You are on page 1of 1

9 8 7 6 5

It´s simple,
4
safe and
3
organic 2 1

lichte Breite 1510

9 8 7 6
enteron 50
5 4 3 2

G
1

H
lichte Höhe 675

Length 1510
lichte Breite 1510 mm

TECHNICAL DATA F
G

Tank capacity. . . . . . . . . . 165 l in operation


600 mm

Weight of the plant . . . . . 50 kg


lichte Höhe 675

Total weight ready


Height

for operation . . . . . . . . . at least 215 kg E


Length . . . . . . . . . . . . . . . 1500 mm (clear length F 1510 mm)
Width . . . . . . . . . . . . . . . . 600 mm (clear width 610 mm)
Height . . . . . . . . . . . . . . . . 575 mm (clear height incl. hoses 600 mm)
Housing . . . . . . . . . . . . . . PEHD (tank)
PVC-U (valves
D
and pipes)
Approvals . . . . . . . . . . . . . IMO/MARPOL/MEPC E227(64),
Approval number 340.580
610610mm

Cleaning performance . . 50 l black water each day in normal operation


lichte Tiefe

Achieved BOD5 value . . . 10 mg/l (limit value 25 mg/l) in the outlet


Width

Bacteria in the outlet . . . 81 cfu/100 ml (limit


C
value 100 cfu/100 ml)
D
lichte Tiefe 610

200
CONTROL ELECTRONICS Allgemein- Maßstab: 1:5
C

ø6.4 tom logisch -


exploring the world in a better way
toleranzen
ISO 2768-cL

• fully encapsulated V4A installation housing with 2 m


DATUM Name
Gezeichnet 01.03.2017 Koke
enteron50 - lichte Einbaumaße
Kontrolliert 01.03.2017 Th. Logisch
Th. Logisch

connected control cable and 10 m cable for remote control


Norm 01.03.2017
leitender Konstrukteur Th. Logisch
A Zeichnung:
1/1
enteron50 Rev. 3.0 A1

• PLC control with possibility of remote maintenance and


Status Änderungen DATUM Name

9 8 7 6 5 4 2 3 1

software update by installation companies B


• display of operating and warning messages on a three-
200

250

coloured text display Allgemein- Maßstab: 1:5


tom logisch - toleranzen
exploring the world in a better way ISO 2768-cL
• length: 200 mm (260 mm incl. wall brackets)
DATUM
Gezeichnet 01.03.2017
Name
Koke
Kontrolliert 01.03.2017 Th. Logisch enteron50 - lichte Einbaumaße
M5
• width: 200 mm
Norm 01.03.2017 Th. Logisch

M5 leitender Konstrukteur Th. Logisch


Zeichnung:
A
1/1
enteron50 Rev. 3.0 A1

9 8 7 6 5 4 • height: Status Änderungen

3
DATUM

120 mm
Name

2 1

• housing: seawater resistant stainless steel 1.4404


160

CONTROL SOFTWARE REMOTE CONTROL


• fully automated PLC control of • length . . . . . . . . . . . . . . . . . 95 mm
all plant components
• width . . . . . . . . . . . . . . . . . . 95 mm
• operating system that cannot be
• installation depth . . . . . . . 50 mm
manipulated by the user
• required cut-out . . . . . . . . 65 x 65 mm
• housing . . . . . . . . . . . . . . . . anodised aluminium

tom logisch
®

Made in Germany © tomlogisch 2022

You might also like