You are on page 1of 1

AD2-C1-00-YM_-PRP-IDM-00520 POWER BLOCK START-UP AND SHUTDOWN SEQUENCES

Annex 2: standstill 150h start-up curves


Start-up curves of GTs
Lead GT/HRSG purge end Lead GT at minimum load Lag GT started Lag GT/HRSG purge end Lead GT ramping up to 30% load Lag GT at minimum load Lag GT ramping up to 30% load Lag GT at 30% load Lead/lag GTs ramping up to 100% load Lead/lag GTs at 100% load

Lead diverter damper opened Lead HRSG HP bypass in operation Lead HRSG floor pressure in HP Lead HRSG floor pressure in HRH Lag HRSG HP bypass in operation Lag HRSG HRH bypass in operation Lag HRSG floor pressure in HP Lag HRSG connected to header Lag HRSG bypasses closed

Auxiliary steam available ST sealed Lead GT at 30% load Lag HRSG floor pressure in HRH ST admission fully open (sliding mode) ST fully loaded
650 130
Vacuum in condenser ST rolling start Lead HRSG bypasses closed ST loaded with lag HRSG

600 Lag diverter damper opened ST loaded with lead HRSG 120

Lead HRSG HRH bypass in operation


550 110

500 100

450 90
Exhaust temperature [ºC]

400 80

Load [%]; Speed [%]


350 70

300 60

250 50

200 40

150 30

100 20

50 10

0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300
Time [min]

GT11 exhaust temperature [ºC] GT12 exhaust temperature [ºC] GT11 speed [%] GT12 speed [%] GT11 load [%] GT12 load [%] Main events for GTs Main events for HRSGs Main events for ST

Start-up curves of HRSGs


Lead GT/HRSG purge end Lead GT at minimum load Lag GT started Lag GT/HRSG purge end Lead GT ramping up to 30% load Lag GT at minimum load Lag GT ramping up to 30% load Lag GT at 30% load Lead/lag GTs ramping up to 100% load Lead/lag GTs at 100% load

Lead diverter damper opened Lead HRSG HP bypass in operation Lead HRSG floor pressure in HP Lead HRSG floor pressure in HRH Lag HRSG HP bypass in operation Lag HRSG HRH bypass in operation Lag HRSG floor pressure in HP Lag HRSG connected to header Lag HRSG bypasses closed
Auxiliary steam available ST sealed Lead HRSG HRH bypass in operation ST loaded with lead HRSG Lag HRSG floor pressure in HRH ST admission fully open (sliding mode) ST fully loaded
180 720
Vacuum in condenser ST rolling start Lead GT at 30% load Lead HRSG bypasses closed ST loaded with lag HRSG
170 680
Lag diverter damper opened
160 640

150 600

140 560

130 520
Pressure [bara]/Steam mass flow [%]

120 480

110 440

Temperature [ºC]
100 400

90 360

80 320

70 280

60 240

50 200

40 160

30 120

20 80

10 40

0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300
Time [min]

HRSG 11 HP pressure [bara] HRSG 12 HP pressure [bara] HRSG 11 HP steam mass flow [%] HRSG 12 HP steam mass flow [%] HRSG 11 HRH pressure [bara] HRSG 12 HRH pressure [bara] HRSG 11 HRH steam mass flow [%] HRSG 12 HRH steam mass flow [%]
HRSG 11 HP steam temperature [ºC] HRSG 12 HP steam temperature [ºC] HRSG 11 HRH steam temperature [ºC] HRSG 12 HRH steam temperature [ºC] Main events for GTs Main events for HRSGs Main events for ST

Start-up curves of ST
Lead GT/HRSG purge end Lead GT at minimum load Lag GT started Lag GT/HRSG purge end Lag GT at minimum load Lead GT ramping up to 30% load Lag GT ramping up to 30% load Lag GT at 30% load Lead/lag GTs at 100% load

Lead diverter damper opened Lead HRSG HP bypass in operation Lead HRSG floor pressure in HP Lead HRSG floor pressure in HRH Lead HRSG HRH bypass in operation Lead GT at 30% load Lag HRSG HP bypass in operation Lag HRSG HRH bypass in operation Lag HRSG floor pressure in HP Lag HRSG floor pressure in HRH Lag HRSG bypasses closed

Auxiliary steam available ST sealed ST rolling start Lag HRSG connected to header ST admission fully open (sliding mode) ST fully loaded
180 720
Lag diverter damper opened Lead HRSG bypasses closed ST loaded with lag HRSG Lead/lag GTs ramping up to 100% load
170 680
Vacuum in condenser ST loaded with lead HRSG
Pressure [bara]/Condenser pressure x 100 [bara]/Speed [%]/Load [%]

160 640

150 600

140 560

130 520

120 480

110 440

Temperature [ºC]
100 400

90 360

80 320

70 280

60 240

50 200

40 160

30 120

20 80

10 40

0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300
Time [min]

ST HP pressure [bara] ST speed [%] ST load [%] ST HRH pressure [bara] Auxiliary steam pressure [bara] Condenser pressure [kPa] ST HP Temperature [ºC] ST HRH Temperature [ºC] Main events for GTs Main events for HRSGs Main events for ST