You are on page 1of 17

Quick Start Guide

SpeedFace - V5L[TI]
Version: 1.0

Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between
the actual product and the written information in this manual.
Overview

Thermal Imaging Temperature


Detection Module

Flash
Camera & Palm Collector
Microphone

5" touchscreen

Fingerprint Sensor

Magnetic Tamper
Speaker Reset Switch

AUX Auxiliary
12V GND input
Power in
GND RXD2 TX+ SEN Sensor
TXD2 RS232 TX- GND
Ethernet Exit Button
+12V GND RX+ BUT
GND RXD RX- NO1
IWD0 Wiegand TXD RS232 COM Lock
IWD1 in GND NC1
WD0 Wiegand 485A AL+
out RS485 Alarm
WD1 485B AL-

Note: Not all products have the function with , the real product shall prevail.

1
Installation Environment
Please refer to the following recommendations for installation.

INSTALL INDOORS AVOID INSTALLATION AVOID DIRECT AVOID USE OF ANY


ONLY NEAR SUNLIGHT HEAT SOURCE
GLASS WINDOWS AND EXPOSURE NEAR THE DEVICE

Recommended Palm Gestures

KEEP EFFECTIVE KEEP SPACES DO NOT KEEP DO NOT KEEP DO NOT KEEP
DISTANCE OF BETWEEN YOUR FINGERS PALM OUTSIDE YOUR FINGERS
30-50 cm YOUR FINGERS CLOSE COLLECTION AREA FOLD/CURLED

Note:
1. Place your palm within 30-50 cm of the device.
2. Place your palm in the palm collection area, such that the palm is placed parallel
to the device.
3. Make sure to keep space between your fingers.

Recommended Standing Position

KEEP EFFECTIVE
DISTANCE OF
0.3-2m
2
Installation Requirements
The installation requirements and indications associated with the device are given
below:

Specification Standard value Remark


Operating Indoor, Avoid wind, Avoid The recommended operating
Environment direct sunlight, temperature is 25°C (77°F)
16°C to 35°C (60.8°F to 95°F)
Distance The recommended distance
(between face 30 to 120cm (0.98ft to 3.94ft)
is 80cm (2.62ft)
and device)
This value is tested at a distance
Measurement
±0.3°C (±0.54°F) of 80cm or 2.63ft under 25°C
Accuracy
(77°F) environment.
Notes: The temperature measurement data is only for reference, and not for any
medical purposes.

Forehead Temperature Detection Indoor constant Temperature


Environment

Installation height: 1.55m

FOV (Field Of View) of the thermal


imaging device: 50 °

Temperature detection distance:


0.3m to 1.2m

Height of the face adapted for


detection: 1.2m to 2m

155CM

3
Device Installation
1 2 3

1.5m

① Attach the mounting template sticker to the wall, and drill holes according to the
mounting paper. Fix the back plate on the wall using wall mounting screws.

② Attach the device to the back plate.


③ Fasten the device to the back plate with a security screw.

Standalone Installation

Alarm Smoke
detector

Door sensor

Exit button

Card Lock TCP/IP


reader

4
Power Connection

12V 12V DC
GND GND

Recommended power supply


1) 12V ± 10%, at least 3000mA.
2) To share the power with other devices, use a power supply with higher current
ratings.

Ethernet Connection

TX+ 1
TX- 2
3
4
RX+ 5
6
RJ 45
RX- 7
8

IP address: 192.168.1.130
Default IP address: 192.168.1.201 Subnet mask: 255.255.255.0
Subnet mask: 255.255.255.0

Click [COMM.] > [Ethernet] > [IP Address] , input the IP address and click [OK].
Note: In LAN, IP addresses of the server (PC) and the device must be in the same
network segment when connecting to ZKBioAccess MTD software.

5
Door Sensor, Exit Button & Alarm Connection
Smoke Detector
AUX
GND Door Sensor
SEN
GND
BUT
ExitButton NO1
COM
Alarm's power switch NC1
AL+
AL-
Alarm

Lock Relay Connection


The system supports both Normally Opened Lock and Normally Closed Lock.
The NO Lock (normally opened when powered) is connected with 'NO1' and
'COM' terminals, and the NC Lock (normally closed when powered) is connected
with 'NC1' and 'COM' terminals. The power can be shared with the lock or can be
used separately for the lock, as shown in the example with NC Lock below:
1) Device not sharing power with the lock 2) Device sharing power with the lock

+12V +12V
GND GND
DC12V AUX DC12V AUX
GND GND
SEN SEN
GND GND
BUT BUT
DC12V NO1 NO1
COM COM
FR107
NC1 NC1
FR107
AL+ Normally Closed Lock AL+
Normally Closed Lock AL- AL-

6
Wiegand Reader Connection
Wiegand card reader connects to the top 4 pins of the wiegand terminal and the last
two pins are used by the Access controller, as shown in the following figure. It sends the
credentials to the device via wiegand communication.

+12V
GND
IWD0
IWD1
WD0
WD1 Wiegand Reader

Access controller

RS485 and RS232 Connection


The RS485 and the RS232 lets user connect to multiple readers to the device. Two RS232
and one RS485 can be connected to the terminal, as shown in the figure below.

TXD
RXD2
RS232 RXD
TXD2
Reader GND GND
GND
TXD RS232
RXD
RXD Reader
TXD
GND
GND
RS485 485+
485A
Reader 485-
485B

7
User Registration
When there is no super administrator set in the device, click on to enter the menu.
Add a new user and set User Role to Super Admin, then the system will request for the
administrator’s verification before entering the menu. It is recommended to register a
super administrator initially for security purposes.
Method 1: Register on the device
Click on > [User Mgt.] > [New User] to register a new user. The options include
entering the user ID and Name, setting User Role, registering Palm, Fingerprint, Face,
Password, Badge (optional), and adding User Photo.
2020-03-05 14:31 Main Menu User Mgt.

New User

L
User Mgt. User Role COMM. System All Users

Display Style

Personalize Data Mgt. Access Control Attendance


Search

Autotest System Info


2020-03-05 Thursday

Welcome

L
New User Palm Registration Enroll Face

User ID 1

Name Mike

User Role Normal User

Palm 1

Fingerprint 1

Face 1

Password *****

User Photo 1

Access Control Role

Enrolled Successfully Enrolled Successfully

8
Method 2: Register on ZKBioAccess MTD software
Please set the IP address and cloud service server address in the Comm. Menu option
on the device.
1. Click [Access] > [Access Device] > [Device] > [Search Device] to search the device
on the software. When an appropriate server address and port is set on the device,
the searched devices are displayed automatically.
Refresh New Delete Export Search Device Device Control Set up View and Get Device Info Communication

Search Device
Step 1
Search No device found? Download Search Tools to Local Disk

Total Progress
Step 2 Searched devices count:1

IP Address Device Type Serial Number

IP Address MAC Address Subnet Mask Gateway Address Serial Number Device Type Set Server Operations Step 3
192.168.213.79 255.255.255.0 192.168.213.1 Add

Add

Device Name 192.168.213.79

Icon Type Door

Area Area Name


The current systen communication port is 6609, please make sure the device is set correctly.
Add to Level
Close
Clear Data in the Device when Adding

[Clear Data in the Device when Adding] will delete data in the device(except event
record), please use with caution!

Step 4
OK Cancel

2. Click [Add] in operation column, a new window will pop-up. Select Icon type, Area,
and Add to Level from each dropdowns and click [OK] to add the device.
3. Click [Personnel] > [Person] > [New] and fill in all the required fields to register
a new users in the software.
4. Click [Access] > [Device] > [Device Control] > [Synchronize All Data to Devices]
to synchronize all the data to the device including the new users.

For more details, please refer to the ZKBioAccess MTD User Manual.

9
Method 3: Register on the phone
Once the ZKBioAccess MTD software is installed, the users could enroll their face via a
browser application on their own mobile phone.
1. Click [Personnel] > [Parameters], input ‘’http://Server address: Port’’ in the QR Code
UGL bar. The software will automatically generate a QR code. Scan the QR code or
login onto ‘’http://Server address: Port/app/v1/adreg’’ by the mobile phone to
register users.
Personnel Registration

Personnel Registration Personnel ID Setting

Personnel The Maximum Length: 9


Support Letters: Yes No
Personnel ID Auto-increment: Yes No
Person

Department Card Setting

Temporary Personnel The Maximum Length: 32 Bits(Binary)


Card Format Display: Decimal Hexadecimal
Custom Attributes
Personnel ID
Temporary Personnel Setting
Parameters
4835 Enable Temporary Personnel Auto-audit: Yes No

Self-service Registration
First Name
QR Code URL: http://Server address:Port
Mike
Download QR code image

Last Name

Last Name

OK

Card Management OK

2. The users will be displayed in [Personnel] > [Temporary Personnel], click on


[Review] option and assign a department and click [OK] to successfully add the
user.
Welcome, admin

Personnel ID Name

The current query conditions None


Personnel
Refresh Review Delete
Person
Personnel ID First Name Last Name Mobile Phone Status Create Time Operations
Department

Temporary Personnel
4835 Mike Delete

Custom Attributes

Parameters

Card Management
1-1 50 rows per page Jump To 1 /0 Page Total of 0 records

10
Ethernet and Cloud Server Settings
Click on > [COMM.] > [Ethernet] to set the network parameters. If the TCP/IP
communication of the device is successful, the icon will be displayed in the
upper right corner of the standby interface.
Click on > [COMM.] > [Cloud Server Setting] to set the server address and server
port, that is, the IP address and port number of the server after the software is
installed. If the device communicates with the server successfully, the icon will be
displayed in the upper right corner of the standby interface.

Main Menu Ethernet Cloud Server Setting

IP Address 192.168.163.200 Server mode ADMS

L
User Mgt. User Role COMM. System Subnet Mask 255.255.255.0 Enable Domain Name

Gateway 192.168.163.1 Server Address 0.0.0.0

Personalize Data Mgt. Access Control Attendance DNS 0.0.0.0 Server port 8081
Search

TCP COMM. Port 4970 Enable Proxy Server

Autotest System Info


DHCP HTTPS

Display in Status Bar

Note:
While pairing the device with ZKBioAccess MTD software. Make sure that the option
Enable Domain Name is disabled and the correct server address and port are entered.
Server address: Set as the IP address of the ZKBioAccess MTD server.
Server port: Set as the service port of ZKBioAccess MTD (the default is 8088).

11
Access Control Setting
Click on > [Access Control] to enter the access control management interface and
set relevant parameters of access control.

Main Menu Access Control Access Control Options

Access Control Options Gate Control Mode

User Mgt. User Role COMM. System Time Rule setting Verification Mode Password/Face/Palm

Holidays Door available time period 1

Personalize Data Mgt.


L
Access Control Attendance
Search
Combined Verification

Anti-passback Setup
Normal open time period

Master Device
None

In

Autotest System Info Duress Options Auxiliary input configuration

Speaker Alarm

Reset Access Setting

Attendance Record
Click on > [Attendance Search] > [Attendance Record] to enter the records query
interface, input the user ID and select the time range, the corresponding attendance
logs will be displayed.

Main Menu Attendance Search Personal Record Search

Date User ID Access records


Event Logs Number of Records:04
03-03
4 11:25
User Mgt. User Role COMM. System Attendance Photo 2 11:2511:22
3 11:25
Blocklist ATT Photo 03-04 Number of Records:04
1 11:29
Personalize Data Mgt.
L
Access Control Attendance
Search
3
2
4
11:2911:21
11:28
11:26
03-05 Number of Records:04
1 11:27
Autotest System Info
4 11:27
3 11:27
2 11:27

12
Detection Management Settings
Click on > [System] > [Detection Management] to enter the setting interface.
❶ You can set the value of High temperature alarm threshold, and enable the
Temperature over the range; access denied and the Trigger external alarm, the
device will send an alarm prompt when the temperature of the user detected
exceeds this value, meanwhile the user will be forbidden to access, as shown in the
following figure. The method of enabling Mask detection is the same.

❷ When the Allow unregistered people to access is enabled, optionally, set Enable
capture of unregistered person to save the temperature data.

Main Menu System Detection Management

Date Time Enable temperature screening with infrared

L
User Mgt. User Role COMM. System Access Logs Setting High temperature alarm threshold 37.30 C
O

Face Temperature over the range; access denied

Personalize Data Mgt. Access Control Attendance Fingerprint 0.00


Search Temperature deviation correction

Palm Parameter Temp. Unit O


C

Autotest System Info


Reset Temperature measurement distance Far

Detection Management Display Thermodynamics Figure

Display Body Temperature

Enable mask detection

Deny access without mask

Allow unregistered people to access

Enable capture of unregistered person

Detection Management 08:50 08:50

Temp. Unit ℃

Temperature measurement distance Far


Normal temperature High body temperature
Temp.: 36.6 C O Temp.: 38.6 C O

Display Thermodynamics Figure

Display Body Temperature

Enable mask detection

Deny access without mask

Allow unregistered people to access

Enable capture of unregistered person

Trigger external alarm


Mask Detected Without mask

Clear external alarm

Successfully verified. Failed to verify.


Exter alarm delay(s) 255 Name:Mike Verify:Face
User ID:4835 User ID:4835
Verify:Face
Firmware update

13
Notes:
1. The effective distance for temperature detection is within 50cm.
2. Recommended for indoor use.

3. Temperature measurement data is for reference only, not for medical use.

4. Remove the mask to register the face, wear a mask to recognize the face, the type of
mask, the size of the face covered by the mask, and bangs will affect the facial recog-
nition effect.

5. Facial verification for masked individuals will increase FAR. Palm verification for
masked individuals is recommended.
Effective distance

Effective distance:
Temperature: 30-120cm
Palm: 30-50cm
Face: 0.3-2m

Real-time monitoring on the ZKBioAccess MTD software


Once ZKBioAccess MTD software installed, users could perform temperature detection
management on browser.

1. Please set the IP address and cloud service server address on the device and add the
device to the software.

2. Click [Temperature Detection] > [Temperature Management] > [Real-time moni-


toring] to view all the events include the Abnormal Temperature, No Masks and
Normal Records.

3. Click [Temperature Management] > [Statistics Panel] to view the analysis of statis-
tical data and view the personnels with normal temperature.

As shown in the following figure.

14
Real-Time Monitoring
Welcome, admin

2020-05-22 11:03:07
Real-Time Monitoring
Temperature Management

Real-Time Monitoring
Total: 0 0 0 0
Abnormal Temperature Normal Records
Statistics Panel

Temperature Raw Record


Name: UnregisterUser
Personnel Temperature
Schedule Department: NULL

Abnormal Temperature Record Temperature: 36.57℃


52.1oC Mask: Yes
Departmental body temperature
daily statistics report Mask: None
Time: 15:01:39
Name: (19961107)
Parameters Department: null
Time: 09:50:48
Name: UnregisterUser

Department: NULL
No Masks
Temperature: 36.57℃

Mask: Yes

Time: 15:01:39

Name: UnregisterUser
None None None None
Department: NULL
Temperature: 36.65℃ Temperature: 36.65℃ Temperature: 36.65℃ Temperature: 36.65℃
Name: UnregisterUser Name: UnregisterUser Name: UnregisterUser Name: UnregisterUser Temperature: 36.57℃
Department: NULL Department: NULL Department: NULL Department: NULL Mask: Yes
Time: 14:42:00 Time: 14:42:00 Time: 14:42:00 Time: 14:42:00 Time: 15:01:39

Statistics Panel
Welcome, admin

Statistics ViewNormal temperaturePeople

Time Today Personnel ID Department Name


Temperature Management
The current query conditions None The current query conditions None
Real-Time Monitoring
Refresh Refresh

Statistics Panel
Personnel ID First Name Department Department Name
Number
Temperature Raw Record
3 1 Sales
Personnel Temperature
Schedule 2 1 Sales
Abnormal Temperature Record

Departmental body temperature


daily statistics report Unmeasured body
temperature
Parameters

Temperature abnormal

Normal temperature Temperature abnormal


Unmeaured body temperature

1-2 50 rows per page Jump To 1 /1 Page

For more details, please refer to the ZKBioAccess MTD User Manual.

15
ZKTeco Industrial Park, No. 26, 188 Industrial Road,

Tangxia Town, Dongguan, China.

Phone : +86 769 - 82109991

Fax : +86 755 - 89602394

www.zkteco.com

Copyright © 2020 ZKTECO CO., LTD. All Rights Reserved.