National Building Code - P.D.

1096
2 - Minimum number of exit for floors above the first storey having an occupant load of
more than 10
3 - Number of exit for occupant load of 599-999.

Stairs. Stairs shall be at least 750 millimeters in clear width, with a rise of 200 millimeters and
a minimum run of 200 millimeters

1.20 sqm. - Standard minimum area of a toilet.


1.50 mts. - Minimum dimension of a kitchen.
14.00 cum. - Air space requirement for a habitable room per person.
300 mm - Maximum projection beyond the property line of a footing along the national
road and at least 2.40 mts. In depth.
3.00 mts. - Minimum clearance of a canopy or a marquee from the sidewalk.
1.80 mts. - Minimum headroom clearance for a mezzanine.
10% of flr. Area - Minimum total area of a window or an opening for a room without
artificial ventilation.
0.90 mtr. - Maximum height of a handrail above the stair thread.
2.70 mts. - Minimum ceiling height for naturally ventilated rooms.
0.80 mtr. - Minimum height of a handrail above the stair thread.
1.20 mts. - Maximum dimension of a stair landing.
2.00 mts. - Minimum headroom clearance for any stair.
200 mm - Minimum run of a stair for Group A dwellings (residential)
2.10 mts. - Minimum ceiling height from 3rd floor to succeeding floors with artificial
ventilation.
6.00 sqm. - Minimum area of rooms for human habitation.
2.00 mts. - Least dimension of rooms for human habitation.
750 mm - Minimum width of stairs serving less than 10 occupants.
100 mm - Maximum reduction in width of a stair due to trims and handrails.
150 mm - Minimum run of a winding stair.
300 mm - Maximum run of a winding stair.
3.00 mts. - Width of stair requiring an intermediate handrail.
28.00 sqm. - Unit area per occupant for dwellings.