LUBRICATION OIL LIST FOR SP-70 PLANT

Plant Model APPLICATION RECOMMENDED OIL QTY. 1 ST CHANGE HOURS 2 ND CHANGE SUBSEQUENT HOURS SPECIAL REMARKS
Breather plug & drain plug should be fix in proper position.
Extractor Belt SERVOMESH-320 10 150 500 Every 500 Hours Check the breather hole for proper ventilation.

It is necessary to stop the unit after 10-15 min. of running &


Skip hoist SERVOMESH-320 6 150 500 Every 500 Hours Check oil level. Fill if necessary to restore the max.

Each reduction will consume 8 Lt. oil. Please check the


Mixer Gbox SERVOMESH-150 17 200 500 Every 500 Hours braether for proper ventilation.
Gear unit model & Oil qty. are mentioned for std. supply
Screw Conveyor SERVOMESH- 220 /SERVOMESH - screw ie. 219 X 10 Mtrs. Given details may vary depend on
3 150 500 Every 500 Hours
GB 150 screw type. Oil qty. mentioned per unit.
Mentioned oil is specially recommended by ANEST IWATA
Air Compressor AIMAIR LUBE OIL 1.5 100 200 Every 200 Hours for their reciprocating air compressor.
SP-70 (SKIP)
Hydraulic Power Should be covered from dust & water.
SERVOSYSTEM HLP 68 15 100 250 Every 250 Hours
pack

FRL Unit ENGINE OIL 20W40 0.25 Periodically - As per low level mark on container Should be covered from dust.

Oil bath filter - Please check for level defines hole in oil container. Should
ENGINE OIL 20W40 0.25 Periodically - As per low level mark on container be covered from dust & water.
Compressor

Approx. 4-5 All bearing & blocks. Suitable for Multi purpose - Lithium
Bearing blocks AP-3 or MP-3 Grade grease Periodically - At regular intervals based on usage of machine. based Grease (AP or MP)
Kgs.

GREASE WITH CONSISTENCY Grease should be suitable for use under extreme pressure
Mixer shaft sealing 2 Kgs. Periodically - As per low level mark on container & machine usage. (EP). Eg. In HP brand LITHON EP1
CLASS NLGI 1 (EP1)