You are on page 1of 32

ASHRAE 90.

1–2019
nLight® Applications Guide

www.nlightcontrols.com
2 Intro

nLight Lighting Controls Platform

It’s not just smarter. It’s easier.

nLight is a sensor-based, digital lighting


controls solution that offers wired and wireless
lighting controls that easily connect luminaires,
sensors, and other control devices to create a
digital network. The nLight platform of products
enables ease in specification, installation, and
ownership, making it the go-to digital lighting
controls platform for specifiers, contractors, and
building owners.

www.nlightcontrols.com • 800-535-2465
Table of Contents 1

TABLE OF CONTENTS

04 Code Requirements for Common Building Spaces


05 How to Use This Guide
06 Enclosed Office Solutions
08 Open Plan Office Solutions
10 Conference Room Solutions
12 Classroom Solutions
14 Lobby Solutions
16 Corridor Solutions
18 Restroom Solutions
20 Stairwell Solutions
21 Gymnasium Solutions
22 Warehouse/Storage Solutions
23 Parking Area (Garage), Interior
24 Exterior Lighting
25 nLight Hybrid Networked Lighting Control
26 Requirements Overview
28 nLight Enabled Luminaires
29 Specification Tools

ASHRAE 90.1–2019: nLight Applications Guide


2

www.nlightcontrols.com • 800-535-2465
About 3

ABOUT

About ASHRAE 90.1


ASHRAE 90.1 is an energy code designed to reduce
energy consumption. The ASHRAE 90.1–2019 energy
code has specific requirements for lighting controls.
The use of advanced lighting controls to synchronize
light levels with daylight, occupancy, and multi-level
control capability are required in order to be compliant.

About This Guide


Acuity Brands® offers the nLight® ASHRAE 90.1–2019
Applications Guide as a reference of typical nLight
layouts that help make code compliance quicker and
easier. The Acuity Brands Design Services Team is also
available to support engineers and contractors
with detailed design, submittal, and installation.
For additional information, please contact your
Acuity Brands Sales Representative.

About nLight
A Single Lighting Controls Platform for Indoor &
Outdoor Spaces
nLight® is a distributed intelligence, lighting control
platform that offers wired and wireless control products.
Luminaires, sensors, switches, and other control devices
create one solution that aids in code compliance,
energy reduction, and advanced network capabilities.
Ideal for any application, small to large, indoor to
outdoor, nLight offers lighting controls that scale from
one room to an entire floor, from one floor to an entire
building, and from one building to an entire campus.

ASHRAE 90.1–2019: nLight Applications Guide


4 Code Requirements for Common Building Spaces

The chart below is an overview of the Code Requirements for Common Building Spaces. Please use this information as a guide.
For specific ASHRAE code requirements please refer to the ASHRAE 90.1–2019 code.

Space Type

Control Code Code Conference,


Open Classroom,
Requirement* Provision Summary* Enclosed Meeting, Gymnasium/
Plan Lecture Hall, Lobby Corridor Restroom Stairwell
Office Multipurpose Fitness Center
Office Training Room
Room
There shall be one or more readily
accessible manual lighting controls in
Local (i.e., Switch) the space that controls all lighting in
9.4.1.1[a]
Control the space.
Note: Remote locations permitted for
reasons of safety or security.

None of the lighting in the space shall


Manual ON 9.4.1.1[b]
be automatically turned on.

(or) (or) (or) (or) (or)

The general lighting shall be allowed


Partial Automatic
9.4.1.1[c] to be turned on automatically to 50%
ON
of the lighting power.
On-Off Control

Automatically controlled spaces are


Full Automatic ON 9.4.1.1
allowed to turn on to full.

The general lighting power shall be


Automatic automatically reduced by at least 50%
Partial OFF Via 9.4.1.1[g] within 20 minutes of all occupants
Occupancy Sensor leaving the space.
Note: Full Off also complies.

Automatic Full All lighting shall be automatically shut


OFF Via 9.4.1.1[h] off within 20 minutes of all occupants
Occupancy Sensor leaving the space.
(or) (or) (or) (or) (or)
All lighting shall be automatically shut
off during periods when the space is
Scheduled Shut-
scheduled to be unoccupied using a
off & Off During 9.4.1.1[i]
time-of-day operated control.
Non-Business 9.4.1.1[j]
Note: A signal from another automatic
Hours
control device or alarm/security
system complies.

Controlled lighting shall have at least


Bi-Level one control step between 30% and
9.4.1.1[d]
Lighting Control 70%, or continuous dimming,
Light Level Control

in additional to full on and full off.

If the general lighting load is 150W or


Automatic
greater in the primary sidelighted or
Daylight
toplighted areas, or 300W or greater
Responsive 9.4.1.1[e]
in the primary & secondary sidelighted
Controls for 9.4.1.1[f]
areas, the general lighting in these areas
Sidelighting/
shall be controlled by multi-step or
Toplighting
continuous dimming photocontrols.

Lighting power of each luminaire shall


Parking Garage
be automatically reduced by a minimum
Lighting Power 9.4.1.2[b]
of 30% when there is no activity detected
Setback
within a lighting zone for 20 minutes.
Additional Controls

50% of all receptacles, and 25%


of branch circuit feeders installed
Automatic for modular furniture, shall be
Receptacle automatically turned off by an occupant  
8.4.2
(i.e. Plug Load sensor within 20 minutes of all
Control) occupants leaving the space.
Note: A time-of-day schedule or a signal from another au-
tomatic control device or alarm/security system complies.
Exterior Control

Exterior 9.4.1.4[a] Daylight shutoff


9.4.1.4[b] Facade and Landscape
Lighting 9.4.1.4
lighting shutoff
Controls 9.4.1.4[c] Lighting setback

  * Note: This summary is for general information purposes only and is provided without any warranty as to accuracy, completeness, or otherwise. The user should read the applicable code sections for more complete and detailed descriptions of code requirements
and exceptions and should consult with a professional engineering or other competent advisor before making any decision or taking any action based on this summary.

www.nlightcontrols.com • 800-535-2465
How to Use This Guide 5

For each space type there will be a wired solution Room description Room layout diagram with
Parking on the left and wireless solution on the right. controls, fixtures, and wiring
Warehouse/ Exterior
Area (Garage),
Storage Area Lighting
Interior

6 ENCLOSED OFFICE: < 250 sq. ft., Windows, nLight Enabled Fixtures

Wired Wireless
Wire type
legend
nWSXA PDT LV DX rPODBA DX
nPP20 PL rPP20 24V

(or)

CAT-5e Cable

Line Voltage Line Voltage


Wires Wires

Line Power Line Power


Feed Feed

Bill of Materials Bill of Materials


Symbol Qty Product # Description Symbol Qty Product # Description
Required list of
2 See Note nLight Wired Enabled Troffer
DZ 1
2 See Note
nLight AIR Enabled Troffer with
Sensor Option devices in order
1 nWSXA PDT LV DX
Wall Switch Occupancy Sensor
with On/Off, Raise/Lower 1 rPODBA DX G2
Battery Powered, On/Off, Raise/
Lower WallPod
to implement
1 nPP20 PL Plug Load Relay Pack 1 rPP20 24V EFP G2 Plug Load Relay Pack
room layout
design above
rPP20 24V
rPODB 4S DX rPODB DX

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:


Light Fixtures: Occupancy Control: Daylight Control: Manual Control: ¡ Room can be connected to nLight backbone to
¡ All fixtures are dimmable ¡ Fixtures must be turned ¡ Not required for offices ¡ On/off & raise/lower enable network control or time schedules
¡ All fixtures can be on manually (or optionally without windows or that control of fixtures ¡ HVAC control available through system-wide
controlled together can be configured to have loads <150W in BACnet® interface option on the
or independently come on automatically sidelit zones ECLYPSE® controller
to 50%) ¡ Wireless fixture embedded control and
(or) ¡ Maximum level can
be task tuned to ¡ Plug-load turns on
automatically
occupancy/daylighting sensor options available,
please see the fixture specification sheet
any percentage via
programming ¡ Fixtures and plug-load ¡ For emergency lighting control use a power
turn off automatically pack with ER/EM option or nLight Enabled
when room becomes Fixture with emergency option
vacant

Note: Contact your local lighting agent for more information on nLight enabled fixtures.

www.acuitybrands.com/nLight • 800-535-2465

Operational details describe the functionality Additional options that add control
provided by the equipment specified in the solution capacity beyond code requirements

ASHRAE 90.1–2019: nLight Applications Guide


6 ENCLOSED OFFICE: < 250 sq. ft., Windows, nLight Enabled Fixtures

Wired Wireless

nWSXA PDT LV DX rPODBA DX


nPP20 PL rPP20 24V

CAT-5e Cable

Line Voltage Line Voltage


Wires Wires

Line Power Line Power


Feed Feed

Bill of Materials Bill of Materials


Symbol Qty Product # Description Symbol Qty Product # Description

2 See Note nLight Wired Enabled Troffer nLight AIR Enabled Troffer with
2 See Note
DZ 1 Sensor Option
Wall Switch Occupancy Sensor Battery Powered, On/Off, Raise/
1 nWSXA PDT LV DX 1 rPODBA DX G2
with On/Off, Raise/Lower Lower WallPod

1 nPP20 PL Plug Load Relay Pack 1 rPP20 24V EFP G2 Plug Load Relay Pack

rPP20 24V
rPODB 4S DX rPODB DX

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:


Light Fixtures: Occupancy Control: Daylight Control: Manual Control: ¡ Room can be connected to nLight backbone to
¡ All fixtures are dimmable ¡ Fixtures must be turned ¡ Not required for offices ¡ On/off & raise/lower enable network control or time schedules
¡ All fixtures can be on manually (or optionally without windows or that control of fixtures ¡ HVAC control available through system-
controlled together can be configured to have loads <150W in wide BACnet interface option on the nLight
or independently come on automatically sidelit zones ECLPYSE™ controller
to 50%) ¡ Wireless fixture embedded control and
¡ Maximum level can
be task tuned to ¡ Plug-load turns on occupancy/daylighting sensor options available,
any percentage via automatically please see the fixture specification sheet
programming ¡ Fixtures and plug-load ¡ For emergency lighting control use a power
turn off automatically pack with ER/EM option or nLight Enabled
when room becomes Fixture with emergency option
vacant

Note: Contact your local lighting agent for more information on nLight enabled fixtures.

www.nlightcontrols.com • 800-535-2465
ENCLOSED OFFICE: < 250 sq. ft., Windows, 0-10V Dimming Fixtures 7

Wired Wireless

nWSXA PDT LV DX rPODBA DX


nPP20 PL rPP20 24V
rCMSB PDT 7

rPP20 D 24V
nPP16 D

CAT-5e Cable

Line Voltage Line Voltage


Wires Wires

0-10V Wires 0-10V Wires

Line Power Line Power


Feed Feed

Bill of Materials Bill of Materials


Symbol Qty Product # Description Symbol Qty Product # Description

Relay Pack with 0-10V rPP20 D 24V Relay Pack with 0-10V
1 nPP16 D EFP 1
Dimming Output EFP G2 Dimming Output

Wall Switch Occupancy Sensor Battery Powered, On/Off, Raise/


1 nWSXA PDT LV DX 1 rPODBA DX G2
with On/Off, Raise/Lower Lower WallPod

1 nPP20 PL Plug Load Relay Pack Battery Powered Occupancy and


1 rCMSB PDT 7 G2
Daylight Sensor

1 rPP20 24V EFP G2 Plug Load Relay Pack

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:


Light Fixtures: Occupancy Control: Daylight Control: Manual Control: ¡ Room can be connected to nLight backbone to
¡ All fixtures are dimmable ¡ Fixtures must be turned ¡ Not required for offices ¡ On/off & raise/lower enable network control or time schedules
¡ All fixtures are controlled on manually (or optionally without windows or that control of fixtures ¡ HVAC control available through system-
together can be configured to have loads <150W in wide BACnet interface option on the nLight
come on automatically sidelit zone ECLPYSE™ controller
¡ Maximum level can
to 50%) ¡ For emergency lighting control use a power
be task tuned to
any percentage via ¡ Plug-load turns on pack with ER/EM option or nLight Enabled
programming automatically Fixture with emergency option
¡ Fixtures and plug-load
turn off automatically
when room becomes
vacant

ASHRAE 90.1–2019: nLight Applications Guide


8 OPEN PLAN OFFICE: nLight Enabled Fixtures

Wired Wireless

nPODMA DX rPODBA DX 1
1

DZ
DZ
EM
EM

nCM PDT 9 nCM PDT 9

nCM ADCX

CAT-5e Cable
1 1

Line Voltage EM Power


EM
Wires EM
Feed
nCM PDT 9
nCM PDT 9

Line Power Line Voltage


Feed Wires

Line Power
EM Power Feed
nPP20 PL
rPP20 24V
rPODBA DX
Feed
nPODMA DX

1 Fixture(s) assumed to include power interruption detection emergency option. 1 Fixture(s) assumed to include power interruption detection emergency option.
For battery backup option, no dedicated EM circuit necessary. For battery backup option, no dedicated EM circuit necessary.

Bill of Materials Bill of Materials


Symbol Qty Product # Description Symbol Qty Product # Description

14 See Note nLight Wired Enabled Troffer nLight AIR Enabled Troffer
14 See Note
with Sensor Option
nLight Wired Enabled Troffer nLight AIR Enabled Troffer
2 See Note 2 See Note
with Battery Option with Sensor and EM Option

2 nPODMA DX On/Off, Raise/Lower WallPod Battery Powered, On/Off,


2 rPODBA DX G2
Raise/Lower WallPod
4 nCM PDT 9 RJB Occupancy Sensor
1 rPP20 24V EFP G2 Plug Load Relay Pack

1 nCM ADCX RJB Daylight Sensor

1 nPP20 PL Plug Load Relay Pack

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Daylight Control: Manual Control: ¡ Room can be connected to nLight backbone
¡ All fixtures are dimmable ¡ Fixtures must be turned ¡ Smooth continuous ¡ On/off & raise/lower to enable network control or time schedules
¡ All fixtures are controlled on manually (or optionally dimming control of fixtures ¡ HVAC control available through system-wide
together or independently can be configured to ¡ Custom grouping of BACnet interface option on the nLight
come on automatically fixtures into separate ECLPYSE™ controller
¡ Maximum level can
to 50%) daylight zones (max. ¡ Wireless fixture embedded control and occupancy/
be task tuned to
any percentage via ¡ Plug-load turns on number zones = number daylighting sensor options available, please see
programming automatically of fixtures) the fixture specification sheet
¡ Fixtures and plug-load ¡ Not required for offices ¡ For emergency lighting control use a power pack
turn off automatically without windows or that with ER/EM option or nLight Enabled Fixture with
when room becomes have loads <150W in emergency option
vacant sidelit zones

Note: Contact your local lighting agent for more information on nLight enabled fixtures.

www.nlightcontrols.com • 800-535-2465
OPEN PLAN OFFICE: 0-10V Dimming Fixtures 9

Wired Wireless

nPP16 D ER nPP20 PL rPP20 D 24V EM rPP20 24V

DZ
nPODMA DX

DZ
rPODBA DX

EM EM

nCM PDT 9 nCM PDT 9 rCMSB PDT 7 rCMSB PDT 7

Low Voltage
nCM ADCX CAT-5e Cable rCMSB PDT 7
Wires

Line Voltage Line Voltage


Wires Wires
EM EM

nCM PDT 9
nCM PDT 9
Line Power rCMSB PDT 7
rCMSB PDT 7
Line Power
Feed Feed

0-10V Wires 0-10V Wires

nPP16 D nPP16 D
nPODMA DX
nPP16 D nPP16 D
EM Power Feed rPP20 D 24V rPP20 D 24V
rPODBA DX
rPP20 D 24V rPP20 D 24V
EM Power Feed

Bill of Materials Bill of Materials


Symbol Qty Product # Description Symbol Qty Product # Description

Relay Pack with 0-10V rPP20 D 24V EFP Relay Pack with 0-10V Dimming
4 nPP16 D EFP 4
Dimming Output G2 Output

Emergency Relay Pack with rPP20 D 24V EM Emergency Relay Pack with
1 nPP16 D ER EFP 1
0-10V Dimming Output EFP G2 0-10V Dimming Output

Battery Powered, On/Off,


2 nPODMA DX On/Off, Raise/Lower WallPod 2 rPODBA DX G2
Raise/Lower WallPod

4 nCM PDT 9 RJB Occupancy Sensor Battery Powered Occupancy


5 rCMSB PDT 7 G2
and Daylight Sensor
1 nCM ADCX RJB Daylight Sensor
1 rPP20 24V EFP G2 Plug Load Relay Pack
1 nPP20 PL Plug Load Relay Pack

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Daylight Control: Manual Control: ¡ Room can be connected to nLight backbone
¡ All fixtures are dimmable
¡ Fixtures must be turned ¡ Smooth continuous ¡ On/off & raise/lower to enable network control or time schedules
¡ Each row controlled on manually (or optionally dimming control of fixtures ¡ HVAC control available through system-wide
independently can be configured to ¡ Daylight zones defined BACnet interface option on the nLight
come on automatically by rows ECLPYSE™ controller
¡ Maximum level can be
to 50%) ¡ For emergency lighting control use a power pack
task tuned to any per- ¡ Not required for offices
centage via programming ¡ Plug-load turns on without windows or that with ER/EM option or nLight Enabled Fixture with
automatically have loads <150W in emergency option
¡ Fixtures and plug-load sidelit zones
turn off automatically
when room becomes
vacant

ASHRAE 90.1–2019: nLight Applications Guide


10 CONFERENCE ROOM with nLight Enabled Fixtures

Wired Wireless

nPODMA 2P DX rPODBA 2P DX
nPP20 PL rPP20 24V
nCM PDT 9

nCM ADCX

CAT-5e Cable Line Voltage Wires Line Power Feed Line Voltage Wires Line Power Feed

Bill of Materials rPP20 24V


Bill of Materials rPODB 2P DX

Symbol Qty Product # Description Symbol Qty Product # Description


nLight Wired Enabled nLight AIR Enabled Linear
1 See Note 1 See Note
Linear Fixture Fixture with Sensor Option
nLight Wired Enabled nLight AIR Enabled
6 See Note 6 See Note
Downlight Fixture Downlight Fixture
nPODM 2P DX nPODM 2P DX

2-Pole, On/Off, Raise/ Battery Powered, 2-Pole, On/


nPP20 PL
nCM PDT 9 nCM PDT 9

1 nPODMA 2P DX 1 rPODBA 2P DX G2
Lower WallPod Off, Raise/ Lower WallPod

1 nCM PDT 9 RJB Occupancy Sensor 1 rPP20 24V EFP G2 Plug Load Relay Pack

1 nCM ADCX RJB Daylight Sensor

1 nPP20 PL Plug Load Relay Pack

nCM ADCX nCM ADCX

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Daylight Control: Manual Control: ¡ Room can be connected to nLight backbone
¡ All fixtures are dimmable ¡ Fixtures must be ¡ Smooth continuous ¡ On/off & raise lower to enable network control or time schedules
¡ Maximum level can turned on manually dimming control of two zones ¡ HVAC control available through system-wide
be task tuned to (or optionally can be ¡ Custom grouping of of fixtures BACnet interface option on the nLight
any percentage via configured to come on fixtures into separate ECLPYSE™ controller
programming automatically to 50%) daylight zones (max ¡ Wireless fixture embedded control and occupancy/
¡ A/V zone can be ¡ Plug-load turns on number zones = number daylighting sensor options available, please see the
programmed to control automatically of fixtures) fixture specification sheet
two fixtures in front of ¡ Fixtures and plug-load ¡ Not required for areas ¡ For emergency lighting control use a power pack
the whiteboard turn off automatically without windows or that with ER/EM option or nLight Enabled Fixture with
when room becomes have loads <150w in emergency option
vacant sidelit zones

Note: Contact your local lighting agent for more information on nLight enabled fixtures.

www.nlightcontrols.com • 800-535-2465
CONFERENCE ROOM with 0-10V Dimming Fixtures 11

Wired Wireless

nPODMA 2P DX rPODBA 2P DX
nPP20 PL rPP20 24V
nCM PDT 9 rCMSB PDT 7

nPP16 D

rPP20 D 24V

nPP16 D

rPP20 D 24V

nCM ADCX

CAT-5e Cable Line Voltage Wires Line Power Feed 0-10V Wires Low Voltage Wires Line Voltage Wires Line Power Feed 0-10V Wires

Bill of Materials Bill of Materials


Symbol Qty Product # Description Symbol Qty Product # Description

Relay Pack with 0-10V Relay Pack with 0-10V


2 nPP16 D EFP 2 rPP20 D 24V EFP G2
Dimming Output Dimming Output
nPODM 2P DX nPODM 2P DX

2-Pole, On/Off, Raise/ Battery Powered, 2-Pole, On/


nPP20 PL
nCM PDT 9 nCM PDT 9

1 nPODMA 2P DX 1 rPODBA 2P DX G2
Lower WallPod Off, Raise/ Lower WallPod
Battery Powered Occupancy
1 nCM PDT 9 RJB Occupancy Sensor 1 rCMSB PDT 7 G2
and Daylight Sensor

1 nCM ADCX RJB Daylight Sensor 1 rPP20 24V EFP G2 Plug Load Relay Pack

1 nPP20 PL Plug Load Relay Pack

nCM ADCX nCM ADCX

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Daylight Control: Manual Control: ¡ Room can be connected to nLight backbone
¡ All fixtures are dimmable ¡ Fixtures must be ¡ Smooth continuous ¡ On/off & raise lower to enable network control or time schedules
¡ Maximum level can turned on manually dimming control of two zones ¡ HVAC control available through system-wide
be task tuned to (or optionally can be ¡ Daylight zones defined of fixtures BACnet interface option on the nLight
any percentage via configured to come on by rows ECLPYSE™ controller
programming automatically to 50%) ¡ For emergency lighting control use a power pack
¡ Not required for areas
¡ Plug-load turns on without windows or that with ER/EM option or nLight Enabled Fixture with
automatically have loads <150W in emergency option
¡ Fixtures and plug-load sidelit zones
turn off automatically
when room becomes
vacant

ASHRAE 90.1–2019: nLight Applications Guide


12 CLASSROOM with nLight Enabled Fixtures

Wired Wireless

nCM ADCX

DZ DZ

nPODMA 4S DX

rPP20 24V
nWV PDT 16 nPP20 PL
rPODBA 4S DX rPODBA DX

CAT-5e Cable Line Voltage Wires Line Power Feed Line Voltage Wires Line Power Feed

Bill of Materials Bill of Materials


Symbol Qty Product # Description Symbol Qty Product # Description

nLight AIR Enabled Troffer


9 See Note nLight Wired Enabled Troffer 9 See Note
DZ 1 with Sensor Option
Battery Powered, On/Off,
1 nPODMA DX On/Off, Raise/Lower WallPod 1 rPODBA DX G2
Raise/Lower WallPod
Teacher Station — Battery
Dual Technology Wide View 1 rPODBA 4S DX G2 Powered 4 Scene Control with
1 nWV PDT 16
Occupancy Sensor Master On/Off & Raise/Lower
Teacher Station — 4 Scene
1 nPODMA 4S DX Control with Master On/Off & 1 rPP20 24V EFP G2 Plug Load Relay Pack
Raise/Lower
rPODB 4S DX
rPP20 24V
rPODB DX

1 nCM ADCX RJB Daylight Sensor

1 nPP20 PL Plug Load Relay Pack

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Daylight Control: Manual Control: ¡ Room can be connected to nLight backbone
¡ All fixtures are dimmable ¡ Fixtures must be ¡ Smooth continuous ¡ On/off & raise/lower to enable network control or time schedules
¡ All fixtures are turned on manually dimming control of ¡ HVAC control available through system-wide BACnet
controlled together or (or optionally can be ¡ Custom grouping of entire room interface option on the nLight ECLPYSE™ controller
independently configured to some on fixtures into separate ¡ Teacher station with 4 ¡ Wireless fixture embedded control and occupancy/
automatically to 50%) daylight zones (max preset scenes daylighting sensor options available, please see the
¡ Maximum level can
be task tuned to ¡ Plug-load turns on number zones = number fixture specification sheet
any percentage via automatically of fixtures) ¡ For emergency lighting control use a power pack
programming ¡ Fixtures and plug-load ¡ Not required for areas with ER/EM option or nLight Enabled Fixture with
turn off automatically without windows or that emergency option
when room becomes have loads <150W in
vacant sidelit zones

Note: Contact your local lighting agent for more information on nLight enabled fixtures.

www.nlightcontrols.com • 800-535-2465
CLASSROOM with 0-10V Dimming Fixtures 13

Wired Wireless

nCM ADCX
rCMSB PDT 7
DZ
DZ

nPP16 D rPP20 D 24V

nPP16 D rPP20 D 24V

rCMSB PDT 7

nPP16 D rPP20 D 24V

nPODMA 4S DX

rPP20 24V
nWV PDT 16 nPP20 PL
rPODBA 4S DX rPODBA DX

CAT-5e Cable Line Voltage Wires Line Power Feed 0-10V Wires Low Voltage Wires Line Voltage Wires Line Power Feed 0-10V Wires

Bill of Materials Bill of Materials


Symbol Qty Product # Description Symbol Qty Product # Description

Relay Module with 0-10V Relay Pack with 0-10V


3 nPP16 D EFP 3 rPP20 D 24V EFP G2
Dimming Output Dimming Output
Battery Powered, On/Off,
1 nPODMA DX On/Off, Raise/Lower WallPod 1 rPODBA DX G2
Raise/Lower WallPod

Dual Technology Wide View Battery Powered Occupancy


1 nWV PDT 16 2 rCMSB PDT 7 G2
Occupancy Sensor and Daylight Sensor
Teacher Station — Battery
Teacher Station — 4 Scene
1 rPODBA 4S DX G2 Powered 4 Scene Control with
1 nPODMA 4S DX Control with Master On/Off &
Master On/Off & Raise/Lower
Raise/Lower
1 rPP20 24V EFP G2 Plug Load Relay Pack
1 nCM ADCX RJB Daylight Sensor

1 nPP20 PL Plug Load Relay Pack

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Daylight Control: Manual Control: ¡ Room can be connected to nLight backbone
¡ All fixtures are dimmable¡ Fixtures must be ¡ Smooth continuous ¡ Master on/off & raise/ to enable network control or time schedules
¡ Each row can be turned on manually dimming lower control of ¡ HVAC control available through system-wide
controlled independently (or optionally can be ¡ Daylight zones defined entire room BACnet interface option on the nLight
configured to come on by rows ¡ Teacher station with 4 ECLPYSE™ controller
¡ Maximum level can
automatically to 50%) preset scenes ¡ For emergency lighting control use a power pack
be task tuned to ¡ Not required for areas
any percentage via ¡ Plug-load turns on without windows or that with ER/EM option or nLight Enabled Fixture with
programming automatically have loads <150W in emergency option
¡ Fixtures and plug-load sidelit zones
turn off automatically
when room becomes
vacant

ASHRAE 90.1–2019: nLight Applications Guide


14 LOBBY with nLight Enabled Fixtures

Wired Wireless

DZ DZ
nCM PDT 9 ADCX

nPODMA DX rPODBA DX

CAT-5e Cable Line Voltage Wires Line Power Feed Line Voltage Wires Line Power Feed

Bill of Materials Bill of Materials


Symbol Qty Product # Description Symbol Qty Product # Description
nLight Wired DZ
4 See Notes 4 See Notes nLight AIR Enabled Downlight
Enabled Downlight

1 See Notes nLight Wired Enabled Troffer nLight AIR Enabled Troffer
1 See Notes
with Sensor Option

1 nPODMA DX On/Off, Raise/Lower WallPod Battery Powered, On/Off,


1 rPODBA DX G2
nPODM DX

Raise/Lower WallPod
nCM PDT 9 Occupancy and
1
ADCX RJB Daylight Sensor

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Daylight Control: Manual Control: ¡ Room can be connected to nLight backbone
¡ All fixtures are dimmable ¡ Fixtures automatically ¡ Smooth continuous ¡ On/off & raise/lower to enable network control or time schedules
¡ All fixtures are go to full bright when dimming control of fixtures ¡ HVAC control available through system-wide BACnet
controlled together or occupied ¡ Custom grouping of interface option on the nLight ECLPYSE™ controller
independently ¡ Fixtures automatically fixtures into separate ¡ Wireless fixture embedded control and occupancy/
¡ Maximum level can be turn off when room daylight zones (max daylighting sensor options available, please see the
task tuned to becomes vacant number zones = number fixture specification sheet
any percentage of fixtures) ¡ For emergency lighting control use a power pack
via programming ¡ Not required for areas with ER/EM option or nLight Enabled Fixture with
without windows or that emergency option
have loads <150W in
sidelit zones

Note: Contact your local lighting agent for more information on nLight enabled fixtures.

www.nlightcontrols.com • 800-535-2465
LOBBY with 0-10V Dimming Fixtures 15

Wired Wireless

nCM PDT 9 ADCX


DZ rCMSB PDT 7
DZ
nPP16 D rPP20 D 24V

nPP16 D rPP20 D 24V

nPODMA DX rPODBA DX

CAT-5e Cable Line Voltage Wires Line Power Feed 0-10V Wires Low Voltage Wires Line Voltage Wires Line Power Feed 0-10V Wires

Bill of Materials Bill of Materials


Symbol Qty Product # Description Symbol Qty Product # Description

Relay Pack with 0-10V Relay Pack with 0-10V


2 nPP16 D EFP 2 rPP20 D 24V EFP G2
Dimming Output Dimming Output
Battery Powered, On/Off,
1 nPODMA DX On/Off, Raise/Lower WallPod 1 rPODBA DX G2
Raise/Lower WallPod
nCM PDT 9 Occupancy and Battery Powered Occupancy
1 1 rCMSB PDT 7 G2
ADCX RJB Daylight Sensor and Daylight Sensor

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Daylight Control: Manual Control: ¡ Room can be connected to nLight backbone
¡ All fixtures are dimmable ¡ Fixtures automatically ¡ Smooth continuous ¡ On/off & raise/lower to enable network control or time schedules
¡ Maximum level can be go to full bright when dimming control of fixtures ¡ HVAC control available through system-wide BACnet
task tuned to occupied ¡ Daylight zones defined interface option on the nLight ECLPYSE™ controller
any percentage ¡ Fixtures automatically by relay module wiring ¡ For emergency lighting control use a power pack
via programming turn off when room ¡ Not required for areas with ER/EM option or nLight Enabled Fixture with
becomes vacant without windows or that emergency option
have loads <150W in
sidelit zones

ASHRAE 90.1–2019: nLight Applications Guide


16 CORRIDOR with nLight Enabled Fixtures

Wired Wireless

nCM 10 nCM 10

nPODMA EM nPODMA rPODBA EM rPODBA

1 1

nCM 10

CAT-5e Cable
Line Voltage
Line Voltage
1

Wires
EM

Wires

EM
1
Line Power
Line Power Feed
Feed

EM Power
nCM 10 EM Power Feed Feed
rPODBA
nPODMA

1 Fixture(s) assumed to include power interruption detection emergency option.


1 Some nLight enabled EM fixtures require a normal sense line connection. For battery backup option, no dedicated EM circuit necessary.
Some nLight enabled EM fixtures require a normal sense line connection. Wiring
Wiring shown assumes battery backup emergency option. See fixture spec sheets for details.
Fixture(s) assumed to include power interruption detection emergency option.
shown assumes battery backup emergency option. See fixture spec sheets for details. For battery backup option, no dedicated EM circuit necessary.

Bill of Materials Bill of Materials


Symbol Qty Product # Description Symbol Qty Product # Description

nLight Wired Enabled Troffer nLight AIR Enabled Troffer


7 See Note 7 See Note
with Sensor Option with Sensor Option

nLight Wired Enabled Troffer nLight AIR Enabled Troffer


2 See Note 2 See Note
with Battery Option with Sensor and EM Option

Battery Powered, On/Off


3 nPODMA On/Off WallPod 3 rPODBA G2
WallPod

4 nCM 10 RJB Occupancy Sensor

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Daylight Control: Manual Control: ¡ Room can be connected to nLight backbone
¡ All fixtures are dimmable ¡ Fixtures automatically ¡ Not required for areas ¡ On/off control to enable network control or time schedules
¡ All fixtures are go to full bright when without windows or that of fixtures ¡ HVAC control available through system-wide
controlled together or occupied have loads <150W in BACnet interface option on the nLight
independently ¡ Fixtures automatically sidelit zones ECLPYSE™ controller
¡ Maximum level can be turn off or optionally can ¡ Wireless fixture embedded control and occupancy/
task tuned to be configured to drop daylighting sensor options available, please see the
any percentage to low dim setting when fixture specification sheet
via programming space becomes vacant ¡ For emergency lighting control use a power pack
with ER/EM option or nLight Enabled Fixture with
emergency option

Note: Contact your local lighting agent for more information on nLight enabled fixtures.

www.nlightcontrols.com • 800-535-2465
CORRIDOR with 0-10V Dimming Fixtures 17

Wired Wireless

nPP16 D rPP20 D 24V


nCM 10 nCM 10 rCMSB PDT 7 rCMSB PDT 7

nPODMA EM nPODMA rPODBA EM rPODBA

nPP16 D ER rPP20 D 24V EM

nCM 10
CAT-5e rCMSB PDT 7
Low Voltage
Cable Wires

Line Voltage Line Voltage


Wires Wires

Line Power Line Power


EM

EM
Feed Feed

0-10V Wires 0-10V Wires

nCM 10 EM Power Feed rCMSB PDT 7


EM Power Feed
nPODMA
rPODBA

Bill of Materials Bill of Materials


Symbol Qty Product # Description Symbol Qty Product # Description

Relay Pack with 0-10V Relay Pack with 0-10V


1 nPP16 D EFP 1 rPP20 D 24V EFP G2
Dimming Output Dimming Output
Emergency Relay Pack with rPP20 D 24V EM Emergency Relay Pack with
1 nPP16 D ER EFP 1
0-10V Dimming Output EFP G2 0-10V Dimming Output
Battery Powered
4 nCM 10 RJB Occupancy Sensor 4 rCMSB PDT 7 G2
Occupancy Sensor
Battery Powered, On/Off
3 nPODMA On/Off WallPod 3 rPODBA G2
WallPod

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Daylight Control: Manual Control: ¡ Room can be connected to nLight backbone
¡ All fixtures are dimmable ¡ Fixtures automatically ¡ Not required for areas ¡ On/off control to enable network control or time schedules
¡ Maximum level can be go to full bright when without windows or that of fixtures ¡ HVAC control available through system-wide BACnet
task tuned to occupied have loads <150W in ¡ If switch poses a safety interface option on the nLight ECLPYSE™ controller
any percentage ¡ Fixtures automatically sidelit zones concern, optionally can ¡ For emergency lighting control use a power pack
via programming turn off or optionally can be programmed for with ER/EM option or nLight Enabled Fixture with
be configured to drop ‘on’ only. emergency option
to low dim setting when
space becomes vacant

ASHRAE 90.1–2019: nLight Applications Guide


18 RESTROOM with nLight Enabled Fixtures

Wired Wireless

rPODBA DX rPODBA DX
nPODMA DX nPODMA DX rPODBA DX rPODBA DX

nCM PDT 9 nCM PDT 9

1 1

1 1
EM EM
1 1
EM EM EM EM

1 Some nLight enabled EM fixtures require a normal sense line connection. 1 Fixture(s) assumed to include power interruption detection emergency option.
Wiring shown assumes battery backup emergency option. See fixture spec sheets for details. For battery backup
1 Fixture(s) option,
assumed no dedicated
to include power EM circuit necessary.
interruption detection emergency option.
For battery backup option, no dedicated EM circuit necessary.
CAT-5e Cable Line Voltage Wires Line Power Feed Line Voltage Wires Line Power Feed EM Power Feed

Bill of Materials Bill of Materials


Symbol Qty Product # Description Symbol Qty Product # Description

nLight AIR Enabled Troffer


2 See Note nLight Wired Enabled Troffer 2 See Note
with Sensor Option
nLight Wired Enabled Troffer nLight AIR Enabled Troffer
2 See Note 2 See Note
with Battery Option with Sensor and EM Option
Battery Powered, On/Off,
2 nPODMA DX On/Off, Raise/Lower WallPod 2 rPODBA DX G2
Raise/Lower WallPod

2 nCM PDT 9 RJB Occupancy Sensor

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Manual Control: ¡ Room can be connected to nLight backbone
¡ All fixtures are dimmable ¡ Fixtures automatically go to ¡ On/off & raise/lower control to enable network control or time schedules
¡ All fixtures are controlled full bright when occupied (or of fixtures ¡ HVAC control available through system-wide
together or independently optionally can be configured to ¡ If switch poses safety concerns, BACnet interface option on the nLight
(per room) come on automatically to 50%) optionally can be programmed ECLPYSE™ controller
¡ Maximum level can be task ¡ Fixtures automatically turn off for “on only” ¡ Fixture embedded control and occupancy/
tuned to any percentage via or optionally can be configured daylighting sensor options available, please see the
programming to drop to low dim setting when fixture specification sheet
space becomes vacant ¡ For emergency lighting control use a power pack
with ER/EM option or nLight Enabled Fixture with
emergency option

Note: Contact your local lighting agent for more information on nLight enabled fixtures.

www.nlightcontrols.com • 800-535-2465
RESTROOM with 0-10V Dimming Fixtures 19

Wired Wireless

nPODMA DX nPODMA DX rPODBA DX rPODBA DX

nCM PDT 9 nCM PDT 9 rCMSB PDT 7 rCMSB PDT 7

nPP16 D nPP16 D rPP20 D 24V rPP20 D 24V

nPP16 D ER nPP16 D ER rPP20 D 24V EM rPP20 D 24V EM

EM EM EM EM

CAT-5e Cable 0-10V Wires Line Voltage Wires Line Power Feed EM Power Feed 0-10V Wires Line Voltage Wires Line Power Feed EM Power Feed

Bill of Materials Bill of Materials


Symbol Qty Product # Description Symbol Qty Product # Description

Relay Pack with 0-10V Relay Pack with 0-10V


2 nPP16 D EFP 2 rPP20 D 24V EFP G2
Dimming Output Dimming Output
Emergency Module with rPP20 D 24V EM Emergency Relay Pack with
2 nPP16 D ER EFP 2
0-10V Dimming Output EFP G2 0-10V Dimming Output
On/Off & Raise/Lower Battery Powered, On/Off &
2 nPODMA DX 2 rPODBA DX G2
WallPod Raise/Lower WallPod
Battery Powered
2 nCM PDT 9 RJB Occupancy Sensor 2 rCMSB PDT 7 G2
Occupancy Sensor

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Manual Control: ¡ Room can be connected to nLight backbone
¡ All fixtures are dimmable ¡ Fixtures automatically go to ¡ On/off & raise/lower control to enable network control or time schedules
¡ Maximum level can be task full bright when occupied (or of fixtures ¡ HVAC control available through system-wide
tuned to any percentage via optionally can be configured to ¡ If switch poses safety concerns, BACnet interface option on the nLight
programming come on automatically to 50%) optionally can be programmed ECLPYSE™ controller
¡ Fixtures automatically turn off for “on only” ¡ Wireless fixture embedded control and occupancy/
or optionally can be configured daylighting sensor options available, please see the
to drop to low dim setting when fixture specification sheet
space becomes vacant ¡ For emergency lighting control use a power pack
with ER/EM option or nLight Enabled Fixture with
emergency option

ASHRAE 90.1–2019: nLight Applications Guide


20 STAIRWELL with nLight Enabled Fixtures/0-10V Dimming Fixtures

Wireless with nLight Enabled Fixtures Wireless with 0-10V Dimming Fixtures

EM EM
1 rPP20 D 24V EM

rCMSB PDT 7

Line Voltage
Wires

Line Power
Feed
Line Power
Feed 0-10V Wires

rPP20 D 24V
rCMSB PDT 7
EM Power
EM Power Feed
Feed

1 Fixture(s) assumed to include power interruption detection emergency option.


For battery backup option, no dedicated EM circuit necessary.

Bill of Materials Bill of Materials


Symbol Qty Product # Description Symbol Qty Product # Description

nLight AIR Enabled Fixture rPP20 D 24V EFP Relay Pack with 0-10V
1 See Note 1
with Sensor Option G2 Dimming Output
rPP20 D 24V EM Emergency Relay Pack with
1
nLight AIR Enabled Fixture EFP G2 0-10V Dimming Output
1 See Note
with Sensor and EM Option Battery Powered
2 rCMSB PDT 7 G2
Occupancy Sensor

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Manual Control: ¡ Room can be connected to nLight backbone
¡ All fixtures are dimmable ¡ Fixtures automatically go to full ¡ Safety may preclude the use of a to enable network control or time schedules
¡ Maximum level can be task bright when occupied manual control in these areas ¡ HVAC control available through system-wide
tuned to any percentage ¡ Fixtures automatically turn off BACnet interface option on the nLight
via programming or optionally can be configured ECLPYSE™ controller
to drop to low dim setting when ¡ Wireless fixture embedded control and occupancy/
space becomes vacant daylighting sensor options available, please see the
fixture specification sheet
¡ For emergency lighting control use a power pack
Note: Contact your local lighting agent for more information on nLight enabled fixtures. with ER/EM option or nLight Enabled Fixture with
emergency option

www.nlightcontrols.com • 800-535-2465
GYMNASIUM with nLight Enabled Fixtures/0-10V Dimming Fixtures 21

Wireless with nLight Enabled Fixtures Wireless with 0-10V Dimming Fixtures

rPODBA 2P
rPODBA 2P

rPP20 D 24V EM

E E E E
M M M M
1 1
rCMS 6 rCMS 6

rPODBA DX rPODBA DX

rPP20 D 24V

E E
M M

rCMS 6 rCMS 6

E E
M M
rPP20 D 24V

rCMS 6 rCMS 6

rPP20 D 24V EM

E E E E
M 1 1 M M M
1 1
EM EM

rPODBA 2P rPODBA 2P

rPODB 2P

1 Fixture(s) assumed to include power interruption detection emergency option.


n
For battery backup option, no dedicated EM circuit necessary.
rLSXR 6 EM rLSXR 6 rLSXR 6 rLSXR 6 EM
E E
M M
n

n
n

rPODB 2P

Line Voltage Wires n Line Power Feed EM Power Feed Low Voltage Wires 0-10V Wires Line Voltage Wires Line Power Feed EM Power Feed
rLSXR 6 rLSXR 6 rLSXR 6 rLSXR 6

rLSXR 6 EM
n n

n n

n n
n n

rLSXR 6 rLSXR 6 rLSXR 6 EM


E E
M M

rLSXR 6 rLSXR 6 EM rLSXR 6 rLSXR 6


E
M
n n

n n

n n

rLSXR 6
n n

rLSXR 6 rLSXR 6 rLSXR 6

Bill of Materials rLSXR 6 rLSXR 6 rLSXR 6 EM rLSXR 6


Bill of Materials
E
M
rLSXR 6 EM
n n

n n
n n

rLSXR 6 rLSXR 6 rLSXR 6


n n

E
M
Symbol Qty Product # Description Symbol Qty Product # Description

nLight AIR Enabled Fixture Relay Pack with 0-10V


rLSXR 6 rLSXR 6 rLSXR 6 rLSXR 6

2 rPP20 D 24V EFP G2


n n

n n

n n

n n

rLSXR 6 rLSXR 6 rLSXR 6 EM rLSXR 6

18 E
M See Notes
with Sensor Option Dimming Output
rLSXR 6 EM rLSXR 6 rLSXR 6 rLSXR 6 EM
nLight AIR Enabled Fixture rPP20 D 24V EM Emergency Relay Pack with
E
M
rLSXR 6
6
rLSXR 6
See Notes
E
rLSXR 6 rLSXR 6
2
n n

n n
n n

nn

M
with Sensor and EM Option EFP G2 0-10V Dimming Output
rPODB 2P rPODB 2P
n
Battery Powered, 2-Pole, Battery Powered, 2-Pole,
2 rPODBA 2P G2
rPODB 2P

E
rLSXR 6 EM rLSXR 6 rLSXR 6 rLSXR 6 EM

On/Off WallPod 2 rPODBA 2P G2


M
E
On/Off WallPod
n

n
n

n
rPODB 2P
6 rCMS 6 G2 High Bay Occupancy Sensor
E E E E
M M M M

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Daylight Control: ¡ Room can be connected to nLight backbone
¡ All fixtures are dimmable ¡ Fixtures automatically go ¡ Daylight responsive controls to enable network control or time schedules
¡ Maximum level can be task to full bright when occupied lights to full off when adequate ¡ HVAC control available through system-
tuned to any percentage ¡ Fixtures automatically daylight present wide BACnet interface option on the nLight
E E
via programmingM turn off or optionally can M
¡ Not required for spaces without ECLPYSE™ controller
be configured to drop to skylights or that have loads ¡ Wireless fixture embedded control and
low dim setting when space <150W in toplit zones occupancy/daylighting sensor options available,
becomes vacant please see the fixture specification sheet
E E emergency lighting control use a power
M ¡ ForM
pack with ER/EM option or nLight Enabled
Fixture with emergency option

Note: Contact your local lighting agent for more information on nLight enabled fixtures.

E E E E
M M M M
ASHRAE 90.1–2019: nLight Applications Guide

rPODB 2P rPODB 2P
22 WAREHOUSE/STORAGE Wireless Enabled Fixtures/0-10V Dimming Fixtures

Wireless with nLight Enabled Fixtures Wireless with 0-10V Dimming Fixtures

rPODBA 2P rPODB 2P rPP20 D 24V rPP20 D 24V EM


rCMS 6 rCMS 6

rPP20 D 24V

EM
rPP20 D 24V EM

EM EM EM EM EM
1 1 1

rCMS 6

STORAGE RACKS rPP20 D 24V


STORAGE RACKS
EM rCMS 6 rCMS 6
rPP20 D 24V EM

EM EM EM EM
1 1 1

STORAGE RACKS STORAGE RACKS


rPP20 D 24V

rPODB 2P EM rCMS 6 rCMS 6


rPP20 D 24V EM
rPODBA 2P
EM EM EM EM EM
1 1 1

rPODBA 2P
STORAGE RACKS STORAGE RACKS rPODBA 2P

EMG
rPP20 D 24V

rPODB 2P EM rCMS 6 rCMS 6

EMG EMG
rPP20 D 24V EM
rPODBA 2P
EM EM EM EM
1 1 1

STORAGE RACKS
rCMS 6
STORAGE RACKS
STORAGE RACKS
rPP20 D 24V

rCMS 6
EMG rCMS 6
EM

EMG EMG
rPP20 D 24V EM

EM EM EM EM EM
1 1 1
EMG

EMG EMG
STORAGE RACKS 1 Fixture(s) assumed to include power interruption detection emergency option.
For battery backup option, no dedicated EM circuit necessary.

STORAGE RACKS EMG

Line Voltage Wires


EMG Line Power Feed EM Power Feed EMG Low Voltage Wires 0-10V Wires
EMG
Line Voltage Wires Line Power Feed EM Power Feed
EMG
STORAGE RACKS EMG

rPODB 2P
STORAGE RACKS EMG

EMG EMG

Bill of Materials Bill of Materials


EMG

STORAGE RACKS
rPODB 2P
rPODB 2P EMG EMG

Symbol Qty STORAGE


Product # RACKS Description Symbol Qty EMG Product # Description
rPODB 2P
EMG EMG
nLight AIR Enabled High Bay EMG Relay Pack with 0-10V
20 See Note 6 rPP20 D 24V EFP G2
EMG
STORAGE RACKS
Fixture withEMG
Sensor Option Dimming Output
nLight AIR Enabled High Bay rPP20 D 24V EM Emergency Relay Pack with
15 See Note Fixture withEMG
Sensor and 6 EMG

EMG
EFP G2 0-10V Dimming Output
EM Option rPODB 2P

Battery Powered, 2-Pole,


rPODB 2P

Battery Powered, 2-Pole, 3 rPODBA 2P G2


3 rPODBA 2P G2 On/Off WallPod
On/Off WallPod
12 rCMS 6 G2 High Bay Occupancy Sensor
E E
E E M M
M M

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Daylight Control: ¡ Room can be connected to nLight backbone
¡ All fixtures are dimmable ¡ Fixtures automatically go ¡ Daylight responsive controls to enable network control or time schedules
¡ Maximum level can be task to full bright when occupied lights to full off when adequate ¡ HVAC control available through system-wide
tuned to any percentage ¡ Fixtures automatically daylight present BACnet interface option on the nLight
E
via programming
E turn off or optionally can M
¡ Not required for spaces without ECLPYSE™ controller
M
be configured to drop to skylights or that have loads ¡ Wireless fixture embedded control and occupancy/
low dim setting when space <150W in toplit zones daylighting sensor options available, please see the
becomes vacant fixture specification sheet
E emergency lighting control use a power pack
¡ For
E M
M with ER/EM option or nLight Enabled Fixture with
emergency option

Note: Contact your local lighting agent for more information on nLight enabled fixtures.

E E
E E M M
M M

rPODB 2P

rPODB 2P

www.nlightcontrols.com • 800-535-2465
PARKING AREA (GARAGE), INTERIOR with nLight AIR Enabled Fixtures 23

Wireless Parking Garage

ELEC/MECH/DATA

NECY MVOLT ENC GFXK

STAIRS

PS 150
NECYD NLTAIR
n

ELEVATOR LOBBY

EM

UP Low Voltage
Wires

DWN
USB Cable

STAIRS
Line Voltage
Wires
STAIRS
EM

n n
Line Power
Feed
n n

n n EM Power
Feed
n n IN
UP

n n
OUT
UP
DWN
n n
Fixture(s) assumed to include power interruption detection emergency option.
DWN
For battery backup option, no dedicated EM circuit necessary.
n n

Bill of Materials
n n
Symbol Qty Product # Description
n n
13 See Note nLight AIR Enabled Canopy Fixture with Sensor Option
n n

ELEC/MECH/DATA
2 See Note nLight AIR Enabled Canopy Fixture with Sensor and EM Option
NECY MVOLT ENC GFXK

IN
1 nECY nLight ECLYPSE™ Network
STAIRS
System Controller
OUT PS 150
NECYD NLTAIR
n

IN
LAN
1 nECYD NLTAIR G2 nLight AIR Adapter
OUT
ELEVATOR LOBBY

nLight ECLYPSE EM

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:

Light Fixtures: Occupancy Control: Daylight Control: ¡ Devices can be connected to nLight backbone
¡ All fixtures are dimmable ¡ Fixtures automatically go ¡ Daylight responsive controls to enabled network control or time schedules,
to full bright when occupied lights to full off when adequate including astronomical time schedules
¡ All fixtures can be controlled
UPautomatically daylight present for shutoff. GFXK option can be added to
together or independently ¡ Fixtures
nLight ECLYPSE™ to provide manual override
¡ Maximum level can be task turn off or optionally can
(9.4.4.1[a]).
tuned to any percentage be configured to drop to
low dim setting when space ¡ Wireless fixture embedded control and
via programming DWN
becomes vacant occupancy/daylighting sensor options available,
please see the fixture specification sheet
¡ For emergency lighting control use a power
Note: Contact your local lighting agent for more information on nLight enabled fixtures. pack with ER/EM option or nLight Enabled
Fixture with emergency option
EM

ASHRAE 90.1–2019: nLight Applications Guide


24 EXTERIOR LIGHTING with nLight AIR Enabled Fixtures

Wireless Site Lighting

Low Voltage
Wires
n

USB Cable
n

n Line Voltage
n
n
rPODB 2P Wires
NECYD
NLTAIR

Line Power
NECY MVOLT ENC GFXK
Feed
n

PS 150

NECYD NLTAIR

IN
n

OUT
n

Bill of Materials
IN
n n
n

Symbol Qty Product # Description


n
OUT
5 See Note nLight AIR Enabled Area Fixture

ELEC/MECH/DATA
5 See Note nLight AIR Enabled Wall Mount
n n
NECY MVOLT ENC GFXK

1 nECY nLight ECLYPSE™ Network


STAIRS
System Controller
PS 150
NECYD NLTAIR
n

LAN
ELEVATOR LOBBY
1 nECYD NLTAIR G2 nLight AIR Adapter
4.83 5.83

2 rSBOR nLight AIR Outdoor Box Mount Sensor


EM
4.005

nLight ECLYPSE
[BLANK] Short extension, low back EB4 Medium extension, low back EB2 Long extension, low back

4.06 4.83 5.83

OPERATIONAL DETAILS: ADDITIONAL OPTIONS:


IN
5.04

2.24 3.005 4.005

EB1 Short extension, high back EB5 Medium extension, high back EB3 Long extension, high back

Light Fixtures: Occupancy Control: Daylight Control: ¡ Devices can be connected to nLight backbone
¡ All fixtures are dimmable ¡ Fixtures automatically go ¡ Daylight responsive controls to enabled network control or time schedules,
OUT

to full bright when occupied lights to full off when adequate including astronomical time schedules for
¡ All fixtures can be controlled
UP daylight present lighting shutoff (9.4.1.4[b]) and lighting setback
together or independently ¡ Fixtures automatically
(9.4.1.4[c]). GFXK option can be added to
¡ Maximum level can be task turn off or optionally can
nLight ECLYPSE™ to provide manual override
tuned to any percentage be configured to drop to
(9.4.4.1[a]). Luminaires reduced to 50% when no
via programming low dim setting when space
DWN activity is detected for 15-minutes (9.4.1.4[d]).
becomes vacant
¡ Wireless fixture embedded control and
occupancy/daylighting sensor options available,
please see the fixture specification sheet
n

Note: Contact your local lighting agent for more information on nLight enabled fixtures. ¡ For emergency lighting control use a power
EM pack with ER/EM option or nLight Enabled
Fixture with emergency option
¡ Outdoor nLight AIR devices (such as the rSBOR
sensors shown) can repeat wireless, network
messages around corners.

www.nlightcontrols.com • 800-535-2465

IN
nLight Hybrid Networked Lighting Control: Programmable Timeclock 25

LAN EM
rPODB EM rPODB

1 1

Bridge

nLight ECLYPSE™

nPP16 D ER
nWSXA PDT LV DX
nPP20
nPP20 PL
PL nWSX PDT LV DX

DZ
nPODM DX

EM
EM

1
nCM PDT 9 nCM PDT 9

nPP16 D

nCM ADCX

rPODB

1 Fixtures assumed to be battery backup


EM

1 Fixtures assumed to be battery backup


nCM PDT 9
nCM PDT 9

nPP16 D
nPODM DX
nPP16 D nPP16 D

Programmable Time Clock Control:


Although not pictured within each of the individual room design
guides, each nLight controlled space can be connected via an
nLight backbone to create a networked nLight lighting control
Bill of Materials system capable of meeting the requirements of ASHRAE 90.1
scheduled shutoff, provision 9.4.1.4[i]. A networked system also
Symbol Qty Product # Description enables astronomical time clock control.

1 nBRG 8 KIT 8-Port Backbone Bridge

nLight ECLYPSE™ Network


nECY
ECLYPSE ™ ECLYPSE ™ ECLYPSE ™

1 System Controller and


MVOLT ENC
Optional BMS Interface

LAN nECYD
1 nLight AIR Adapter
NLTAIR G2

nLight ECLYPSE

ASHRAE 90.1–2019: nLight Applications Guide


26 APPENDIX A: Requirements Overview

Control Code
nLight Solution Details
Requirement Provision

nLight WallPod devices provide a user with local control of lighting within an nLight controlled space.
WallPods are available in multiple styles — each with varying features and user experiences.

Push-Button WallPod Graphic WallPod*


Local
(i.e. Switch) 9.4.1.1[a]
Control
nPODMA Series nLight UNITOUCH
rPODBA Series Touchscreen Wall Switch

Traditional tactile buttons and LED user feedback. Full-color touch screen provides a sophisticated look and feel.

Individual nLight control groups (i.e.: rooms) can be easily networked together across an entire building simply by connecting them into a
“backbone” made up of one or more nLight bridge devices and/or nLight AIR adapters and an nLight ECLYPSE™ system controller. The system
controller provides programmable time clock functionality for an nLight network as well as interfaces to the SensorView suite of web-based software
applications (via an Ethernet LAN / WAN connection).

Scheduled Network System Controller


Shutoff & 9.4.1.1[i]
Shut-Off Control

Off During 9.4.1.1[j]


Non-Business 9.4.1.4
Hours
Network System Controller

Additional benefits of installing an nLight backbone include remote status monitoring, system-wide configuration changes, optional building
management system integration, and optional automated demand response through OpenADR 2.0a.

Automatic
nLight occupancy sensors utilize 100% digital passive infrared (PIR) detection, come in several mounting styles, and offer multiple coverage pattern
Full OFF Via
9.4.1.1[h] options. Additionally, nLight sensors are available with patented MicrophonicsTM dual technology detection for rooms with obstructions. Configuring
Occupancy
for full off vs. partial off control is done with system programming.
Sensor

360° Occupancy Sensor 120° WideView Corner Sensor*

Automatic nCM Series


Partial OFF rCMS Series nWV Series
9.4.1.1[g]
Via Occupancy rCMSB Series
Sensor

Surface mounts to ceiling tiles or sheetrock/plaster. Directly mounts in corner or to ceiling via repositionable ceiling bracket.

*Available with nLight Wired products only.


Note: This summary is for general information purposes only and is provided without any warranty as to accuracy, completeness, or otherwise. The user should read the applicable code sections for more complete and
detailed descriptions of code requirements and exceptions and should consult with a professional engineering or other competent advisor before making any decision or taking any action based on this summary.

www.nlightcontrols.com • 800-535-2465
APPENDIX B: Requirements Overview 27

Control Code
nLight Solution Details
Requirement Provision

nLight provides multiple options for controlling continuous dimming luminaires. This allows spaces with several lighting types and technologies to
be controlled together and with a common user experience.

nLight Enabled Acuity Brands Fixtures Dimming Relay Packs

Bi-Level
Lighting 9.4.1.1[d] nPP16 Series
Control rPP20 Series

Acuity Brands offers a wide variety of LED fixtures with factory installed nLight dimming relay enable control of any 0-10VDC dimmable
Light Level Control

integrated nLight controls that provide smooth continuous dimming. LED luminaire.

nLight offers standalone daylight harvesting sensors as well as occupancy sensors with integrated daylight harvesting. Sensors are available in
various housings and provide continuous dimming control of any/all networked nLight enabled fixtures or dimming relay packs, each capable of
being its own daylight zone.

Automatic
Daylight
Responsive 9.4.1.1[e] Ceiling Mount Dimming Photocell Recessed Mount Dimming Photocell*
Controls for 9.4.1.1[f]
Sidelighting/
Toplighting
nCM Series
rCMS Series nRM Series
rCMSB Series

The nLight Plug Load Relay Pack is capable of switching an entire 20A receptacle load. Simply add an occupancy sensor to an nLight Control Zone
(room) and the sensor will automatically switch off when the room is vacant.
Additional Controls

Plug Load / Receptacle Relay Pack


Automatic
Receptacle
8.4.2
(i.e. Plug Load)
Control

nPP20 PL Series rPP20 Series

ASHRAE 90.1–2019: nLight Applications Guide


28 nLight Enabled Fixtures

nLight Enabled Fixtures


Acuity Brands offers the industry’s broadest portfolio of controls enabled fixtures.
Please scan the QR code to see the current nLight enabled fixtures.

nLight AIR Enabled Luminaires nLight Wired Enabled Luminaires

Mobile Apps
Quick and Easy Lighting Configuration and Control In the Palm of Your Hand

nLight Wired nLight AIR

nLight BLE Radio Module nConfig™ CLAIRITY™ Pro


nLight wired uses the nIO BT (Bluetooth Low
®
The nConfig mobile app is for nLight The CLAIRITY Pro mobile app
Energy radio module) to communicate with wired controls startups. It’s a quick allows you to start up, configure
the nConfig app to modify the settings and and easy alternative to SensorView and troubleshoot nLight AIR
operation of the devices in an nLight zone. software for smaller projects and wireless controls from a compatible
simple programming. smartphone or tablet.

www.nlightcontrols.com • 800-535-2465
Specification Tools 29

Specification Tools
We have developed a set of productivity tools to help you do your job faster and easier.
Using our easy-to-use tools, you can specify and design with confidence more quickly.

Develop Your Sequence of Spec Builder - Build Your Spec A Quicker Way to do a Design
Operations Faster Faster and Easier Take-Off
Methodik is an online tool that generates a We have developed an online tool The Visual Controls software supports efficient
sequence of operations quickly, designed designed to make the creation and design and specification with Acuity Controls.
to save time and increase your productivity. manipulation of project specifications You can quickly perform a design take-off to
The sequence of operations can export your faster and easier. bid a project and generate a comprehensive
project into DXF, PDF, and CSV file formats to professional submittal.
include in your electrical set. Additionally, it Spec Builder includes Division 26,
gives recommendations on products that can network lighting control specification To get access to the Visual Controls software,
be used in each space--fixtures and controls language, as well as Division 23 and please contact your local lighting agent to get
side by side. Division 25 HVAC and integration access today.
specification language.
Get The Tool! Get Access Now
https://methodik.acuitybrands.com/#/ Build Your Spec Now! https://www.acuitybrands.com/support/
https://www.spec.build/ how-to-buy

ASHRAE 90.1–2019: nLight Applications Guide


nLight®
ASHRAE 90.1−2019 Applications Guide

In addition to being North America’s leading manufacturer of indoor and outdoor luminaires, Acuity Brands offers
an extensive portfolio of advanced lighting control and building technology solutions for indoor and outdoor
applications, from single-room control to fully connected smart building management. Our products, technology,
expertise and support include occupancy and photosensors, centralized and distributed systems, panels, luminaire-
integrated wired/wireless networked controls and IoT platform services.

nLight Typical Layout Drawings


http://www.acuitybrands.com/typicals

ASHRAE
https://www.ashrae.org/

Use the Following Sections of the ASHRAE 90.1–2019


Code as Reference:
Section 8.4.2 – Automatic Receptacle Control
Section 9.4.1.1[a] – Local Control
Section 9.4.1.1[b] – Manual On
Section 9.4.1.1[c] – Partial Automatic On
Section 9.4.1.1[d] – Bi-Level Lighting Control
Section 9.4.1.1[e] – Automatic Daylight Responsive Control for Sidelighting
Section 9.4.1.1[f] – Automatic Daylight Responsive Controls for Toplighting
Section 9.4.1.1[g] – Automatic Partial Off
Section 9.4.1.1[h] – Automatic Full Off
Section 9.4.1.1[i] – Scheduled Shutoff
Section 9.4.1.1[j] – Scheduled Shutoff During Non-Business Hours
Section 9.4.1.2 – Parking Garage Lighting Control
Section 9.4.1.4 – Exterior Lighting Control

A+ Certified solutions from Acuity Brands help you


quickly and confidently select and implement lighting
systems that are both compatible and consistent.

For lighting applications, A+ means verified consistent


performance, visual appearance and system interoperability of all
luminaires and controls within the certified solutions. For lighting
professionals it means confidence that all parts of the lighting system
will work together and meet common Acuity Brands specifications.

Go to www.acuitybrands.com/solutions/a-certified or contact your


local Acuity Brands representative for more information.

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any
use of such marks by Acuity Brands Lighting is under license.

One Lithonia Way | Conyers, Georgia 30012 | Phone: 800.535.2465


©2015 Acuity Brands Lighting, Inc. All rights reserved. | NL_575140_1220
©2020 04/15 | SSI_1832