Data Sheet

Issue: 07.09

Pressure Switch, type DP

0 0

1 Description
S can be used with all types of lift valves
S the switch is screwed directly into the
appropriate port and constantly senses the
cylinder pressure
S is connected as normally open
S can also be connected as a change−over
switch
S used for monitoring of minimum static
pressure
S can also be used as a slack−rope switch

1.1 Safety switch to monitor of minimum static pressure


Opens the electrical control circuit when the pressure drops below a
minimum permissible level if, for example, the hose rupture valve closes.
No further travel is possible in either direction.
While the car is travelling, this pressure−switch function should be
bridged to prevent unwanted circuit interruptions that could result from
dynamic pressure fluctuations.

Issue: 09.2015 1/4 Reference: 300−I−9010115−EN−04


Reference: 300−A−9010115−E−04/07.09
Classification: 450.795. 1/4
DP

2 Installation and commissioning


2.1 Fitting the pressure switch

Caution
Oil under high pressure
Can cause serious injuries
Before fitting the pressure switch, make sure that all pressure in the lift
control valve has been vented.

1. Screw the pressure switch into the lift control valve


I with the G¼" male thread

2. Connect the cable

2.2 Setting procedures

1. Close ball valve at lift control valve


2. Relieve pressure in valve
3. Develop the required switching pressure in the valve
I with hand pump

4. Remove connector socket from pressure switch


5. Connect an ohmmeter (with beep tone) to the terminals on the
pressure switch
6. Turn adjusting screw on the pressure switch until the switching
point is reached
7. Re−attach connector socket and tighten screw
8. Open ball valve

Issue: 09.2015 2/4 Reference: 300−I−9010115−EN−04


300−A−9010115−E−04/07.09 2/4
DP

3 Technical data

General characteristics Description, value, unit


Adjustment range 1 ... 10 bar
Pressure safety limit 300 bar
Factory setting 5 bar
Hysteresis 5%
Enclosure protection IP 65
Switch rating, alternating S 2 A with resistive loads (AC 12)
current S 1 A max. 72 VA with inductive loads (AC 13)
Minimum contact loading 100 mA, 10 VAC/DC

Switch rating, direct current

Voltage Resistive loads (DC 12) Inductive loads (DC 13)


250 V DC 0.15 A 0.1 A
125 V DC 0.2 A 0.1 A
75 V DC 0.5 A 0.25 A
50 V DC 1.0 A 0.5 A
24 V DC 2.0 A 1.0 A

4 Dimensions
~50 before tightening
~50

Pg 9

A/F 27
9

Issue: 09.2015 3/4 Reference: 300−I−9010115−EN−04


300−A−9010115−E−04/07.09 3/4
DP

5 Connecting Cable
The connecting cable is used to connect the pressure switch to the
elevator control system.

5.1 Dimensions
A B A

40 mm L 40 mm

A Wire end ferrule L Part No.


B LiYY 2x0.75mm2 flexible cable, grey ou-
6m 7013432
ter sheath, white and brown leads
12m 7013433
20m 7015985
Other lengths on request

5.2 Diagram
4 Connected as normally open:
terminals À .. Ã

2 4 D white
P
E brown
1

info.nh@bucherhydraulics.com www.bucherhydraulics.com
E 2009 by Bucher Hydraulics AG, CH−6345 Neuheim.
All rights reserved.
Data is provided for the purpose of product description only, and must not be considered as warranted characteristics in the legal sense.
The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to
continual improvement, we reserve the right to amend the product specifications contained in this catalogue.

Issue: 09.2015 4/4 Reference: 300−I−9010115−EN−04


300−A−9010115−E−04/07.09 4/4