Reference: 300-I-9010445-EN-09
Issue: 07.2016 1/30
Safety valve DSV-A3
Published by
Bucher Hydraulics AG
Industriestrasse 15
CH-6345 Neuheim
Phone +41 41 757 03 33
Fax +41 41 757 05 00
Email info.ch@bucherhydraulics.com
Internet www.bucherhydraulics.com
Classification: 430.325.346
2/30 300-I-9010445-EN-09/07.2016
Safety valve DSV-A3
Contents Page
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3 Installation and commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.1 Mechanical installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.2 Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.3 Connecting the pressure switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.4 Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.1 Normal operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.2 Manual operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.1 Maintenance intervals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.2 Maintenance tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.3 Leakage test of the valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.4 Cleaning the pilot filter and the nozzle (DSV175‐A3 and DSV350-A3 only) . . . . . . . . . . . 22
5.5 Simplified functional test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6 Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.1 Replacement of the solenoid coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.1.1 Version WITHOUT emergency power winding (plastic coil housing) . . . . . . . . . . . 24
6.1.2 Version WITH emergency power winding (metal coil housing) . . . . . . . . . . . . . . . . 26
7 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
8 Service parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
300-I-9010445-EN-09/07.2016 3/30
1 General, product description Safety valve DSV-A3
4/30 300-I-9010445-EN-09/07.2016
Safety valve DSV-A3 1 General, product description
1.3.2 Conformity
EC-Directive 2006/42/EG
EC-Directive 2014/33/EU
The product was designed and developed in conformity with the follow
ing directives and standards:
2. Machinery Directive,
Type-eximination certificate
DSV-A3/175/230/24/KH
2014/33/EU:EU-UCM 002
1607-
05934
3. Nameplate
4. Position of serial no.
(format: YYMM-xxxxx)
300-I-9010445-EN-09/07.2016 5/30
1 General, product description Safety valve DSV-A3
Valve type
Safety valve DSV-A3
Nominal size
15…250l/min = 175
150…500l/min = 350
250…1000l/min = 700
Nominal voltage, main coil winding
230VAC / 50 Hz = 230
Nominal voltage, emergency power winding
without = 00
12VDC = 12
24VDC = 24
Cylinder port
with ball valve = KH
with flange = FL
3 Z
Z P P
2 1 4 2 1 4
Legend 1 Solenoid
2 Manual release
3 Ball valve
4 Pilot filter
P Lift valve port
MZ Pressure switch port
* 2nd port in housing DSV700-A3 only
Z Cylinder port
6/30 300-I-9010445-EN-09/07.2016
Safety valve DSV-A3 1 General, product description
10 5
4
6
MZ 7
8 1
P
9
Legend 1 Solenoid
2 Manual release
3 Ball valve
4 Pilot filter
5 Main filter
6 Nozzle
7 Main spool
8 Pilot valve
9 Lift valve
10 Cylinder
P Lift valve port
MZ Pressure switch port
Z Cylinder port
300-I-9010445-EN-09/07.2016 7/30
1 General, product description Safety valve DSV-A3
Weight
Type Port P Port Z Port MZ
[kg]
…/FL G1 female thread 2.5
DSV-A3/175/… G1 female thread
…/KH 28-L male thread 4
G¼ female thread
…/FL G1½ female thread 6
DSV-A3/350/… G1½ female thread
…/KH 42-L male thread 10
cover:
…/FL 19
G¼ female thread
DSV-A3/700/… G2½ female thread G2 female thread
housing:
…/KH 23
G⅜ female thread
8/30 300-I-9010445-EN-09/07.2016
Safety valve DSV-A3 1 General, product description
1.5.3.2 Dimensions
DSV−A3/175/.../KH DSV−A3/175/.../FL
DSV−A3/350/.../KH DSV−A3/350/.../FL
DSV−A3/700/.../KH DSV−A3/700/.../FL
300-I-9010445-EN-09/07.2016 9/30
1 General, product description Safety valve DSV-A3
10/30 300-I-9010445-EN-09/07.2016
Safety valve DSV-A3 1 General, product description
ATTENTION!
Simultaneous energising of the main coil winding and emergency
power winding will overheat the solenoid.
Risk of damage to the solenoid!
Never energise the main coil winding and the emergency power
winding simultaneously.
ATTENTION!
The plug of the solenoid is potted into the coil socket together with
a rectifier.
The attempt to remove the plug will destroy the solenoid.
By no means detach the plug from the solenoid.
ATTENTION!
The solenoid coil shall be energized while beeing mounted on the
solenoid tube. Energizing whithout the solenoid tube may cause
overheating of the solenoid coil.
CAUTION!
300-I-9010445-EN-09/07.2016 11/30
1 General, product description Safety valve DSV-A3
1.5.5 Notes on the integration of the safety valve DSV-A3 into the lift control
de-energised
energised
arbitrary
must
must
be
be
No influence of the safety valve DSV-A3
Travel UP (incl. relevelling) X
during travel UP
The safety valve DSV-A3 must be ener
gised at least 300 ms before travel starts,
Travel DOWN (incl. relevelling) X
else the travel control of the lift valve can
be effected adversely
The safety valve DSV-A3 must be de-ener
gised for reasons of energy saving, solen
oid life-time and oil degradation. Load pres
Standstill X
sure measurement should be provided by
means of pressure switch located at port
MZ of the safety valve DSV-A3..
No influence of the safety valve DSV-A3
during unintended travel UP with door
Unintended travel UP with door open X
open; lift must be stopped by disconnection
of the motor contactors.
Interruption of the current to the solenoid of
the safety valve DSV-A3 is required when
Unintended travel DOWN with door
X the unlocking zone is left (emergency
open
stop); notes on the positioning of the shaft
switches ==> page 15, chapter 1.5.5.3
No influence of the safety valve DSV-A3
Hand pump operation X
during travel UP with hand pump operation
12/30 300-I-9010445-EN-09/07.2016
Safety valve DSV-A3 1 General, product description
1 2 3 4 5 6 7 8 9
Y–
V = 100 % V = 100 %
* Motor run-on time of 0.5…1s ∗∗∗ 300ms before steps 7 and 8
** Drop-out delay of 0.5…1s, after drop ∗∗∗∗ Deenergising only when lift is at
out of slow command standstill
Y-Δ Y starting time of up to approx.
3s with Y-Δ
300-I-9010445-EN-09/07.2016 13/30
1 General, product description Safety valve DSV-A3
14/30 300-I-9010445-EN-09/07.2016
Safety valve DSV-A3 1 General, product description
1.5.5.4 Function of the safety valve DSV-A3 is case of an unintended travel DOWN
300-I-9010445-EN-09/07.2016 15/30
2 Safety instructions Safety valve DSV-A3
2 Safety instructions
This documentation (manual) advises the user of the dangers and re
maining risks that can arise even when the product is being used pro
perly and for its intended purpose. It is essential to take note of the sa
fety instructions in each section.
16/30 300-I-9010445-EN-09/07.2016
Safety valve DSV-A3 3 Installation and commissioning
Connection type
Tightening torque
DSV175-A3 DSV350-A3
G2½
Screw joint at port P
G1 G1½ 400Nm
100Nm 220Nm G2
Screw joint at port Z
(Version FL with flange) 320Nm
G¼ G¼ 20Nm
Plug screw at port MZ
20Nm G⅜ 30Nm
300-I-9010445-EN-09/07.2016 17/30
3 Installation and commissioning Safety valve DSV-A3
1. Connect the solenoid of the safety valve DSV-A3 to the lift control,
⇒page10, chapter1.5.4
300-7-10023535
18/30 300-I-9010445-EN-09/07.2016
Safety valve DSV-A3 3 Installation and commissioning
3.4 Startup
Note: After the initial installation air can be trapped inside the safety valve DSV-
A3, particularly when the safety valve DSV-A3 is mounted with the cover (1)
pointing upward.
Air trapped inside the safety valve DSV-A3 can potentially cause oscillations
when the lift starts.
If oscillations occur during lift start:
1. Execute approx. 5 to max. 10 travels, until there are no oscillations
during lift start any more
I If oscillations continue to occur after 10 travels, they will not be caused
by air inside the safety valve. The cause must be searched for some
where else.
2 Alternatively:
1 1. On the lid (1) slacken either the plug screw (2) or the pressure
switch, vent the air, then tighten the plug screw (2) or the pressure
switch to 20Nm again
300-I-9010445-EN-09/07.2016 19/30
4 Operation Safety valve DSV-A3
4 Operation
CAUTION!
2. Pull the red plastic handle (B) on the solenoid of the safety valve
DSV-A3 to the stop and keep it in the extended position
3. Control the travel by operation of the manual lowering (C) on the lift
valve until the landing intended for the evacuation of the car is
reached
A
B When the lift has stopped:
4. Release the red plastic handle (B)
C
20/30 300-I-9010445-EN-09/07.2016
Safety valve DSV-A3 5 Maintenance
5 Maintenance
2. Make sure that the lift is stopped at a place at which the position of
the car can be determined with sufficient accuracy
ATTENTION!
The plug of the solenoid is potted into the coil socket together with
a rectifier.
The attempt to remove the plug will destroy the solenoid.
By no means detach the plug from the solenoid.
3. Make sure that both the main coil winding and the emergency
power winding (optional) of the solenoid of the safety valve DSV-A3
are NOT energised
4. Actuate the manual emergency lowering (C) on the lift valve and
D keep it in open position
5. Check that
I the indication on the pressure gauge (D) of the lift valve drops to zero
and
I after that the car does not move in a gaugeable manner any more
300-I-9010445-EN-09/07.2016 21/30
5 Maintenance Safety valve DSV-A3
5.4 Cleaning the pilot filter and the nozzle (DSV175‐A3 and DSV350-A3
only)
4
3 2
1
B E
A
1. Make sure that the ball valve between the safety valve DSV-A3 and
the cylinder is closed
CAUTION!
2. Pull the red plastic handle (B) on the solenoid of the safety valve
DSV-A3 to the stop and keep it in the extended position
3. Operate the manual emergency lowering on the lift valve until the
indication on the pressure gauge of the lift valve has dropped to
zero
5. Unscrew the filter screw (1) from the safety valve DSV-A3
22/30 300-I-9010445-EN-09/07.2016
Safety valve DSV-A3 5 Maintenance
6. Remove the pilot filter (3) from the filter screw (1)
9. Make sure that the o-ring (4) is properly seated inside the housing
of the safety valve DSV-A3
10. Make sure that the o-ring (2) is properly seated on the filter
screw(1)
11. Insert the pilot filter (3) into the filter screw (1)
12. Screw the filter screw (1) together with the pilot filter (3) into the
safety valve DSV-A3 and tighten to 25Nm
13. Open the ball valve between the safety valve DSV-A3 and the cylin
der
ATTENTION!
The plug of the solenoid is potted into the coil socket together with
a rectifier.
The attempt to remove the plug will destroy the solenoid.
By no means detach the plug from the solenoid.
ATTENTION!
The plug of the solenoid is potted into the coil socket together with
a rectifier.
The attempt to remove the plug will destroy the solenoid.
By no means detach the plug from the solenoid.
2. Make sure that the main coil winding and the emergency power
winding (optional) of the solenoid of the safety valve DSV-A3 are
properly connected to the lift control again
300-I-9010445-EN-09/07.2016 23/30
6 Repair Safety valve DSV-A3
6 Repair
Except for the filter screw, the pilot filter and the pertinent o-rings as well
as the solenoid coil the safety valve DSV-A3 has no user detachable or
lift service detachable parts.
Any dismantling or repair of the safety valve DSV-A3 beyond the clean
ing of the pilot filter and the nozzle (⇒page22, chapter5.4) and the re
placement of the solenoid coil must be executed by the Bucher Hydrau
lics customer service only.
6
4
3
2
1 5
CAUTION!
24/30 300-I-9010445-EN-09/07.2016
Safety valve DSV-A3 6 Repair
ATTENTION!
The plug of the solenoid is potted into the coil socket together with
a rectifier.
The attempt to remove the plug will destroy the solenoid.
By no means detach the plug from the solenoid.
1. Make sure that the main coil winding is disconnected from the lift
control
4. Pull the solenoid coil (4) off the solenoid tube (5) together with the
frontside o-ring (3)
5. Make sure that the backside o-ring (6) is placed at the rear end of
the solenoid tube (5)
6. Slide the new solenoid coil (4) onto the solenoid tube (5)
7. Put the frontside o-ring (3) into the recess of the solenoid coil (4)
8. Screw the nut (2) onto the solenoid tube (5) and hand-tighten it
(min.7Nm)
9. Check the firm fit of the solenoid coil (4) on the solenoid tube (5):
the solenoid coil shall by no means wobble and shall not rotate with
moderate force applied
ATTENTION!
Incorrect wiring will damage the solenoid.
Connect voltages only according to the type of the solenoid coil
and the prescribed wire assignment.
11. Connect the solenoid coil (4) to the lift control, ⇒page10,
chapter1.5.4
300-I-9010445-EN-09/07.2016 25/30
6 Repair Safety valve DSV-A3
4
3
2
1
5
CAUTION!
ATTENTION!
The plug of the solenoid is potted into the coil socket together with
a rectifier.
The attempt to remove the plug will destroy the solenoid.
By no means detach the plug from the solenoid.
1. Make sure that the main coil winding and the emergency power
winding are disconnected from the lift control
4. Pull the solenoid coil (4) off the solenoid tube (5) together with the
spring washer (3)
5. Slide the new solenoid coil (4) onto the solenoid tube (5)
26/30 300-I-9010445-EN-09/07.2016
Safety valve DSV-A3 7 Disposal
7. Screw the hex nut (2) onto the solenoid tube (5) and hand-tighten it
(min.7Nm)
8. Check the firm fit of the solenoid coil (4) on the solenoid tube (5):
the solenoid coil shall by no means wobble and shall not rotate with
moderate force applied
ATTENTION!
Incorrect wiring will damage the solenoid.
Connect voltages only according to the type of the solenoid coil
and the prescribed wire assignment.
10. Connect the solenoid coil (4) to the lift control, ⇒page10,
chapter1.5.4
7 Disposal
The safety valve DSV-A3 contains pretensioned springs. The energy
stored in the springs, however, is too low to create a risk during dismant
ling of the safety valve DSV-A3.
According to the knowledge by the time of the creation of this installation
and startup guide a safety valve DSV-A3 that has been cleansed from
hydraulic fluid contains no substances that are subject to special dis
posal procedures.
Dispose of the solenoid coil incl. cable as waste of electrical equipment,
dispose of the rest of the safety valve DSV-A3 as metal waste.
300-I-9010445-EN-09/07.2016 27/30
8 Service parts list Safety valve DSV-A3
2
1.3.2
2.1
1.3.1
2.2
1.3
1.2
1.1
4 1
5
3
3.1
3.2
28/30 300-I-9010445-EN-09/07.2016
Safety valve DSV-A3 8 Service parts list
DSV350-A3
6
2
2.1
2.2
1.3.2
1.3.1
4 1.3
5
1.2
1.1
1
3
3.1
3.2
300-I-9010445-EN-09/07.2016 29/30
8 Service parts list Safety valve DSV-A3
DSV700-A3 5
7 8
1
1.1
1.2
3 2
4 2.1
Available as a standard service part
2.2
30/30 300-I-9010445-EN-09/07.2016