Professional Documents
Culture Documents
A0 Merged
A0 Merged
C. Y. 2022 PROJECT
DETAILED ENGINEERING DESIGN PLAN FOR
CONSTRUCTION/ REHABILITATION OF WATER SUPPLY/ SEPTAGE &
SEWERAGE/ RAINWATER COLLECTOR SYSTEM- RAINWATER
COLLECTOR IN PUBLIC FACILITIES
CLUSTER -1
a. DUPAX DEL NORTE NHS-SENIOR HIGH, BRGY. LAMO, DUPAX DEL NORTE, NUEVA VIZCAYA
b. INEANGAN BRGY. HALL, BRGY. INEANGAN, DUPAX DEL NORTE, NUEVA VIZCAYA
c. DUPAX DEL NORTE NHS POBLACION ANNEX, BRGY. MALASIN, DUPAX DEL NORTE, NUEVA VIZCAYA
d. DUPAX DEL NORTE CENTRAL SCHOOL, BRGY. MALASIN, DUPAX DEL NORTE, NUEVA VIZCAYA
e. MALASIN BRGY. HALL, BRGY. MALASIN, DUPAX DEL NORTE, NUEVA VIZCAYA
f. INABAN ELEMENTARY SCHOOL, BRGY. INABAN, DUPAX DEL NORTE ,NUEVA VIZCAYA
g. DUPAX DEL SUR MHO, BRGY. DOPAJ, DUPAX DEL SUR, NUEVA VIZCAYA
h. BRGY. DOMANG COVERED COURT, BRGY. DOMANG, DUPAX DEL SUR, NUEVA VIZCAYA
i. DUPAX DEL SUR CENTRAL SCHOOL, DUPAX DEL SUR, NUEVA VIZCAYA
j. PALABOTAN ELEMENTARY SCHOOL,BRGY. PALABOTAN, DUPAX DEL SUR, NUEVA VIZCAYA
k. PALABOTAN BRGY. RHU, BRGY. PALABOTAN, NUEVA VIZCAYA
l. MANGAYANG ELEMENTARY SCHOOL, BRGY. MANGAYANG, DUPAX DEL SUR, NUEVA VIZCAYA
m.SITIO TANIBONG - MANGAYANG COVERED COURT, BRGY. MANGAYANG, DUPAX DEL SUR, NUEVA VIZCAYA
C. Y. 2022 PROJECT
DETAILED ENGINEERING DESIGN PLAN FOR
CONSTRUCTION/ REHABILITATION OF WATER SUPPLY/ SEPTAGE &
SEWERAGE/ RAINWATER COLLECTOR SYSTEM- RAINWATER
COLLECTOR IN PUBLIC FACILITIES
a. DUPAX DEL NORTE NHS- SENIOR HIGH, BRGY. LAMO,
DUPAX DEL NORTE, NUEVA VIZCAYA
APPROVED:
SUBMITTED: RECOMMENDED:
04
PERSPECTIVE
A 02 PROJECT LOCATION MAP
04 SUMMARY OF QUANTITIES
VICINITY MAP
SITE DEVELOPMENT PLAN
INDEX OF DRAWINGS
ISOMETRIC VIEW OF HOR. RAINWATER TANK
A 03 DETAILED PLAN OF STAINLESS STEEL HOR.
04 RAINWATER TANK
JCT. NAT'L-BIT-BEL-NV
Dine
A
Pacquet
LIK
AR
Latar Del Sur Bua
AH
Bone N.
M
Muta
G
AN
DA
Calitlitan Bone S. ARITAO-QUI
RINO RD.
RD.
Mag asawang Yaway Mantata
Salacsac kahoy Macabenga Macate
Anayo
NV-P
Malico
Consuelo Balite Santa Clara
ANGA
SINA Santa Fe
N RD Villaflores Baliti
Baracbac
.
Canarem Belance
Imugan Mangauit
Canabuan
1 PERSPECTIVE Tactac
Dalton
Binuangan Yabbi
Abaca
New Gumiad
Umubi
Pelaway
3 KEY LOCATION MAP
Lipuga
Gadeng
A 2 SCALE: Nts.
Taan
Cauayan
ITEM QUANTITY
DESCRIPTION UNIT
NO. Alfonso
Castaneda
PART I. FACILITIES FOR THE ENGINEER Lublub
Marikit
A.1.4 (1) Provisions of Progress Photographs 0.33 Months PAN-CANILI-BASAL-BALER RD.
ROAD
803 (1)a Structure Excavation 0.80 cu.m
3 ST
ORE
804 (4) Gravel Fill 0.80 cu.m WAL
Y SC
HOO
K WAY L BL
DG.
PART B. PLAIN AND REINFORCED CONCRETE WORKS
900 (1)b1 Structural Concrete (Class A, 14 Days) 1.20 cu.m
PART D. PLUMBING/SANITARY WORKS 2 VICINITY MAP
1001 (9) Strom Drinage and Downspout 1.00 L.S. A 2 SCALE: Nts.
4 SITE DEVELOPMENT PLAN
A 2 SCALE: Nts.
1002 (27) Plumbing Fixtures 1.00 L.S.
PROJECT NAME AND LOCATION: SHEET CONTENTS: PREPARED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO: SHEET NO:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS C. Y. 2022 PROJECT PERSPECTIVE RHUELLE VALENTIN T. JANER
REGIONAL OFFICE II DETAILED ENGINEERING DESIGN PLAN FOR PROJECT LOCATION MAP ARCHITECT II
NUEVA VIZCAYA CONSTRUCTION/ REHABILITATION OF WATER SUPPLY/ A 2
SUMMARY OF QUANTITIES REYNALDO V. RAGASA, JR. EDISON C. BASILIO PERFECTO E. URBAN, JR. MARLYN G. INGUILLO
SEPTAGE & SEWERAGE/ RAINWATER COLLECTOR SYSTEM DESIGNED:
2ND DISTRICT ENGINEERING OFFICE VICINITY MAP ENGINEER II OIC, PLANNING AND DESIGN ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
- RAINWATER COLLECTOR IN PUBLIC FACILITIES 2 4 4
DUPAX DEL NORTE, NUEVA VIZCAYA a.DUPAX DEL NORTE NHS-SENIOR HIGH, BRGY. LAMO,
SITE DEVELOPMENT PLAN JIOVANNI RUPAC - DANGAN SECTION
DUPAX DEL NORTE, NUEVA VIZCAYA INDEX OF DRAWINGS ENGINEER II (CTO BBBP) DATE: DATE: DATE: DATE:
NOTES:
2000
PVC BLUE PIPE, Ø20mm - MAIN TO HOSE BIBB
PVC PIPE, Ø100mm, S-1000
STAINLESS STEEL STORAGE TANK (HORIZONTAL)
FIRST FLUSH DIVERTER W/ STAINLESS STEEL(SS) LADDER ( 1.70mØ - 3m
(DOWNPIPE-TYPE) LONG ) ( Volume of Tank = 6,809 liters )
PROVIDE GI PVC PIPE CLAMP. VARIES 4000 2m x 4m x 0.15m Thk. PLAIN CONCRETE SLAB
PROJECT NAME AND LOCATION: SHEET CONTENTS: PREPARED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO: SHEET NO:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS C. Y. 2022 PROJECT RHUELLE VALENTIN T. JANER
REGIONAL OFFICE II DETAILED ENGINEERING DESIGN PLAN FOR ARCHITECT II
NUEVA VIZCAYA CONSTRUCTION/ REHABILITATION OF WATER SUPPLY/ ISOMETRIC VIEW OF HOR. RAINWATER TANK A 3
SEPTAGE & SEWERAGE/ RAINWATER COLLECTOR SYSTEM DETAILED PLAN OF STAINLESS STEEL HOR. DESIGNED: REYNALDO V. RAGASA, JR. EDISON C. BASILIO PERFECTO E. URBAN, JR. MARLYN G. INGUILLO
2ND DISTRICT ENGINEERING OFFICE - RAINWATER COLLECTOR IN PUBLIC FACILITIES RAINWATER TANK ENGINEER II OIC, PLANNING AND DESIGN ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
DUPAX DEL NORTE, NUEVA VIZCAYA JIOVANNI RUPAC - DANGAN SECTION 3 4 4
a.DUPAX DEL NORTE NHS-SENIOR HIGH, BRGY. LAMO,
DUPAX DEL NORTE, NUEVA VIZCAYA ENGINEER II (CTO BBBP) DATE: DATE: DATE: DATE:
RAIN HEAD, SLOPED NOTES:
SCREEN DIVERTS DEBRIS.
1. TANK SHOULD BE FIRM, FLAT & ON STABLE PLATFORM IN ACCORDANCE
PVC PIPE, Ø100mm, S-1000.
SECOND FINER SCREEN WITH MANUFACTURER'S RECOMMENDATIONS. TANK BASE UNIT MUST BE
TANK ACCESS. SUFFICIENT TO SUPPORT WEIGHT OF TANK WHEN FULL.
PREVENTS INSECTS FROM
GETTING INTO TANK. AIR RELIEF VENT
w/ INSECT SCREEN. 2. 100% OF ROOF AREA SHALL DRAIN TO THE TANK.
FIRST FLUSH DIVERTER
(DOWNPIPE-TYPE) OVERFLOW PIPE w/ LOUVERED
3. IT IS RECOMMENDED TO CONNECT THE FOLLOWING HOUSEHOLD
OUTLET FOR INSECT
SLOW-DRIP FLOW FIXTURES TO THE RAINWATER TANK SUPPLY:
PREVENTION (100mm).
- ALL OUTDOOR TAPS
CONTROL VALVE
NON-POTABLE WATER TO - ALL TOILETS
HOSE BIBB. - WASHING MACHINE (COLD TAP)
PVC BLUE PIPE, Ø50mm - FOR MAIN LINE
4. ALL PLUMBING WORKS SHALL BE UNDERTAKEN BY A LICENSED PLUMBER
STAINLESS STEEL STORAGE PVC BLUE PIPE, Ø20mm - MAIN TO HOSE BIBB
WITH THE CONSENT OF THE MANUFACTURER & IN ACCORDANCE WITH ALL
TANK (HORIZONTAL) W/ PVC PIPE, Ø100mm, S-1000 STANDARDS, CODES & REGULATIONS.
STAINLESS STEEL(SS)
LADDER ( 1.70mØ - 3m 2m x 4m x 0.15m Thk. PLAIN CONCRETE SLAB 5. TANK & PUMP SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S
LONG ) ( Volume of Tank = REQUIREMENTS.
6,809 liters )
1 DETAILED ISOMETRIC SECTION OF STAINLESS STEEL HOR. RAINWATER TANK
6. ANNUAL RAINFALL = 4464.90mm (ACCORDING TO THE HIGHEST
A 4 SCALE: Nts.
CLIMATOLOGICAL NORMAL RECORDED BY THE PHILIPPINE ATMOSPHERIC,
GEOPHYSICAL AND ASTRONOMICAL SERVICES ADMINISTRATION (PAGASA).
ALL TYPE OF ROOFING ACCEPTABLE.
PRE-PAINTED GUTTER (GA. 24) w/ SCREEN ON TOP.
PVC PIPE, Ø75mm, S-1000 (COLLECTOR PIPE FROM GUTTER)
RAIN HEAD, SLOPED
SCREEN DIVERTS DEBRIS.
PVC PIPE, Ø100mm, S-1000.
2'' GAP AT DOWNSPOUT.
TANK ACCESS.
SECOND FINER SCREEN AIR RELIEF VENT
PREVENTS INSECTS FROM w/ INSECT SCREEN.
GETTING INTO TANK.
STAINLESS STEEL STORAGE OVERFLOW PIPE w/ LOUVERED
TANK (HORIZONTAL) W/ OUTLET FOR INSECT PREVENTION (100mm).
STAINLESS STEEL(SS) LADDER NON-POTABLE WATER TO
FIRST FLUSH DIVERTER ( 1.70mØ - 3m LONG ) ( Volume of HOSE BIBB.
(DOWNPIPE-TYPE) Tank = 6,809 liters )
PVC BLUE PIPE, Ø50mm - FOR MAIN LINE
SLOW-DRIP FLOW PVC BLUE PIPE, Ø20mm - MAIN TO HOSE BIBB
100
150
ANGLE BARS
50
100mm Thk. GRAVEL FILL
100
(DIMENSIONS AND SIZES VARIES 4000 2m x 4m x 0.15m Thk. PLAIN CONCRETE SLAB
ARE BASED ON
MANUFACTURER'S
DETAILS) 2 DETAILED ELEVATION OF STAINLESS STEEL HOR. RAINWATER TANK
A 4 SCALE: 1: 50 Mts.
PROJECT NAME AND LOCATION: SHEET CONTENTS: PREPARED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO: SHEET NO:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS C. Y. 2022 PROJECT RHUELLE VALENTIN T. JANER
REGIONAL OFFICE II DETAILED ENGINEERING DESIGN PLAN FOR DETAILED ISOMETRIC SECTION OF STAINLESS ARCHITECT II
NUEVA VIZCAYA CONSTRUCTION/ REHABILITATION OF WATER SUPPLY/ A 4
STEEL HOR. RAINWATER TANK REYNALDO V. RAGASA, JR. EDISON C. BASILIO PERFECTO E. URBAN, JR. MARLYN G. INGUILLO
SEPTAGE & SEWERAGE/ RAINWATER COLLECTOR SYSTEM DESIGNED:
2ND DISTRICT ENGINEERING OFFICE DETAILED ELEVATION OF STAINLESS STEEL ENGINEER II OIC, PLANNING AND DESIGN ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
- RAINWATER COLLECTOR IN PUBLIC FACILITIES 4 4 4
DUPAX DEL NORTE, NUEVA VIZCAYA a.DUPAX DEL NORTE NHS-SENIOR HIGH, BRGY. LAMO,
HOR. RAINWATER TANK JIOVANNI RUPAC - DANGAN SECTION
DUPAX DEL NORTE, NUEVA VIZCAYA ENGINEER II (CTO BBBP) DATE: DATE: DATE: DATE:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
REGIONAL OFFICE II
NUEVA VIZCAYA 2ND DISTRICT ENGINEERING OFFICE
DUPAX DEL NORTE, NUEVA VIZCAYA
C. Y. 2022 PROJECT
DETAILED ENGINEERING DESIGN PLAN FOR
CONSTRUCTION/ REHABILITATION OF WATER SUPPLY/ SEPTAGE &
SEWERAGE/ RAINWATER COLLECTOR SYSTEM- RAINWATER
COLLECTOR IN PUBLIC FACILITIES
b. INEANGAN BRGY.HALL, BRGY. INEANGAN,
DUPAX DEL NORTE,NUEVA VIZCAYA
APPROVED:
SUBMITTED: RECOMMENDED:
04
PERSPECTIVE
A 02 PROJECT LOCATION MAP
04 SUMMARY OF QUANTITIES
VICINITY MAP
SITE DEVELOPMENT PLAN
INDEX OF DRAWINGS
ISOMETRIC VIEW OF HOR. RAINWATER TANK
A 03 DETAILED PLAN OF STAINLESS STEEL HOR.
04 RAINWATER TANK
JCT. NAT'L-BIT-BEL-NV
Dine
A
Pacquet
LIK
AR
Latar Del Sur Bua
AH
Bone N.
M
Muta
G
AN
DA
Calitlitan Bone S. ARITAO-QUI
RINO RD.
RD.
Mag asawang Yaway Mantata
Salacsac kahoy Macabenga Macate
Anayo
Malico
Consuelo Balite Santa Clara
PERSPECTIVE
NV-P
ANGA
SINA Santa Fe
N RD Villaflores Baliti
1 Canarem Belance
.
Baracbac Mangauit
Imugan
Canabuan
Tactac Binuangan Yabbi
A 2 SCALE: Nts. Dalton
NORTH
SUMMARY OF QUANTITIES Abaca
New Gumiad
Umubi
Pelaway
ITEM Lipuga
NO.
DESCRIPTION QUANTITY UNIT Gadeng
Taan
Cauayan
3 KEY LOCATION MAP
Sitio Dinep A 2 SCALE: Nts.
PART I. FACILITIES FOR THE ENGINEER
Abuyo
B.7 (1) Occupational Safety and Health Program (PPE, Safety Personnel and Signage) 0.33 Months
B.9 Mobilization/Demobilization 1.00 L.S.
PART III. CIVIL, MECHANICAL, ELECTRICAL AND SANITARY/PLUMBING WORKS
PART A. EARTHWORKS
803 (1)a Structure Excavation 0.80 cu.m BRGY.
804 (4) Gravel Fill 0.80 cu.m INEANGAN COVERED
HALL
PART B. PLAIN AND REINFORCED CONCRETE WORKS COURT
INEANGAN COVERED
900 (1)b1 Structural Concrete (Class A, 14 Days) 1.20 cu.m COURT
PART C. FINISHING
AD
INSTALLATION OF GI
GUTTER(REFER TO
C.6 ROOF FRAMING AND ROOFING WORKS SUMMARY OF
RO
QUANTITIES)
1013 (2)b1 Fabricated Metal Roofing Accessory - Gutters 8.00 ln.m
PART D. PLUMBING/SANITARY WORKS SITE DEVELOPMENT PLAN
1001 (9) Strom Drinage and Downspout 1.00 L.S.
2 VICINITY MAP 4
A 2 SCALE: Nts.
A 2 SCALE: Nts.
1002 (27) Plumbing Fixtures 1.00 L.S.
PROJECT NAME AND LOCATION: SHEET CONTENTS: PREPARED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO: SHEET NO:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS C. Y. 2022 PROJECT PERSPECTIVE RHUELLE VALENTIN T. JANER
REGIONAL OFFICE II DETAILED ENGINEERING DESIGN PLAN FOR PROJECT LOCATION MAP ARCHITECT II
NUEVA VIZCAYA CONSTRUCTION/ REHABILITATION OF WATER SUPPLY/ A 2
SUMMARY OF QUANTITIES REYNALDO V. RAGASA, JR. EDISON C. BASILIO PERFECTO E. URBAN, JR. MARLYN G. INGUILLO
SEPTAGE & SEWERAGE/ RAINWATER COLLECTOR SYSTEM DESIGNED:
2ND DISTRICT ENGINEERING OFFICE VICINITY MAP ENGINEER II OIC, PLANNING AND DESIGN ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
- RAINWATER COLLECTOR IN PUBLIC FACILITIES 2 4 4
DUPAX DEL NORTE, NUEVA VIZCAYA b. INEANGAN BRGY. HALL, BRGY. INEANGAN, SITE DEVELOPMENT PLAN JIOVANNI RUPAC - DANGAN SECTION
DUPAX DEL NORTE, NUEVA VIZCAYA INDEX OF DRAWINGS ENGINEER II (CTO BBBP) DATE: DATE: DATE: DATE:
NOTES:
2000
PVC BLUE PIPE, Ø20mm - MAIN TO HOSE BIBB
PVC PIPE, Ø100mm, S-1000
STAINLESS STEEL STORAGE TANK (HORIZONTAL)
FIRST FLUSH DIVERTER W/ STAINLESS STEEL(SS) LADDER ( 1.70mØ - 3m
(DOWNPIPE-TYPE) LONG ) ( Volume of Tank = 6,809 liters )
PROVIDE GI PVC PIPE CLAMP. VARIES 4000 2m x 4m x 0.15m Thk. PLAIN CONCRETE SLAB
PROJECT NAME AND LOCATION: SHEET CONTENTS: PREPARED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO: SHEET NO:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS C. Y. 2022 PROJECT RHUELLE VALENTIN T. JANER
REGIONAL OFFICE II DETAILED ENGINEERING DESIGN PLAN FOR ARCHITECT II
NUEVA VIZCAYA CONSTRUCTION/ REHABILITATION OF WATER SUPPLY/ ISOMETRIC VIEW OF HOR. RAINWATER TANK A 3
SEPTAGE & SEWERAGE/ RAINWATER COLLECTOR SYSTEM DETAILED PLAN OF STAINLESS STEEL HOR. DESIGNED: REYNALDO V. RAGASA, JR. EDISON C. BASILIO PERFECTO E. URBAN, JR. MARLYN G. INGUILLO
2ND DISTRICT ENGINEERING OFFICE - RAINWATER COLLECTOR IN PUBLIC FACILITIES RAINWATER TANK ENGINEER II OIC, PLANNING AND DESIGN ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
DUPAX DEL NORTE, NUEVA VIZCAYA b. INEANGAN BRGY. HALL, BRGY. INEANGAN, JIOVANNI RUPAC - DANGAN SECTION 3 4 4
DUPAX DEL NORTE, NUEVA VIZCAYA ENGINEER II (CTO BBBP) DATE: DATE: DATE: DATE:
RAIN HEAD, SLOPED NOTES:
SCREEN DIVERTS DEBRIS.
1. TANK SHOULD BE FIRM, FLAT & ON STABLE PLATFORM IN ACCORDANCE
PVC PIPE, Ø100mm, S-1000.
SECOND FINER SCREEN WITH MANUFACTURER'S RECOMMENDATIONS. TANK BASE UNIT MUST BE
TANK ACCESS. SUFFICIENT TO SUPPORT WEIGHT OF TANK WHEN FULL.
PREVENTS INSECTS FROM
GETTING INTO TANK. AIR RELIEF VENT
w/ INSECT SCREEN. 2. 100% OF ROOF AREA SHALL DRAIN TO THE TANK.
FIRST FLUSH DIVERTER
(DOWNPIPE-TYPE) OVERFLOW PIPE w/ LOUVERED
3. IT IS RECOMMENDED TO CONNECT THE FOLLOWING HOUSEHOLD
OUTLET FOR INSECT
SLOW-DRIP FLOW FIXTURES TO THE RAINWATER TANK SUPPLY:
PREVENTION (100mm).
- ALL OUTDOOR TAPS
CONTROL VALVE
NON-POTABLE WATER TO - ALL TOILETS
HOSE BIBB. - WASHING MACHINE (COLD TAP)
PVC BLUE PIPE, Ø50mm - FOR MAIN LINE
4. ALL PLUMBING WORKS SHALL BE UNDERTAKEN BY A LICENSED PLUMBER
STAINLESS STEEL STORAGE PVC BLUE PIPE, Ø20mm - MAIN TO HOSE BIBB
WITH THE CONSENT OF THE MANUFACTURER & IN ACCORDANCE WITH ALL
TANK (HORIZONTAL) W/ PVC PIPE, Ø100mm, S-1000 STANDARDS, CODES & REGULATIONS.
STAINLESS STEEL(SS)
LADDER ( 1.70mØ - 3m 2m x 4m x 0.15m Thk. PLAIN CONCRETE SLAB 5. TANK & PUMP SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S
LONG ) ( Volume of Tank = REQUIREMENTS.
6,809 liters )
1 DETAILED ISOMETRIC SECTION OF STAINLESS STEEL HOR. RAINWATER TANK 6. ANNUAL RAINFALL = 4464.90mm (ACCORDING TO THE HIGHEST
A 4 SCALE: Nts.
CLIMATOLOGICAL NORMAL RECORDED BY THE PHILIPPINE ATMOSPHERIC,
GEOPHYSICAL AND ASTRONOMICAL SERVICES ADMINISTRATION (PAGASA).
ALL TYPE OF ROOFING ACCEPTABLE.
PRE-PAINTED GUTTER (GA. 24) w/ SCREEN ON TOP.
PVC PIPE, Ø75mm, S-1000 (COLLECTOR PIPE FROM GUTTER)
RAIN HEAD, SLOPED
SCREEN DIVERTS DEBRIS.
PVC PIPE, Ø100mm, S-1000.
2'' GAP AT DOWNSPOUT.
TANK ACCESS.
SECOND FINER SCREEN AIR RELIEF VENT
PREVENTS INSECTS FROM w/ INSECT SCREEN.
GETTING INTO TANK.
STAINLESS STEEL STORAGE OVERFLOW PIPE w/ LOUVERED
TANK (HORIZONTAL) W/ OUTLET FOR INSECT PREVENTION (100mm).
STAINLESS STEEL(SS) LADDER NON-POTABLE WATER TO
FIRST FLUSH DIVERTER ( 1.70mØ - 3m LONG ) ( Volume of HOSE BIBB.
(DOWNPIPE-TYPE) Tank = 6,809 liters )
PVC BLUE PIPE, Ø50mm - FOR MAIN LINE
SLOW-DRIP FLOW PVC BLUE PIPE, Ø20mm - MAIN TO HOSE BIBB
100
150
(DIMENSIONS AND SIZES VARIES 4000 2m x 4m x 0.15m Thk. PLAIN CONCRETE SLAB
ARE BASED ON
MANUFACTURER'S
DETAILS)
2 DETAILED ELEVATION OF STAINLESS STEEL HOR. RAINWATER TANK
A 4 SCALE: 1: 50 Mts.
PROJECT NAME AND LOCATION: SHEET CONTENTS: PREPARED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO: SHEET NO:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS C. Y. 2022 PROJECT RHUELLE VALENTIN T. JANER
REGIONAL OFFICE II DETAILED ENGINEERING DESIGN PLAN FOR DETAILED ISOMETRIC SECTION OF STAINLESS ARCHITECT II
NUEVA VIZCAYA CONSTRUCTION/ REHABILITATION OF WATER SUPPLY/ A 4
STEEL HOR. RAINWATER TANK REYNALDO V. RAGASA, JR. EDISON C. BASILIO PERFECTO E. URBAN, JR. MARLYN G. INGUILLO
SEPTAGE & SEWERAGE/ RAINWATER COLLECTOR SYSTEM DESIGNED:
2ND DISTRICT ENGINEERING OFFICE DETAILED ELEVATION OF STAINLESS STEEL ENGINEER II OIC, PLANNING AND DESIGN ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
- RAINWATER COLLECTOR IN PUBLIC FACILITIES 4 4 4
DUPAX DEL NORTE, NUEVA VIZCAYA b. INEANGAN BRGY. HALL, BRGY. INEANGAN,
HOR. RAINWATER TANK JIOVANNI RUPAC - DANGAN SECTION
DUPAX DEL NORTE, NUEVA VIZCAYA ENGINEER II (CTO BBBP) DATE: DATE: DATE: DATE:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
REGIONAL OFFICE II
NUEVA VIZCAYA 2ND DISTRICT ENGINEERING OFFICE
DUPAX DEL NORTE, NUEVA VIZCAYA
C. Y. 2022 PROJECT
DETAILED ENGINEERING DESIGN PLAN FOR
CONSTRUCTION/ REHABILITATION OF WATER SUPPLY/ SEPTAGE &
SEWERAGE/ RAINWATER COLLECTOR SYSTEM- RAINWATER
COLLECTOR IN PUBLIC FACILITIES
c. DUPAX DEL NORTE NHS POBLACION ANNEX,
BRGY. MALASIN, DUPAX DEL NORTE, NUEVA VIZCAYA
APPROVED:
SUBMITTED: RECOMMENDED:
04
PERSPECTIVE
A 02 PROJECT LOCATION MAP
04 SUMMARY OF QUANTITIES
VICINITY MAP
SITE DEVELOPMENT PLAN
INDEX OF DRAWINGS
ISOMETRIC VIEW OF HOR. RAINWATER TANK
A 03 DETAILED PLAN OF STAINLESS STEEL HOR.
04 RAINWATER TANK
JCT. NAT'L-BIT-BEL-NV
Dine
A
Pacquet
LIK
AR
Latar Del Sur Bua
AH
Bone N.
M
Muta
G
AN
DA
Calitlitan Bone S. ARITAO-QUI
RINO RD.
RD.
Mag asawang Yaway Mantata
Salacsac kahoy Macabenga Macate
Anayo
NV-P
Malico
Consuelo Balite Santa Clara
ANGA
SINA Santa Fe
N RD Villaflores Baliti
Baracbac
.
Canarem Belance
Imugan Mangauit
Canabuan
1 PERSPECTIVE Tactac
Dalton
Binuangan Yabbi
Abaca Umubi
Lipuga
Pelaway
Gadeng
Taan
3 KEY LOCATION MAP
Cauayan
A 2 SCALE: Nts.
ITEM QUANTITY
DESCRIPTION UNIT
NO. Alfonso
Castaneda
3- S
TOR
BR
B.7 (1) Occupational Safety and Health Program (PPE, Safety Personnel and Signage) 0.33 Months
GY
EY
.R
SCH
B.9 Mobilization/Demobilization 1.00 L.S.
OA
OO
D
LB
PART III. CIVIL, MECHANICAL, ELECTRICAL AND SANITARY/PLUMBING WORKS
LDG
.
PART A. EARTHWORKS
803 (1)a Structure Excavation 0.80 cu.m
804 (4) Gravel Fill 0.80 cu.m
3.00m
PART B. PLAIN AND REINFORCED CONCRETE WORKS
900 (1)b1 Structural Concrete (Class A, 14 Days) 1.20 cu.m
PART D. PLUMBING/SANITARY WORKS
1001 (9) Strom Drinage and Downspout 1.00 L.S. 2 VICINITY MAP 4 SITE DEVELOPMENT PLAN
A 2 SCALE: Nts. A 2 SCALE: Nts.
1002 (27) Plumbing Fixtures 1.00 L.S.
PROJECT NAME AND LOCATION: SHEET CONTENTS: PREPARED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO: SHEET NO:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS C. Y. 2022 PROJECT PERSPECTIVE RHUELLE VALENTIN T. JANER
REGIONAL OFFICE II DETAILED ENGINEERING DESIGN PLAN FOR PROJECT LOCATION MAP ARCHITECT II
NUEVA VIZCAYA CONSTRUCTION/ REHABILITATION OF WATER SUPPLY/ A 2
SUMMARY OF QUANTITIES REYNALDO V. RAGASA, JR. EDISON C. BASILIO PERFECTO E. URBAN, JR. MARLYN G. INGUILLO
SEPTAGE & SEWERAGE/ RAINWATER COLLECTOR SYSTEM DESIGNED:
2ND DISTRICT ENGINEERING OFFICE VICINITY MAP ENGINEER II OIC, PLANNING AND DESIGN ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
- RAINWATER COLLECTOR IN PUBLIC FACILITIES 2 4 4
DUPAX DEL NORTE, NUEVA VIZCAYA c. DUPAX DEL NORTE NHS POBLACION ANNEX, BRGY. MALASIN, SITE DEVELOPMENT PLAN JIOVANNI RUPAC - DANGAN SECTION
DUPAX DEL NORTE, NUEVA VIZCAYA INDEX OF DRAWINGS ENGINEER II (CTO BBBP) DATE: DATE: DATE: DATE:
NOTES:
2000
PVC BLUE PIPE, Ø20mm - MAIN TO HOSE BIBB
PVC PIPE, Ø100mm, S-1000
STAINLESS STEEL STORAGE TANK (HORIZONTAL)
FIRST FLUSH DIVERTER W/ STAINLESS STEEL(SS) LADDER ( 1.70mØ - 3m
(DOWNPIPE-TYPE) LONG ) ( Volume of Tank = 6,809 liters )
PROVIDE GI PVC PIPE CLAMP. VARIES 4000 2m x 4m x 0.15m Thk. PLAIN CONCRETE SLAB
PROJECT NAME AND LOCATION: SHEET CONTENTS: PREPARED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO: SHEET NO:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS C. Y. 2022 PROJECT RHUELLE VALENTIN T. JANER
REGIONAL OFFICE II DETAILED ENGINEERING DESIGN PLAN FOR ARCHITECT II
NUEVA VIZCAYA CONSTRUCTION/ REHABILITATION OF WATER SUPPLY/ ISOMETRIC VIEW OF HOR. RAINWATER TANK A 3
SEPTAGE & SEWERAGE/ RAINWATER COLLECTOR SYSTEM DETAILED PLAN OF STAINLESS STEEL HOR. DESIGNED: REYNALDO V. RAGASA, JR. EDISON C. BASILIO PERFECTO E. URBAN, JR. MARLYN G. INGUILLO
2ND DISTRICT ENGINEERING OFFICE - RAINWATER COLLECTOR IN PUBLIC FACILITIES RAINWATER TANK ENGINEER II OIC, PLANNING AND DESIGN ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
DUPAX DEL NORTE, NUEVA VIZCAYA c. DUPAX DEL NORTE NHS POBLACION ANNEX, BRGY. MALASIN, JIOVANNI RUPAC - DANGAN SECTION 3 4 4
DUPAX DEL NORTE, NUEVA VIZCAYA ENGINEER II (CTO BBBP) DATE: DATE: DATE: DATE:
RAIN HEAD, SLOPED NOTES:
SCREEN DIVERTS DEBRIS.
1. TANK SHOULD BE FIRM, FLAT & ON STABLE PLATFORM IN ACCORDANCE
PVC PIPE, Ø100mm, S-1000.
SECOND FINER SCREEN WITH MANUFACTURER'S RECOMMENDATIONS. TANK BASE UNIT MUST BE
TANK ACCESS. SUFFICIENT TO SUPPORT WEIGHT OF TANK WHEN FULL.
PREVENTS INSECTS FROM
GETTING INTO TANK. AIR RELIEF VENT
w/ INSECT SCREEN. 2. 100% OF ROOF AREA SHALL DRAIN TO THE TANK.
FIRST FLUSH DIVERTER
(DOWNPIPE-TYPE) OVERFLOW PIPE w/ LOUVERED
3. IT IS RECOMMENDED TO CONNECT THE FOLLOWING HOUSEHOLD
OUTLET FOR INSECT
SLOW-DRIP FLOW FIXTURES TO THE RAINWATER TANK SUPPLY:
PREVENTION (100mm).
- ALL OUTDOOR TAPS
CONTROL VALVE
NON-POTABLE WATER TO - ALL TOILETS
HOSE BIBB. - WASHING MACHINE (COLD TAP)
PVC BLUE PIPE, Ø50mm - FOR MAIN LINE
4. ALL PLUMBING WORKS SHALL BE UNDERTAKEN BY A LICENSED PLUMBER
STAINLESS STEEL STORAGE PVC BLUE PIPE, Ø20mm - MAIN TO HOSE BIBB
WITH THE CONSENT OF THE MANUFACTURER & IN ACCORDANCE WITH ALL
TANK (HORIZONTAL) W/ PVC PIPE, Ø100mm, S-1000 STANDARDS, CODES & REGULATIONS.
STAINLESS STEEL(SS)
LADDER ( 1.70mØ - 3m 2m x 4m x 0.15m Thk. PLAIN CONCRETE SLAB 5. TANK & PUMP SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S
LONG ) ( Volume of Tank = REQUIREMENTS.
6,809 liters ) 1 DETAILED ISOMETRIC SECTION OF STAINLESS STEEL HOR. RAINWATER TANK
A 4 SCALE: Nts. 6. ANNUAL RAINFALL = 4464.90mm (ACCORDING TO THE HIGHEST
CLIMATOLOGICAL NORMAL RECORDED BY THE PHILIPPINE ATMOSPHERIC,
GEOPHYSICAL AND ASTRONOMICAL SERVICES ADMINISTRATION (PAGASA).
ALL TYPE OF ROOFING ACCEPTABLE.
PRE-PAINTED GUTTER (GA. 24) w/ SCREEN ON TOP.
PVC PIPE, Ø75mm, S-1000 (COLLECTOR PIPE FROM GUTTER)
RAIN HEAD, SLOPED
SCREEN DIVERTS DEBRIS.
PVC PIPE, Ø100mm, S-1000.
2'' GAP AT DOWNSPOUT.
TANK ACCESS.
SECOND FINER SCREEN AIR RELIEF VENT
PREVENTS INSECTS FROM w/ INSECT SCREEN.
GETTING INTO TANK.
STAINLESS STEEL STORAGE OVERFLOW PIPE w/ LOUVERED
TANK (HORIZONTAL) W/ OUTLET FOR INSECT PREVENTION (100mm).
STAINLESS STEEL(SS) LADDER NON-POTABLE WATER TO
FIRST FLUSH DIVERTER ( 1.70mØ - 3m LONG ) ( Volume of HOSE BIBB.
(DOWNPIPE-TYPE) Tank = 6,809 liters )
PVC BLUE PIPE, Ø50mm - FOR MAIN LINE
SLOW-DRIP FLOW PVC BLUE PIPE, Ø20mm - MAIN TO HOSE BIBB
100
150
ANGLE BARS
50
100mm Thk. GRAVEL FILL
100
(DIMENSIONS AND SIZES VARIES 4000 2m x 4m x 0.15m Thk. PLAIN CONCRETE SLAB
ARE BASED ON
MANUFACTURER'S
DETAILS) DETAILED ELEVATION OF STAINLESS STEEL HOR. RAINWATER TANK
2
A 4 SCALE: 1: 50 Mts.
PROJECT NAME AND LOCATION: SHEET CONTENTS: PREPARED: REVIEWED: SUBMITTED: RECOMMENDED: APPROVED: SET NO: SHEET NO:
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS C. Y. 2022 PROJECT RHUELLE VALENTIN T. JANER
REGIONAL OFFICE II DETAILED ENGINEERING DESIGN PLAN FOR DETAILED ISOMETRIC SECTION OF STAINLESS ARCHITECT II
NUEVA VIZCAYA CONSTRUCTION/ REHABILITATION OF WATER SUPPLY/ A 4
STEEL HOR. RAINWATER TANK REYNALDO V. RAGASA, JR. EDISON C. BASILIO PERFECTO E. URBAN, JR. MARLYN G. INGUILLO
SEPTAGE & SEWERAGE/ RAINWATER COLLECTOR SYSTEM DESIGNED:
2ND DISTRICT ENGINEERING OFFICE DETAILED ELEVATION OF STAINLESS STEEL ENGINEER II OIC, PLANNING AND DESIGN ASSISTANT DISTRICT ENGINEER DISTRICT ENGINEER
- RAINWATER COLLECTOR IN PUBLIC FACILITIES 4 4 4
DUPAX DEL NORTE, NUEVA VIZCAYA c. DUPAX DEL NORTE NHS POBLACION ANNEX, BRGY. MALASIN, HOR. RAINWATER TANK JIOVANNI RUPAC - DANGAN SECTION
DUPAX DEL NORTE, NUEVA VIZCAYA ENGINEER II (CTO BBBP) DATE: DATE: DATE: DATE: