You are on page 1of 1
1604.3 Serviceability. Structural systems and members thereof shall be designed to have adequate stiffness to limit deflections and lateral drift. See Section 12.12.1 of ASCE 7 for dri limits epplicable to earthquake loading, ‘TABLE 1604.3 DEFLECTION LIMITS® >:° hs! CONSTRUCTION T [sorwifor iad] [Roof members Isupporing nanpastercelingf240| «240 | 180 et surporting cot Jerao]_aieo | 120 [oor members frsso]_— | 1240 IExenor wale inplester or stucco fries | — | eae | — ih face Srishes =| | = resto partons? ith plaster or stucco fishes 260) — | — th ther brite fnshee 240 [Wn fee Seisnes lrrzol — | — Farm bulking = [= [ie 1. For sructralrafing and sting made of formed metal sheets, the ota bad dafacton shall not exceed U0. Fr secandary roof structiral members Sipporing formed matalroofing, the iva oad defiacton sal ot exceed 160, For secondary wall members supporting formed metal sing, fn design wind load detection shal not axcecd 190, For rots, this excepton only apples when fe metal steetshave a roof cowering, », Flexdle flsing and portals paritone ate not gored by the provisions of his secon. The deflection citeron for intariarpartons based onthe horizon ina denen Sacton 1807 18 °c. See Section 2403 for pass support, {The defiecon int forte OL load combination cnly applies to th detection dus ote ereep component of ange ceed laud defection pis the Stotiom live load deflection. For wood structural members tha are ery atime f instalation and used under dry conditons in accordance withthe [ANSUAMC NOS, he cleep canporent of te ngrte delectun shall be permed tobe estmald asthe iva dead bad defection resulting om 050. For wend stucturel manbersatallother moisture canditions, the creep component ofthe long-term deflecion is permited tobe ertmated asthe ¢.The above deflections do nat ensure ajains! ponding. Roos that db nothavesufcient bps cr camber to ensure adequate drainage shallbo Irvestgatea or panaing See Sectan 161 forrain ana pending requrements ard Section 1903.4 or fot cranage requrements lading loads forthe purpose of dbterriring deflation. @-For ste! sructural members, the deadload shall be akon as 2070 ot supporting edge of gass or aluninum sandwich panes, the iota ead ceflecton skal cl exceed 180. Fer contnuous aluminum srucural members unporing edge of glass. the oa nad daflacton shall not excesd 175 fr nach las ite r fOr tha ante tnath of he meme whichever i roe stinger. For aluminum sandwich ganels used in rots or walls of roam adstons er pati covers, he ttl lad deflection shal not exceed 1/120 1804.3.1 Deflections. The deflections of structural members shall not exceed the more restrictive of the limitations of Sections 1604.3.2 through 1604.3.5 or that permitted by Table 1604.3. 1604.3.2 Reinforced concrete. The deflection of reinforced concrete structural members shall not exceed that permitted by ACI 318 1604.3.3 Steel. The deflection of steel structural members shall not exceed that permitted by AISC 360, AISI $100, ASCE 8, Sul J, SJI-JG, SJI K or SJ! LH/DLH, as applicable. 1604.3.4 Masonry. The deflection of masonry structural members shall not exceed thet permitied by TMS 402/ACI S3O/ASCE 5. 1604.3.5 Aluminum. ‘The deflection of aluminum structural members shall not exceed that permitted by AA ADM1 1604.3.6 Limits. The deflection limits of Section 1604.3.1 shall be used unless more restrictive deflection limits are required by @ referenced standard for the element or finish material.

You might also like