You are on page 1of 2

DISTRIBUTION SOLUTIONS

Retrofitting
Solutions for Voltas make SF6 gas circuit breaker type FG2

Circuit breaker retrofitting is a


cost-effective alternative to
complete switchgear replacement.
By retrofitting a circuit breaker in
switchgear the required
specifications are met with the
latest technology at only partial
cost of replacing the equipment.
This becomes more evident when
the associated costs of civil works,
cabling and downtime are
considered.


01

— Typically, retrofitting constitutes replacement of Safety


01
ABB VD4 vacuum vital equipment having similar or advanced features, • Strong fault risk reduction
retrofit for Voltas
make FG2 circuit breaker
for life extension, reduced maintenance and • Additional embedded safety features
improved functionality. This includes upgradation • Improved operator protection
and modernization of basic equipment and allied
parts. The retrofitted switchgear offers far greater Technology
system reliability, long term availability of spares • Latest generation apparatus
and increased safety to the operators with minimal • Designed according to IEC 62271-100 standard
investment and downtime.
Project
ABB is a full system provider for retrofit solutions, • Short implementation time for replacement
from the proposal and design, through the • Minimum shutdown of the switchboard
manufacturing and testing, up to the installation • Smooth site activity
and commissioning.
Investment
Benefits • Limited capital investment
Reliability • Minimization of further maintenance costs
• Significant life time extension • Warranty on the conversion work
• Lower maintenance requirements
• Long time availability of spare parts
— Facts
02
Voltas make SF6 gas circuit FG2 is a family name of wide range of SF6 gas circuit
breaker type FG2 breakers manufactured by Voltas Switchgears
— Ltd. These circuit breakers are widely present in
03 the networks and ABB can provide the relevant
ABB VD4 vacuum
retrofit for Voltas retrofitting solutions. This equipment has been
make FG2 circuit breaker in service for decades and retrofitting could
significantly extend the operational life of the
switchgear. The use of well proven VD4 vacuum
circuit breaker enhances the reliability of the
switchgear.

Technical data
A full range of retrofit solutions have been
developed based on latest ABB vacuum circuit
breakers. ABB proposal provides the best fit for
purpose apparatus for each switchgear unit,
depending on the complete network equipment
conditions and the specific feeder operational —
characteristics. 02

The following basic details are necessary for


providing standard retrofit solutions:

• All rating plate details


• Four sided pictures of circuit breaker
• Compartment inner picture
• Existing panel schematic diagram
• Dimension details of circuit breaker

Rating
Solution VD4-FG2
Rated voltage [kV] 12
Rated current (40 0C) [A] 630, 12501)
Rated power frequency [kV 1 min] 28
withstand voltage
Rated lightning impulse [kVp] 75
withstand voltage
Rated short circuit [kA] 40
current
Short circuit current [s] 3
duration

Peak current [kAp] 100 03
1)
Higher ratings can be developed on request Doc Id: 1VYN401890-120 - Copyright© 2021 ABB. All rights reserved. ABB

— —
For more information please contact: We reserve the right to make technical We reserve all rights in this document and
changes or modify the contents of this in the subject matter and illustrations
document without prior notice. With contained therein. Any reproduction,
ABB India Limited
regard to purchase orders, the agreed disclosure to third parties or utilization of
Plot No 79, Street No.17,
particulars shall prevail. ABB does not its contents – in whole or in parts –
MIDC Estate, Satpur,
accept any responsibility whatsoever for is forbidden without prior written
Nashik – 422 007
potential errors or possible lack of consent of ABB. Copyright© 2021
Maharashtra India
information in this document. ABB All rights reserved.
Phone: +91-253- 2201200