You are on page 1of 1

FAULT INDICATION CAUSE EFFECT REMEDY

Car Call Accept To many Re-levels within Lift will continue Test/Reset to reset.
Level 1 flashing One hour (C0/C1) working.

Car Call Accept Door switch check failure (T40) Lift will stop working. Test/Reset to reset.
Level 2 flashing Controller gave door-open-signal, but door did
not open or closed limits/locks did not change
State.

Car Call Accept Door re-open count (C2,T7/T27) Doors will stay in Automatic reset
Level 1 & Doors repeatedly re-open, because of Open position. After time-delay or
-Obstruction
Level 2 flashing -Limit-switch/lock problem With car-call, also
Test/Reset to reset.
Car Call Accept Max. travel timer-trip (T17) Lift will stop Test/Reset to
Level 1 & Lift did not finish journey within set time in working reset.
Either up or down direction
Level 2 flashing -Pump/valve problem
alternately

Car Call Accept Re-level switch fault Lift will finish Test/Reset to
Re-level switch made outside of door-zone
Level 3 flashing -Re-level magnet on tape-head too long Journey and stop reset.
-Door-zone magnet too short Working.
-Switch faulty

Common Timers/Counters:

DEVICE FUNCTION FACTORY SETTING


T0/T20 or Door 1/2 dwell time K100 = 10seconds
D8030 Adjustable on PLC.
T7/T27 Door 1/2 re-open time K300 = 30seconds
T11 Pump off delay (soft stop) K5 = 0.5seconds
T12 Quick close from car K50 = 5seconds
T16 Max. re-level time K80 = 8seconds
T17 Max. travel time K400 = 40seconds
T18 Automatic reset after door re-open count K1200 = 120seconds
T29/T30 Door close delay (Message/Buzzer time) K30 = 3seconds
T40 Door switch check time K40 = 4seconds
C0/C1 Re-level count K30
C2 Door re-open count K10

NOTE: If in doubt, phone Cord Controls!

Directors: K.Davies, J.M.Davies