R.A. 545
AGREEMENT
GENERAL CONDITIONS
SPECIAL PROVISIONS CONTRACT DOCUMENTS
SPECIFICATIONS
DRAWINGS
full time construction inspector PROJECT REP.
offer of the bidder to perform the work PROPOSAL
cashier's check or surety bond with proposal submitted by the bidder
PROPOSAL BOND (5%)
that he will enter in the contract with the owner
approved form of the contractor and his surety to execute the work PERFORMANCE BOND (15%)
approved form of the contractor and his surety to pay all obligations PAYMENT BOND
guarantee to the quality of materials and equipment installed GUARANTEE BOND
contract between the owner and the contractor; including all supplemental
AGREEMENT
agreements thereto and all general and special provisions
invitaton issued to prospective bidders, giving information to the project INVITATION TO BID
additional information on contract documents BID BULLETIN
list of instructions stipulating the manner on how bids are to be prepared
INSTRUCTION TO BIDDERS
and conditions for the award of contract
graphical representation of the work involved in the project DRAWINGS
printed materials stipulating the procedural and adminitrative aspects of contract GENERAL CONDITIONS
instruction which may be issued prior to the bidding to supplement and or
SPECIAL PROVISIONS
modify drawings, specifications and general conditions
written or printed description of work to be done describing the qualities of
SPECIFICATIONS
materials and mode of construction
additional information which may be issued as an additon or ammendment
SUPPLEMENTARY SPECS.
to the provisions of specifications
outline specification enumerating the type or trade names of materials SCHED. OF MATERIALS
to be used AND FINISHES
listing of the different parts of the work indicating in each part the
BREAKDOWN OF WORK AND
corresponding value in materials and labor; including allowance for
CORRESPONDING VALUE
profit and overhead
information advice or notification pertinent to the project delivered. WRITTEN NOTICE
Page 1 of 7
PROFESSIONAL PRACTICE
SUITABILITY OF SITE
PHYSICAL SUITABILITY
SLOPE
AVAILABILITY OF BASIC NEEDS
CONFORMITY WITH ZONING ORDINANCES or LAND USE PLAN
Page 2 of 7
PROFESSIONAL PRACTICE
Page 3 of 7
PROFESSIONAL PRACTICE
rowhouse 50 sqm
duplex 150 sqm
single detached 100 sqm
FRONTAGE
Model A and B 10 m
Model C 8m
irregular lot 6m
rowhouse 4m
minimum width of alley after 250m block 4.00 m
maximim length of blocklength 400 m
Page 4 of 7
PROFESSIONAL PRACTICE
features that enable the disable person to make use of the primary function ACCESSIBLE
a small recess space in a room or a wall ALCOVE
Page 5 of 7
PROFESSIONAL PRACTICE
a break in the sidewalk or traffic island provided w/ an inclined surface to CURB CUT OUT
facilitate mobility of wheelchair
the degree of inclination of the sloped surface expressed in ratio GRADIENT OF RAMP
a sloped surface connecting two or more surface at different levels RAMP
a paved footwalk at the side of the street SIDEWALK
a strip fastened to the floor usually required to cover the joint where two
THRESHOLD
types of floor materials meet
an exterior passage for walking along WALKWAY
width of walkway to permit a person in wheelchair to traverse it w/ safety 1.20 m
maximum dimension of turn about spaces 1.50 m
maximum distance between restop 3.00 m
width of corridor for person to traverse w/ wheelchair 1.20 m
entrance depth w/ vestibule 3.00 m
structural opening of door entrances 1.00 m
clear opening of door entrances .80 m
minimum dimension of floor area of toilet 1.70 m x 1.80 m
minimum dimension of floor area of elevator 1.10 m x 1.40 m
minimum width of door elevator .80 m
centerline height of topmost buttons of elevator and floor switches .90 m - 1.20 m
maximum gradient of ramp 1:12
maximum length for 1:12 ramp 6.00 m
minimum length of landing for the 1:12 ramp 1.50 m
level area at the top and bottom of any ramp 1.80 m
handrail level on both edges .70 and .90
length of extension in a handrail from ramp .30 m
height of curbs in a ramp 50 mm
parking slot width 3.70 m
maximum height of tresholds 2.5 mm
provision of one fountain 1 for 2,000 sqm
height of the rim of the fountain from the floor 0.85 m
unobstructed clear space for public telephones 1.50 m x 1.50 m
height of dialling from floor of a telephone booth 1.10 m
clear opening of telephone booths .80 m
regular buses 5 seats
air conditioned bus 4 seats
passenger trains 6 seats
passenger airplanes 2 seats
4-50 seating capacity 2 seats
51-300 seating capacity 4 seats
301-500 seating capacity 6 seats
Page 6 of 7
PROFESSIONAL PRACTICE
RENOVATION
improve its aesthetic quality
a change in the use or occupancy of the building or any portion thereof
CONVERSION
which has different requirement
remedial work on any damaged or deterirated portion of a building to
REPAIR
restore its original condition
the transfer of any building structure portion thereof from its original
MOVING
location or position to another, either on the same lot or to either one
sytematic dismantling or destruction of a building in whole or part DEMOLITION
a secondary building located within the same premises the use of which is
ANCILLARY BUILDING
incidental to that of the main building
Page 7 of 7