You are on page 1of 1

METAL LATH BELOW OR WIDE SCREEN OVER

CORES TO SUPPORT GROUT FILL

EMBED ENT ENDS IN GROUT, 2 IN. (5.1MM) MIN.


OR USE CROSS PINS TO FORM ANCHORAGE

G F E D C B A GROUTED CORES

410 620 595 595 1030 1000 1000 1030 595 595 620 410
STEEL CONNECTORS AR 48 IN. (1.2M) O.C MAX.
VERTICALLY. 24 IN. (610MM.) MIN. LENGTH AND
MIN. SECTION 1/4 X 1 1/ IN. (6.4 X 38MM)

APEX LINE

SPOT DETAIL FOR


500

500
TOP OF PARAPET WALL
2 WALL TO WALL CONNECTION
850

A-03 SCALE: N/A

1150
TOP OF BEAM BLOCK
300

2ND. FLOR. FIN. CEILING LINE

FLOOR SYSTEM
WALL TECH PANELS

FINISH

2400
BASECOAT
2400

REINFORCING MESH
CONTINUOUS INSULATION
AIR/WATER BARRIER

7000MM
STEEL STUD
BEDROOM-2 WALK - IN CLOSET
BEDROOM FFL
SUBFLOOR
300

GRD. FLR. FIN. CEILING LINE

TRACK
SHEATHING
CAVITY INSULATION
WALL TECH PANELS

2700
2400

SPOT DETAIL FOR

3 WALL TO FLOOR CONNECTION


LIVING AREA KITCHEN
A-03 SCALE: N/A
LIVING/ DINING/ KITCHEN FFL
250

250
CARPORT FFL
TOP OF SIDEWALK
150

WALL TECH PANEL

120 DPP WIDE SALB WITH 105 MM SCREED WITH A 193 MESH

2T 10
1 SECTION
A-03 SCALE: 1:50MTRS.

A193 MESH

SPOT DETAIL FOR


4 WALL TO SLAB CONNECTION
A-03 SCALE: N/A

NAME OF SCHOOL: NAME OF PROFESSOR PLATE NO. 1 SUBJECT: NAME OF STUDENT: SHEET CONTENTS: SHEET NO.

SECTION

3
APPLICATION OF ALTERNATIVE WALL AND FLOOR SYSTEM SPOT DETAIL FOR:
UNIVERSITY OF NUEVA CACERES AR. JOEL B. OREA BUILDING TECHNOLOGY 05 BESADA, BRYAN I. WALL TO WALL
COLLEGE OF ENGINEERING AND ARCHITECTURE ON SIMPLE TOWNHOUSE
WALL TO FLOOR
WALL TO SLAB