAIN PORT
14 3/8" BSP
164
9

N°2 PORTS
1" BSP

20

190-0,05
-0,15
~82

341
130
69

86

D40 (*)

N°5 MTG HOLES


MTG FACE

41
12,5 ON A 210 P.C.D.

77 141 68

Ø2
DRAIN PORT

10
3/8" BSP

TECHNICAL DATA
300
DISPLACEMENT [cc] 314
SPECIFIC TORQUE [Nm/bar] 5
MAX. CONT. PRESSURE [bar] 270
HYDROSTATIC TEST PRES- [bar] 420
SURE
MAX. CONT. SPEED [rpm] 900
PEAK SPEED (***) [rpm] 1100
MAX. CONT. POWER (****) [kW] 45
MAX. POWER [kW] 66
MAX. CASE PRESSURE [bar] 6
DRY WEIGHT [kg] 42
TEMPERATURE RANGE (**) [°C] -30÷70

- (*) The standard distributor (D40) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

28 R8D rev.00 - Oct. 2018


4141
41
41
41

10
MOUNTING FACE
MOUNTINGFACE
MOUNTING FACE
MOUNTINGFACE MOUNTING FACE

1010 10
MOUNTING FACE

10
MOUNTING FACE
MOUNTING FACE MOUNTING FACE
MOUNTING FACE

A2
79

79
57

45

57
38
A0

7979 79

7979 79
79

5757 57

5757 79
57
57

3838 38

45

57
38
M12x30
M12x30

6
M12x30

4545 45 6 6
M12x30
M12x30
M12x30 3232UNI
UNI221 221
M12x30

6
∅38
∅38 ±0,01
±0,01 UNI
UNI
328953
UNI -221
M12x30 8x32x38
8953 - 8x32x38

6
Available spline billet:
∅38±0,01 M12x30
M12x30 UNI 8953
32 - 8x32x38
UNI
DIN
DINISOISO - 8x32x38
1414- 221
8x32x38
∅38±0,01 DIN ISO 32
14 UNI 221
8x32x38
UNI 8953 - -8x32x38
∅38±0,01 UNI 8953 - 8x32x38

SB2
DIN ISO 14 - 8x32x38
DIN ISO 14 - 8x32x38

8
88
8
MOUNTING FACE
MOUNTINGFACE

8
MOUNTING FACE

48
36
A3
MOUNTING FACE
MOUNTING FACE MOUNTING FACE
MOUNTINGFACE
N40x3x12-9H
N40x3x12-9H MOUNTING FACE

4848 48
3636 36
N40x3x12-9H

48
DIN 5480
DIN5480

36
DIN 5480 MOUNTING FACE

Available spline bar:


N40x3x12-9H MOUNTING FACE

∅5555
N40x3x12-9H
55 5480
∅DIN
DIN 5480
79

∅55
57

∅55

B8076
38
7979 79
79

5757 57
57

3838 38

8
38

M12x30
M12x30
A1

88
M12x30

right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
8
MOUNTING FACE
MOUNTINGFACE M12x30
W40x3x12-8e
W40x3x12-8e

8
MOUNTING FACE M12x30
W40x3x12-8e
DIN 5480
DIN5480

48
36
DIN 5480
Available spline billet:

MOUNTING FACE W40x3x12-8e


MOUNTING FACE
A31 W40x3x12-8e
DIN 5480

4848 48
3636 36
DIN 5480

48
3636UNI 220
UNI220

36
SB22

36 UNI 220

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
Available spline bar:
∅55
∅55
36
∅55UNI 220
36 UNI 220
∅55
∅55
SHAFTS

B8078

29
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H2/GM2
N°5 MTG HOLES
DRAIN PORT
18 12,5 ON A 250 P.C.D. 164 3/8" BSP
4

N°2 PORTS
1" BSP

150-0,05
-0,15
130

280

341
250
69

86
D40 (*)

41 5
DRAIN PORT
3/8" BSP
MTG FACE

68
77 159

TECHNICAL DATA
300
DISPLACEMENT [cc] 314
SPECIFIC TORQUE [Nm/bar] 5
MAX. CONT. PRESSURE [bar] 270
HYDROSTATIC TEST PRES- [bar] 420
SURE
MAX. CONT. SPEED [rpm] 900
PEAK SPEED (***) [rpm] 1100
MAX. CONT. POWER (****) [kW] 45
MAX. POWER [kW] 66
MAX. CASE PRESSURE [bar] 6
DRY WEIGHT [kg] 42
TEMPERATURE RANGE (**) [°C] -30÷70

- (*) The standard distributor (D40) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

30 R8D rev.00 - Oct. 2018


54
54
54
54

16
54
MOUNTING FACE
MOUNTING FACE

16 16
MOUNTING FACE
MOUNTING FACE

1616
MOUNTING
MOUNTING FACE
FACE
MOUNTING
MOUNTING FACE
FACE MOUNTING FACE
MOUNTING FACE

72

67

A2

72
55

66
72 72

48
67 67

72 72
55 55

66 66
A0
7272

6767

7272
48 48

6666
4848
M20x40 M16x32
M16x32
M20x40
M16x32 220

Available spline billet:


M20x40m6 M16x32
36
36 UNI
UNI 220

5555 55 55 5
M20x40
∅50
∅ 50 m6
M20x40 M16x32
UNI 8953
UNI 8953 - 8x36x40
- 8x36x40
∅ 36
36 UNI
UNI 220
50 m6
∅50 m6 DIN ISO
DIN ISO 14 8x36x40
14 -- 220
8x36x40

SB3
∅50 m6 UNI 8953
36 UNI- 8x36x40
220
UNI 8953 - 8x36x40
DIN
UNIISO
DIN 8953
ISO 14 8x36x40
14- --8x36x40
8x36x40
DIN ISO 14 - 8x36x40

88 88 8
MOUNTING FACE
MOUNTING FACE

48
18
A3
MOUNTING
MOUNTING FACE
FACE

48 48
N40x3x12-9H
N40x3x12-9H
MOUNTING FACE

18 18

4848
DIN 5480
DIN 5480
N40x3x12-9H FACE

Available spline bar:


N40x3x12-9H MOUNTING
MOUNTING FACE

1818
∅DIN
∅ 55 5480
N40x3x12-9H
55
DIN 5480 MOUNTING
MOUNTING FACE
FACE
∅DIN 5480
55
∅55 MOUNTING FACE

B8076
61

∅55
57

38
61 61

57 57

38 38
6161

5757

3838

M12x30
M12x30
A1

M12x30

right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
M12x30

88 88 8
FACE W40x3x12-8e
W40x3x12-8e
Available spline billet:

48
MOUNTING
MOUNTING FACE M12x30
DIN 5480
DIN 5480
W40x3x12-8e

18
MOUNTING W40x3x12-8e

48 48
MOUNTING FACE
FACE
36 MOUNTING
220 FACE A31 DIN
W40x3x12-8e
DIN 5480
5480
SB22

4848
18 18
36 UNI
UNI 220
DIN 5480

1818

Available spline bar:


∅∅55
3655UNI 220
36 UNI 220

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
36
∅ UNI 220
55
∅55
∅55

B8078
SHAFTS

31
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H2/S
N°5 MTG HOLES
DRAIN PORT
18 12,5 ON A 195 P.C.D. 164 3/8" BSP
6
19

N°2 PORTS
1" BSP

150-0,05
-0,15
130

280

341
195
69

86
D40 (*)

41 5
DRAIN PORT
3/8" BSP
MTG FACE

68
77 159

TECHNICAL DATA
300
DISPLACEMENT [cc] 314
SPECIFIC TORQUE [Nm/bar] 5
MAX. CONT. PRESSURE [bar] 270
HYDROSTATIC TEST PRES- [bar] 420
SURE
MAX. CONT. SPEED [rpm] 900
PEAK SPEED (***) [rpm] 1100
MAX. CONT. POWER (****) [kW] 45
MAX. POWER [kW] 66
MAX. CASE PRESSURE [bar] 6
DRY WEIGHT [kg] 42
TEMPERATURE RANGE (**) [°C] -30÷70

- (*) The standard distributor (D40) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

32 R8D rev.00 - Oct. 2018


54
54
54
54

16
54
MOUNTING FACE
MOUNTING FACE

16 16
MOUNTING FACE
MOUNTING FACE

1616
MOUNTING
MOUNTING FACE
FACE
MOUNTING
MOUNTING FACE
FACE MOUNTING FACE
MOUNTING FACE

72

67

A2

72
55

66
72 72

48
67 67

72 72
55 55

66 66
A0
7272

6767

7272
48 48

6666
4848
M20x40 M16x32
M16x32
M20x40
M16x32 220

Available spline billet:


M20x40m6 M16x32
36
36 UNI
UNI 220

5555 55 55 5
M20x40
∅50
∅ 50 m6
M20x40 M16x32
UNI 8953
UNI 8953 - 8x36x40
- 8x36x40
∅ 36
36 UNI
UNI 220
50 m6
∅50 m6 DIN ISO
DIN ISO 14 8x36x40
14 -- 220
8x36x40

SB3
∅50 m6 UNI 8953
36 UNI- 8x36x40
220
UNI 8953 - 8x36x40
DIN
UNIISO
DIN 8953
ISO 14 8x36x40
14- --8x36x40
8x36x40
DIN ISO 14 - 8x36x40

88 88 8
MOUNTING FACE
MOUNTING FACE

48
18
A3
MOUNTING
MOUNTING FACE
FACE

48 48
N40x3x12-9H
N40x3x12-9H
MOUNTING FACE

18 18

4848
DIN 5480
DIN 5480
N40x3x12-9H FACE

Available spline bar:


N40x3x12-9H MOUNTING
MOUNTING FACE

1818
∅DIN
∅ 55 5480
N40x3x12-9H
55
DIN 5480 MOUNTING
MOUNTING FACE
FACE
∅DIN 5480
55
∅55 MOUNTING FACE

B8076
61

∅55
57

38
61 61

57 57

38 38
6161

5757

3838

M12x30
M12x30
A1

M12x30

right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
M12x30

88 88 8
FACE W40x3x12-8e
W40x3x12-8e
Available spline billet:

48
MOUNTING
MOUNTING FACE M12x30
DIN 5480
DIN 5480
W40x3x12-8e

18
MOUNTING W40x3x12-8e

48 48
MOUNTING FACE
FACE
36 MOUNTING
220 FACE A31 DIN
W40x3x12-8e
DIN 5480
5480
SB22

4848
18 18
36 UNI
UNI 220
DIN 5480

1818

Available spline bar:


∅∅55
3655UNI 220
36 UNI 220

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
36
∅ UNI 220
55
∅55
∅55

B8078
SHAFTS

33
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H2 - PERFORMANCE CURVES


R8D 300 H2

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

34 R8D rev.00 - Oct. 2018


CREEP SPEED - VOLUMETRIC EFFICIENCY
50 100 300 600

15
300

creep speed [rpm]


200
25
10

10 rpm

0
0 1 2 3 60 70 80 90 100
external leakage [l/min] volumetric efficiency [%]

0 50 100 150 200 250


pressure [bar] Reference viscosity: 40 cSt

Example:
We suppose (300 cc): p=200 [bar], we obtain: external leakage 2,9 [l/min], shaft creep speed 12,7 [rpm].
If we suppose (300 cc): p=200 [bar] and n=300 [rpm] we obtain a volumetric efficiency of 96%;

BEARING LIFE

n=25 n=50 n=100


250 bar
n=200
EX 2
n=300
n=500 180 bar
n=1000
EX 1 120 bar

60 bar

a=1
L50h 5 4 3 200000 9 8 7 6 5 4 3 2 10 4 5000 50
mm a=100 mm
5
10 a=75 mm
5 kN

Fr Fr
Sh
aft

10 kN
str
es

Fr=radial load a=
s li

50
mi

a=distance of radial load from mounting face mm


15 kN
t

n=shaft speed [rpm]

20 kN
a
Reference viscosity: 40 cSt

Example:
We suppose (EX1): p=120 [bar], n=50 [rpm]; we obtain an average lifetime of 200000 [h].
If we suppose (EX2): Fr=10 [kN], a=50 [mm], n=50 [rpm] and p=250 [bar] we obtain an average lifetime
of 12500 [h].

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 35
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H2 - ORDERING CODE

R8D -- -- H2 -- -- -- -- SB -

TACHOMETER

TA SPECIAL SPLINE
DISPLACEMENT INTERCHANGEABILITY SHAFT FEATURES BILLET
TB
300 /GM2 A0 MP SB2
SERIE
TT1
/S A1 SPSL SB3
H2 TQ1
A2 HPS SB22
EST
A3 CCW See pag. 181-185
EST30
A31 See pag. 23
EST31
Z--
EST32
Italgroup
EST33 internal code
DISTRIBUTOR See pag. 177-180
D31B D31BJ
D36B D36BJ
D310B D310BJ
D40 D40J
D47 D47J
D416 D416J
See pag. 174-175

EXAMPLES:

R8D 300/GM2 H2 A1 D40


R8D 300 H2 A2 D310B
R8D 300/GM2 H2 A0 D47 CCW

36 R8D rev.00 - Oct. 2018


R8D H3
R8D H3 Pag. 38 - 39

R8D H3/C Pag. 40 - 41

R8D H3/RM Pag. 42 - 43

R8D H3/H4C Pag. 44 - 45

R8D H3 - PERFORMANCE CURVES Pag. 46 - 49

R8D H3 - ORDERING CODE Pag. 50

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 37
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H3
19 DRAIN PORT
190 1/2" BSP
14

N°2 PORTS
1" BSP

- 0,05
230 - 0,15
130

150

386
24
69

95

D40 (*)
10 
41 25
N°5 MTG. HOLES 4
MTG FACE

15 ON A 254 P.C.D.

77 165 68
DRAIN PORT
1/2" BSP

TECHNICAL DATA
350 400 450 500 600 700
DISPLACEMENT [cc] 342 398 452 492 594 707
SPECIFIC TORQUE [Nm/bar] 5.4 6.3 7.2 7.8 9.5 11.2
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 170
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 850 750 650 600 500 440
PEAK SPEED (***) [rpm] 950 860 760 690 570 500
MAX. CONT. POWER (****) [kW] 85 85 85 85 85 78
MAX. POWER [kW] 130 130 130 130 130 118
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6
DRY WEIGHT [kg] 68 68 68 68 68 68
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D40) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

38 R8D rev.00 - Oct. 2018


SHAFTS
MOUNTING FACE

221 ISO 14 - 8x36x42

MOUNTING FACE
UNI 8953 8x36x42
36 UNI 221

50 6.5
MOUNTING FACE
MOUNTING FACE

M14x30

DIN ISO 14 - 8x36x42


DIN ISO 14 - 8x36x42

MOUNTING FACE
MOUNTING FACE
63

M14x30
A0 UNI 8953 8x36x42 A2
8953 8x36x42

43 12
36 UNI 221
36 UNI DIN

50 50 6.5 6.5
M14x30
M14x30

∅42±0,01
45
63 63

M14x30
M14x30
UNI

43 43 12 12

90
63

∅42±0,01
∅42±0,01
45
45
90

90 90
63 63
90 90
Available spline billet: SB3

A3
MOUNTING FACE

36 UNI 220
MOUNTING FACE
MOUNTING FACE

36 UNI 220 ∅60

36 UNI 220
∅60
∅60

8
32
48

Available 8 bar:
8 spline B8078
32 32
48 48

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 39
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H3/C
DRAIN PORT
190 1/2" BSP
12

N°2 PORTS
1" BSP

190-0,05
-0,15
130

285

386
95
69

24

D40 (*)
Ø
26
6
41
MTG FACE

N°5 MTG. HOLES


13 ON A 266 P.C.D.
77 177 68
DRAIN PORT
Available distributor flange: FL2 1/2" BSP
Refer to page 186-187
(distributor fitting D47)

TECHNICAL DATA
350 400 450 500 600 700
DISPLACEMENT [cc] 342 398 452 492 594 707
SPECIFIC TORQUE [Nm/bar] 5.4 6.3 7.2 7.8 9.5 11.2
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 170
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 850 750 650 600 500 440
PEAK SPEED (***) [rpm] 950 860 760 690 570 500
MAX. CONT. POWER (****) [kW] 85 85 85 85 85 78
MAX. POWER [kW] 130 130 130 130 130 118
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6
DRY WEIGHT [kg] 68 68 68 68 68 68
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D40) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

40 R8D rev.00 - Oct. 2018


SHAFTS

B8x46x54 DIN 5463


B8x46x54 DIN 5463
46 UNI 222
46 UNI 222
MOUNTING FACE

MOUNTING FACE

W55x3x17-8e
MOUNTING FACE

MOUNTING FACE
DIN 5463

W55x3x17-8e
DIN 5480
B8x46x54 M12x25

DIN 5480 M12x25

DIN 5480
M12x25

M12x25
46 UNI 222
MOUNTING FACE

MOUNTING FACE
74 74

W55x3x17-8e
A1 74 A11 74
M12x25

M12x25
56.5 60
56.5 60
74
74 74
74
56.5
56.5 60
60

97 97 97 97

97
97 97
97

Available spline billet: SB5 Available spline billet: SB30

A2 A3
MOUNTING FACE
MOUNTING FACE

MOUNTING FACE
MOUNTING FACE

N47x2x22-9H
N47x2x22-9H

70 70 2 2
DIN 5480
DIN 5480
MOUNTING FACE

M14x30

MOUNTING FACE
M14x30

16
∅60

16
∅60
N47x2x22-9H

70
70 22
DIN 5480
M14x30
59

∅55 m6
59

16
16
∅55 m6

∅60
59

∅55 m6

5
5
74 28
74 28
97 43
97 43
55
74
74 28
28
97
97 43
43

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 41
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H3/RM
190
DRAIN PORT
1/2" BSP
95
19

N°2 PORTS
1" BSP

180-0,05
-0,15
130

122

290

386
36
69

D40 (*)

11 N°5 MTG. HOLES


41 18 ON A 260 P.C.D.
MTG FACE

DRAIN PORT
77 177 1/2" BSP

TECHNICAL DATA
350 400 450 500 600 700
DISPLACEMENT [cc] 342 398 452 492 594 707
SPECIFIC TORQUE [Nm/bar] 5.4 6.3 7.2 7.8 9.5 11.2
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 170
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 850 750 650 600 500 440
PEAK SPEED (***) [rpm] 950 860 760 690 570 500
MAX. CONT. POWER (****) [kW] 85 85 85 85 85 78
MAX. POWER [kW] 130 130 130 130 130 118
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6
DRY WEIGHT [kg] 68 68 68 68 68 68
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D40) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

42 R8D rev.00 - Oct. 2018


58,5
58,5 58,5
58,5
MOUNTING FACE

A2
MOUNTING

14 14
MOUNTING
FACE FACE

14 14
MOUNTING FACE MOUNTING FACE
MOUNTING
MOUNTING
FACE FACE
MOUNTING FACE

130130

Available spline billet:


100100

130130
71 71
A0
100100

130130
30 30
71 71

90 90

100100

130130
30 30
1/2"-20 UNF 2B

SB21

90 90
BS 3550 1963

100100
30 30
BS 3550 1/2"-201/2"-20
UNF 2BUNF 2B
ASA.B.5.15.1960
BS1963
3550 1963

30 30
6
ASA.B.5.15.1960
PITCH 8/16 Z=17 1/2"-20 UNF 2B

6 6
1/2"-20 UNF-2B BS 3550 1963
ASA.B.5.15.1960
PITCH 8/16 Z=17

6
1/2"-201/2"-20
UNF-2BUNF-2B ASA.B.5.15.1960
PITCH 8/16 Z=17
∅55 ±0,01 PITCH 8/16 Z=17
1/2"-20 UNF-2B
∅55±0,01
∅55±0,01
∅55±0,01

53,5
53,5 53,5

A21
53,5
MOUNTING FACE

14 14
MOUNTING

14 14
MOUNTING FACE MOUNTING
FACE FACE
MOUNTING
MOUNTING
FACE FACE MOUNTING FACE
MOUNTING FACE
130130
A1

Available spline billet:


100100

130130

130130
71 71

90 90

100100
100100

30 30

130130
71 71

right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
90 90

100100
30 30

30 30
1/2"-20 UNF 2B
SB30

30 30
W55x3x17-8e 1/2"-201/2"-20
UNF 2BUNF 2B

5
5 5
1/2"-20 UNF-2B W55x3x17-8e
DIN 5480
W55x3x17-8e 1/2"-20 UNF 2B

5
1/2"-201/2"-20
UNF-2BUNF-2B DIN 5480
W55x3x17-8e
DIN 5480
∅50 ±0,01
1/2"-20 UNF-2B DIN 5480

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
∅50±0,01
∅50±0,01
∅50±0,01
SHAFTS

43
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H3/H4C
DRAIN PORT
190 1/2" BSP
19

N°2 PORTS
1" BSP

220-0,05
-0,15
130

150

336

386
69

95
36
Ø290

D40 (*)
10

41
MTG FACE

N°5 MTG. HOLES


13 ON A 290 P.C.D.
77 177 68
DRAIN PORT
Available distributor flange: FL2 1/2" BSP

Refer to page 186-187


(distributor fitting D47)

TECHNICAL DATA
350 400 450 500 600 700
DISPLACEMENT [cc] 342 398 452 492 594 707
SPECIFIC TORQUE [Nm/bar] 5.4 6.3 7.2 7.8 9.5 11.2
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 170
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 850 750 650 600 500 440
PEAK SPEED (***) [rpm] 950 860 760 690 570 500
MAX. CONT. POWER (****) [kW] 85 85 85 85 85 78
MAX. POWER [kW] 130 130 130 130 130 118
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6
DRY WEIGHT [kg] 68 68 68 68 68 68
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D40) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

44 R8D rev.00 - Oct. 2018


SHAFTS

A32
MOUNTING FACE

18 27
M8

∅75

10
N55x3x17-9H
DIN 5480

43

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 45
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H3 - PERFORMANCE CURVES


R8D 350 H3

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 400 H3

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

46 R8D rev.00 - Oct. 2018


R8D 450 H3

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 500 H3

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 47
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H3 - PERFORMANCE CURVES


R8D 600 H3

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 700 H3

230 bar

200 bar

170 bar
150 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

48 R8D rev.00 - Oct. 2018


CREEP SPEED - VOLUMETRIC EFFICIENCY
50 100 300
15
350 600
200
400

creep speed [rpm]


25
450
500
10
600
700 cc 10 rpm

0
0 1 2 3 4 60 70 80 90 100
external leakage [l/min] volumetric efficiency [%]

0 50 100 150 200 250


pressure [bar] Reference viscosity: 40 cSt

Example:
We suppose (500 cc): p=175 [bar], we obtain: external leakage 3 [l/min], shaft creep speed 10 [rpm].
If we suppose (500 cc): p=175 [bar] and n=200 [rpm] we obtain a volumetric efficiency of 95%;

BEARING LIFE
Reference displacement 500 cc
n=50 n=100

n=200
r
n=400 250 ba
n=600 r
180 ba
EX 2
120 bar
EX 1 60 bar

a=1
L50h 5 4 3 200000 9 8 7 6 5 4 3 2 10 4 5000 50
mm a=100 mm
5
10 a=75 mm
10 kN

Fr Fr
Sh
aft
str

20 kN
es

Fr=radial load a=
s li

50
mi

a=distance of radial load from mounting face mm


t

n=shaft speed [rpm] 30 kN

35 kN
a
Reference viscosity: 40 cSt

Example:
We suppose (EX1): p=120 [bar], n=400 [rpm]; we obtain an average lifetime of 53000 [h].
If we suppose (EX2): Fr=9 [kN], a=75 [mm], n=100 [rpm] and p=180 [bar] we obtain an average lifetime
of 42000 [h].

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 49
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H3 - ORDERING CODE

R8D -- -- H3 -- -- -- -- SB -

TACHOMETER

TA SPECIAL SPLINE
DISPLACEMENT INTERCHANGEABILITY SHAFT FEATURES BILLET
TB
350 /C A0 A1 MP SB3
SERIE
TT1
400 /RM A11 A2 SPSL SB5
H3 TQ1
450 /H4C A21 A3 HPS SB21
EST
500 A32 CCW SB30
EST30
600 See pag. 23 See pag. 181-185
EST31
700
Z--
EST32
Italgroup
EST33 internal code
DISTRIBUTOR See pag. 177-180
D31B D31BJ
D36B D36BJ
D310B D310BJ
D40 D40J
D47 D47J
D416 D416J
See pag. 174-175

EXAMPLES:

R8D 600 H3 A2 D416


R8D 450/C H3 A1 D40 CCW SB5
R8D 600 H3 A0 D40 EST31

50 R8D rev.00 - Oct. 2018


R8D H4
R8D H4 Pag. 52 - 53

R8D H4/C Pag. 54 - 55

R8D H4/B45 Pag. 56 - 57

R8D H4/GM4 Pag. 58 - 59

R8D H4/S Pag. 60 - 61

R8D H4/SB506 Pag. 62 - 63

R8D H4 - PERFORMANCE CURVES Pag. 64 - 68

R8D H4 - ORDERING CODE Pag. 69

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 51
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H4
28 DRAIN PORT
224
16 1/2" BSP

N°2 PORTS
1" BSP

- 0,05
256 - 0,15
130

112
160

452
110
69

D40 (*)


30
N°5 MTG HOLES 0
41 14 16,5 ON A 300 P.C.D.

68
MTG FACE

77 179 DRAIN PORT


1/2" BSP

TECHNICAL DATA
500 600 700 800 850 900 1000 1250
DISPLACEMENT [cc] 493 584 714 792 847 904 992 1247
SPECIFIC TORQUE [Nm/bar] 7.8 9.3 11.4 12.6 13.5 14.4 15.8 19.8
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 270 200
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 700 700 500 450 420 400 355 280
PEAK SPEED (***) [rpm] 800 800 580 530 490 460 405 320
MAX. CONT. POWER (****) [kW] 130 130 130 130 130 130 130 102
MAX. POWER [kW] 160 160 160 160 160 160 160 130
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6 6
DRY WEIGHT [kg] 92 92 92 92 92 92 92 92
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D40) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

52 R8D rev.00 - Oct. 2018


14
53,5
53,5
53,5
53,5 MOUNTING FACE

14
14
1414
MOUNTING FACE
MOUNTING
MOUNTING FACE
MOUNTING FACE
FACE

104
70
60
MOUNTING FACE

30

104
M16

104
605

104
60
A2

70
60
MOUNTING FACE
MOUNTING

1047070
104

60
∅50±0,01 MOUNTING FACE
FACE

30
MOUNTING FACE

70

70 3030
50

30
Available spline billet:
30
M16M16

5
M16
57 M16

104
50±0,01 46 UNI 220

555
±0,01

104
50 ±0,01 M16

104
70
∅∅ ∅

70

SB4
50±0,01

104
∅ 50 UNI 8953 - 8x46x50

50
70
50
70
50

30
30

14
A0

50
DIN ISO 14 - 8x46x50

3030
57 57
57
57 MOUNTING FACE 46 46 UNI 220 M16
46 UNI
UNI 220
220 M16
M16
UNI
UNI 46
8953UNI
8953
- 220
- 8x46x50
8x46x50 M16
8x46x50

14
UNI
UNI 8953
8953 -- 8x46x50

14
DIN
DIN ISOISO
14 14 - 8x46x50

14
DIN ISO 14 -- 8x46x50
8x46x50

14
DIN ISO 14 - 8x46x50
MOUNTING FACE
MOUNTING
MOUNTING FACE
MOUNTING FACE
FACE

122
90
80

30
MOUNTING FACE

122
M14

122
805

122
80

90
80

1229090
80
∅54 f7

30
90 30
MOUNTING FACE

30
MOUNTING

A21
MOUNTING FACE
FACE

30
124
M14M14 MOUNTING FACE

5
M14
90

M14
65

555
∅54 f7
54 f7
∅∅54 f7
30

∅54 f7

22
124

Available spline billet:


124
124
46 UNI 221
90

10
90

M16
124
90
65
65
90

UNI 8953 - 8x46x54


65

MOUNTING FACE
65

30
30

SB5 DIN ISO 14 - 8x46x54


30

22
30

22
22
46 UNI 221

22
46

10
52
A1

M16

10
M16

43
46 UNI
UNI 221221

10
UNI46 UNI
8953 221
- 8x46x54 M16

10
UNI M16

right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
MOUNTING FACE
MOUNTING UNI 8953 8x46x54
MOUNTING FACE
FACE UNI
DIN
DIN 8953
8953 --- 8x46x54
ISO ISO
14 14 - 8x46x54
8x46x54
MOUNTING FACE DIN ISO 14 --8x46x54
8x46x54
M10 DIN ISO 14 - 8x46x54

52
52
43
43

52
43
53x58

52
43
DIN 5482
∅75 M10
M10

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
53x58 M10
M10
53x58
53x58
53x58
A3
DIN
DIN 5482
DIN 5482
DIN 5482
5482
∅75
SHAFTS

75
∅∅75

53
∅75
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H4/C
15 DRAIN PORT
110 1/2" BSP

N°2 PORTS
1" BSP

- 0,05
220 - 0,15

452
130

324
69

42

D40 (*)
2
90

224
MTG FACE

41
DRAIN PORT
77 195 1/2" BSP
68
N°5 MTG HOLES
13 ON A 290 P.C.D.
Available distributor flange: FL2
Refer to page 186-187
(distributor fitting D47)

TECHNICAL DATA
500 600 700 800 850 900 1000 1250
DISPLACEMENT [cc] 493 584 714 792 847 904 992 1247
SPECIFIC TORQUE [Nm/bar] 7.8 9.3 11.4 12.6 13.5 14.4 15.8 19.8
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 270 200
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 700 700 500 450 420 400 355 280
PEAK SPEED (***) [rpm] 800 800 580 530 490 460 405 320
MAX. CONT. POWER (****) [kW] 130 130 130 130 130 130 130 102
MAX. POWER [kW] 160 160 160 160 160 160 160 130
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6 6
DRY WEIGHT [kg] 92 92 92 92 92 92 92 92
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D40) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

54 R8D rev.00 - Oct. 2018


MOUNTING FACE
MOUNTING FACE
MOUNTINGFACE
MOUNTING FACE
MOUNTINGFACE

117
117
117
117
117
8181
818181
6262
626262

2525
252525

66
666
M12
MOUNTING FACE M12
M12
MOUNTING FACE
MOUNTINGFACE

Available spline billet:


M12
M12

A0
MOUNTING FACE
MOUNTINGFACE
52 UNI 222

4343
434343
222

2828
282828
52
52UNI
UNI222

SB16
52
52UNI 222
UNI222
N55x3x17-9H
N55x3x17-9H
N55x3x17-9H
DIN 5480
N55x3x17-9H
N55x3x17-9H MOUNTING FACE
DIN 5480
DIN5480 MOUNTING FACE
MOUNTINGFACE

A3
DIN 5480
DIN5480 MOUNTING FACE
MOUNTINGFACE
75
75
∅∅
∅75
∅75
∅75

117
117
117
117
117
8181
818181
6262
626262

2525
252525
M12
M12
M12
M12
M12
W60x3x18-8e
W60x3x18-8e
W60x3x18-8e
A11

DIN 5480
W60x3x18-8e
W60x3x18-8e
DIN 5480
DIN5480
DIN 5480
DIN5480

1818
181818
64
64
64

77
777
64
64
MOUNTING FACE
MOUNTING FACE
MOUNTINGFACE
MOUNTING FACE
MOUNTINGFACE
1818
181818

5050
505050
MOUNTING FACE

2828
282828
MOUNTING FACE
MOUNTINGFACE
M8 MOUNTING FACE
MOUNTINGFACE
M8
M8
N47x2x22-9H M8
M8

A31
N47x2x22-9H
N47x2x22-9H

right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
DIN 5480
N47x2x22-9H
N47x2x22-9H
DIN 5480
DIN5480
DIN 5480
DIN5480 75
101

75
∅∅
101

∅75
101

75
101

∅∅75
101
7878
787878
7070
707070

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
A2

M12x25
M12x25
M12x25
44
444

M12x25
M12x25
∅∅6060k6k6
SHAFTS

∅60 k6

55
∅∅6060k6k6
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H4/B45
36
224 DRAIN PORT
31 1/2" BSP

N°2 PORTS
1" BSP

0,15
225,4 -- 0,05
130

180

452
110
26
69

D40 (*)


N°5 MTG HOLES

30
5
41 12 18 ON A 305 P.C.D.

68
MTG FACE

77 179 DRAIN PORT


1/2" BSP

TECHNICAL DATA
500 600 700 800 850 900 1000 1250
DISPLACEMENT [cc] 493 584 714 792 847 904 992 1247
SPECIFIC TORQUE [Nm/bar] 7.8 9.3 11.4 12.6 13.5 14.4 15.8 19.8
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 270 200
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 700 700 500 450 420 400 355 280
PEAK SPEED (***) [rpm] 800 800 580 530 490 460 405 320
MAX. CONT. POWER (****) [kW] 130 130 130 130 130 130 130 102
MAX. POWER [kW] 160 160 160 160 160 160 160 130
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6 6
DRY WEIGHT [kg] 92 92 92 92 92 92 92 92
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D40) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

56 R8D rev.00 - Oct. 2018


SHAFTS

A1 A11
MOUNTING FACE

MOUNTING FACE
1/2"-20 UNF 2B

1/2"-20 UNF 2B
100 100
71 71

32 32
PITCH 8/16 Z=17
ASA.B.5.15.1960
BS 3550 1963

W55x3x17-8e
142 142

DIN 5480
Available spline billet: SB21 Available spline billet: SB30

A2
MOUNTING FACE

1/2"-20 UNF-2B

88 5
14
∅55±0,01
58,5

30

100
139

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 57
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H4/GM4
DRAIN PORT
N°5 MTG HOLES 223 1/2" BSP
37
18,5 ON A 310 P.C.D.
18

N°2 PORTS
1" BSP

265-0,05
-0,15

452
130

343
310
69

D40 (*)

0
11
6
41
DRAIN PORT
MTG FACE

1/2" BSP 68
77 216

TECHNICAL DATA
500 600 700 800 850 900 1000 1250
DISPLACEMENT [cc] 493 584 714 792 847 904 992 1247
SPECIFIC TORQUE [Nm/bar] 7.8 9.3 11.4 12.6 13.5 14.4 15.8 19.8
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 270 200
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 700 700 500 450 420 400 355 280
PEAK SPEED (***) [rpm] 800 800 580 530 490 460 405 320
MAX. CONT. POWER (****) [kW] 130 130 130 130 130 130 130 102
MAX. POWER [kW] 160 160 160 160 160 160 160 130
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6 6
DRY WEIGHT [kg] 92 92 92 92 92 92 92 92
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D40) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

58 R8D rev.00 - Oct. 2018


SHAFTS

A0 A1
- 8x56x65
- 8x56x65
MOUNTING FACE

MOUNTING FACE
DIN ISO 14 - 8x56x65

W65x3x20-8e
8x56x65
M20 56 UNI 221
MOUNTING FACE

MOUNTING FACE

DIN 5480
W65x3x20-8e
8953221

DIN 5480
ISO- 14
56 UNI
M20

M20
90 90
8953

M20
90 90
UNI

61 61
DIN
UNI

61 61

40 40
90 40 40
90
90 90
Available spline billet: SB17 Available spline billet: SB23

A2 A3 A31
MOUNTING FACE

MOUNTING FACE

MOUNTING FACE
MOUNTING FACE

MOUNTING FACE

MOUNTING FACE

90
90
70 5
20 70 5 18 18
M30x55

14 14
M8

M8

20 18 18
∅70 M30x55

14 14
M8

M8
m6
74,5

∅70 m6
74,5

∅75

∅75
∅75

∅75
DIN 5482

90 10 10
N55x3x17-9H

55x50
DIN 5480

DIN 5482

90 10 10
N55x3x17-9H

53 53
55x50
DIN 5480

53 53

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 59
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H4/S
DRAIN PORT
223 1/2" BSP
42 N°5 MTG HOLES 16,5
ON A 245 P.C.D.
8

N°2 PORTS
1" BSP

175-0,05
-0,15

452
130

326
245
69

D40 (*)

0
11
DRAIN PORT
MTG FACE

41 1/2" BSP 68

77 221

TECHNICAL DATA
500 600 700 800 850 900 1000 1250
DISPLACEMENT [cc] 493 584 714 792 847 904 992 1247
SPECIFIC TORQUE [Nm/bar] 7.8 9.3 11.4 12.6 13.5 14.4 15.8 19.8
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 270 200
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 700 700 500 450 420 400 355 280
PEAK SPEED (***) [rpm] 800 800 580 530 490 460 405 320
MAX. CONT. POWER (****) [kW] 130 130 130 130 130 130 130 102
MAX. POWER [kW] 160 160 160 160 160 160 160 130
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6 6
DRY WEIGHT [kg] 92 92 92 92 92 92 92 92
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D40) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

60 R8D rev.00 - Oct. 2018


SHAFTS

A0 A1
- 8x56x65
- 8x56x65

MOUNTING FACE
MOUNTING FACE

DIN ISO 14 - 8x56x65

W65x3x20-8e
8x56x65
M20 56 UNI 221

MOUNTING FACE
MOUNTING FACE

DIN 5480
W65x3x20-8e
8953221

DIN 5480
ISO- 14
56 UNI
M20

M20
85 85
8953

M20
6185 6185
UNI
DIN
UNI

61 61

40 40
90 40 40
90
90 90
Available spline billet: SB17 Available spline billet: SB23

A2 A3 A31
MOUNTING FACE

MOUNTING FACE

MOUNTING FACE
MOUNTING FACE

MOUNTING FACE

MOUNTING FACE

85
85
70 5
20 70 5 18 18
M30x55

9 9
M8

M8

20 18 18
∅70 M30x55

9 9
M8

M8
m6
74,5

∅70 m6
74,5

∅75

∅75
∅75

∅75
DIN 5482

90 10 10
N55x3x17-9H

55x50
DIN 5480

DIN 5482

90 10 10
N55x3x17-9H

53 53
55x50
DIN 5480

53 53

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 61
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H4/SB506
28 DRAIN PORT
223 1/2" BSP
16

N°2 PORTS
1" BSP

260-0,05
-0,15
130

112
160

452
110
26
69

D40 (*)

Ø
N°5 MTG HOLES

30
16,5 ON A 300 P.C.D.

0
41 14

68
MTG FACE

77 179 DRAIN PORT


1/2" BSP

TECHNICAL DATA
500 600 700 800 850 900 1000 1250
DISPLACEMENT [cc] 493 584 714 792 847 904 992 1247
SPECIFIC TORQUE [Nm/bar] 7.8 9.3 11.4 12.6 13.5 14.4 15.8 19.8
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 270 200
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 700 700 500 450 420 400 355 280
PEAK SPEED (***) [rpm] 800 800 580 530 490 460 405 320
MAX. CONT. POWER (****) [kW] 130 130 130 130 130 130 130 102
MAX. POWER [kW] 160 160 160 160 160 160 160 130
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6 6
DRY WEIGHT [kg] 92 92 92 92 92 92 92 92
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D40) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

62 R8D rev.00 - Oct. 2018


SHAFTS

A0 A01
MOUNTING FACE

MOUNTING FACE

1/2"-20 UNF-2B
85 85
M16

55 60
Z=20, PRESSURE ANGLE 20°

Z=20, PRESSURE ANGLE 20°


30 32
PITCH DIAMETER ∅50

PITCH DIAMETER ∅50


INVOLUTE SPLINE

INVOLUTE SPLINE
MODULE 2.5 mm

MODULE 2.5 mm
136 126
MOUNTING FACE

A22

105 7.5
15
M16
∅60±0,01
64

30
120
153

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 63
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H4 - PERFORMANCE CURVES


R8D 500 H4

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 600 H4

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

64 R8D rev.00 - Oct. 2018


SHAFTS
R8D 700 H4

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 800 H4

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 65
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H4 - PERFORMANCE CURVES


R8D 850 H4

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 900 H4

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

66 R8D rev.00 - Oct. 2018


R8D 1000 H4

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 1250 H4

270 bar

230 bar
200 bar
180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 67
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H4 - PERFORMANCE CURVES


CREEP SPEED - VOLUMETRIC EFFICIENCY

500 600 50 100 300 600

10
700 800 200

creep speed [rpm]


8 25
900
850
1000
6
1250

4 10 rpm

0
0 1 2 3 4 5 70 80 90 100
external leakage [l/min] volumetric efficiency [%]

0 50 100 150 200 250


pressure [bar] Reference viscosity: 40 cSt

Example:
We suppose (1250 cc): p=200 [bar], we obtain: external leakage 4,3 [l/min], shaft creep speed 4,2 [rpm].
If we suppose (1250 cc): p=200 [bar] and n=100 [rpm] we obtain a volumetric efficiency of 96%;

BEARING LIFE
Reference displacement 800 cc
n=25 n=50 n=100
n=200
ar
250 b ar
n=400 180 b
n=600 EX 2
ar
EX 1 120 b
r
60 ba

L50h 200000 100000 50000 20000 10000 5000 2000 1000


a=2
300000 30000 3000 00
mm a=150 mm
10 kN

Fr Sh
a=100 mm

Fr 20 kN af
ts
tre
ss
lim
Fr=radial load it
30 kN
a=distance of radial load from mounting face a=
50
n=shaft speed [rpm] mm
40 kN

a
Reference viscosity: 40 cSt

Example:
We suppose (EX1): p=180 [bar], n=100 [rpm]; we obtain an average lifetime of 25000 [h].
If we suppose (EX2): Fr=10 [kN], a=150 [mm], n=100 [rpm] and p=180 [bar] we obtain an average life-
time of 18000 [h].

68 R8D rev.00 - Oct. 2018


R8D H4 - ORDERING CODE

R8D -- -- H4 -- -- -- -- SB -

TACHOMETER

TA SPECIAL SPLINE
DISPLACEMENT INTERCHANGEABILITY SHAFT FEATURES BILLET
TB
500 /C A0 A01 MP SB4
SERIE
TT1
600 /B45 A1 A11 SPSL SB5
H4 TQ1
700 /GM4 A2 A21 HPS SB16
EST
800 /S A22 A3 CCW SB17
EST30
850 /SB506 A31 See pag. 23 SB21
EST31
900 SB23
Z--
EST32
1000 Italgroup SB30
EST33 internal code
1250
DISTRIBUTOR See pag. 177-180 See pag. 181-185
D31B D31BJ
D36B D36BJ
D310B D310BJ
D40 D40J
D47 D47J
D416 D416J
D75 D75J
D90 D90J
See pag. 174-175

EXAMPLES:

R8D 800 H4 A0 D40


R8D 800/C H4 A0 D47
R8D 1000/GM4 H4 A3 D47 CCW

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 69
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

70 R8D rev.00 - Oct. 2018


R8D H45
R8D H45 Pag. 72 - 73

R8D H45/C Pag. 74 - 75

R8D H45 - PERFORMANCE CURVES Pag. 76 - 78

R8D H45 - ORDERING CODE Pag. 119

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 71
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H45
40,5
35 246 DRAIN PORT
19 1/2" BSP

N°2 PORTS
1" BSP

0,05
301,6 -- 0,15

495
130

148

130
228
69

D40 (*)


41 32
7
16 N°5 MTG HOLES
20,5 ON A 327 P.C.D.
68
MTG FACE

DRAIN PORT
77 210 1/2" BSP

TECHNICAL DATA
1100 1400
DISPLACEMENT [cc] 1182 1376
SPECIFIC TORQUE [Nm/bar] 18.8 21.9
MAX. CONT. PRESSURE [bar] 270 270
HYDROSTATIC TEST PRES- [bar] 420 420
SURE
MAX. CONT. SPEED [rpm] 400 350
PEAK SPEED (***) [rpm] 450 400
MAX. CONT. POWER (****) [kW] 158 158
MAX. POWER [kW] 190 190
MAX. CASE PRESSURE [bar] 6 6
DRY WEIGHT [kg] 120 120
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70

- (*) The standard distributor (D40) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

72 R8D rev.00 - Oct. 2018


SHAFTS

A0 A3
MOUNTING FACE

MOUNTING FACE
92 54
M16

72
18

M8

∅80
35

N65x3x20-9H
62 UNI 222

DIN 5480
50
132

Available spline billet: SB6

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 73
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H45/C
246 DRAIN PORT
16 1/2" BSP

N°2 PORTS
1" BSP

495
- 0,05
250 - 0,15
130

360

130
39
69

D40 (*) 3
3 0

16
N°5 MTG HOLES
41 15 ON A 330 P.C.D.
MTG FACE

68
DRAIN PORT
77 226 1/2" BSP
Available distributor flange: FL4
Refer to page 186-187
(distributor fitting D75)

TECHNICAL DATA
1100 1400
DISPLACEMENT [cc] 1182 1376
SPECIFIC TORQUE [Nm/bar] 18.8 21.9
MAX. CONT. PRESSURE [bar] 270 270
HYDROSTATIC TEST PRES- [bar] 420 420
SURE
MAX. CONT. SPEED [rpm] 400 350
PEAK SPEED (***) [rpm] 450 400
MAX. CONT. POWER (****) [kW] 158 158
MAX. POWER [kW] 190 190
MAX. CASE PRESSURE [bar] 6 6
DRY WEIGHT [kg] 120 120
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70

- (*) The standard distributor (D40) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

74 R8D rev.00 - Oct. 2018


SHAFTS

A0 A3
MOUNTING FACE

MOUNTING FACE
92
M16

72
18 38

M8

∅80
35

N65x3x20-9H
62 UNI 222

DIN 5480
116 50

Available spline billet: SB6

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 75
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H45 - PERFORMANCE CURVES


R8D 1100 H45

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 1400 H45

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

76 R8D rev.00 - Oct. 2018


CREEP SPEED - VOLUMETRIC EFFICIENCY
50 100 300 450
6
1100
5 25 200

creep speed [rpm]


1400
4

3
10 rpm

0
0 1 2 3 4 5 80 85 90 95 100
external leakage [l/min] volumetric efficiency [%]

0 50 100 150 200 250


pressure [bar] Reference viscosity: 40 cSt

Example:
We suppose (1100 cc): p=200 [bar], we obtain: external leakage 4,3 [l/min], shaft creep speed 4,5 [rpm].
If we suppose (1100 cc): p=200 [bar] and n=100 [rpm] we obtain a volumetric efficiency of 95,5%;

BEARING LIFE
n=25 n=50 n=100 n=200
n=300
n=450 250 bar
n=600
180 bar
EX 2
120 bar
EX 1
60 bar

L50h 100000 50000 20000 10000 5000 2000 1000


a=2
30000 3000 10 kN 00
mm a=150 mm

Fr
20 kN
a=100 mm
Sh
Fr 30 kN af
ts
tre
ss
40 kN a= lim
Fr=radial load 50 it
mm
a=distance of radial load from mounting face 50 kN
n=shaft speed [rpm]
60 kN

a
Reference viscosity: 40 cSt

Example:
We suppose (EX2): p=180 [bar], n=200 [rpm]; we obtain an average lifetime of 22000 [h].
If we suppose (EX1): Fr=15 [kN], a=150 [mm], n=200 [rpm] and p=120 [bar] we obtain an average life-
time of 51000 [h].

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 77
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H45 - ORDERING CODE

R8D -- -- H45 -- -- -- -- SB -

TACHOMETER

TA SPECIAL SPLINE
DISPLACEMENT INTERCHANGEABILITY SHAFT FEATURES BILLET
TB
1100 /C A0 A3 MP SB6
SERIE
TT1
1400 SPSL See pag. 181-185
H45 TQ1
HPS
EST
CCW
EST30
See pag. 23
EST31
Z--
EST32
Italgroup
EST33 internal code
DISTRIBUTOR See pag. 177-180
D31B D31BJ
D36B D36BJ
D310B D310BJ
D40 D40J
D47 D47J
D416 D416J
D75 D75J
D90 D90J
See pag. 174-175

EXAMPLES:

R8D 1100 H45 A0 D75


R8D 1100/C H45 A0 D47
R8D 1400/C H45 A0 D75 SB6

78 R8D rev.00 - Oct. 2018


R8D H5
R8D H5 Pag. 80 - 82

R8D H5/C1100 Pag. 84 - 85

R8D 1600-1800-2000-2200/C H5 Pag. 86 - 87

R8D 1000/B60-1400/B80-1600/B100 H5 Pag. 88 - 89

R8D H5/GM5 - R8D H5/S Pag. 90 - 91

R8D H5/RM Pag. 92 - 93

R8D H5 - PERFORMANCE CURVES Pag. 94 - 98

R8D H5 - ORDERING CODE Pag. 99

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 79
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H5
40,5
264
35 DRAIN PORT
19 146 1/2" BSP

N°2 PORTS
1"1/2 SAE 3000

0,15
301,6 -- 0,05
30
170

148
228

545
83

32
D75 (*) 7

N°5 MTG HOLES


16 20,5 ON A 327 P.C.D.
55
MTG FACE

107 215 DRAIN PORT 92


1/2" BSP

Available distributor flanges: FL5 FL6


For S03 and S04, refer to page
186-187 (distributor fitting D75)

TECHNICAL DATA
900 1000 1200 1400 1500 1600 1800 2000
DISPLACEMENT [cc] 941 1094 1231 1376 1528 1648 1815 2034
SPECIFIC TORQUE [Nm/bar] 15 17.4 19.6 21.9 24.3 26.2 28.9 32.4
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 250 190
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 550 500 450 410 390 370 340 280
PEAK SPEED (***) [rpm] 600 550 510 470 450 425 390 310
MAX. CONT. POWER (****) [kW] 178 178 178 178 178 178 178 140
MAX. POWER [kW] 210 210 210 210 210 210 210 160
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6 6
DRY WEIGHT [kg] 173 173 173 173 173 173 173 173
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D75) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

80 R8D rev.00 - Oct. 2018


SHAFTS
MOUNTING FACE

MOUNTING FACE

1/2"-20 UNF 2B
A0 A1
MOUNTING FACE

MOUNTING FACE
88 72

1/2"-20 UNF 2B
M16

65 88 5572
M16

65 55

35 30
221- 8x62x72

PITCH 6/12 Z=14


UNI 8953 - 8x62x72

BSASA.B.5.15.1960
BS 3550 1963
35 30
DIN ISO 14 - 8x62x72
62 UNI 221

PITCH 6/12 Z=14


UNI 8953 - 8x62x72

ASA.B.5.15.1960
3550 1963
UNI 14

148 132
62ISO

148 132
DIN

Available spline billet: SB6 Available spline billet: SB7

A2 A21 A23
MOUNTING FACE

MOUNTING FACE
MOUNTING FACE

90 5 80 5
MOUNTING FACE

MOUNTING FACE

90 5
MOUNTING FACE

90 5 90 5 80 5
1/2"-20 UNF 2B

1/2"-20 UNF 2B
UNF 2B

UNF 2B
+0,013

+0.011
+0.012
∅60-0,008

∅70-0,007

+0.03
∅60+0,013

+0.011
∅70+0.012
-0,008

-0,007

70+0.03
1/2"-20

1/2"-20

18 18 18 2020
M12

18
∅∅70
M12
74.5
74.5
64

74
64

74

30 30 30 30 28
28

111 111 100100 101


101

171 171 135 135 235


235

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 81
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
82
35

35

10

10

18

18
R8D H5
MOUNTING FACE
MOUNTING FACE

8
53

53
MOUNTING FACE
MOUNTING FACE

35

35

55

55

50

50
M16
N65x3x20-9H N65x3x20-9H M16
DIN 5480 DIN 5480
A31

A33
M8
N65x3x20-9H N65x3x20-9H M8 ∅80 ∅80
DIN 5480 DIN 5480
∅80 ∅80
31

31

35

35

8
MOUNTING FACE
MOUNTING FACE
MOUNTING FACE
MOUNTING FACE
65
55

65
55

55

55
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

50
43
10

50
43
10

M12 M12
M16
A32

N60x3x18-9H N60x3x18-9H M16 45+0,02


∅ +0,01
∅45+0,02
+0,01
DIN 5480 DIN 5480 N55x3x17-9H N55x3x17-9H

A34
DIN 5480 DIN 5480
∅80 ∅80
∅80 ∅80

R8D rev.00 - Oct. 2018


SHAFTS

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 83
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H5/C1100
264
DRAIN PORT
16 1/2" BSP
146

N°2 PORTS
1"1/2 SAE 3000

30 - 0,05
250 - 0,15
170

360

545
83

33
0
D75 (*)

N°5 MTG HOLES


15 ON A 330 P.C.D.
MTG FACE

55
92
DRAIN PORT
107 231 1/2" BSP

Available distributor flange: FL4


Refer to page 186-187
(distributor fitting D75)

TECHNICAL DATA
900 1000 1200 1400 1500 1600 1800 2000
DISPLACEMENT [cc] 941 1094 1231 1376 1528 1648 1815 2034
SPECIFIC TORQUE [Nm/bar] 15 17.4 19.6 21.9 24.3 26.2 28.9 32.4
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 250 190
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 550 500 450 410 390 370 340 280
PEAK SPEED (***) [rpm] 600 550 510 470 450 425 390 310
MAX. CONT. POWER (****) [kW] 178 178 178 178 178 178 178 140
MAX. POWER [kW] 210 210 210 210 210 210 210 160
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6 6
DRY WEIGHT [kg] 173 173 173 173 173 173 173 173
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D75) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

84 R8D rev.00 - Oct. 2018


SHAFTS
MOUNTING FACE

MOUNTING FACE

MOUNTING FACE
A0 A01 A11

92 92 92
M16

M16

M16
72 72 72

35 35 35

W70x3x22-8e
DIN 5480
62 UNI 222

52 UNI 222

116 116 116

Available spline billet: SB6 Available spline billet: SB16

A2 A3
MOUNTING FACE
MOUNTING FACE

116
80 4
M12x25

∅70 k6

20 18 38
M8
76.5

∅80

8
N65x3x20-9H

88
DIN 5480

50

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 85
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D 1600-1800-2000/C H5
28,5 264
DRAIN PORT
14,5 1/2" BSP
146

N°2 PORTS
1"1/2 SAE 3000

31,5

0,05
290 -- 0,15
170

225

545
83

38
0
D75 (*)

N°5 MTG HOLES


17 ON A 380 P.C.D.
MTG FACE

55
DRAIN PORT 92
107 216,5
1/2" BSP

Available distributor flange: FL4


Refer to page 186-187
(distributor fitting D75)

TECHNICAL DATA
1600 1800 2000
DISPLACEMENT [cc] 1648 1815 2034
SPECIFIC TORQUE [Nm/bar] 26.2 28.9 32.4
MAX. CONT. PRESSURE [bar] 270 250 190
HYDROSTATIC TEST PRES- [bar] 420 420 420
SURE
MAX. CONT. SPEED [rpm] 370 340 280
PEAK SPEED (***) [rpm] 425 390 310
MAX. CONT. POWER (****) [kW] 178 178 140
MAX. POWER [kW] 210 210 160
MAX. CASE PRESSURE [bar] 6 6 6
DRY WEIGHT [kg] 173 173 173
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D75) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

86 R8D rev.00 - Oct. 2018


SHAFTS

A0 A1
MOUNTING FACE

MOUNTING FACE
72 UNI 222

100 100
M16

M12
80 80

35 30

W80x3x25-8e
133

DIN 5480
Available spline billet: SB8
133

A2 A3
MOUNTING FACE
MOUNTING FACE

90 5
+0.011
∅80+0.03

22 47
M16
85

∅95

35 8
N75x3x24-9H
DIN 5480

57

133

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 87
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D 1000/B60-1400/B80-1600/B100
40,5
264
35 DRAIN PORT
19 146 1/2" BSP

N°2 PORTS
1"1/2 SAE 3000

0,15
301,6 -- 0,05
30
170

148
228

545
83

32
D75 (*) 7

N°5 MTG HOLES


16 20,5 ON A 327 P.C.D.
55
MTG FACE

107 215 DRAIN PORT 92


1/2" BSP

Available distributor flanges: FL5 FL6


For S03 and S04, refer to page
186-187 (distributor fitting D75)

TECHNICAL DATA
1000 1400 1600
DISPLACEMENT [cc] 1094 1376 1648
SPECIFIC TORQUE [Nm/bar] 17.4 21.9 26.2
MAX. CONT. PRESSURE [bar] 270 270 270
HYDROSTATIC TEST PRES- [bar] 420 420 420
SURE
MAX. CONT. SPEED [rpm] 500 410 370
PEAK SPEED (***) [rpm] 550 470 425
MAX. CONT. POWER (****) [kW] 178 178 178
MAX. POWER [kW] 210 210 210
MAX. CASE PRESSURE [bar] 6 6 6
DRY WEIGHT [kg] 173 173 173
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D75) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

88 R8D rev.00 - Oct. 2018


SHAFTS
MOUNTING FACE

MOUNTING FACE

1/2"-20 UNF 2B
A0 A1
MOUNTING FACE

MOUNTING FACE
88 72

1/2"-20 UNF 2B
M16

65 88 5572
M16

65 55

35 30
221- 8x62x72

PITCH 6/12 Z=14


UNI 8953 - 8x62x72

BSASA.B.5.15.1960
BS 3550 1963
35 30
DIN ISO 14 - 8x62x72
62 UNI 221

PITCH 6/12 Z=14


UNI 8953 - 8x62x72

ASA.B.5.15.1960
3550 1963
UNI 14

148 132
62ISO

148 132
DIN

Available spline billet: SB6 Available spline billet: SB7

A2 A21 A23
MOUNTING FACE

MOUNTING FACE
MOUNTING FACE

90 5 80 5
MOUNTING FACE

MOUNTING FACE

90 5
MOUNTING FACE

90 5 90 5 80 5
1/2"-20 UNF 2B

1/2"-20 UNF 2B
UNF 2B

UNF 2B
+0,013

+0.011
+0.012
∅60-0,008

∅70-0,007

+0.03
∅60+0,013

+0.011
∅70+0.012
-0,008

-0,007

70+0.03
1/2"-20

1/2"-20

18 18 18 2020
M12

18
∅∅70
M12
74.5
74.5
64

74
64

74

30 30 30 30 28
28

111 111 100100 101


101

171 171 135 135 235


235

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 89
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H5/GM5 - R8D H5/S


264
DRAIN PORT
146 1/2" BSP
8 N°5 MTG SLOTS 19 mm
WIDE FROM 310 TO 330
N°2 PORTS
1"1/2 SAE 3000

- 0,05
265 - 0,15
170

310

330

372

545
83

D75 (*)

6
55
DRAIN PORT
MTG FACE

42 1/2" BSP
92
107 257

TECHNICAL DATA
900 1000 1200 1400 1500 1600 1800 2000
DISPLACEMENT [cc] 941 1094 1231 1376 1528 1648 1815 2034
SPECIFIC TORQUE [Nm/bar] 15 17.4 19.6 21.9 24.3 26.2 28.9 32.4
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 250 190
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 550 500 450 410 390 370 340 280
PEAK SPEED (***) [rpm] 600 550 510 470 450 425 390 310
MAX. CONT. POWER (****) [kW] 178 178 178 178 178 178 178 140
MAX. POWER [kW] 210 210 210 210 210 210 210 160
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6 6
DRY WEIGHT [kg] 173 173 173 173 173 173 173 173
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D75) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

90 R8D rev.00 - Oct. 2018


SHAFTS

A0 A1 A2
DIN ISO 14 - 8x56x65
UNI 8953 - 8x56x65
MOUNTING FACE

MOUNTING FACE

MOUNTING FACE
W65x3x20-8e
132
56 UNI 221

DIN 5480
110 6
M20

M20
90 90

+0.011
∅70+0.03
61 61 20

M30
74.5
40 40 55
90 90
134
Available spline billet: SB17 Available spline billet: SB23

MOUNTING FACE

A3 A31 A4
MOUNTING FACE

MOUNTING FACE

90
70 5

18 18 20
14 14 10+0,5
M8

M8

-0,5
40.5

28.5
∅73
∅75

∅75

55
DIN 5482

M30

10 10
N55x3x17-9H

55x50
DIN 5480

53 53 TAPER 1:10

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 91
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H5/RM
N°5 MTG HOLES 21 264
50 ON A  300 P.C.D. DRAIN PORT
146 1/2" BSP
9

31
N°2 PORTS
1"1/2 SAE 3000

230-0,05
-0,15
170

545
83

380
300
Ø32
7
D75 (*)

8
55 N°5 MTG HOLES
20,5 ON A 327 P.C.D.
MTG FACE

107 265 DRAIN PORT 92


1/2" BSP

TECHNICAL DATA
900 1000 1200 1400 1500 1600 1800 2000
DISPLACEMENT [cc] 941 1094 1231 1376 1528 1648 1815 2034
SPECIFIC TORQUE [Nm/bar] 15 17.4 19.6 21.9 24.3 26.2 28.9 32.4
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 250 190
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 550 500 450 410 390 370 340 280
PEAK SPEED (***) [rpm] 600 550 510 470 450 425 390 310
MAX. CONT. POWER (****) [kW] 178 178 178 178 178 178 178 140
MAX. POWER [kW] 210 210 210 210 210 210 210 160
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6 6
DRY WEIGHT [kg] 173 173 173 173 173 173 173 173
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D75) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

92 R8D rev.00 - Oct. 2018


SHAFTS

A1 A23
MOUNTING FACE

MOUNTING FACE
138 80 5

+0.011
101

M12

∅70+0.03
95
20
M20

DETAIL X
∅67 h12

74.5

X
35 28
2.65 H13
W70x3x22-8e
DIN 5480

71
101

185

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 93
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H5 - PERFORMANCE CURVES


R8D 1000 H5

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 1200 H5

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

94 R8D rev.00 - Oct. 2018


R8D 1400 H5

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 1500 H5

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 95
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H5 - PERFORMANCE CURVES


R8D 1600 H5

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 1800 H5

350 bar

300 bar

250 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

96 R8D rev.00 - Oct. 2018


R8D 2000 H5

270 bar

230 bar
190 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 97
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H5 - PERFORMANCE CURVES


CREEP SPEED - VOLUMETRIC EFFICIENCY

900 1000 50 100 300


6
1200
5 25 200 600

creep speed [rpm]


1400 1500
4
1600 1800

2000 3
10 rpm

0
0 1 2 3 4 5 80 85 90 95 100
external leakage [l/min] volumetric efficiency [%]

0 50 100 150 200 250


pressure [bar] Reference viscosity: 40 cSt

Example:
We suppose (1600 cc): p=200 [bar], we obtain: external leakage 4,3 [l/min], shaft creep speed 3,2 [rpm].
If we suppose (1600 cc): p=200 [bar] and n=100 [rpm] we obtain a volumetric efficiency of 97%;

BEARING LIFE
Reference displacement 1600 cc
n=25 n=50 n=100 n=200
n=300
250 bar
n=450
n=600 180 bar
EX 2 120 bar

60 bar
EX 1

L50h 100000 50000 20000 10000 5000 2000 1000


a=2
30000 3000 10 kN 00
mm a=150 mm

Fr
20 kN
a=100 mm
Sh
Fr 30 kN af
ts
tre
ss
40 kN a= lim
Fr=radial load 50 it
mm
a=distance of radial load from mounting face 50 kN
n=shaft speed [rpm]
60 kN

a
Reference viscosity: 40 cSt

Example:
We suppose (EX1): p=120 [bar], n=300 [rpm]; we obtain an average lifetime of 33000 [h].
If we suppose (EX2): Fr=15 [kN], a=150 [mm], n=200 [rpm] and p=180 [bar] we obtain an average life-
time of 11000 [h].

98 R8D rev.00 - Oct. 2018


R8D H5 - ORDERING CODE

R8D -- -- H5 -- -- -- -- SB -

TACHOMETER

TA SPECIAL SPLINE
DISPLACEMENT INTERCHANGEABILITY SHAFT FEATURES BILLET
TB
900 /C1100 A0 A01 MP SB6
SERIE
TT1
1000 /C A1 A11 SPSL SB7
H5 TQ1
1200 /B60 A2 A21 HPS SB8
EST
1400 /B80 A23 A3 CCW SB16
EST30
1500 /B100 A31 A32 See pag. 23 SB17
EST31
1600 /GM5 A33 A34 SB23
Z--
EST32
1800 /RM A4 Italgroup See pag. 181-185
EST33 internal code
2000
See pag. 177-180
DISTRIBUTOR

D31B D31BJ
D36B D36BJ
D310B D310BJ
D40 D40J
D47 D47J
D416 D416J
D75 D75J
D90 D90J
See pag. 174-175

EXAMPLES:

R8D 1000 H5 A1 D75 SB7


R8D 1400/C1100 H5 A0 D75
R8D 2000 H5 A0 D90 CCW SB6

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 99
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

100 R8D rev.00 - Oct. 2018


R8D H55
R8D H55 Pag. 102 - 103

R8D H55/MR1800 D75 Pag. 104 - 105

R8D H55/MR1800 D90 Pag. 106 - 107

R8D H55 - PERFORMANCE CURVES Pag. 108 - 112

R8D H55 - ORDERING CODE Pag. 113

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 101
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H55
34
285 DRAIN PORT
24 3/4" BSP

N°2 PORTS
1"1/2 SAE 6000

- 0,05
381 - 0,15
190

248

148
30
100

574
D90 (*)


41
59 9,
1
23 N°5 MTG HOLES 20,5
ON A 419,1 P.C.D.
95
MTG FACE

DRAIN PORT
3/4" BSP
113 256

Available distributor flange: FL7


Refer to page 186-187
(distributor fitting D75)

TECHNICAL DATA
1800 2150 2300 2400
DISPLACEMENT [cc] 1800 2126 2293 2393
SPECIFIC TORQUE [Nm/bar] 28.7 33.8 36.5 38.1
MAX. CONT. PRESSURE [bar] 270 270 250 250
HYDROSTATIC TEST PRES- [bar] 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 265 235 210 190
PEAK SPEED (***) [rpm] 290 260 235 220
MAX. CONT. POWER (****) [kW] 190 190 180 170
MAX. POWER [kW] 220 220 210 210
MAX. CASE PRESSURE [bar] 6 6 6 6
DRY WEIGHT [kg] 203 203 203 203
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D90) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

102 R8D rev.00 - Oct. 2018


SHAFTS

A0 A1 A11
DIN ISO 14 - 10x82x92
UNI 8953 - 10x82x92
MOUNTING FACE

MOUNTING FACE

PITCH 6/12 Z=20

MOUNTING FACE
ASA.B.5.15.1960
82 UNI 221

BS 3550 1963
3/4"-16 UNF 2B

W85x3x27-7h
3/4"-16 UNF 2B

DIN 5480
99
M20

120 99
76
97 76

35
35 35
153 142
142

Available spline billet: SB9 Available spline billet: SB10

A2 A4
MOUNTING FACE
MOUNTING FACE

1"1/2-12 UNF 2A
22.22 +0,0 05
3/4"-16 UNF 2B

4 133

130
9.5

24
91

∅95.5
∅85.3

35
TAPER 1:10
∅85+0.011

138
-0,009

74+0,6
-0,7
177
185.7 61
246.7

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 103
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H55/MR1800 D75


28 5
33,7 DRAIN PORT
1/2" BSP
16,7

N°2 PORTS
1"1/2 SAE 6000

8
 14
30

290-0,05
-0,15
190

248
83

574
D75 (*)

Ø
MTG FACE

55 N°5 MTG HOLES 17 38


0
ON A 380 P.C.D.
107 256 DRAIN PORT
1/2" BSP 92

Available distributor flange: FL4


For S04, refer to page 186-187
(distributor fitting D75)

TECHNICAL DATA
1800 2100 2200
DISPLACEMENT [cc] 1800 2035 2193
SPECIFIC TORQUE [Nm/bar] 28.7 32.4 34.9
MAX. CONT. PRESSURE [bar] 270 270 270
HYDROSTATIC TEST PRES- [bar] 420 420 420
SURE
MAX. CONT. SPEED [rpm] 265 235 220
PEAK SPEED (***) [rpm] 290 260 240
MAX. CONT. POWER (****) [kW] 190 190 190
MAX. POWER [kW] 220 220 220
MAX. CASE PRESSURE [bar] 6 6 6
DRY WEIGHT [kg] 203 203 203
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D75) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

104 R8D rev.00 - Oct. 2018


35 30

W80x3x25-8e
133

DIN 5480
133
SHAFTS

FACEFACE
A0 DIN ISO 14 - 10x82x92 A3
UNI 8953 - 10x82x92
MOUNTING FACE

MOUNTING FACE

MOUNTING
82 UNI 221

MOUNTING
90 5 5
+0.011
∅80+0.03
110

M20
M20

120 47
22
M16

97 25
85

95

∅95
35
35

∅90+0.01
-0,01
120
153 35 8

N75x3x24-9H
153

DIN 5480
57
Available spline billet: SB9

133

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 105
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H55/MR1800 D90

TECHNICAL DATA
2000 2200 2400
DISPLACEMENT [cc] 1962 2193 2393
SPECIFIC TORQUE [Nm/bar] 31.2 34.9 38.1
MAX. CONT. PRESSURE [bar] 270 270 250
HYDROSTATIC TEST PRES- [bar] 420 420 420
SURE
MAX. CONT. SPEED [rpm] 245 220 190
PEAK SPEED (***) [rpm] 270 240 220
MAX. CONT. POWER (****) [kW] 190 190 170
MAX. POWER [kW] 220 220 210
MAX. CASE PRESSURE [bar] 6 6 6
DRY WEIGHT [kg] 203 203 203
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D90) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

106 R8D rev.00 - Oct. 2018


35 30

W80x3x25-8e
133

DIN 5480
133
SHAFTS

FACEFACE
A0 DIN ISO 14 - 10x82x92 A3
UNI 8953 - 10x82x92
MOUNTING FACE

MOUNTING FACE

MOUNTING
82 UNI 221

MOUNTING
90 5 5
+0.011
∅80+0.03
110

M20
M20

120 47
22
M16

97 25
85

95

∅95
35
35

∅90+0.01
-0,01
120
153 35 8

N75x3x24-9H
153

DIN 5480
57
Available spline billet: SB9

133

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 107
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H55 - PERFORMANCE CURVES


R8D 1800 H55

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 2000 H55

350 bar
300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

108 R8D rev.00 - Oct. 2018


R8D 2100 H55

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 2150 H55

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 109
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H55 - PERFORMANCE CURVES


R8D 2200 H55

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 2300 H55

350 bar

300 bar

250 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

110 R8D rev.00 - Oct. 2018


R8D 2400 H55

330 bar

290 bar
250 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 111
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H55 - PERFORMANCE CURVES


CREEP SPEED - VOLUMETRIC EFFICIENCY

2000 2200 25 50 100 200


3
1800 2100
2,5

creep speed [rpm]


2400 cc 10 rpm
2300 2

1,5

0,5

0
0 1 2 3 4 5 80 85 90 95 100
external leakage [l/min] volumetric efficiency [%]

0 50 100 150 200 250


pressure [bar] Reference viscosity: 40 cSt

Example:
We suppose (2200 cc): p=150 [bar], we obtain: external leakage 3,2 [l/min], shaft creep speed 1,9 [rpm].
If we suppose (2200 cc): p=150 [bar] and n=50 [rpm] we obtain a volumetric efficiency of 96%;

BEARING LIFE
Reference displacement 2300 cc
n=25 n=50 n=100 n=175

n=300
250 bar

EX 2 180 bar

EX 1 120 bar
60 bar

L50h 100000 50000 20000 10000 5000 2000 1000


30000 3000 a =2
00
mm
20 kN
Fr a=

Fr
150
m
a= m Sh
af
100
Fr=radial load 40 kN mm t st
re
ss
a=distance of radial load from mounting face a=
lim
50 it
n=shaft speed [rpm] 60 kN mm

a 80 kN
Reference viscosity: 40 cSt

Example:
We suppose (EX1): p=180 [bar], n=100 [rpm]; we obtain an average lifetime of 33000 [h].
If we suppose (EX2): Fr=20 [kN], a=100 [mm], n=100 [rpm] and p=250 [bar] we obtain an average life-
time of 11000 [h].

112 R8D rev.00 - Oct. 2018


R8D H55 - ORDERING CODE

R8D -- -- H55 -- -- -- -- SB -

TACHOMETER

TA SPECIAL SPLINE
DISPLACEMENT INTERCHANGEABILITY SHAFT FEATURES BILLET
TB
1800 /MR1800 A0 A1 MP SB9
SERIE
TT1
2000 A11 A2 SPSL SB10
H55 TQ1
2100 A3 A4 HPS See pag. 181-185
EST
2150 CCW
EST30
2200 See pag. 23
EST31
2300
Z--
EST32
2400 Italgroup
EST33 internal code
DISTRIBUTOR See pag. 177-180
D31B D31BJ
D36B D36BJ
D310B D310BJ
D40 D40J
D47 D47J
D416 D416J
D75 D75J
D90 D90J
See pag. 174-175

EXAMPLES:

R8D 2150 H55 A1 D90 SB10


R8D 2400/MR1800 H55 A0 D90
R8D 2100/MR1800 H55 A3 D75

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 113
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

114 R8D rev.00 - Oct. 2018


R8D H6
R8D H6 Pag. 116 - 119

R8D H6/C Pag. 120 - 121

R8D 2200/B125-2500/B150-3000/B200 H6 Pag. 122 - 123

R8D/GM6 H6 Pag. 124 - 125

R8D/PL H6 Pag. 126 - 127

R8D H6 - PERFORMANCE CURVES Pag. 128 - 132

R8D H6 - ORDERING CODE Pag. 133

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 115
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H6
34
DRAIN PORT
24 329 3/4" BSP

N°2 PORTS
1"1/2 SAE 6000

35

381-0,05
-0,15
248
190

667
100

D90 (*) 178

Ø
23 N°5 MTG HOLES

41
20,5 ON A 419,1 P.C.D.

9,
1
59
MTG FACE

DRAIN PORT
3/4" BSP 95
113 266

Available distributor flange: FL7


For S04, refer to page 186-187
(distributor fitting D90)

TECHNICAL DATA
1800 2000 2200 2500 2800 3000 3200 3500
DISPLACEMENT [cc] 1866 1993 2206 2525 2807 2983 3289 3479
SPECIFIC TORQUE [Nm/bar] 29.7 31.7 35.1 40.2 44.7 47.5 52.4 55.4
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 270 270
HYDROSTATIC TEST PRESSURE [bar] 420 420 420 420 420 420 420 420
MAX. CONT. SPEED [rpm] 350 350 325 285 250 235 210 200
PEAK SPEED (***) [rpm] 400 400 375 325 290 270 240 230
MAX. CONT. POWER (****) [kW] 220 220 220 220 220 220 220 210
MAX. POWER [kW] 245 245 245 245 245 245 245 235
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6 6
DRY WEIGHT [kg] 308 308 308 308 308 308 308 308
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D90) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

116 R8D rev.00 - Oct. 2018


MOUNTING FACE

MOUNTING FACE MOUNTING FACE


MOUNTING FACE
MOUNTING FACE

97

133 133
MOUNTING FACE

35
97
MOUNTING FACE

76 76
A12

133
35
3/4"-16 UNF 2B

97
A0

153 153

76
MOUNTING FACE
BS 3550

35
97 97
3/4"-16 UNF1963
2B

133
ASA.B.5.15.1960 M20

3515335

97
120
BS 3550 1963

120 120 97

76
3/4"-16
PITCH UNF
5/10 2B
Z=16

Available spline billet:


Available spline billet:
ASA.B.5.15.1960 82 UNI 221

35
35
BS 3550 1963 M20

153
PITCH 5/10 Z=16 UNI 8953 - 10x82x92

120
ASA.B.5.15.1960 UNI 221

SB9
97
M20

SB27
3/4"-16 UNF 2B DIN ISO
8214 - 10x82x92
PITCH 5/10 Z=16 UNI 8953 - 10x82x92

35
BS 3550 1963 82 UNI 221
DIN ISO 14 - 10x82x92
ASA.B.5.15.1960 UNI 8953 - 10x82x92
M20
PITCH 5/10 Z=16 MOUNTING - 10x82x92
DIN ISO 14FACE
91 82 UNI 221

24
UNI 8953 - 10x82x92
MOUNTING FACE
91
DIN ISO 14 - 10x82x92

24
91 MOUNTING FACE
MOUNTING FACE

24
133 133
35
MOUNTING FACE MOUNTING FACE
91
76 76

24
133
35
MOUNTING FACE 3/4"-16 UNF 2B
97
97 97 76

131
BS 3550
35

3/4"-16 UNF1963
2B

167 167
133
MOUNTING FACE ASA.B.5.15.1960

131
120 120
97
A1

BS 3550 1963
76

3/4"-16
PITCH UNF
6/12 2B
Z=20

167
A2
ASA.B.5.15.1960
35

35 131
120

35
3/4"-16 UNF 2B BS 3550 1963

5
PITCH 6/12 Z=20
∅85+0.011 ASA.B.5.15.1960

35

right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
-0,009 3/4"-16 UNF 2B

167
3/4"-16 UNF 2B PITCH 6/12 Z=20

131
120
BS 3550 1963
Available spline billet:

∅85+0.011
-0,009

5
3/4"-16 UNF 2B ASA.B.5.15.1960

35
∅85+0.011
-0,009 PITCH 6/12 Z=20
SB10

3/4"-16 UNF 2B

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
∅85+0.011
-0,009
SHAFTS

117
118
100
100

25
25

35
35

8
8
MOUNTING FACE
MOUNTING FACE 100 MOUNTING FACE
MOUNTING FACE
R8D H6

25

62
48

35

62
48

8
185
A21

185
MOUNTING FACE

120
100
M20
MOUNTING FACE

10
100
N85x3x27-9H M20

10

12035
N85x3x27-9H

A3
DIN 5480

62
35

48
DIN 5480
∅105 3/4"-16 UNF 2B

185
∅105 3/4"-16 UNF 2B

120
100
M20 ∅95+0.011
-0,009
N85x3x27-9H ∅95+0.011
-0,009 10

35
DIN 5480 86,5

22.2
86,5 22.2
∅105 3/4"-16 UNF 2B
MOUNTING FACE ∅95+0.011
-0,009
MOUNTING FACE
MOUNTING FACE
86,5 MOUNTING FACE
22.2

-0,35
61+0,75
-0,35
61+0,75
MOUNTING FACE

172
35
∅85.3

130
MOUNTING FACE
210
∅85.3

233
130

TAPER
170
130

210

233
9.5
170

-0,35
TAPER 1:10
1305

17261+0,75
9.5 MOUNTING FACE

10 1:10
5

35
35
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

68
22

172
58

61
∅85.3 22

61
130
M20
210

233
A23

170
130

1"1/2-12
9.5 UNF 2A ∅80+0.01 M20
1"1/2-12
M20 UNF 2A -0,01

TAPER 1:10
5

∅80+0.01
-0,01

A32
N80x3x25-9H∅95.5
35

DIN 5480
∅95.5
22

61
∅105 M20
1"1/2-12 UNF 2A ∅80+0.01
-0,01
∅95.5

R8D rev.00 - Oct. 2018


86,
35
5
∅95+0.011

∅80+0.01
170
-0,009

-0,01
210

SHAFTS

A4
MOUNTING FACE

1"1/2-12 UNF 2A
130
22
9.5

∅95.5
∅85.3
∅105

TAPER 1:10
61+0,75
DIN 5480

-0,35

172 61
233

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 119
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H6/C
34 DRAIN PORT
329 3/4" BSP
23

N°2 PORTS
1"1/2 SAE 6000

35

335-0,05
-0,15

667
190

248
100

D90 (*) 178

N°5 MTG HOLES Ø


19 ON A 440 P.C.D. 44
59 0
MTG FACE

DRAIN PORT
3/4" BSP 95
113 266

Available distributor flange: FL10


For S04, refer to page 186-187
(distributor fitting D75)

TECHNICAL DATA
1800 2000 2200 2500 2800 3000 3200 3500
DISPLACEMENT [cc] 1866 1993 2206 2525 2807 2983 3289 3479
SPECIFIC TORQUE [Nm/bar] 29.7 31.7 35.1 40.2 44.7 47.5 52.4 55.4
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 270 270
HYDROSTATIC TEST PRESSURE [bar] 420 420 420 420 420 420 420 420
MAX. CONT. SPEED [rpm] 350 350 325 285 250 235 210 200
PEAK SPEED (***) [rpm] 400 400 375 325 290 270 240 230
MAX. CONT. POWER (****) [kW] 220 220 220 220 220 220 220 210
MAX. POWER [kW] 245 245 245 245 245 245 245 235
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6 6
DRY WEIGHT [kg] 308 308 308 308 308 308 308 308
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D90) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

120 R8D rev.00 - Oct. 2018


95

24
95 MOUNTING
MOUNTING
FACEFACE

25
95
MOUNTING FACE

25
95
MOUNTING FACE

25
MOUNTING FACE

153
MOUNTING FACE

153 153
97
MOUNTING FACE

120 120
A0

97 97

35
153
MOUNTING FACE

120 120

35 35

153
97
M20 M20

120
110
35

5
Available spline billet:

120
A2
82M20
UNI 222

35
82 UNI 222

153
5
M20

153 120
110
B10x82x92
82 UNI 222DIN 5463

35
5
SB9

120
110 110
M20 DIN 5463

153 35
B10x82x92 82 UNI 222

5
∅90+0.01
-0,01 M20 B10x82x92 DIN 5463

35
∅90+0.01
-0,01 M20
∅90+0.01
-0,01 M20
∅90+0.01
-0,01

MOUNTING FACE

35

8
MOUNTING
MOUNTING FACE
FACE

8
8
MOUNTING FACE MOUNTING FACE

8
MOUNTING FACE
133
MOUNTING FACE

62
97

48
76

133
153

62
MOUNTING FACE

48

62
97

48
35
120
76

133
A1

100

62
97

35

48
76

35

N85x3x27-9H M20
35

N85x3x27-9H
DIN 5480
N85x3x27-9H 3/4"-16 UNF 2B
M20
DINDIN 5480
5480

A3
N85x3x27-9H ∅105 UNF
3/4"-16 BS 3550
2B 1963
W90x4x21-8e

right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
DIN 5480 ∅105
∅105 BS 3/4"-16 UNF 2B
ASA.B.5.15.1960
3550 1963
DIN 5480
∅105 PITCH
ASA.B.5.15.1960
BS 3550 Z=20
6/12 1963
6/12 Z=20
PITCHASA.B.5.15.1960
PITCH 6/12 Z=20

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
SHAFTS

121
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D 2200/B125-2500/B150-3000/B200 H6
34
DRAIN PORT
24 329 3/4" BSP

N°2 PORTS
1"1/2 SAE 6000

35

381-0,05
-0,15
248
190

667
100

D90 (*) 178

Ø
23 N°5 MTG HOLES

41
20,5 ON A 419,1 P.C.D.

9,
1
59
MTG FACE

DRAIN PORT
3/4" BSP 95
113 266

Available distributor flange: FL7


For S04, refer to page 186-187
(distributor fitting D90)

TECHNICAL DATA
2200 2500 3000
DISPLACEMENT [cc] 2206 2525 2983
SPECIFIC TORQUE [Nm/bar] 35.1 40.2 47.5
MAX. CONT. PRESSURE [bar] 270 270 270
HYDROSTATIC TEST PRESSURE [bar] 420 420 420
MAX. CONT. SPEED [rpm] 325 285 235
PEAK SPEED (***) [rpm] 375 325 270
MAX. CONT. POWER (****) [kW] 220 220 220
MAX. POWER [kW] 245 245 245
MAX. CASE PRESSURE [bar] 6 6 6
DRY WEIGHT [kg] 308 308 308
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D90) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

122 R8D rev.00 - Oct. 2018


BS 3550 1963
ASA.B.5.15.1960 MOUNTING FACE
M20
PITCH 5/10 Z=16

133
82 UNI 221

97
76
UNI 8953 - 10x82x92

35
DIN ISO 14 - 10x82x92

153
120
97
3/4"-16 UNF 2B

35
BS 3550 1963
91 MOUNTING FACE
ASA.B.5.15.1960

24
M20
PITCH 5/10 Z=16
82 UNI 221
UNI 8953 - 10x82x92

133
MOUNTING FACE DIN ISO 14 - 10x82x92

97
A1

76

35
3/4"-16
MOUNTING 2B
UNFFACE

167
Available spline billet:
91

131
120

24
BS 3550 1963

5
ASA.B.5.15.1960

35
SB10
PITCH 6/12 Z=20

133
MOUNTING
97
3/4"-16 UNF 2BFACE

76
85+0.011

35
-0,009

3/4"-16 UNF 2B

167
A2

131
120
BS 3550 1963

5
ASA.B.5.15.1960

35
PITCH 6/12
MOUNTING Z=20
FACE
3/4"-16 UNF 2B
∅ 85+0.011
-0,009
133
97
76
A12

35
153

3/4"-16 UNF 2B
Available spline billet:
35

right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
BS 3550 1963
ASA.B.5.15.1960
SB27

PITCH 5/10 Z=16

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
SHAFTS

91

123
24
133
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H6/GM6
38
N°5 MTG HOLES 21 DRAIN PORT
17,5 329 3/4" BSP
ON A 419,1 P.C.D.

N°2 PORTS
1"1/2 SAE 6000

35 381-0,05
-0,15

419,1
460
190

667
100

178
D90 (*)

15

Ø
41
9,
59

1
MTG FACE

DRAIN PORT
3/4" BSP 95
113 304

Available distributor flange: FL7


For S04, refer to page 186-187
(distributor fitting D90)

TECHNICAL DATA
1800 2000 2200 2500 2800 3000 3200 3500
DISPLACEMENT [cc] 1866 1993 2206 2525 2807 2983 3289 3479
SPECIFIC TORQUE [Nm/bar] 29.7 31.7 35.1 40.2 44.7 47.5 52.4 55.4
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 270 270
HYDROSTATIC TEST PRESSURE [bar] 420 420 420 420 420 420 420 420
MAX. CONT. SPEED [rpm] 350 350 325 285 250 235 210 200
PEAK SPEED (***) [rpm] 400 400 375 325 290 270 240 230
MAX. CONT. POWER (****) [kW] 220 220 220 220 220 220 220 210
MAX. POWER [kW] 245 245 245 245 245 245 245 235
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6 6
DRY WEIGHT [kg] 308 308 308 308 308 308 308 308
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D90) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

124 R8D rev.00 - Oct. 2018


SHAFTS

A32
MOUNTING FACE

20
M20

35
∅105

10
N80x3x25-9H
DIN 5480

68

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 125
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H6/PL
DRAIN PORT
23 329 3/4" BSP

N°2 PORTS
1"1/2 SAE 6000

35

355-0,05
-0,15
190

667
100

178
D90 (*)

N°5 MTG HOLES

Ø
22 ON A 425 P.C.D.

42
59
MTG FACE

5
DRAIN PORT
3/4" BSP 95
113 266

TECHNICAL DATA
1800 2000 2200 2500 2800 3000 3200 3500
DISPLACEMENT [cc] 1866 1993 2206 2525 2807 2983 3289 3479
SPECIFIC TORQUE [Nm/bar] 29.7 31.7 35.1 40.2 44.7 47.5 52.4 55.4
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 270 270
HYDROSTATIC TEST PRESSURE [bar] 420 420 420 420 420 420 420 420
MAX. CONT. SPEED [rpm] 350 350 325 285 250 235 210 200
PEAK SPEED (***) [rpm] 400 400 375 325 290 270 240 230
MAX. CONT. POWER (****) [kW] 220 220 220 220 220 220 220 210
MAX. POWER [kW] 245 245 245 245 245 245 245 235
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6 6
DRY WEIGHT [kg] 308 308 308 308 308 308 308 308
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D90) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

126 R8D rev.00 - Oct. 2018


SHAFTS

A13
MOUNTING FACE

M24
155
120

50
W100x5x18-8f
DIN 5480

178

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 127
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H6 - PERFORMANCE CURVES


R8D 1800 H6

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 2000 H6

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

128 R8D rev.00 - Oct. 2018


R8D 2200 H6

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 2500 H6

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 129
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H6 - PERFORMANCE CURVES


R8D 2800 H6

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 3000 H6

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

130 R8D rev.00 - Oct. 2018


R8D 3200 H6

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 3500 H6

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 131
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H6 - PERFORMANCE CURVES


CREEP SPEED - VOLUMETRIC EFFICIENCY

2000 2200 25 50 100 200


3
1800 2500
2800 2,5

creep speed [rpm]


3000
3200 2 10 rpm

3500 cc 1,5

0,5

0
0 1 2 3 4 5 80 85 90 95 100
external leakage [l/min] volumetric efficiency [%]

0 50 100 150 200 250


pressure [bar] Reference viscosity: 40 cSt

Example:
We suppose (2800 cc): p=200 [bar], we obtain: external leakage 4,3 [l/min], shaft creep speed 1,9 [rpm].
If we suppose (2800 cc): p=200 [bar] and n=50 [rpm] we obtain a volumetric efficiency of 96%;

BEARING LIFE
Reference displacement 3000 cc
n=25 n=50 n=100

n=175
250 bar
n=300
n=450 EX 2 180 bar

120 bar
EX 1

60 bar

L50h 100000 50000 20000 10000 5000 2000 1000


30000 3000 a =2
00
mm
20 kN
Fr a=

Fr
150
m
a= m Sh
af
100
Fr=radial load 40 kN mm t st
re
ss
a=distance of radial load from mounting face a=
lim
50 it
n=shaft speed [rpm] 60 kN mm

a 80 kN
Reference viscosity: 40 cSt

Example:
We suppose (EX1): p=120 [bar], n=300 [rpm]; we obtain an average lifetime of 34000 [h].
If we suppose (EX2): Fr=20 [kN], a=100 [mm], n=50 [rpm] and p=250 [bar] we obtain an average lifetime
of 13000 [h].

132 R8D rev.00 - Oct. 2018


R8D H6 - ORDERING CODE

R8D -- -- H6 -- -- -- -- SB -

TACHOMETER

TA SPECIAL SPLINE
DISPLACEMENT INTERCHANGEABILITY SHAFT FEATURES BILLET
TB
1800 /C A0 A1 MP SB9
SERIE
TT1
2000 /B125 A12 A13 SPSL SB10
H6 TQ1
2200 /B150 A2 A21 HPS SB27
EST
2500 /B200 A23 A3 CCW See pag. 181-185
EST30
2800 /GM6 A32 A4 See pag. 23
EST31
3000 /PL
Z--
EST32
3200 Italgroup
EST33 internal code
3500
DISTRIBUTOR See pag. 177-180
D31B D31BJ
D36B D36BJ
D310B D310BJ
D40 D40J
D47 D47J
D416 D416J
D75 D75J
D90 D90J
See pag. 174-175

EXAMPLES:

R8D 2200 H6 A1 D90J


R8D 3000 H6 A0 D90 SB9
R8D 2500/C H6 A0 D90J CCW SB9

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 133
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

134 R8D rev.00 - Oct. 2018


R8D H7
R8D H7 Pag. 136 - 139

R8D H7/C Pag. 140 - 141

R8D H7/RM Pag. 142 - 143

R8D H7 - PERFORMANCE CURVES Pag. 144 - 148

R8D H7 - ORDERING CODE Pag. 149

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 135
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H7
32 36 DRAIN PORT
4
25 3/4" BSP

N°2 PORTS

8
1"1/2 SAE 6000

17

20,6°
0,05
457,15 -- 0,15
190

248

748
100

D90 (*)


52
0,
20 7
N°7 MTG HOLES 20,5
59 ON A 520,7 P.C.D.
MTG FACE

113 288 95
DRAIN PORT
3/4" BSP
Available distributor flange: FL16
For S04, refer to page 186-187
(distributor fitting D90)

TECHNICAL DATA
3400 3600 3900 4300 4600 5000 5400
DISPLACEMENT [cc] 3413 3650 3907 4343 4616 5088 5384
SPECIFIC TORQUE [Nm/bar] 54.3 58.1 62.2 69.1 73.5 81.0 85.7
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 270
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 200 185 175 160 150 140 130
PEAK SPEED (***) [rpm] 220 210 200 190 190 180 170
MAX. CONT. POWER (****) [kW] 238 238 238 238 238 238 230
MAX. POWER [kW] 265 265 265 265 265 265 258
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6
DRY WEIGHT [kg] 405 405 405 405 405 405 405
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D90) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

136 R8D rev.00 - Oct. 2018


35
963
.1960 M20 102 UNI 222
Z=16 B10x102x112 DIN 5463

MOUNTING FACE
ING FACE MOUNTING FACE

MOUNTING FACE

280

103
A1
A0

76

138138
MOUNTING FACE

35
103
76
Available spline billet:
173

35

Available spline billet:


F 2B 3/4"-16MOUNTING
UNF 2B FACE

144
BS3/4"-16 UNF 2B
3550 1963

35
963

280

SB11

SB10
.1960 ASA.B.5.15.1960

138
W100x4x24-7h M20 102 UNI 222
Z=23 PITCH 6/12 Z=20

103
DIN 5482

76
B10x102x112 DIN 5463

173

35
144
3/4"-16 UNF 2B

35
MOUNTING FACE MOUNTING FACE
W100x4x24-7h M20 102 UNI
DIN 5482 MOUNTING FACE222

249
B10x102x112 DIN 5463

138
103
76
MOUNTING FACE

35
MOUNTING FACE MOUNTING FACE

280
173
3/4"-16 UNF 2B
144

138
103
35

76

138
BS 3550 1963
249173

103
35
ASA.B.5.15.1960

76
M20 102 UNI 222

A11
144
A01

PITCH 5/10 Z=16

35
3/4"-16 UNF 2B B10x102x112 DIN 5463
35
173

3/4"-16 UNF 2B
144

Available spline billet:

W100x4x24-7h M20 102 UNI 222


35

DIN

right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
BS 5482
3550 1963 B10x102x112 DIN 5463
MOUNTING FACE MOUNTING FACE
SB11

ASA.B.5.15.1960 M20 102 UNI 222


PITCH 5/10 Z=16 B10x102x112 DIN 5463
MOUNTING FACE MOUNTING FACE

138
138
103

103
76

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
76
249
35

35

138
MOUNTING FACE MOUNTING FACE

103
76
3/4"-16 UNF 2B 3/4"-16 UNF 2B
SHAFTS

137
173

138
BS 3550 1963 BS 3550 1963
138

3/4"-16 UNF 2B
144

35 103
ASA.B.5.15.1960
76

ASA.B.5.15.1960
76
103 35

PITCH 6/12 Z=20


35

PITCH 6/12 Z=23

35
6
173
MOUNTING FACE

35
144

280
3/4"-16 UNF 2B

35

138
138
W100x4x24-7h M20

103
76
91
91 DIN 5482 B1

24
173

24
35
144

3/4"-16 UNF 2B
35

MOUNTING FACE
MOUNTING FACE
MOUNTING FACE
W100x4x24-7h M20
OUNTING FACE
OUNTING FACE
DIN 5482 B1
249

R8D H7

46
138

46
103

188
76

A2

188
A12

149
140

149
140
MOUNTING FACE

35

55
173

35
35
3/4"-16 UNF 2B
144

Available spline billet:


249
35

138
3/4"-16
3/4"-16 UNF 2B
UNF 2B BS 3550 1963

103
+0.011

76
85+0.011
∅∅85 -0,009 ASA.B.5.15.1960
-0,009 M20

SB27
35
PITCH 5/10 Z=16 B1
173

3/4"-16 UNF 2B
144

35

BS 3550 1963
ASA.B.5.15.1960
MOUNTING FACE M20
106
106 PITCH 5/10 Z=16

24
24
B1

138
138

FACE
103

103
OUNTING
OUNTING FACE
76

76
35

MOUNTING FACE
MOUNTING FACE
MOUNTING FACE 35
3/4"-16 UNF 2B 3/
138
B
138

BS 3550 1963
103

103

133
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

204
76

133
76

204
ASA.B.5.15.1960 AS
A13

A21
0,5

149
140
,5
35

149
140
35

PIT

33
PITCH 6/12 Z=23

35
35
3/4"-16 UNF 2B 3/
Available spline billet:

25,
25,44
3/4"-16
3/4"-16 UNF 2B
UNF 2B BS 3550 1963 B
2A +0.02
1/2-12
1/2-12 UNF
UNF 2A 100+0.02 ASA.B.5.15.1960 AS
SB24

∅∅100 00
PITCH 6/12 Z=23 PIT

R8D rev.00 - Oct. 2018


140 140

3/4"-1
3/4"-1

3/4"-16
3/4"-16
MOU
MO

MO
M
24 24
24 24

106
91

106
91

35 35
35

∅85+0.011
35

∅100+0.02
149

-0,009
∅85+0.011

∅100+0.02
149

-0,009
149

0
149

0
188
188 204
204
SHAFTS

A3 A4
MOUNTING FACE

MOUNTING FACE
MOUNTING FACE

1"1/2-12 UNF 2A
MOUNTING FACE
133

1"1/2-12 UNF 2A
133

25,4
46

25,4
46

10,5
10,5

∅95.5
∅95.5
∅99,4
∅115

∅99,4
∅115

8 TAPER 1:10
N85x3x27-9H

8 0 TAPER 1:10
N85x3x27-9H

58,6
DIN 5480

0 -1,6
58,6-1,6
DIN 5480

62
62
183 67
183 67
250
250

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 139
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H7/C
36 DRAIN PORT
4
39 3/4" BSP

10

N°2 PORTS

8
17
1"1/2 SAE 6000

- 0,05
400 - 0,15

540
190

584
100

D90 (*)

748
MTG FACE

N°5 MTG HOLES 23


59 ON A 540 P.C.D. 95
14 DRAIN PORT
113 327 3/4" BSP

Available distributor flange: FL8


Refer to page 186-187
(distributor fitting D90)

TECHNICAL DATA
3400 3600 3900 4300 4600 5000 5400
DISPLACEMENT [cc] 3413 3650 3907 4343 4616 5088 5384
SPECIFIC TORQUE [Nm/bar] 54.3 58.1 62.2 69.1 73.5 81.0 85.7
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 270
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 200 185 175 160 150 140 130
PEAK SPEED (***) [rpm] 220 210 200 190 190 180 170
MAX. CONT. POWER (****) [kW] 238 238 238 238 238 238 230
MAX. POWER [kW] 265 265 265 265 265 265 258
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6
DRY WEIGHT [kg] 405 405 405 405 405 405 405
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D90) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

140 R8D rev.00 - Oct. 2018


116

28
116
116 116

28
28 28
MOUNTING FACE
MOUNTING FACE MOUNTING FACE
MOUNTING FACE MOUNTING
MOUNTING
FACEFACE

210
MOUNTING
MOUNTING
FACEFACE

210

210
173
160
A0

6
144

210
210210
35
A2

173
160
210210173 173
173173

Available spline billet:


35

160160 6
6 6
144
144144

173173 35
35 35
M20 M20

35
35 35
102 UNI 222

SB11
M20 M20
M20 M20 B10x102x112
102 UNI 5463
DIN222
110+0.023
∅ +0,013 M20 M20
102 102
UNI UNI
B10x102x112
222 DIN
222 5463
110+0.023
∅ +0,013 B10x102x112
B10x102x112
DIN DIN
54635463
∅ 110+0.023
110+0.023

+0,013
+0,013

MOUNTING FACE

35
MOUNTING FACE

14
MOUNTING
MOUNTING
FACEFACE

210

35
35 35
MOUNTING FACE

14
14 14
210

82
MOUNTING FACE

50
A11

MOUNTING
MOUNTING
FACEFACE

82
144

82 82
50
50 50
M16
210210173 173
173173
35

N100x3x32-9H M16
144
144144

DIN 5480

A3

right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
N100x3x32-9H M16 M16
35
35 35

N100x3x32-9H
N100x3x32-9H
DIN 5480 ∅130 M20
DIN DIN
54805480 M20
∅130 W110x4x26-8e
M20 M20
∅130∅130 DIN 5480
W110x4x26-8e
W110x4x26-8e
W110x4x26-8e
DIN 5480

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
DIN DIN
54805480
SHAFTS

141
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H7/RM

36 DRAIN PORT
4
39 3/4" BSP
10
N°2 PORTS
1"1/2 SAE 6000

8
17

20,6°
- 0,05
320 - 0,15
190

584

748
100

D90 (*)


52
0
59
MTG FACE

N°7 MTG HOLES 22


ON A 520 P.C.D.
113 325 95
DRAIN PORT
3/4" BSP

TECHNICAL DATA
3400 3600 3900 4300 4600 5000 5400
DISPLACEMENT [cc] 3413 3650 3907 4343 4616 5088 5384
SPECIFIC TORQUE [Nm/bar] 54.3 58.1 62.2 69.1 73.5 81.0 85.7
MAX. CONT. PRESSURE [bar] 270 270 270 270 270 270 270
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 200 185 175 160 150 140 130
PEAK SPEED (***) [rpm] 220 210 200 190 190 180 170
MAX. CONT. POWER (****) [kW] 238 238 238 238 238 238 230
MAX. POWER [kW] 265 265 265 265 265 265 258
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6
DRY WEIGHT [kg] 405 405 405 405 405 405 405
TEMPERATURE RANGE (**) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) The standard distributor (D90) is shown. Please refer to distributors section (pag. 174-175) for differents distributor interfa-
ces.
- (**) Please refer to the hydraulic fluid recommendations (pag. 10-11).
- (***) Do not exceed maximum power (see pag. 13).
- (****) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

142 R8D rev.00 - Oct. 2018


SHAFTS
MOUNTING FACE

A11
218
150

140
M24

∅106 h12

50
W110x4x26-7h

4.15 H13
DIN 5480

115

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 143
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H7 - PERFORMANCE CURVES


R8D 3400 H7

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 3600 H7

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

144 R8D rev.00 - Oct. 2018


R8D 3900 H7

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 4300 H7

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 145
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H7 - PERFORMANCE CURVES


R8D 4600 H7

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 5000 H7

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

146 R8D rev.00 - Oct. 2018


R8D 5400 H7

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 147
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H7 - PERFORMANCE CURVES


CREEP SPEED - VOLUMETRIC EFFICIENCY

3600 3900 4300 25 50 100 200

3400 4600
1,5
5000

creep speed [rpm]


5400 cc
1
10 rpm

0,5

0
0 1 2 3 4 5 90 95 100
external leakage [l/min] volumetric efficiency [%]

0 50 100 150 200 250


pressure [bar] Reference viscosity: 40 cSt

Example:
We suppose (5400 cc): p=200 [bar], we obtain: external leakage 4,3 [l/min], shaft creep speed 1 [rpm].
If we suppose (5400 cc): p=200 [bar] and n=100 [rpm] we obtain a volumetric efficiency of 98,5%;

BEARING LIFE
Reference displacement 4600 cc
n=25 n=50

n=75
n=100
n=125 250 bar
n=200 EX 2
n=300 180 bar

120 bar
EX 1
60 bar

L50h 100000 50000 20000 10000 5000 2000 1000


a =2
30000 3000 00
mm
20 kN
Fr Sh
Fr a=1
50
af
ts
mm tre
ss
Fr=radial load 40 kN a=
100 lim
a=distance of radial load from mounting face mm it
n=shaft speed [rpm] 60 kN a=
50
mm
a 80 kN
Reference viscosity: 40 cSt

Example:
We suppose (EX1): p=120 [bar], n=200 [rpm]; we obtain an average lifetime of 20000 [h].
If we suppose (EX2): Fr=20 [kN], a=100 [mm], n=100 [rpm] and p=250 [bar] we obtain an average life-
time of 4000 [h].

148 R8D rev.00 - Oct. 2018


R8D H7 - ORDERING CODE

R8D -- -- H7 -- -- -- -- SB -

TACHOMETER

TA SPECIAL SPLINE
DISPLACEMENT INTERCHANGEABILITY SHAFT FEATURES BILLET
TB
3400 /C A0 A01 MP SB10
SERIE
TT1
3600 /RM A1 A11 SPSL SB11
H7 TQ1
3900 A12 A13 HPS SB24
EST
4300 A2 A21 CCW SB27
EST30
4600 A3 A4 See pag. 23 See pag. 181-185
EST31
5000
Z--
EST32
5400 Italgroup
EST33 internal code
DISTRIBUTOR See pag. 177-180
D90 D90J
See pag. 174-175

EXAMPLES:

R8D 4600 H7 A1 D90 CCW


R8D 5000 H7 A0 D90 SB10
R8D 5400/C H7 A0 D90

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 149
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

150 R8D rev.00 - Oct. 2018


R8D H8
R8D H8 Pag. 152 - 154

R8D H8/C Pag. 156 - 157

R8D H8 - PERFORMANCE CURVES Pag. 158 - 161

R8D H8 - ORDERING CODE Pag. 162

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 151
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H8

TECHNICAL DATA
3000 6000 6500 6800 7600 8000
DISPLACEMENT [cc] 3020 5966 6581 6962 7620 8062
SPECIFIC TORQUE [Nm/bar] 48.1 95 104.7 110.8 121.3 128.3
MAX. CONT. PRESSURE [bar] 270 250 250 250 250 240
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 240 120 120 120 90 80
PEAK SPEED (**) [rpm] 300 140 140 140 100 90
MAX. CONT. POWER (***) [kW] 215 215 215 215 215 215
MAX. POWER [kW] 236 236 236 236 236 236
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6
DRY WEIGHT [kg] 590 590 590 590 590 590
TEMPERATURE RANGE (*) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) Please refer to the hydraulic fluid recommendations (pag. 10-11).


- (**) Do not exceed maximum power (see pag. 13).
- (***) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

152 R8D rev.00 - Oct. 2018


SHAFTS

A0 A01

DIN ISO 14 - 10x82x92


UNI 8953 - 10x82x92
MOUNTING FACE

MOUNTING FACE

82 UNI 221
260 166,5
112 UNI 222

188 110
M16

M16
150 90

35 35

Available spline billet: SB12 Available spline billet: SB10

A1 A11
MOUNTING FACE
MOUNTING FACE

PITCH 6/12 Z=23


ASA.B.5.15.1960
PITCH 6/12 Z=20
ASA.B.5.15.1960

BS 3550 1963
BS 3550 1963

3/4"-16 UNF 2B
3/4"-16 UNF 2B

140 122
114 101

35 35
184
184

Available spline billet: SB24

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 153
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
154
91

24
24

40

13
91 MOUNTING FACE
R8D H8
MOUNTING FACE

89
70
184
A2

140
130
M16

5
100x94

A3
35
DIN 5482
∅130 3/4"-16 UNF 2B
∅85+0.011
-0,009

106

24
24

MOUNTING FACE

106
MOUNTING FACE

184
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

122
184

102
A5
119
115
A22

35
35

3/4"-16 UNF 2B
3/4"-16 UNF 2B
W100x4x24-7h ∅100+0.02
0
DIN 5480

R8D rev.00 - Oct. 2018


SHAFTS

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 155
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H8/C
N°5 MTG HOLES 342 DRAIN PORT
25 ON A 600 P.C.D. 3/4" BSP
4
30 17

N°2 PORTS
2" SAE 3000

450-0,05
-0,15
250

660
120

D200 600

695
15

96
MTG FACE

DRAIN PORT 135


3/4" BSP DRAIN PORT
160,5 451 3/4" BSP

TECHNICAL DATA
3000 6000 6500 6800 7600 8000
DISPLACEMENT [cc] 3020 5966 6581 6962 7620 8062
SPECIFIC TORQUE [Nm/bar] 48.1 95 104.7 110.8 121.3 128.3
MAX. CONT. PRESSURE [bar] 270 250 250 250 250 240
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 240 120 120 120 90 80
PEAK SPEED (**) [rpm] 300 140 140 140 100 90
MAX. CONT. POWER (***) [kW] 215 215 215 215 215 215
MAX. POWER [kW] 236 236 236 236 236 236
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6
DRY WEIGHT [kg] 590 590 590 590 590 590
TEMPERATURE RANGE (*) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) Please refer to the hydraulic fluid recommendations (pag. 10-11).


- (**) Do not exceed maximum power (see pag. 13).
- (***) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

156 R8D rev.00 - Oct. 2018


SHAFTS

A0 A11
MOUNTING FACE

MOUNTING FACE
230 230

W120x4x28-8e
112 UNI 222

DIN 5480
188 188
M16

M16
150 150

35 35

Available spline billet: SB12


MOUNTING FACE

A2 A3
MOUNTING FACE

50
4

180 40
M16

32
M16
138

138

∅160

14
N110x3x35-9H

32 35
∅124 h8

DIN 5480

90
188
230

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 157
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H8 - PERFORMANCE CURVES


R8D 3000 H8

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 6000 H8

350 bar

300 bar

250 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

158 R8D rev.00 - Oct. 2018


R8D 6500 H8

350 bar

300 bar

250 bar

180 bar

120 bar

60 bar

R8D 6800 H8

350 bar

300 bar

250 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 159
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H8 - PERFORMANCE CURVES


R8D 7600 H8

350 bar

300 bar

250 bar

180 bar

120 bar

60 bar

R8D 8000 H8

320 bar

280 bar

240 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

160 R8D rev.00 - Oct. 2018


CREEP SPEED - VOLUMETRIC EFFICIENCY
3000 6000 25 50 100 200
6500
1,5
6800

creep speed [rpm]


7600
8000 cc
1
10 rpm

0,5

0
0 1 2 3 4 5 90 95 100
external leakage [l/min] volumetric efficiency [%]

0 50 100 150 200 250


pressure [bar] Reference viscosity: 40 cSt

Example:
We suppose (8000 cc): p=200 [bar], we obtain: external leakage 4,3 [l/min], shaft creep speed 0,95 [rpm].
If we suppose (8000 cc): p=200 [bar] and n=100 [rpm] we obtain a volumetric efficiency of 98,5%;

BEARING LIFE
Reference displacement 6800 cc
n=25 n=50 n=75 n=100
n=120

EX 2 250 bar
bar
180

EX 1 120 bar

60 bar

L50h 250000 100000 50000 20000 10000 5000 3000 1000 a =2


00
200000 30000 4000 2000 mm
40 kN
Fr
Fr a=150 mm

Fr=radial load 80 kN
a=distance of radial load from mounting face a= a=
50 1
n=shaft speed [rpm] mm 00 m
m
120 kN

a 150 kN
Reference viscosity: 40 cSt
Example:
We suppose (EX1): p=120 [bar], n=100 [rpm]; we obtain an average lifetime of 85000 [h].
If we suppose (EX2): Fr=80 [kN], a=50 [mm], n=50 [rpm] and p=250 [bar] we obtain an average lifetime
of 9000 [h].

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 161
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H8 - ORDERING CODE

R8D -- -- H8 -- -- -- -- SB -

TACHOMETER

TA SPECIAL SPLINE
DISPLACEMENT INTERCHANGEABILITY SHAFT FEATURES BILLET
TB
3000 /C A0 A01 MP SB10
SERIE
TT1
6000 A1 A11 SPSL SB12
H8 TQ1
6500 A2 A22 HPS See pag. 181-185
EST
6800 A3 A5 CCW
EST30
7600 See pag. 23
EST31
8000
Z--
EST32
Italgroup
EST33 internal code
DISTRIBUTOR See pag. 177-180
D200 D200J
See pag. 174-175

EXAMPLES:

R8D 3000 H8 A1 D200


R8D 6500/C H8 A0 D200 CCW
R8D 6800 H8 A4 D200 EST30

162 R8D rev.00 - Oct. 2018


R8D H9
R8D H9 Pag. 164 - 165

R8D H9/C Pag. 166 - 167

R8D H9 - PERFORMANCE CURVES Pag. 168 - 172

R8D H9 - ORDERING CODE Pag. 173

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 163
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H9
85,5
449 DRAIN PORT
23 1" BSP

N°2 PORTS

898
2" SAE 6000

510-0,05
-0,15
305
290

347

198
145

40

D202
MTG FACE

80
00
DRAIN PORT
Ø6

162 373 145 N°7 MTG HOLES


1" BSP
(535) 31 ON A 600 P.C.D.

TECHNICAL DATA
7000 8000 9000 10000 11000 12000 13000
DISPLACEMENT [cc] 7050 8332 8757 10214 11016 12073 13020
SPECIFIC TORQUE [Nm/bar] 112 132.6 139.4 162.6 175.3 192.2 207.3
MAX. CONT. PRESSURE [bar] 270 270 260 250 250 250 250
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 160 135 130 110 105 95 90
PEAK SPEED (**) [rpm] 190 160 155 135 120 110 105
MAX. CONT. POWER (***) [kW] 330 330 330 330 330 330 330
MAX. POWER [kW] 370 370 370 370 370 370 370
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6
DRY WEIGHT [kg] 750 750 750 750 750 750 750
TEMPERATURE RANGE (*) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) Please refer to the hydraulic fluid recommendations (pag. 10-11).


- (**) Do not exceed maximum power (see pag. 13).
- (***) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

164 R8D rev.00 - Oct. 2018


SHAFTS

A1 A3

MOUNTING FACE

MOUNTING FACE
MOUNTING FACE

MOUNTING FACE

W140x5x26-8f

W140x5x26-8f 104,5 104,5


DIN 5480

205 205 DIN 5480


M20

M20

167 167

M16

M16
40 40

∅160

∅160
35 35
10 10

N100x3x32-9H

N100x3x32-9H
DIN 5480

DIN 5480
115 115

291,5 291,5

Available only for


7000 - 8000 -9000 - 10000 cc

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 165
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H9/C
44
449 DRAIN PORT
41,5 1" BSP
15

N°2 PORTS

898
2" SAE 6000

450-0,05
-0,15

600

675
305
290

347

198
145

D202

8,5
N°5 MTG HOLES 33

80
ON A 600 P.C.D.
MTG FACE

00
162 414,5 DRAIN PORT Ø6 145
1" BSP
(576,5)

TECHNICAL DATA
7000 8000 9000 10000 11000 12000 13000
DISPLACEMENT [cc] 7050 8332 8757 10214 11016 12073 13020
SPECIFIC TORQUE [Nm/bar] 112 132.6 139.4 162.6 175.3 192.2 207.3
MAX. CONT. PRESSURE [bar] 270 270 260 250 250 250 250
HYDROSTATIC TEST PRES- [bar] 420 420 420 420 420 420 420
SURE
MAX. CONT. SPEED [rpm] 160 135 130 110 105 95 90
PEAK SPEED (**) [rpm] 190 160 155 135 120 110 105
MAX. CONT. POWER (***) [kW] 330 330 330 330 330 330 330
MAX. POWER [kW] 370 370 370 370 370 370 370
MAX. CASE PRESSURE [bar] 6 6 6 6 6 6 6
DRY WEIGHT [kg] 750 750 750 750 750 750 750
TEMPERATURE RANGE (*) [°C] -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70 -30÷70

- (*) Please refer to the hydraulic fluid recommendations (pag. 10-11).


- (**) Do not exceed maximum power (see pag. 13).
- (***) For motor operation with a continuous duty cycle at maximum continuous power the flushing is usually required. For
more information please contact our technical department.

166 R8D rev.00 - Oct. 2018


SHAFTS

A1 A3

MOUNTING FACE

MOUNTING FACE
MOUNTING FACE

MOUNTING FACE

205 205
W140x5x26-8f

W140x5x26-8f

50 50
DIN 5480

DIN 5480

167 167
M20

M20

40 40

M16

M16
∅160
∅160
35 35 14 14

N110x3x35-9H

N110x3x35-9H
DIN 5480

DIN 5480
90 90
250 250

Available only for


8000 cc

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 167
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H9 - PERFORMANCE CURVES


R8D 7000 H9

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

R8D 8000 H9

350 bar

300 bar
270 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

168 R8D rev.00 - Oct. 2018


R8D 9000 H9

350 bar

300 bar
260 bar

180 bar

120 bar

60 bar

R8D 10000 H9

350 bar

300 bar

250 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 169
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H9 - PERFORMANCE CURVES


R8D 11000 H9

350 bar

300 bar

250 bar

180 bar

120 bar

60 bar

R8D 12000 H9

350 bar

300 bar

250 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

170 R8D rev.00 - Oct. 2018


R8D 13000 H9

350 bar

300 bar

250 bar

180 bar

120 bar

60 bar

Continuous operation
The above diagrams are referring to the hydraulic motor wor-
Continuous operation with flushing or intermittent ope- king with a fluid in ideal conditions (viscosity at 40 cSt). In
ration (see below for intermittent operation) case the working temperature increases and viscosity reach
Intermittent operation: permitted for a 15% of values under the recommended values (see hydraulic fluid
duty cycle, for 3 minutes maximum period recommendations) flushing must be performed or ISO oil
grade must be changed. The working temperature must not
Peak operation: permitted for very short
overcome 70 °C.
periods (3-5 seconds every 10-15 minutes)

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 171
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

R8D H9 - PERFORMANCE CURVES


CREEP SPEED - VOLUMETRIC EFFICIENCY
7000 9000 11000 25 50 100 200

12000 0,15

creep speed [rpm]


8000 10000

0,1 10 rpm

13000 cc
0,05

0
0 0,5 1 1,5 99 99,5 100
external leakage [l/min] volumetric efficiency [%]

0 50 100 150 200 250


pressure [bar] Reference viscosity: 40 cSt

Example:
We suppose (13000 cc): p=200 [bar], we obtain: external leakage 1,2 [l/min], shaft creep speed 0,12 [rpm].
If we suppose (13000 cc): p=200 [bar] and n=25 [rpm] we obtain a volumetric efficiency of 99,5%;

BEARING LIFE
Reference displacement 10000 cc
n=10

n=25

n=50 bar
250
EX 2
n=100 bar
180
EX 1
bar
120
ba r
60

L50h 100000 50000 20000 10000 5000 2000 1000


30000 3000 a=3
00 m
Fr
m
100 kN a= Sh
Fr
200
mm aft
st
a= re
Fr=radial load 10 ss
0m li m
a=distance of radial load from mounting face 200 kN m it
a=
n=shaft speed [rpm] 50
mm

300 kN
a
Reference viscosity: 40 cSt

Example:
We suppose (EX1): p=250 [bar], n=100 [rpm]; we obtain an average lifetime of 2000 [h].
If we suppose (EX2): Fr=200 [kN], a=50 [mm], n=25 [rpm] and p=250 [bar] we obtain an average lifetime of
3100 [h].

172 R8D rev.00 - Oct. 2018


R8D H9 - ORDERING CODE

R8D -- -- H9 -- -- -- --

TACHOMETER

TA SPECIAL
DISPLACEMENT INTERCHANGEABILITY SHAFT FEATURES
TB
7000 /C A1 A3 MP
SERIE
TT1
8000 A31 SPSL
H9 TQ1
9000 HPS
EST
10000 CCW
EST30
11000 See pag. 23
EST31
12000
Z--
EST32
13000 Italgroup
EST33 internal code
DISTRIBUTOR See pag. 177-180
D202 D202J
See pag. 174-175

EXAMPLES:

R8D 13000 H9 A0 D202


R8D 8000/C A3 D202
R8D 10000 H9 A3 D202 EST

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 173
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

∅D
A
S D.
B
OLE .C.
H 5P

MOTOR DISTRIBUTORS C

2
5
N ° ON
, 5
TG 10
M A∅
E

∅1

D40-D416-D31B-D310B-D36B-D316B D47-D75-D90-D202

S
N°4+4 V x W mm deep
∅1
∅1 5

N°2N°2
PORTS
PORTS
0
05

N°2 PORTS
F F

∅O
R

∅U
T
∅D
∅D
A
A

∅N
L
S S D. D.
B B
OLE OL.EC. .C. M
H H5 P 5 P H

P. ES
D.
TG T∅G10∅10
E E

∅Q OL
C.
C C M M
5 5A A

A GH
N° NO°N ON

ON M T
5 5
2, 2,
∅1 ∅1

∅P °5
N

S S
N°4+4
N°4+4
V xVWx mm
W mm
deep
deep
D200
N°2N°2
PORTS
PORTS
∅O
∅O

R R
∅U
∅U

S
N°8 MTG HOLES ∅P
N°4+4 VxW mm deep ON A ∅Q P.C.D.
T
T

N°2 PORTS
R
G
G

∅N
∅N
T

L L
M M
H H
∅N
G
A QG PH LES
P. .DE.S
D.
∅Q .OCL
C.
ON AM∅T HO
∅P O°N5 TG
N M
∅P °5
N

L
U

M
Ø
2

H

174 R8D rev.00 - Oct. 2018


D40 D416 D31B D310B D36B D316B D47 D75 D90 D200 D202
A [mm] 69 69 56 56 56 56
B [mm] 41 41 39 39 39 39
C [mm] 77 77 67 67 67 67
D [mm] 130 130 125 125 125 125
E [mm] 68 68 65 65 65 65
1” 1” 3/4” 3/4”
F [] 1” BSP 1” SAE
BSP SAE BSP SAE

G [mm] 69 83 100 120 145


H [mm] 77 107 113 155 162
L [mm] 41 55 59 96 80
M [mm] 65 92 95 135 145
N [mm] 130 170 190 250 300
O [mm] 105 145 149 222 240
P [mm] 12,5 14,5 14,5 16,5 30,5
Q
1”1/2 1”1/2
1” SAE 2” SAE 2” SAE
R [] SAE SAE
3000 3000 6000
3000 6000
S [mm] 52,4 69,85 79,4 77,77 96,8
T [mm] 26,2 35,7 36,7 42,9 44,5
U [mm] 25 39 40 44 50
V [mm] M10 M12 M16 M12 M20
W [mm] 19 22 22 24 37

D31B D310B D36B D40 D416 D47 D75 D90 D200 D202
MAX. CONT. FLOW [l/min] 200 300 200 300 300 300 600 700 850 1000
MAX. FLOW [l/min] 400 400 400 400 400 400 1000 1200 1500 2000
MAX. CONT. PRESSURE [bar] 300 300 300 300 300 300 300 300 300 300
PEAK PRESSURE [bar] 500 500 500 500 500 500 500 500 500 500

R8D H2
R8D H3
R8D H4
R8D H45
R8D H5
R8D H55
R8D H6
R8D H7
R8D H8
R8D H9

Standard version
Special version: available on request. Please contact Italgroup for more details
The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 175
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

TACHOMETERS
J

Tacho drive plug 1/2” BSP

DISTRIBUTOR TYPE A
D40/D416/D47 75,5
D31B/D310B/D36B/D316B 63,5
D75 101
D90 107

Tachometer predisposition ONLY


10,5 A

TA

20
M18x1

DISTRIBUTOR TYPE A
3

D40/D416/D47 114,5
D31B/D310B/D36B/D316B 102,5
D75 140
17
D90 146
22

176 R8D rev.00 - Oct. 2018


TB

22
3

DISTRIBUTOR TYPE A
20 H8

D40/D416/D47 125,5
D31B/D310B/D36B/D316B 113,5
M8 D75 151
10 D90 157
26,5
32

TT1

DETAIL X

7,5

DE 2 M8
6

PT
H1
2m
2,6 +- 0,1

m
0

DISTRIBUTOR TYPE A
5
D40/D416/D47 90,5
X D31B/D310B/D36B/D316B 78,5
D75 116
22 H7
64

48

D90 122

7 12

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 177
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

TACHOMETERS
TQ1


DE 2 M8
PT
H1
2m
m
8 h8

DISTRIBUTOR TYPE A
D40/D416/D47 90,5
22 H7
64

48

D31B/D310B/D36B/D316B 78,5
D75 116
D90 122
15 12

EST
7

9
6

DISTRIBUTOR TYPE A
120
°

D40/D416/D47 87,5
D31B/D310B/D36B/D316B 75,5
85

46
6 f7

D75 113
D90 119

N°3 M4
DEPTH 9 mm
10 A 40
N°4 M3
DEPTH 6 mm

178 R8D rev.00 - Oct. 2018


EST 30

8 DISTRIBUTOR TYPE A
M5x1
D40/D416/D47 93,5
D31B/D310B/D36B/D316B 81,5
D75 119
29

D90 125
89

60

EST 30 ELECTRIC DATA


POWER SUPPLY 10 - 30 VDC
IMPULSE / RPM 30
PROTECTION DEGREE IP67
28 A OUTPUT NPN / PNP (*)

(*) Customer has to select it at the order


stage. In case of non-indication by cu-
stomer, NPN version will be supplied as
standard.

EST 31

TACHOMETER
TACHOMETER
WIRE WIRE

DISTRIBUTOR TYPE A
D40/D416/D47 93,5
D31B/D310B/D36B/D316B 81,5
89

58
89

58

D75 119
D90 125

54 54 A A EST 31 ELECTRIC DATA


POWER SUPPLY 8 - 24 VDC
IMPULSE / RPM 500
PROTECTION DEGREE IP65
OUTPUT PUSH-PULL

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 179
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

TACHOMETERS
EST 32

HOLE FOR M16x1,5


CABLE GLAND IP68

DISTRIBUTOR TYPE A
D40/D416/D47 93,5
D31B/D310B/D36B/D316B 81,5
D75 119
D90 125

34 EST 32 ELECTRIC DATA

69 A POWER SUPPLY 8 - 24 VDC


IMPULSE / RPM 4096
PROTECTION DEGREE IP67
OUTPUT SSI interface

EST 33

M12x1 THREAD
FOR TACHOMETER FITTING

DISTRIBUTOR TYPE A B
D40/D416/D47 99,5 88
89

D31B/D310B/D36B/D316B 87,5 76
D75 125 113,5
D90 131 119,5

SENSOR NOT INCLUDED


B

180 R8D rev.00 - Oct. 2018


5
46
∅34,5

75
69
∅66

93
∅98
∅42,3

18
∅72,5
26 UNI 221

46
BS 3550 1963
46 UNI 220

22
SA B.5.15.1960 36 UNI 221

3 26
∅58

3
TCH 6/12 Z=14 ∅64 62 UNI 221
∅66 ∅34,5

69
∅82 28 UNI 221

93
∅38,3

18
∅98 ∅78

46
∅66

22
∅88 ∅98
∅54,3 ∅50,3
∅42,3 36 UNI 221 ∅58

3
∅62,5 ∅72,5 62 UNI 221

61
∅32,5

22
∅82 28 UNI 221

3
22

3026
∅58

18
∅98 ∅66

18
SB1
∅34,5

SB3

SB5
75
∅42,3

94
∅78

69
∅72,5

102
46

75
32 UNI 221

93
∅88 ∅50,3 ∅58
∅48,5

18

For:
∅62,5

26
∅32,5 ∅58
46

R8D
BS 3550 1963 26 UNI 221
∅34,5

R8D 3
69
46 UNI 221 46 UNI
36220
UNI 221

18
3 3
ASA B.5.15.1960

93
62 UNI 221

R8D H4 A1
For: R8D 80-195

For: R8D H3/C A1


PITCH 6/12 Z=14

R8D H3/GM3
∅64

H3/S A0
R8D H2/S A0
75
∅64
18
46

∅82 28 UNI 221

R8D3800 H3 A11
75

A0
∅66

R8D H2/GM2 A0
R8D 80-195 H1 A1
18 H1 A0

R8D 800/N H3 A11


46

∅88

22 R8D 400-600 H2 A0

22 350-700 H3 A0
∅38,3
∅78 36 UNI 221

3
∅108 62 UNI 221 ∅98
BS 3550 1963 ∅50,3 26 UNI 221

3
∅88

3
∅82,1 ∅82 ∅54,3 46 UNI 220 22 ∅58 28 UNI 221
∅62,5 ASA B.5.15.1960 ∅32,5
∅64∅66
61

∅98PITCH 6/12 Z=14

22

22
∅78
∅42,3 ∅66

30
3

18
∅88 ∅72,5
18

∅88 ∅50,3 ∅38,3 ∅58

75
46

75
94

22
∅108 62,5 ∅98 ∅ 32,5

102

26
∅58 32 UNI 221
22

22
∅82,1 ∅54,3 ∅ 34,5
∅48,5
SB4
SB2

SB6

18
69
18

93
61

BS 3550 1963 26 UNI 221


75

3
22
3
46 UNI 220
46

30
3
18

75
ASA B.5.15.1960 46 UNI 221
72 UNI 221
46

PITCH 6/12 Z=14 ∅64


∅64
94

∅66

102
36 UNI 221

right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
∅88 62 UNI 221 32 UNI 221
BS 3550 1963 ∅38,3 26 UNI 221

3 3
3
46 UNI 220 ∅48,5
∅108∅82 ASA B.5.15.1960 28 UNI 221
∅98
PITCH 6/12 Z=14 ∅64
22

∅82,1

3
∅54,3 46 UNI 221 ∅66

R8D H4 A0

R8D H5 A0
∅78

For: R8D H45 A0


∅88
For: R8D 200-300

72 UNI 221

R8D H45/C A0
R8D H2/PH A0
61

∅38,3
R8D H2/B10 A0

For: R8D 800 H3 A0


R8D H2/C190 A0

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
∅88 64
∅∅50,3

22
R8D 800/N H3 A0
∅58
30
3
H1 A0
R8D 200-350 H2 A0

∅62,5∅108 ∅98
∅32,5
22

R8D 1000-1500/C H5 A0
∅82,1
22
∅54,3
94

102

18
32 UNI 221
61
SPLINE BILLETS

181
22
75

30
18 3

∅48,5
46

75
3
94

102
∅72,5

22

25
26
∅98 ∅66
∅42,3
69

100

182
∅72,5

93

80
22

26
BS 3550 1963
ASA B.5.15.1960
69

36 U

3
∅74 62 UNI 221

93
∅52
98UNI 222
∅58,6 PITCH 6/12 Z=14
∅48,1 ∅82

∅160 ∅148 ∅78 36 UN

3
62 UNI 221

22
∅112,1 ∅92,1 ∅88 ∅50,3
∅82
∅62,5

62
22

25
∅98 ∅74

105
∅78

18
∅58,6 ∅48,1

26 40
∅88 ∅50,3
SB7
75

SB9

SB11
180
124
75

90
∅148 ∅62,5
42 UNI 222
22

40

22
BS 3550 1963 ∅92,1
ASA B.5.15.1960 BS 3550 1963

18 3

3
3
75

62
102 UNI 222 82 UNI 221 46 U
ASA B.5.15.1960
75

105
56 UNIPITCH
221 8/16 Z=17
∅112,1 PITCH 6/12 Z=14 ∅64

For: R8D H7 A0
R8D H6 A0
26 40
For: R8D H55 A0
R8D H5 A1

R8D H7/C A0
R8D H6/C A0
For: R8D H45 A1

R8D H55/C A0
∅88

124
SPLINED BILLETS

∅98 BS 3550 1963


3
∅148
3

42 UNI 222 46 U
∅60,1

40
∅108 ASA B.5.15.1960 ∅98
BS 3550 1963 ∅90 PITCH 6/12 Z=14 ∅64
∅82,1 ∅54,3
ASA B.5.15.1960
PITCH 8/16 Z=17 82 UNI 221 ∅88

16
25
22
30

∅108 ∅98

100
58

80
∅∅98 ∅148 ∅82,1 ∅54,3
102

∅ 60,1
∅34,5
∅90
22

BS 3550 1963 BS 3550 1963


30

ASA B.5.15.1960 ASA B.5.15.1960

16
25

18
PITCH 5/10 Z=16 52 UNI 222
3

SB8
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

PITCH 6/12 Z=14


94

46 U

SB14
SB10
102

72 UNI 221

46
100

80
∅64
21
∅98 ∅160
BS 3550 1963
3

∅65,5 28 UNI 221 ∅112,1 BS 3550 1963 46 UN

R8D H1 A11
ASA B.5.15.1960 ASA B.5.15.1960 72 UNI 221

R8D H1/BH A0
52 UNI 222

R8D H7 A1
∅64

R8D H6 A1
PITCH 5/10 Z=16

137
R8D H1/GM1 A0
For: R8D 1600-2200/C A0

For: R8D H55 A1


PITCH 6/12 Z=14

For: R8D H1/GM05 A0


25

30
9858
∅∅ ∅160
180

90
65,5
∅∅ 32,5 ∅112,1

137
25
3

18
102 UNI 222

R8D rev.00 - Oct. 2018


30 3
56 UNI 221

46
∅112,1
180

90
∅75
PITCH 8/16 Z=17

100

80
∅148
∅87 BS 3550 1963 BS 3550 1963
ASA B.5.15.1960 ASA B.5.15.1960
PITCH 5/10 Z=16 52 UNI 222
PITCH 6/12 Z=14

∅148

28
∅98 BS 3550 1963 ∅74 ∅98 ∅160
∅87
∅58,6
ASA B.5.15.1960 ∅48,1 ∅65,5 ∅98 ∅74
∅112,1
PITCH 6/12 Z=23 ∅58,6 ∅48,1

113
∅98 ∅148 ∅74

137
25

22

31
∅58,6 ∅92,1 ∅48,1

30

28
∅148

62
22

31

105
∅98 ∅92,1

180
∅148

90
3x12-7e ∅58,6

26 40

10

113
SB17
22
SB15

31

SB24

137
5480
62 ∅92,1

124
∅57
42 UNI 222

105
∅98
62

40
∅89

31
∅58,6
BS 3550 1963
26 40

105
∅98 102 UNI 222
ASA B.5.15.1960

The data specified into the catalogue are for product description purpose
56 UNI 221 82 UNI 221

10
∅58,6
26 40

PITCH 8/16 Z=17 ∅112,1 42 UNI 222

105
∅57
40

∅75 ∅98

For: R8D H4/S A0


∅74

31
For: R8D3H2/C300 A0
42 UNI 222

For: R8D H6 A11


∅102

R8D H7 A13
∅98 BS 3550 1963 ∅58,6

R8D H4/GM4 A0
∅48,1

R8D H5/GM5 A0

57 only and 30
40

∅148

57
ASA B.5.15.1960

31
∅60,1 BS 3550 1963
PITCH ∅90 Z=17 82

57
BS 3550 1963 ASA8/16
B.5.15.1960

105
ASA B.5.15.1960 PITCH 8/16 Z=17 8
22

16
31

25

105
PITCH 8/16 Z=17 100
∅98

30
∅148
62

80
∅60,1
∅98
105

∅148 ∅98

30
∅90
∅148
∅88 ∅58,6
26 40

BS 3550 1963 BS 3550 1963 BS 3550 1963


∅60,1
∅87 ∅90
∅55,5 ASA B.5.15.1960 ASA B.5.15.1960 ASA B.5.15.1960
16
25

PITCH 5/10 Z=16 BS 3550 1963


52 UNI 222 42 UNI 222
PITCH Z=17 PITCH 6/12 Z=14
40

ASA8/16
B.5.15.1960
16
25

31
BS 3550 1963
PITCH 8/16 Z=17

17
80

57
ASA B.5.15.1960

28
∅98 ∅160
∅148 PITCH 8/16 Z=17
80

∅65,5
SB21
SB16

∅112,1
105
∅148 BS 3550 1963

79

113
∅87 B

137
25

SB27
B.5.15.1960
ASA BS 3550 1963 ∅98 AS

30

30
∅87 PITCH Z=16 52 UNI 222
ASA5/10
B.5.15.1960 ∅60,1 PIT
For: R8D H4/C

52 UNI 222

90
PITCH 5/10 Z=16

right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
10
BS 3550 1963
180 A0

R8D H4/B45 A1
For: R8D H3/B30 A0

For: R8D H6 A12


R8D H7 A12
∅57 N55x3x17-9H ASA B.5.15.1960
16
25

28
DIN 5480 ∅98 ∅160
∅89 PITCH 8/16 Z=17
3

102 UNI 222 ∅65,5

28
∅98 ∅112,1
∅160

3
∅72 56 UNI 221
∅112,1

113
∅65,5 ∅112,1
137

∅75 ∅148
80 25

113
BS 3550 1963

must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
137
30

∅87
25

ASA B.5.15.1960
52 UNI 222
30

PITCH 5/10 Z=16


180

90

10
90

∅57

183
10
28

∅98
∅89∅57
3

∅65,5 102 UN
3

∅89 56 UNI 221


3

113

102
137

∅112,1
2
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

SPLINED BILLETS
SB30

N55x3x17-9H
DIN 5480
137 79

∅55,5
∅88

∅72
∅102
∅57

17 3
28 10
113 For: R8D H3/B30 A1
R8D H3/C A11
R8D H4/B45 A4
W40x3x12-7e
DIN 5480

100
36 UN I 220

100
58x53 DIN 5482

111
184 R8D rev.00 - Oct. 2018
PITCH 6/12 Z=23
ASA B.5.15.1960
3550 1963

N55x3x17-9H
DIN 5480
∅55,5
∅88

∅72
∅148 BS 3550 1963∅148

∅102
∅87

∅57
137 79
6/12 Z=23
ASA B.5.15.1960
BS

N55x3x17-9H
DIN 5480
17 79
PITCH

137 3
28 10

∅55,5
∅88

∅72
SPLINED BARS

∅102
∅87

∅57
113

∅55,5
∅88

∅72
B8076
∅148

∅102
∅87

∅57
17 3
28 10
W40x3x12-7e

113
DIN 5480

17 3
28 10
113

100
W40x3x12-7e
DIN 5480

For: R8D H3 A31


R8D H3/GM3 A31
R8D H3/S A31
W40x3x12-7e
DIN 5480

100
36 UN I 220

B8078
100
100
36 UN I 220
36 UN I 220

100
58x53 DIN 5482

For: R8D 200-350 H2 A3


R8D 400-600 H2 A3
100 R8D H2/GM2 A3
R8D H2/S A3
R8D H3 A3
R8D H3/GM3 A3
R8D H3/S A3
58x53 DIN 5482

111
B8079
58x53 DIN 5482

111

111

For: R8D H4 A3

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 185
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

ADAPTOR FLANGES
FL1 FL2 FL4

38
38
38

38

40
38
38

38

38

40
40
38

38

40

40
N°6 M10
N°6N°6
M10M10
N°6 M8 N°6 M10
N°6 M10
N°6N°6
M8 M8 25 mm
25 mm DEEP 25 mm DEEP
DEEP 60
22 mm
N°622
DEEP
M8
N°6
mmM8
DEEP 25 mm mm DEEP 60 60
25DEEP
22 mm DEEP
50 50 50 60 60
22 mm22DEEP
mm DEEP N°6 M12
50 50 N°6N°6
M12M12
N°6 M12
N°6 M12 73 73 73
DEEP 21 mm DEEP

40
4076
21 mm
21 mm DEEP
7640
40
76

73 73
76

21 mm21DEEP
mm DEEP
40
76
34
3476
7634
76
34
76

34
76

60 60 60 60 60 60

50
5090
50
50
90
90
50 50 60 60 60 60

50
90

90
50 50 50 50 N°2 ∅25
50 5050 50 N°2N°2∅25∅25 142142 142
N°2 ∅20 N°2 ∅N°2
25 ∅25
∅20∅20
N°2N°2
125125 125 142 142
N°2 ∅N°2
20 ∅20
125 125 68 68 68 68 68 68
68 68 68 68
N°2 ∅31 162
∅31∅31
N°2N°2
31 ∅31 162162 162 162
N°2 ∅N°2

Connection block, fitting D47 distributor, for Connection block, fitting D47 distributor, for Connection block, fitting D75 distributor, for
motor MR125/160/190/200/250/300/330 motor MR350/450/500/600/700/800 motor MR1100/1400/1600/1800/2100

FL5 FL6
45
45
45

45
45
45
45

45

45

45

N°6N°6 3/8"-24 N°6 3/8"-24


3/8"-24 60 N°6N°6 3/8"-24 N°6 3/8"-24
3/8"-24
N°6 2B,
UNF 3/8"-24
N°6 3/8"-24 60 60 51
UNF 2B, 16 mm
UNF 2B, 16 mm DEEP DEEP 16 mm DEEP 60 60 UNFUNF
2B, 2B, 16 mm
16 mm
N°6 2B,
UNF
DEEP
3/8"-24
N°6 3/8"-24 51 51
DEEP 16 mm DEEP
UNF 2B,
UNF162B,
mm16DEEP
mm DEEP UNF 2B,
UNF162B,
mm16DEEP
mm DEEP 51 51
44
4490

44
4490
44
44
90
90

44
44
90
90
44
90

90

44
90

90

51 51 51 51 51 51 48 48
48 48 48 48
N°2 ∅28 51 5151 51 N°2 ∅31 48 4848 48
∅28∅28
N°2N°2 148 ∅31∅31
N°2N°2 148

N°2 with
N°2
28 OR 148148
∅284137 ∅
N°2 with
N°2
31 OR 148148
∅314150
withwith
OR OR
41374137 148 148 withwith
OR OR
41504150 148 148
with OR
with4137
OR 4137
housing with OR
with4150
OR 4150
housing
housing
housing housing
housing
housing
housing housing
housing

Connection block, fitting D75 distributor, for Connection block, fitting D75 distributor, for
motor HMB 60/80/100 - S03 motor HMB 60/80/100 - S04

186 R8D rev.00 - Oct. 2018


FL7 FL8
58

5858

47
58

4747
47
N°6 M16 N°6 M16
N°6 3/8"-24N°6 3/8"-24 N°632M16 N°6 M16 116 116
N°6 50,8 mm DEEP32 mm DEEP 116 116
UNF 2B,3/8"-24
16 UNF
mm DEEP N°6 3/8"-24
2B, 16 mm DEEP 50,8 32 mm DEEP 32 mm DEEP
UNF 2B, 16 mm DEEP UNF 2B, 16 mm DEEP50,8 50,8

108
68

108
44,4

6868
110

44,4

108

108
110

68
44,4

44,4
110

110

N°2 ∅38 N°2 ∅38


N°2 ∅32 N°2 ∅32 47,6 47,647,6 47,6 N°2 ∅38 N°2 ∅38 100 100100 100
N°2
with OR ∅32housing 47,6
4150 47,6
N°2 ∅32 47,6 47,6 100 100100 100
with OR 4150 housing 230 230
with OR 4150 housing 165
with OR 4150 housing 165 230 230
165 165

Connection block, fitting D90 distributor, for Connection block, fitting D90 distributor, for
motor HMB 125/150/200 - S04 motor MR 3600/4500, MRE 5400

FL10 FL16
40

4040

58

5858
40

58

N°6 M14 N°6 M14 N°6 3/8"-24N°6 3/8"-24


N°628M14
mm DEEP N°6 M14 86 UNFN°6
2B,3/8"-24
16 UNF
mm DEEP N°6 3/8"-24 66,7 66,7
28 mm DEEP 86 2B, 16 mm DEEP66,7 66,7
28 mm DEEP 28 mm DEEP 86 86 UNF 2B, 16 mm DEEP UNF 2B, 16 mm DEEP
50,8
110

50,8
110
90
62

50,8

50,8
9090
6262

110

110
90
62

N°2 ∅37 90 9090 90


N°2 ∅37 90 ∅∅37
N°2
N°2 37 90 90 90 N°2 ∅35 N°2 ∅35
210 with N°2 ∅35housing
O-Ring N°2 ∅3560 6060 60
210 with O-Ring60
housing
210 210 with O-Ring housing
∅45x2,8 mmwith O-Ring housing 60
DEEP 60 60
∅45x2,8 mm DEEP 165 165
∅45x2,8 mm DEEP ∅45x2,8 mm DEEP 165 165

Connection block, fitting D75 distributor, for Connection block, fitting D90 distributor, for
motor MR 2400/2800, MRE 3100 motor HMB 270/325 - S04

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 187
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

188 R8D rev.00 - Oct. 2018


R 8 D - V A LV E S
SINGLE OVERCENTER - OVSA 160 Pag. 190

DOUBLE OVERCENTER - OVDA 160 Pag. 191

FLUSHING - AP 40 Pag. 192

DOUBLE RELIEF - RVDA 80 Pag. 193

ANTICAVITATION - AC 80 Pag. 194

DOUBLE RELIEF AND ANTICAVITATION - RVDAC 80 Pag. 195

DOUBLE RELIEF AND FLUSHING - RVDAP 80 Pag. 196

SINGLE RELIEF AND ANTICAVITATION - RVSAC 200 Pag. 197

DOUBLE OVERCENTER - OVDA 300 Pag. 198

DOUBLE RELIEF - RVDA 200 Pag. 199

SINGLE RELIEF AND OVERCENTER - ORVSA 200 Pag. 200

DOUBLE RELIEF AND SINGLE OVERCENTER - DRVSO200EP Pag. 201

DOUBLE OVERCENTER - OVDA 480 Pag. 202

DOUBLE RELIEF - RVDA 380 Pag. 203

SINGLE RELIEF AND OVERCENTER - ORVSA 480 Pag. 204

DOUBLE RELIEF AND FLUSHING - RVDAP 90 Pag. 205

VALVES ORDERING CODE Pag. 206

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 189
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

SINGLE OVERCENTER - OVSA 160


(225)
75 (225) 150
75 150
F
F ∅25

78
(225)

55
C1 ∅25 C2
78
55 75 150
C1 C2 O-ring 4137 (2-220)
F 195
O-ring 4137 (2-220)
195 106 ∅25
78

69
55

106 C2 (225)
C1
69 75 150
O-ring V2
4137 (2-220)
V1 195
52.4

52.4
F V2
78

106
PORTS DIMENSION V1 ∅25
52.4

52.4

69
78
78

55

V1, V2 1” BSP C2
C1
F 1/4” BSP 26.2 V2 26.2
V1 O-ring 4137 (2-220)
195
52.4

52.4

C1, C2 O-Ring 4137 26.2 26.2


78

Parker code 2-220 106 ∅10.5


MTG HOLES
N°4+4
SPOT FACING ∅16.5
DEPTH 10.5
69
N°4+4 ∅10.5 MTG HOLES
26.2 SPOT FACING ∅16.5
26.2DEPTH 10.5
V2
V1
52.4

52.4

N°4+4 ∅10.5 MTG HOLES


78

TECHNICAL DATA
SPOT FACING ∅16.5 DEPTH 10.5

26.2 26.2

OVSA.160.1.D47 N°4+4 ∅10.5 MTG OVSA.160.3.D47


OVSA.160.2.D47 HOLES
SPOT FACING ∅16.5 DEPTH 10.5
NOMINAL FLOW [l/min] 120 120 120
MAXIMUM FLOW [l/min] 160 160 160
MAXIMUM PRESSURE [bar] 350 350 350
PILOT RATIO [] 1 (3:1) 2 (4.5:1) 3 (10:1)
RELIEF VALVE SETTING RANGE [bar] 70-280 140-350 140-350
STANDARD RELIEF SETTING [bar] 210 210 210
BLOCK MATERIAL [] steel steel steel
DISTRIBUTOR FITTING [] D47 C1 D47 C2 D47

pilot opening
C1 C2
C1 C2
30
Cartridge characteristic Hydraulic circuit
pilot opening
30 pilot opening free flow C1 C2
30 20
[bar]

free flow pilot opening


loss [bar]

20 free flow
20 30
10
[bar]

Pressure [bar]

free flow
20
10 10
[bar]

0
0 30 6010 90 120
0 0
0 30 30 [l/min] V1 F V2
0 60 60 90090 120
120
Flow [l/min]
[l/min]
[l/min] 0 30 60 90 120 V1 F F V2 V2
[l/min]
V1
V1 F V2
190 R8D rev.00 - Oct. 2018
DOUBLE OVERCENTER - OVDA 160
(240)
120 120
(240)
(240)
120 F 120
120 120
78 (225) ∅25

55
F
75 F 150
78
∅25O-ring 4137 (2-220)
78

∅25

55
~305
55
F
143
69 ∅25 O-ring 4137 (2-220)
78

O-ring 4137 (2-220)


55

C2~305
C1 ~305
143
V1 143 V24137 (2-220)
69 O-ring
69
52.4
C1
195 C2

52.4
78

106
PORTS DIMENSION
V169 V2
V1 V2
52.4
C1 C2

52.4
V1, V2 1” BSP
78

26.2
52.4

C1 C2

52.4
78

F 1/4” BSP 26.2


V2
V1
52.4

52.4

C1, C2 O-Ring 4137 N°4+4 ∅10.5 MTG


26.2 HOLES
78

Parker code 2-220 26.2


26.2SPOT FACING ∅16.5 DEPTH 10.5
26.2
26.2 N°4+4 ∅10.5 MTG HOLES
N°4+4 ∅26.2
10.5 MTG HOLES
SPOT FACING ∅16.5 DEPTH 10.5
SPOT
N°4+4 ∅10.5 ∅
FACING 16.5
MTG DEPTH 10.5
HOLES

TECHNICAL DATA
SPOT FACING ∅16.5 DEPTH 10.5

OVDA.160.1.D47 OVDA.160.2.D47 OVDA.160.3.D47


NOMINAL FLOW [l/min] 120 120 120
MAXIMUM FLOW [l/min] 160 160 160
MAXIMUM PRESSURE [bar] 350 350 350
PILOT RATIO [] 1 (3:1) 2 (4.5:1) 3 (10:1)
RELIEF VALVE SETTING RANGE [bar] 70-280 40-350 140-350
STANDARD RELIEF SETTING [bar] 210 210 210
BLOCK MATERIAL [] steel steel steel
DISTRIBUTOR FITTING [] D47 D47 D47

C1 C1 C2 C2
pilot opening
Cartridge characteristic Hydraulic circuit
30
pilot opening
free flow C1 C2
30
20 pilot opening C1 C2
pilot opening
loss [bar]

30 free flow
[bar]

3020
free flow
Pressure [bar]

10 free flow
20
2010
[bar]
[bar]

0
10 0 0 10 30 60 90 120 V1 F V2
0 30 60[l/min]
90 120
0Flow [l/min]
[l/min] V1 F V2
0 0 30 60 90 120 V1 F V2
0 60 30 90 120 V1 F V2
[l/min]
The data specified into the catalogue are for[l/min]
product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 191
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

FLUSHING - AP 40
152 152
152

152
F F
F

103
103

103
∅25 ∅25
∅25
52
52

52
C1 C1 C2 C2
C1
F C2
103

26.2 26.2 O-ring


4137 4137 (2-220)
26.2 ∅2526.2
26.2 26.2 O-ring O-ring(2-220)
4137 (2-220)
52

C1 C2

V1 V1 V2 4137 V2
26.2 V1 26.2 O-ring V2 (2-220)
52.4

52.4
52.4

52.4
80

52.4

52.4
80

PORTS DIMENSION
80

V1, V2 1” BSP
V1 V2
F 1/4” BSP
52.4

52.4
80

69 69
C1, C2 O-Ring 4137 69
Parker code 2-220
N°4+4 ∅10.5∅MTG
N°4+4
N°4+4
10.5 HOLES
∅10.5MTG HOLES
MTG HOLES
69 ∅
SPOTSPOT FACING
FACING ∅16.5 16.5 DEPTH
DEPTH 10.5 10.5
SPOT FACING ∅16.5 DEPTH 10.5
N°4+4 ∅10.5 MTG HOLES
SPOT FACING ∅16.5 DEPTH 10.5
TECHNICAL DATA
AP40.D47
MAXIMUM FLUSHING FLOW [l/min] 80
MAXIMUM PRESSURE [bar] 350
BLOCK MATERIAL [] steel
DISTRIBUTOR FITTING [] D47

Cartridge characteristic Hydraulic circuit

30 30
30
30 C1 C1
C1 C2 C2
C2
pressure [bar]

24 24 C1 C2
24
24

18 18
18
[bar]

18
[bar]

[bar]
Return line[bar]

12 12
12 12

66 6
6

00 0
00 20
00
0 20
2040 40
20
40
60 60
40
60
80
60 80
80
80
V1 V1 V1
V1
F F FV2
F V2 V2
V2
Flow [l/min]
[l/min] [l/min]
[l/min] [l/min]

192 R8D rev.00 - Oct. 2018


DOUBLE RELIEF - RVDA 80 ~230
142
~230

~230142
142 ~230

78
∅25
142
78 C1 C2
∅25
C1 C2 26.2 ∅25 O-ring 4137 (2-220)
78

26.2
78

∅25
C1 C2
C1 C226.2 O-ring 4137 (2-220)
26.2
V1 V2
52.4 O-ring 4137 (2-220)

52.4
26.2 26.2
78

O-ring 4137 (2-220)


26.2 26.2
V1 V2
52.4

52.4 52.4
52.4 78

PORTS DIMENSION
V1 V1
V2 V269

52.4
V1, V2 1” BSP
52.4
78

78

C1, C2 O-Ring 4137


Parker code 2-220 69 N°4+4 ∅10.5 MTG HOLES
SPOT FACING ∅16.5 DEPTH 10.5
69 69
N°4+4 ∅10.5 MTG HOLES
SPOT FACING ∅16.5 DEPTH 10.5
N°4+4 ∅10.5 MTG HOLES
N°4+4 ∅10.5 MTG HOLES
SPOT FACING ∅16.5 DEPTH 10.5
SPOT FACING ∅16.5 DEPTH 10.5

TECHNICAL DATA
RVDA.80.C.D47
NOMINAL FLOW [l/min] 150
MAXIMUM FLOW [l/min] 200
MAXIMUM PRESSURE [bar] 350 Hydraulic circuit
RELIEF VALVE SETTING RANGE [bar] C (20-350)
STANDARD RELIEF SETTING [bar] 20 C1 C2
BLOCK MATERIAL [] steel
DISTRIBUTOR FITTING [] D47 C1C1 C2
C2

400 typical pressure rise


Cartridge C1 C2
pressure [bar]

400 300
400
300
[bar]

200
400 300
Differential[bar]

200
100
[bar]

300 200
100
0
[bar]

200 100 0 50 100 150


0 V1 V2
0 50 100[l/min] 150
100 0 Flow[l/min]
[l/min] V1 V2
0 50 100 150
[l/min]
V1 V2
0
0 50 100 150
[l/min]
V1 V2
The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 193
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

ANTICAVITATION - AC 80
142 142
142
142

∅25 ∅25∅25
AC ACAC ∅25

58
AC

58

58
58

19
19

19
19
C1 C1C1 C2 C2C2
C1 C2 O-ring 4137 (2-220)
O-ring 4137 (2-220)
O-ring 4137 (2-220)
26.2 26.2 26.2
26.2 26.2 26.2 O-ring 4137 (2-220)
26.2 26.2

V1 V1V1
V2 V2V2
52.4

52.4
V1
52.4

52.4
78

52.4

52.4
V2
78

78
52.4

52.4
PORTS DIMENSION
78

V1, V2 1” BSP
AC 1/4” BSP
69 69
69
C1, C2 O-Ring 4137 69
Parker code 2-220
N°4+4 N°4+4
∅10.5
N°4+4
∅10.5
MTG MTG HOLES
HOLES
∅10.5 MTG HOLES
SPOT
SPOT FACINGFACING
SPOT∅N°4+4
∅ 16.5
∅10.5
16.5 DEPTH
FACING
DEPTH
MTG
10.5
∅16.5 10.5
HOLES
DEPTH 10.5
SPOT FACING ∅16.5 DEPTH 10.5

TECHNICAL DATA
AC80.D47
NOMINAL FLOW [l/min] 150
MAXIMUM FLOW [l/min] 200
MAXIMUM PRESSURE [bar] 350
MAXIMUM ANTICAVITATION FLOW (FROM AC TO C1 OR C2) [l/min] 50
BLOCK MATERIAL [] steel
DISTRIBUTOR FITTING [] D47

Check valve flow/pressure curve


C1 C1C1 C2 C2C2
8 8
8 C1 C2
pressure [bar]

8
[bar]
Delta pressure [bar]

Delta pressure [bar]

6 6
pressure [bar]

6
Delta pressure

6
4 4
4
4
2
V1V1AC ACACV2 V2V2
Delta

2
2
2 V1
V1 AC V2
Delta

0 0
0
0 0
10
100 0 20 20
30
10 Flow 20
30
40 40
30 50 40
50
50
10[l/min]
0 Flow Flow
20 [l/min]
[l/min]
30 40 50
Flow [l/min]
Flow [l/min]
194 R8D rev.00 - Oct. 2018
RELIEF & ANTICAVITATION - RVDAC80 ~230

~230
~230
AC
142
AC
AC

108
∅2

108
108
AC

69
58
C1 C2

69
~230

69
C1 C2
C1 C2

19
142
∅25 O-Ring 4137 (2-220)
C1 C2
∅25 O-Ring 4137 (2-220)
∅25 O-Ring 4137 (2-220) O-rin
N °4 142
+
MT 4 Ø1
N °4
+4 142 26.2 26.2
GH 0 M Ø
OLE .N5°4+ TG H O 10.5 142
78

SM
TG
4 Ø LES
10.
∅25
H OL 5
C1 E
C2S
V1
V2

52.4
V1 V1 V2 V2

78
PORTS DIMENSION O-ring 4137 (2-220)
52.37

52.37
26.2 26.2
52.37

52.37
V2

78
V1

78
V1, V2 1” BSP
52.37

52.37

78
AC 1/4” BSP
V1 V2 69
C1, C2 O-Ring 4137 OT
52.4

52.4
5
SP 16.
78

26.19 26.19
Parker code 2-220 OT 5 +4 G Ø EEP
SP 16. °4 26.19 D
26.19
N°4+4 ∅10.5 M
4 Ø EE P N I N
4+ ACT m m 69
N° CING m D FO
SP 101.56.
5 26.19 69 26.19 SPOT FACING ∅16.5 D
A
F .5 m 4 Ø EP
4+ DE
10 N° CING m69 69
FA . 5 m
10

TECHNICAL DATA
N°4+4 ∅10.5 MTG HOLES
SPOT FACING ∅16.5 DEPTH 10.5

RVDAC80.C.D47
NOMINAL FLOW [l/min] 150 C1 C2
MAXIMUM FLOW [l/min] 200 C1 C2
MAXIMUM PRESSURE [bar] 350 C1 C2
RELIEF VALVE SETTING RANGE [bar] C (20-350)
STANDARD RELIEF SETTING [bar] 20
MAXIMUM ANTICAVITATION [l/min] 50
FLOW (FROM AC TO C1 OR C2)
BLOCK MATERIAL [] steel
DISTRIBUTOR FITTING [] C1 D47 C2

Relief cartridge typical pressure rise Check valve flow/pressure curve


C1
pressure [bar]

400 8
pressure [bar]
[bar]

300 6
V1 AC V2
Delta pressure
Differential[bar]

200 4

100 2 V1 AC V2 V1 AC
Delta

0
0
V1 AC V2
0 50 100 150
Flow[l/min]
[l/min] 0 10V1 20 30 V2
40 50
Flow [l/min]
Flow [l/min]
The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 195
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

RELIEF & FLUSHING - RVDAP80 ~230


142

~230
142

~230
F 142
~230

78
142 F
∅25

78
C1 ∅25 C2
F
C1 C2
F

78
O-ring 4137 (2-220)
26.2 26.2 O-ring 4137 (2-220)
∅25
78
26.2 26.2
∅25 C1 C2
39

39

~230 V1 V1C1 C2 V2V2

52.4

52.4
52.4
52.4

PORTS DIMENSION 142 26.2 26.2


118

O-ring 4137 (2-220)


118

V1, V2 1” BSP 26.2 26.2

39
F 1/4” BSP V1 V2

52.4
39

C1, C2 O-Ring 4137 V1 V2


69

52.4
118
Parker code 2-220 F
52.4

69 N°4+4 ∅10.5 MTG HOLES


118
78

SPOT FACING ∅16.5 DEPTH 10.5


∅25 N°4+4 ∅10.5 MTG HOLES
SPOT FACING ∅16.5 DEPTH 10.5
C1 C2
TECHNICAL DATA
400 69
300 69 N°4+4
O-ring 4137 (2-220)
400 26.2 26.2 SPOT FACING
[bar]

200 N°4+4 ∅10.5 MTG HOLES


RVDAP80.C.D47 C1 C2
SPOT FACING ∅16.5 DEPTH 10.5
300 VALVE MAXIMUM
RELIEF 100 FLOW [l/min] 200
39

RELIEF VALVE SETTING RANGE [bar]400 V1 C (20-350) V2


0
[bar]

52.4
52.4

200 0 50 100 150


400
STANDARD RELIEF SETTING [bar]
[l/min] 300 70 C1 C2
118

100
MAXIMUM
300FLUSHING FLOW [l/min] 80
[bar]

200
MAXIMUM PRESSURE
30
[bar] 350 Hydraulic circuit C1
[bar]

0 200
0BLOCK MATERIAL
50 100 []100
150 steel C1 C2
24
100 [l/min]
DISTRIBUTOR FITTING [] 0 D4769
18 0 50 100 150
N°4+4 ∅10.5 MTG HOLES
[bar]

0 [l/min]
0 12 50 100 150 SPOT FACING ∅16.5 DEPTH 10.5
30
Relief cartridge typical pressure rise [l/min] Flushing valve characteristic
6
30
pressure [bar]

24
pressure [bar]

400 0 V1 F V2
30 0 20 4024 60 80
300 18 [l/min]
[bar]

24 18
[bar]

Return line[bar]

200 12
18 C1 C2
Differential

12
[bar]

100 6
12 6
0
0 0 50 6 100 150 V1 F V2
0 20
[l/min] 40 60 0 80 V1
0 20 40 60 80
Flow [l/min]
0 [l/min] Flow [l/min]
[l/min]
V1 F V2
0 20 40 60 80
196 R8D rev.00 - Oct. 2018
30 [l/min]

24
RELIEF & ANTICAVITATION - RVSAC200

M2
M2 M2 M2

98
M1 M2

57

98
98
M1 M1 M1

22

57
57
57

98
M1 C1 C2

22
22
22

40

57
O-ring 4137 (2-220) C2
C1 C2 C2 C1
O-ring 4137 (2-220) C1
40

22
40 40 130
O-ring 4137 (2-220)
130 40
130 C1 C2 O-ring 4137 (2-220)
130
(70.5) 69 (70.5)
(70.5) (70.5) 130 (70.5) 69 (70
69 (70.5) (70.5)
69
(70.5) 69 (70.5)

V1
39
V1

39
V1
39

52.4
V1
39
52.4

V1 V2
39
V2 V2

52.4

128 128
52.4
128

V2 V2

128
26.2 26.2 26.2
26.2 26.2 26.2
PORTS DIMENSION 26.2 26.2
26.2 26.2
V1, V2 1” BSP
210 ~55 210
210 ~55
M1, M2 1/4” BSP
210 ~55
N°4+4 ∅10.5 MTG HOLES 210 ~55 N°4+4
C1, C2 O-Ring 4137 N°4+4 ∅10.5 MTG HOLES SPOT FAC
SPOT FACING ∅16.5 DEPTH 10.5 N°4+4 ∅10.5 MTGDEPTH
HOLES 10.5
SPOT FACING ∅16.5
SPOT∅FACING
Parker code 2-220 N°4+4 10.5 MTG HOLES
∅16.5 DEPTH 10.5
SPOT FACING ∅16.5 DEPTH 10.5

TECHNICAL DATA
RVSAC200.C.D47
RELIEF VALVE MAXIMUM FLOW [l/min] 200
MAXIMUM PRESSURE [bar] 350
RELIEF VALVE SETTING RANGE [bar] C (70-420)
STANDARD RELIEF SETTING [bar] 70
CHECK VALVE MAXIMUM FLOW [l/min] 160
BLOCK MATERIAL [] steel
Hydraulic circuit
DISTRIBUTOR FITTING [] C1 D47C2
C1 C2
C1 C2
Relief cartridge typical pressure rise Oil supply flow (from C2 to C1) C1 C2
drop [bar]
[bar]

400 12 400

12 400 300
9
Differential pressure

300
M1
[bar]

300
400M1 M2
[bar]

2009
[bar]

6 200
(C2-C1) pressure

12
M1100 M2
[bar]
[bar]

6 2003
12 100 400
9 300
3 1000 0
0
9 300
M1 M2
[bar]
[bar]

160 6 0 100 200 300 200 0 40 80 120 160 0 100 200 300
0 0
M1 M2
[bar]
[bar]

0V1 [l/min]
6
3
0 [l/min]
40Flow [l/min]120
80 200
160
100
100 [l/min]
Flow V2
[l/min]
200 300
[l/min] [l/min] V1 V2
3 100
0 0
0 40 80 120 160 0 100 200 300
0 The data specified into the catalogue are for product description 0
V1 V2 197
purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
0 40
right to implement 80[l/min] 120
modifications 0
160 All partial or total reproduction
without notice. and100 [l/min]
copy without 200 authorization
written 300of Italgroup S.r.l. is strictly forbidden.
[l/min] [l/min] V1 V2
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

DOUBLE OVERCENTER - OVDA 300


35.7 35.7
35.7 35.7
35.7 35.7

69.85

69.85
98
C1 C2

69.85

69.85
98
4M
TG C1 C2

69.85

69.85
98
.5 C1 C2
N °4+ S Ø1 2
4 MTG .5HO LE 93.5 83 93.5
+
N°4 ES Ø1
2 MTG .5
+4 2
H OL N°4 ES Ø1 93.5 83 (270) 93.5
L
HO 93.5 83 93.5
(270) ∅18.5
(270)
∅18.5
∅18.5
F
98

12.5

74
F
F
98

12.5
98

74
12.5
∅25

74
O-ring 4187 (2-225)
PORTS DIMENSION 170
∅25
V1, V2 1”1/4 BSP ∅25 O-ring 4187 (2-225)
170 O-ring 4187 (2-225)
F 1/4” BSP V1 170 V2
C1, C2 O-Ring 4187 V2
Parker code 2-225 V1 V2
V1
~360

~360

TECHNICAL DATA
~360

OVDA.300.1.D75 OVDA.300.4.D75 OVDA.300.2.D75


NOMINAL FLOW [l/min] 240 240 240
MAXIMUM FLOW [l/min] 300 300 300
MAXIMUM PRESSURE [bar] 350 350 350
PILOT RATIO [] 1 (3:1) 4 (10:1) 2 (4.5:1)
RELIEF VALVE SETTING RANGE [bar] 70-280 140-350 140-350
STANDARD RELIEF SETTING [bar] 210 210 210
BLOCK MATERIAL [] steel steel steel
DISTRIBUTOR FITTING [] D75 D75 D75
C1 C2
30
Cartridge characteristic Hydraulic circuit
C1 C2
20
pilot opening C1 C2
[bar]

30
30
loss [bar]

10
free flow
20
pilot20opening
[bar]

0 pilot opening
[bar]

0 60 120 180 240 V1 F V2


Pressure

10
10 [l/min]
free flow
free flow
0
0 0
60 120 180 240 V1 F V2
0 60
[l/min]
Flow [l/min]
120 180 240 V1 F V2
[l/min]
198 R8D rev.00 - Oct. 2018
DOUBLE RELIEF - RVDA 200
~260
18.5
~260

12.5
N°4+4 12.5 ~260
18.5

12.5
18.5
N°4+4 12.5

12.5
N°4+4 12.5
~260
18.5
∅28

12.5

98
N°4+4 12.5
∅28

98
∅28

98
C1 C2
83 O-ring 4187
SPOT
F
C2 C1
DEPT ACING ∅28 (2-225)

98
83 150
H 12
.5 m
ØS1P8.5
O
C1 C2 O-ring 4187
mD T FACIN (33.5) 83 (33.5)
150 (2-225)
SPOT E PT H G Ø18.5 83 O-ring 4187
FACI 12.5
DEPT N mm 150 (33.5) (2-225)
H 12 G Ø18.5 C1 C2 (33.5)
83
.5 m
m (33.5) (33.5) 83
SPOT
83
V2 O-ring 4187
PORTS DIMENSION FACI (2-225)

69.85
69.85

DEPT NG 150
H 12 Ø V2
98

.5 m 18.5
V1, V2 1”1/4 BSP m
V2

69.85
69.85

V1 (33.5) 83 (33.5)
98

69.85
69.85

C1, C2 O-Ring 4187


V1
98

Parker code 2-225


V1 35.7 35.7
5

V2
98 12.
Ø

69.85
69.85

35.7 35.7
.5
12 4+4

12
Ø

35.7 35.7
.5

V1
4
4+
Ø


4
4+

35.7 35.7
.5

TECHNICAL DATA
12
Ø
4
4+

RVDA.200.C.D75
RELIEF VALVE MAXIMUM FLOW [l/min] 200
MAXIMUM PRESSURE [bar] 350
RELIEF VALVE SETTING RANGE [bar] C (70-420)
STANDARD RELIEF SETTING [bar] 70
C1 C2
BLOCK MATERIAL [] steel
C1 C2
C1 C2
DISTRIBUTOR FITTING [] D75
Hydraulic circuit
C1 C2
400
Cartridge typical pressure rise
pressure [bar]

300 400
400
[bar]

200 300
300
Differential[bar]

100 200
400
[bar]

200
0 100
300 100
100 0
0
200 300 V1 V2
[bar]

[l/min]
0
200 0 100 200 300 V1 V2
0 100
100 200 Flow [l/min]
[l/min]
300 V1 V2
[l/min]
0
0 100 200 300 V1 V2
[l/min]

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 199
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

RELIEF & OVERCENTER - ORVSA 200


~45 ~45 228 228 ~43 ~43

~45 228 ~43

F F ~260
85 85

72

72
35.7
F
35.7
18.5

12.5
85

72
N°4+4 12.5
C1 C2 C1 C2
69.85

69.85
98

C1 83 C2 C1 83 C2
O-Ring 4187 (Parker 2-225)
O-Ring 4187 (Parker 2-225)
MTG .5
+4 2
N°4 ES Ø1 83
O-Ring 4187 (Parker 2-225)
HO
L
93.5 83 93.5 ∅28

(270)
V2 V2

69.85

69.85
69.85

69.85

∅18.5 C1 C2

98

98
V2
V1 V1 83

69.85
PORTS DIMENSION
69.85

SPOT

98
F
F .5 DEPT ACING Ø 150
V1, V2 1”1/4 BSP 8. 5 8 V1 H 12
.5 m 18.5
98

12.5

∅1 ∅1
35.71 35.71
35.71 N°
35.71 m N° (33.5)
74

G G MT 4+4 MT 4+4 83
CIN N
F 1/4” BSP I
FA 2,5
C
FA 44.5 .5 G. ∅ G ∅
, 5 18 131.5
44.5 131.5 H 12 N° . HO 12.
C1, C2 O-Ring 4187 O T 1 O T H 1G2 ∅ 35.71 35.71 OL .5
MT 4+4 LES 5
SP P TH SP
∅25 P TCIN ES
Parker code 2-225 DE DEFA ,5 G. ∅
44.5 131.5
O-ring 4187 (2-225) HO 12.
PO T 12 170 LE 5
S P TH

69.85
S
DE

98
V2 V1
V1

TECHNICAL DATA 35.7 35

.5
12
Ø
4
~360 4+

ORVSA.200.1.C.D75 ORVSA.200.4.C.D75 ORVSA.200.2.C.D75

NOMINAL FLOW [l/min] 240 240 240


MAXIMUM FLOW [l/min] 300 300 300
MAXIMUM PRESSURE [bar] 350 350 350
PILOT RATIO [] 1 (3:1) 4 (10:1) 2 (4.5:1)
OVC RELIEF VALVE SETTING RANGE [bar] 70-280 140-350 140-350
OVC STANDARD RELIEF SETTING [bar] 210 210 210
RELIEF VALVE SETTING RANGE [bar] C (70-420) C (70-420) C (70-420)
RELIEF STANDARD SETTING [bar] 70 70 70 C1
BLOCK MATERIAL [] steel steel steel
DISTRIBUTOR FITTING [] D75 C1 D75 C2
C1 C2
D75

C1 C2
30
OVC cartridge characteristic Relief cartridgeC1
typical pressure
C2rise
30 400 400
pressure [bar]

30 300 400 300


loss [bar]

20 3020 400
pilot opening pilot opening
[bar]

[bar]

[bar]

[bar]

200
300 200
300
20
10 pilot2010 pilot opening
opening
Pressure[bar]

free flow
[bar]

free100
flow
Differential[bar]

100
[bar]

200 200

0 10 10 0 0 0
0 120 0 180 60240 120 free flow
2400 100 100 200 0 300
100 200 300
60 free flow
180 100 [l/min] [l/min]
[l/min]
0 [l/min] 0
0 0 60 120 180 240 0
0 100 200 300 V1 F V1
V2 F V2
0 60 120 180 240 100V1 F V2300
[l/min]
[l/min] 0 200
V1 F V2 V1
Flow[l/min]
[l/min] Flow[l/min]
[l/min]
200 R8D rev.00 - Oct. 2018
RELIEF & OVERCENTER - DRVSO200EP
~285 ~285
~49 ~49 223.5 223.5

P P
∅25 ∅25

85
85
~260
35.7 35.7
18.5

12.5
C1 C2
N°4+4 12.5
C1 C2
40 100 O-Ring 4187 O-Ring 4187
40 C2 100
69.85

69.85
(Parker 2-225)
98

C1
(Parker
240 2-225)
MTG .5
240
+4 2
N°4 ES Ø1 36.7 36.7
HO
L
93.5 8336.7 93.5 36.7 ∅28

(270)
V1 ~285
V2
PORTS DIMENSION V1 ∅18.5 ~49
V2
223.5
C1 C2
79.4
108
79.4
108

V1, V2 1”1/4 BSP 83


SPOT
F
F DEPT ACING Ø P 150
P 1/4” BSP H 12
.5 m 18.5
98

12.5

∅25 m (33.5) (33.5)


74

83
C1, C2 O-Ring 4137 40 150

85
Parker code 2-220 40 150
∅25 C1 240 C2
O-ring 4187 (2-225) O-Ring 4187 V
170 240 40 100 N°4+4 ∅16.5 MTG HOLES

69.85
(Parker 2-225)
SPOT FACING ∅24.5 DEPTH 16.5
98
240
N°4+4 ∅16.5 MTG HOLES
36.7 36.7
V2 FACING ∅24.5 DEPTH 16.5
SPOT V1
V1

TECHNICAL DATA V1 V2

.5
35.7 35.7
79.4
108

12
Ø
4
4+

DRVSO200EP.1.C.D75
~360 DRVSO200EP.4.C.D75 DRVSO200EP.2.C.D75

40 150
NOMINAL FLOW [l/min] 240 240 240
240
MAXIMUM FLOW [l/min] 300 300 N°4+4 ∅16.5 MTG HOLES 300
SPOT FACING ∅24.5 DEPTH 16.5
MAXIMUM PRESSURE [bar] 350 350 350
PILOT RATIO [] 1 (3:1) 4 (10:1) 2 (4.5:1)
OVC RELIEF VALVE SETTING RANGE [bar] 70-280 140-350 140-350
OVC STANDARD RELIEF SETTING [bar] 210 210 210
RELIEF VALVE SETTING RANGE [bar] C (70-420) C (70-420) C (70-420)
RELIEF STANDARD SETTING [bar] 70 70 70 C1
BLOCK MATERIAL [] steel steel steel
C1 C2
DISTRIBUTOR FITTING [] D75 D75 D75
C1 C2
C1 C2
OVC cartridge
30 characteristic Relief
400cartridge C1
typical pressure
C2rise
pressure [bar]

30 400 300
loss [bar]

30
20 400
30 pilot opening 400
[bar]

300
[bar]

300
20 200
20 pilot opening
[bar]

pilot
10 opening
[bar]
Pressure[bar]

300 200
Differential[bar]

20 free
10 flow 200 100
pilot opening free flow
[bar]

100
10
[bar]

200 0
0 free flow 100120 0180 240 0
10 0
PP
60 0 100 200 300
0 60
120 180 240 0 100 200 300
0 free flow 100 [l/min]
[l/min]
[l/min]

[l/min] 0
0 60 120 180 240 0 100 V1 200F V2
300 V1
0 0
V2
0 120 Flow
[l/min]
180[l/min] 200Flow [l/min]
[l/min] V1
60 240 0 100 300
P
The data specified into[l/min]
[l/min]
the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
V1 V2 201

V1 V2
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

DOUBLE OVERCENTER - OVDA 480


170
170
170 35.7
35.7

F
118 FF C2

69.85

69.85
39

98
C1

118
39

118

89
39

89
MTG .5 C1 C2

89
+4
N°4 ES Ø1
2 C1
C1 C2
C2
L
HO 93.5 83 93.5
100 O-ring 4187
100
(270) (2-225) O-ring 4187
100 O-ring 4187
~60 340 (2-225)
~60
~60 (2-225)
~60 ∅340
34018.5 ~60
~60
36.7 36.7
36.7 36.7
36.7 36.7

F
98

12.5
V2

74
V2
V2
79.4

79.4
118

79.4

79.4
PORTS DIMENSION
118
79.4

79.4
118

V1 ∅25
V1, V2 1”1/2 BSP V1
V1 O-ring 4187 (2-225)
F 1/4” BSP 170

C1, C2 O-Ring 4187 (63.5) 213 (63.5)


(63.5) 213 (63.5)
Parker code 2-225 (63.5)
V1 213 V2
(63.5)
N°4+4 ∅16.5 MTG HOLES
∅N°4+4 ∅16.5 16.5
24.5 ∅DEPTH
SPOT FACINGN°4+4 MTG HOLES
16.5 MTG HOLES
SPOT FACING ∅24.5 DEPTH 16.5
SPOT FACING ∅24.5 DEPTH 16.5

TECHNICAL DATA
~360

OVDA.480.1.D90 OVDA.480.4.D90 OVDA.480.2.D90


NOMINAL FLOW [l/min] 480 480 480
MAXIMUM FLOW [l/min] 600 600 600
MAXIMUM PRESSURE [bar] 350 350 350
PILOT RATIO [] 1 (3:1) 4 (10:1) 2 (4.5:1)
RELIEF VALVE SETTING RANGE [bar] 70-280 140-350 140-350
STANDARD RELIEF SETTING [bar] 210 210 210
BLOCK MATERIAL [] steel steel steel
DISTRIBUTOR FITTING [] D90 D90 D90

Hydraulic circuit
Cartridge characteristic
C1 C1 C1 C2 C2 C2
30 30 C1 C2
loss [bar]

30 pilot opening
30 pilot opening
pilot opening
20
2020
Pressure[bar]

20 pilot opening
[bar]
[bar]
[bar]

10
1010 free flow
10 free flow
free
free flowflow
0
0 0
120 240 360 480
00 0 0 120 240 360 480
Flow [l/min]
120 240
120 360180 480 240
V1 V1 V1 F V2 V2
0 [l/min]
60 [l/min]
[l/min] F
[l/min] V1 FF V2V2
202 R8D rev.00 - Oct. 2018
DOUBLE RELIEF - RVDA 380 ~75 ~75

~75 ~75 ~75 ~75

118
C1 ~260 C2
18.5

12.5
118
118

N°4+4 12.5
(42,5) 100 (42,5)
O-ring 4187 (2-225)
C1 C1 C2 C2

V2
(42,5) (42,5)
100 100
(42,5) (42,5)
O-ring
∅28 4187
O-ring 4187 (2-225)
(2-225)
118

98
79,4

V1 V2 V2
C1 C2
118
118

79,4
79,4

83 O-ring 4187
SPOT 36,7
PORTS DIMENSION F (2-225)
DEPT ACING Ø 185 150
V1
H 12 V1
.5 m 18.5
V1, V2 1”1/2 BSP m (33.5) (33.5)
83 N°4+4 ∅16.5 MTG HOLES
C1, C2 O-Ring 4187 SPOT FACING ∅24.5 DEPTH 16.5
36,7 36,7
Parker code 2-225
185
185
V2
MTG∅HOLES
N°4+4 16.5 MTG HOLES

69.85
69.85

N°4+4 ∅16.5
98

SPOT
SPOT FACING FACING
∅24.5 ∅24.5
DEPTH DEPTH 16.5
16.5
V1

35.7 35.7
.5

TECHNICAL DATA
12
Ø
4
4+

RVDA.380.C.D90
RELIEF VALVE MAXIMUM FLOW [l/min] 380
MAXIMUM PRESSURE [bar] 350
RELIEF VALVE SETTING RANGE [bar] C (70-420)
STANDARD RELIEF SETTING [bar] 70 C1 C2
BLOCK MATERIAL [] steel
DISTRIBUTOR FITTING [] D90
C1 C1 C2
C2 circuit
Hydraulic
C1 C2
Cartridge typical pressure rise
400
[bar]

300
Differential pressure
[bar]

400 400 200


400

300 300
300 100
V1 V2
[bar]
[bar]

[bar]

200 200
200 0
0 100 200 300 400
100 100
100 Flow[l/min]
[l/min]
V1 V1 V2 V2
0 0 0
0 00
100 100
200
100
200
300
200
300
400 400 300 V1 V2
[l/min]
[l/min] [l/min]
The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 203
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

RELIEF & OVERCENTER - ORVSA 480


170 ~(391) ~(391)
~75 ~75
~60 ~45 250 228 ~81 ~43
~60 250 ~81

F
118

39
F F F

89
C2

118
C1 85
118
118

72
85 85
∅ 25 ∅ 25

90
90
C1 C2
100 C1 C24187
O-ring
C2 C2 C1 (2-225)
C1
~60 340 83 ~60 (42,5) 100 (42,5)
100 100 O-Ring 4187 (Parker 2-225) O
36.7 36.7 O-Ring 4187 (Parker 2-225)
O-Ring 4187 (Parker 2-225)

V2
V2 V2 V1 V1V2

118
V2

79,4
PORTS DIMENSION

69.85
79.4

79.4
79.4

79.4
69.85
118
118
79.4

79.4
118

98
V1, V2 1”1/2 BSP V1 V1
V1
F 1/4” BSP SP SP
O O
.5 D E T FA D E T FA
18 PT PNT°
C1, C2 O-Ring 4187 S
LENG
∅ ES 35.71 35.71 H1 C I 36,7
N H4 1 CING
L36.7 36.7 36.7 36.7 6.5 GMT∅2 + 46.5185 ∅21
Parker code 2-225 (63.5) HAOCI HO
213 (63.5) G .1H.5 ∅12 .5
+ 4 OTTGF 12+,45 TG 44.5 131.5
OL .5
M
4 S5P TH°4 5 M 150 150 35 35 E N°4+4 ∅16.5 M
°
N 6. EP N 16. S
N°4+4 ∅16.5 MTG HOLES SPOT FACING ∅2
∅1 D ∅
SPOT FACING ∅24.5 DEPTH 16.5

TECHNICAL DATA
ORVSA.480.1.D90 ORVSA.480.4.D90 ORVSA.480.2.D90
NOMINAL FLOW [l/min] 480 480 480
MAXIMUM FLOW [l/min] 600 600 600
MAXIMUM PRESSURE [bar] 350 350 350
PILOT RATIO [] 1 (3:1) 4 (10:1) 2 (4.5:1)
OVC RELIEF VALVE SETTING RANGE [bar] 70-280 140-350 140-350
OVC STANDARD RELIEF SETTING [bar] 210 210 210
RELIEF VALVE SETTING RANGE [bar] C (70-420) C1 C1 C (70-420)C2 C2 C (70-420) C1
RELIEF STANDARD SETTING [bar] 70 70 70
BLOCK MATERIAL [] steel steel steel
DISTRIBUTOR FITTING [] D90 D90 D90

OVC cartridge characteristic Relief cartridge typical pressure rise C1 C2

400 C1 C2
[bar]

30
loss [bar]

pilot
30 opening 400
300
Differential pressure

300
20 20
[bar]

pilot opening
Pressure[bar]

[bar]

200
[bar]

200
30 30 400 400
pilot pilot opening
10 opening 10
free flow free flow 100
300 300 100
20 20
0
0 0
V1
[bar]

[bar]
[bar]

0 0 100 200 300


0 120 240
60
360 200480
[l/min]
120 180
200
240
0 V1[l/min] V1 F F V2 V2
10 10 Flowfree
[l/min]
[l/min] 0 100 200 300 400
flow free100
flow V1 F V2
100
Flow[l/min] V1
[l/min] F V2
204
0 R8D rev.00 - Oct. 2018
0 0 0
0 120 0 240120 360240 480360 480 0 100 0 200100 300200 400300 400
[l/min] [l/min] [l/min] [l/min]
RELIEF & FLUSHING - RVDAP 90
~75 ~75

92.5
M2
118
F

~139.65
92.5 M1

119.5

57
C2 F

~139.65
C1

22
∅38

119.5
92.5

64.5
F 40 C1 C2

~139.65
∅38

64.5
130
119.5

(42,5) 100 (42,5)


∅38 C1 C2 O-ring 4187 (2-225) (70.5) 69 (
64.5

O-ring 4187 (2-225)


~75 C1 185 C2 ~75
V2 O-ring 4187 (2-225)
C1 C2 185 V1

39
~75 36.7 36.7 ~75
118

O-ring 4187 (2-225)


79,4

~75 36.7
185 36.7~75
V1 36.7 36.7 26.2
26.2
PORTS DIMENSION
V1 V2
79.4

79.4
120

V1, V2 1” BSP 36,7


V1 V2
79.4

79.4
210
120

185
F 3/8” BSP V1 V2
79.4

79.4
120

N°4+4 ∅16.5 MTG HOLES N°4


C1, C2 O-Ring 4187 SPOT FACING ∅24.5 DEPTH 16.5 SPOT F
Parker code 2-225 (42.5) 100 (42.5)

(42.5) 100 (42.5)


(42.5) 100 (42.5)

TECHNICAL DATA
RVDAP90.C.D90
RELIEF VALVE MAXIMUM FLOW [l/min] 380
RELIEF VALVE SETTING RANGE [bar] C (70-420)
STANDARD RELIEF SETTING [bar] 70
MAXIMUM FLUSHING FLOW [l/min] 80 C1 C2
Hydraulic circuit
MAXIMUM PRESSURE [bar] 350 C1 C2 C1
C1 C2 C2
BLOCK MATERIAL [] steel
DISTRIBUTOR FITTING [] D90

Relief cartridge typical pressure rise Oil supply flow (from C2 to C1)
drop [bar]

400
[bar]

30
400 400
30 12 30
300 24
Differential pressure

400 400 9 300


300 24
[bar]

24
18 M1
[bar]

200
[bar]
[bar][bar]

6 200
(C2-C1) pressure

300
[bar][bar]

300
200 18
18
[bar]

312
[bar]

100 100
200
200 12
100 12
0 6 V1 0 V2
0
100 6 0 40 80 120 160 0 100 200 300
0 100
0 100 200 300 400 06 [l/min]
[l/min]
Flow [l/min]
0 0 Flow
100 [l/min]
[l/min] 200 300 400 0 0 20 40 60 80 V1 F V2
0 0 100 200 300
[l/min]
400 0 0 20 40 60
[l/min]
80 V1 F V2
0 100 200 300
[l/min]
400 20
[l/min]
60 0 80 40 V1 F V2
[l/min] [l/min]
The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 205
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
ITALG R OU P M OTOR S R8 D S ERIES T E CH N ICAL CATALOGU E

VALVES - ORDERING CODE

---- --- - --- - --- D--

VALVE TYPE SIZE RATIO OVC REQUESTED RELIEF SETTING RELIEF REQUESTED DISTRIBUTOR
SETTING RANGE SETTING FITTING
(OPTIONAL) (OPTIONAL)

OVSA 160 1 2 3 --- D47

OVDA 160 1 2 3 --- D47

300 1 2 3 --- D75

480 1 2 3 --- D90

ORVSA 200 1 2 3 --- C --- D75

480 1 2 3 --- C --- D90

DRVSO 200 EP 1 2 3 --- C --- D75

RVDA 80 C --- D47

200 C --- D75

380 C --- D90

RVDAP 80 C --- D47

90 C --- D90

RVSAC 200 C --- D47

RVDAC 80 C --- D47

AP 40 D47

AC 80 D47

EXAMPLES:

OVDA 160 1 200 D47


AP 40 D47
ORVSA 480 3 250 C 200 D90
ORVSA 200 1 C D75
206 R8D rev.00 - Oct. 2018
CONTACT US

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the 207
right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.
R8D rev. 00
salvioli.it
Europe Asia Africa
Austria China Egypt
Belgium Hong Kong South Africa
Croatia India Tunisia
Czech Republic Indonesia
Cyprus Iran
Denmark Israel America
Faroe Islands Philippines Argentina
France Russia Brazil
Finland Belarus Canada
Germany Singapore Chile
Greece South Korea Mexico
Iceland Thailand Peru
Italy Taiwan USA
Netherland United Arab Emirates Colombia
Norway Vietnam
Poland
Portugal
Russia Oceania
Slovenia Australia
Spain New Zeland
Sweden
Switzerland
Turkey
Ukraina
United Kingdom

Italgroup S.r.l. - Via Pacinotti 20/22 - 41013 Gaggio di Piano - CASTELFRANCO EMILIA (MODENA) - Italy
208 R8D rev.00 - Oct. 2018
Tel. +39 059.924257 - Fax +39 059.920113 - Email: italgroup@italgroup.eu - www.italgroup.eu

You might also like