You are on page 1of 29

TECHNICAL SUBMITTAL

PROJECT : Lusail Security Complex

LOCATION : Lusail City, Doha Qatar

CONTRACTOR : Al Aali International


INDEX
1. Mix Designs

2. Raw Materials Test Reports

3. Technical Data Sheets and Material Safety

Data Sheets
INDEX
1. Mix Designs
INDEX

2. Raw Material Test Reports


INDEX

3. Material Safety Data Sheets

and Technical Data Sheets


Technical Data

CIKOflow HY120
New generation low range concrete plasticizer

Description Applicable standards


CIKOflow HY120 is a low range water reducing  CIKOflow HY120 complies with ASTM C-494
super plasticizer based on modified type B, D and G.
polycarboxylic ether. It increases the dispersion  Comply with Qatar Construction Specification
of cement particles by electrostatic repulsion and QCS.
steric hindrance that enables the water content
in the concrete to perform to maximum efficiency Physical properties
accounting to lesser water-cement ratio with Form Liquid
improved workability. Clear, Light yellow or dark
Colour
Brown
CIKOflow HY120 is highly suitable for low water- Specific Gravity
0
1.05 + 0.02 at 25 C
cement concrete mixes maintaining higher
workability to produce high strength concrete. It Chloride Content Nil to BS 5075
exhibits prolonged workability retention Compatible with all types
Compatibility
especially in high ambient temperatures. of cement

Properties Dosage
 Better dispersion of cement particles The normal dosage is 0.5 to 3.0 litres per 100kg cement
with small adsorbed area. which includes replacements (if any) such as microsilica,
 Exhibits combined properties of high GGBFS, calcined clay (metakolin) and fly ash.
water reduction and prolonged
workability retention. The optimum dosage should be determined by
 Maintains concrete flowability over a conducting laboratory/site trials considering proposed
long time. mix design, ambient conditions and performance
 Provides high early compressive and requirements.
flexural strengths.
 Low water cement ratio yields to low Usage instructions
permeability. CIKOflow HY120 is a ready to use concrete admixture.
 Reduction in permeability, yielding to Required/calculated amount of CIKOflow HY120 should
increased durability. be measured by means of measuring jar or dispenser
and should be added to concrete during mixing process
Application area preferably after dispensing 70% of total water.
CIKOflow HY120 is suitable for all kinds of high To attain optimum efficiency of the admixture, it is
strength, high cement content and low water always recommended to dose CIKOflow HY120 to wet
cement ratio concrete. Typical application concrete mix. This can be done by mixing 70-75% of the
includes total water with all other ingredients of concrete followed
 Self compacting concrete by the addition of CIKOflow HY120 diluted with
 Hot weather concreting that demands remaining 25-30% water.
prolonged workability retention NOTE: CIKOflow HY120 should not be mixed with
 Precast concrete for early high strength. dry/lump concrete.
 More suitable for congested
reinforcement
 To avoid cold joints
 To obtain low heat of hydration

1
Compatibility with other admixtures Technical Support
CIKOflow HY120 should not be used in For any technical support, do not hesitate to contact
conjunction with any other admixtures. In case CIKO team at any time as CIKO offers on and off site
of such requirements please consult CIKO services to end users, specifier and contractors.
technical service department for assistance.

More from CIKO Middle East


Packaging A wide range of construction chemical products are
CIKOflow HY120 is available in 200 litre drums manufactured by CIKO Middle East which includes:
and in 1000litre tank.  Concrete admixtures and additives
 Waterproofing and damp proof coatings
Shelf Life  Surface treatments
CIKOflow HY120 has a minimum shelf life of 12  Flooring and toppings
months if stored in accordance with CIKO  Grouts and anchors
instructions.
 Tile adhesives and grout
 Concrete repair materials
Storage
CIKOflow HY120 should be stored under  Adhesives and bonding agent
enclosed shaded are.  Protective coating
 Joint Sealants and Moulding compounds
Precautions  Ancillaries
 Dosage shall not be more than the
maximum limit

Effect of over dosage:


Over dosage to the extent of double the
recommended dosage of CIKOflow HY120 will
result in delayed setting time and increased
workability.

Health & Safety


CIKOflow HY120 should not come in contact
with eyes or to be swallowed. If comes in
contact with eyes, flush with plenty of fresh
water and seek medical advice.
CIKOflow HY120 is water based material and
non-flammable.

Refer Material Safety Data Sheet for further


details.

TDS/AD20 Rev.:3 Issue:C


Note: The information presented herein based on the best of our knowledge and expertise for which every effort is made to ensure its
reliability. Although all the products are subjected to rigid quality tests and are guaranteed against defective materials and manufacture,
no specific guarantee can be extended because results depend not only on quality but also on other factors beyond our control
MATERIAL SAFETY DATA SHEET
Name of Product : CIKOflow HY120

1. CHEMICAL PRODUCT AND COMPANY INFORMATION


Product name CIKOflow HY120
Manufacturer CIKO Middle East
Address P.O.Box: 295, Doha-Qatar
Emergency Telephone (974) 4411 4787 / 4411 4790
Product use Hyperplasticizer for concrete
Date March 2018
2. COMPOSITION / INFORMATION ON INGREDIENTS
Ingredients
NAME CAS NO. PROPORTION
Polycarboxylic salt
221881-27-2 30-50%
surfactant
Water 7732-18-5 50-70%

3. HAZARDS IDENTIFICATION
Physical hazards N.E.
Primary route of exposure Skin contact
Effects of acute / chronic
exposure
Skin contact Possible mild transient irritation on prolonged contact
Eye contact May cause temporary irritation
Inhalation Over exposure to mist may cause irritation of the respiratory tract
Ingestion Very slightly toxic. May cause G.I irritation, nausea and cramps.
4. FIRST AID MEASURES
Skin contact Wash thoroughly with soap and water. If any irritation develops, seek
immediate medical attention.
Eye contact Flush with plenty of fresh water and se ek immediate medical
attention.
Inhalation Remove to fresh air.

Ingestion Administer milk or water. Do not induce vomiting. Call the physician
or Poison Control Centre immediately. Do not give anything orally to
an unco nscious person. This applies to al l pr oducts that w ill not
require vomiting to be induced, however, medical attention or
consultation is to be sought immediately.
5. FIRE FIGHTING MEASURES
Conditions of flammability None
Means of extinction None
Flash point & means of
determination None
Upper flammable limit None

MSDS/AD07 Rev.:01 Issue:A 1 of 3


Lower flammable limit None
Auto-ignition temperature None
Hazardous combustion
products None
Explosion data None
Sensitivity to
mechanical impact None
Sensitivity to
static discharge None

6. ACCIDENTAL RELEASE MEASURES


Spillage measures Small sp ills of up t o 2 g allons may be so aked up with a g ood
absorbent and di sposed o ff i n a l andfill. The ar ea i s to be w ashed
thoroughly. Contact the local sewer authority for effects on sewage
treatment facility.
7. HANDLING AND STORAGE
Storage conditions Do not freeze. Do not contaminate with other chemicals as this will cause to
resin to agglomerate and clog the equipment.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Exposure controls All chemicals are to be handled in such a manner so as to prevent
eye contact and excessive or prolonged skin contact. Use of
appropriate eye and skin protection gear is advised. Excessive
inhalation of dust and vapours is also to be avoided.
Personal protection

Ventilation Fresh air supply

Respirator None

Eye protection Yes

Protective gear Rubberized gloves

Other -
9. PHYSICAL AND CHEMICAL PROPERTIES
Physical state Liquid
Odour and appearance Slightly ammoniac / Yellowish liquid
Odour threshold N.A.
Specific gravity 1.05 + 0.015
Vapour pressure N.A.
Vapour density N.A.
Evaporation rate N.A.
Boiling point N.A.
Freezing point N.A.
Melting point N.A.
pH 8.0

MSDS/AD07 Rev.:01 Issue:A 2 of 3


Coefficient of water/oil
distribution N.A.
10. STABILITY AND REACTIVITY
Conditions causing
instability None

Incompatible materials Do not mix with other concrete admixtures as they may gel

Conditions of reactivity

Hazardous decomposition
products None
11. TOXICOLOGICAL INFORMATION
Toxicology information N.A.
Skin contact Possible mild transient irritation on prolonged contact
Eye contact May cause temporary irritation
Inhalation Over exposure to mist may cause irritation of the respiratory tract
Ingestion Very slightly toxic. May cause G.I irritation, nausea and cramps.
12. ECOLOGICAL INFORMATION
Ecological information N.A.
13. DISPOSAL CONSIDERATIONS
Waste disposal In the event of large spills at ready-mix plants, either flush into the
wash-out pit, or dike and contain. Contained material may be
absorbed and disposed of, or allowed to evaporate and the solids
disposed of in a trash container.

14. TRANSPORT INFORMATION


DOT shipping name N.E.
Technical shipping
name Hyperplasticizer for concrete
DOT hazard
classification
Primary N.E.
Secondary N.E.
Freight classification Class 55
UN number N.E.
IMO hazard class N.A.
DOT labels N.A.
EPA/DOT hazardous
substance rq N.A.
15. OTHER INFORMATION
Contact person/point Technical Department: (974) 4411 4787 / 4411 4790
History MSDS Creation: March 2018
. . . End of MSDS. . .

MSDS/AD07 Rev.:01 Issue:A 3 of 3