You are on page 1of 50

Solar PV Module Testing including Information

about Data Sheet of Module

RAMCHANDER NIRUDI
Consultant (Solar PV Projects),
Associate Professor, EEED-BVRIT,
& Guest Faculty at RECIPMT,ESCI, CPTI (TSSPDCL), CTI (TSTRANCO), CBIP
Solar PV Modules
Different Solar PV Technologies Installed at NISE
3
Data sheet interpretation of SPV modules(Multi/Mono)
World-class products, Made in India

4
Data sheet interpretation of SPV modules
(180 Half Cut Mono Crystalline PERC Cells.)
World-class products, Made in India

5
Data sheet interpretation of SPV modules
(180 Half Cut Mono Crystalline PERC Cells.)
World-class products, Made in India

6
Tests on Panel
• Conceptual Stage

• Manufacturing Phase

• Transportation & Installation Phase

• Commissioning Phase

• Operational / In service Phase


Tests on Panel
• Insulation Test • Mechanical Load Test
• Measurement of Temperature • Hail Test
coefficients • Bypass Diode Thermal Test
• Measurement of NOCT • Coating Thickness Test
• Performance at STC & NOCT • Bonding Path Resistance Test
• Performance at Low Irradiation • Wet Insulation Resistance Test
• Outdoor exposure Test • Terminal Torque Test
• Hotspot Endurance Test • Impact Test
• UV preconditioning • Water Spray Test
• Thermal Cycling Test • Accelerated Ageing Test
• Humidity freeze Test • Humidity Test
• Damp Heat Test • Corrosive Atmosphere Test
• Robustness of Termination Test • PID Test
• Wet Leakage Current test • LID Test
• UV/Visible Spectrometer
I-V Curve Tracer
 The Daystar DS-100C I-V curve tracer is a portable self-contained unit
for testing installed photovoltaic systems. It weighs 13 kg and is
packaged in a non-metallic case 44 x 35 x 20 cm.
 The DS-100C uses a capacitive load to vary the impedance connected
to the output terminals of the PV array under test. The voltage and
current are sampled as the capacitors in the DS-100C are charged. This
data set is transferred to the control computer for display, analysis,
and storage using the powerful Windows-based IVPC software.
 The displayed I-V curve includes values of:
• Open Circuit Voltage, Voc
• Short Circuit Current, Isc
• Peak Power
• Voltage at Peak Power, Vpk
• Current at Peak Power, Ipk
• Fill Factor
10-Mar-22 33
Operation and Maintenance

• Regular cleaning of the modules


• Online monitoring through Refulog
mobile App
• Physical inspection at regular
intervals

10-Mar-22 53
Q. How frequently should clean the solar panels
as per your knowledge.

a) Daily once
b) Weekly once
c) Monthly once
d) It depends on the site location
10-Mar-22 55
10-Mar-22 56
“Our development of Photovoltaic's is something that I feel is a
mission, not just technical or scientific research. I believe it is the
only energy source that can save mankind in the 21st century”
Dr. Yoshihiro Hamakawa , Osaka University

Thank you
By
RAMCHANDER NIRUDI
Project Engineer (Solar Projects)
Associate Professor, EEED-BVRIT.
Email: ramchander.nirudi@gmail.com
Mobile: 9247798832

10-Mar-22 58

You might also like