Checking of suitability of Normal mast (single cantilever assembly) outside curve including tangent tarck for

conventional OHE
Design data Symbol Remark Example value
span of OHE (m) s V 72.0 72.0
Radius of curvature of track (m) r V 72000 72000
versine of track v V 0.009 0.009
Tension in catenary wire (kgf) t1 V 1000 1000
Tension in contact wire (kgf) t2 V 1000 1000
Diameter-Catenary wire (m) d1 V 0.0105 0.0105
Diameter-Contact wire (m) d2 V 0.0122 0.0122
Diameter of Earth wire (m) 0.01227 0.01227
Radial tension factor for contact wire (1
rtf V 1 1
for tangent & 0 for curved track)
Radial tension in Contact wire rt V 11.11 11.11
Wind Pressure (kg/sq.m), IS:875 (Part-III) 2015, Navy blue-
wp V 73 73
73, Yellow-105, Blue-136, Green-155, Red-178
Unit weight of OHE (kg/m) wt C 1.60 1.60
Weight of man (kg) wtm C 60 60
Weight of cantiliver assembly (kg) wtb C 60 60
Diameter of Aluminium return conductor (m),
dr V 0.000 0.000
(if not in service =0)
Unit Weight of Aluminium return conductor (kg/m)
wtr V 0.000 0.000
(if not in service =0)
projected area factor for conductors a C 0.75 0.75
Wind load factor for droperss wlf C 1.05 1.05
Mast width along the track (m), BFB/RSJ-152, K/B125-125,
K/B150-150, K/B175-175, K/B200-200, K/B225-225, K/B250-250 wm V 0.152 0.152
(mm)
Height of mast above foundation level(m) hm C 8.15 8.15
Weight of return conductor fittings (kg)
wrf V 0.00 0.00
(if not in service =0)
Wind load factor on mast fm C 1.90 1.90
Weight of mast (kg/m) BFB-37.1, RSJ-52.1, K/B125-29.801,
K/B150-37.392, K/B175-42.91, K/B200-48.904, K/B225-56.21, wtm V 37.10 37.10
K/B250-65.21
Full length of mast (m) flm C 9.50 9.50
Radial pull Factor for tangent track-0, For curve track-1 V C 0.00 0.00
Radial pull in catenary Wire (kg)
rp1=(s*t1/r) V 0 0
Radial pull in contact Wire (kg) rp2=(s*t2/r) V 0 0
Unit wind load on catenary wire-kg/m wlf1=d1*wp*a*wlf V 0.60 0.60
Wind load on catenary wire wl1=wlf1*s V 43.46 43.46
Unit wind load on contact wire-kg/m wlf2=d2*wp*a*wlf V 0.70 0.70
Wind load on contact wire wl2=wlf2*s V 50.66 50.66
Unite wind load on Earth wire V 0.67 0.67
Wind load on Earth wire 48.37 48.37
Wind load on Return conductor wlc=dr*wp*wlf*a*s V 0.00 0.00
Wind load on mast wlm=wm*wp*hm*fm V 171.82 171.82
Design vertical load of OHE (kg) wto=wt*s+wtm+wtb/2 V 205.20 205.20
Weight of Return conductor & fittings wtrf=wtr*s+wrf V 0.00 0.00
Total Vertical load wto V 205.20 205.20
Bending moment Calculation
Length of lever arm for catenary wire (m) l1 C 7.81 7.81
Length of lever arm for contact wire (m) l2 C 6.41 6.41
Length of lever arm for Earth wire l3 7.30 7.30
Length of lever arm for Return conductor (m) (if not
lr C 0.00 0.00
in service =0)
Length of lever arm for Reurn conductor with its fitting (m) lmf C 0.645 0.645
Implantation for mast Imp V 2.8 2.8
Track swelling Ts C 0.1 0.1

Stagger (for tangent-Stagger=0 & for cuveture-Stagger=.2) St C 0.000 0.000

Curve allowance (Radius


Ca C 0.000 0.000
of curveture less than 875m Ca=.15, otherwise 0)
Length of lever arm for vertical load (m)
lv=Imp+wm/2+Ca+Ts+St V 2.98 2.98
Length of lever arm for Wind load on mast (m) lw C 4.075 4.075
Bending Moment due to wind load on Catenary wire wl1*l1 339.43 339.43
Bending Moment due to wind load on Contact wire wl2*l2 324.75 324.75
Bending Moment due to wind load on Earth wire 353.09 353.09
Bending Moment due to vertical load wto*lv 610.68 610.68
Bending Moment due to wind load on mast wlm*lw 700.17 700.17
Bending Moment due to radial tension in contact wire rt*l2 71.22 71.22
Bending Moment due to radial pull on cat wire rp1*l1 0.00 0.00
Bending Moment due to radial pull on contact wire rp2*l2 0.00 0.00
Bending Moment due to RC wlc*lr 0.00 0.00
Bending Moment due to weight of RC with its fittings wtrf*lmf 0.00 0.00
Total bending moment at the top of the foundation(kg-m) 2399 2399
Permissible Bending moment capacity of Masts (kg-m)
BFB 3444 3444
RSJ 5865 5865
B150, K150 4744 4744
B175, K175 6715 6715
B200, K200 8825 8825
B225, K225 11115 11115
B250, K250 13722 13722
Mast available at site at present BFB BFB
Permissible capacity of available at site 3444 3444
Mast available at site Passed or to be Replaced PASSED REPLACE PASSED PASSED
Type of foundation available at site at present BG-01 BG-02
FBM Code of above type of foundation 115 115
Permissible Bending moment capacity of foundation available at
1500 1500
site
Commissioning site condition (SIDE gravity TYPE, Side bearing
Side gravity Side gravity
type) Based on shoulder width at site
Side
Present site condition (SIDE gravity TYPE, Side bearing type) Based Side bearing
bearing
on shoulder width at site type
type
If present site condition is different from Commissioning ( i.e.
possibility of SIDE gravity TYPE changing to Side bearing type),then safer safer
it wil make old foundation further safe)
Foundation available at site Passed or to be Replaced REPLACE REPLACE

Note: 1. V=Variable, C = Constant


Note: 2. For foundation selection reffer drawings no.-
TI/DRG/CIV/FND/00001/13/0 (Sheet - 1 to 5)
72 67.5 63 58.5 54
72000 2500 2200 1900 1600

800 1000 1100 1200


800 1000 1100 1200

0 1

73 105 136 155 178

0 0.0199
0 0.652

0.125 0.152 0.175 0.200 0.225

0 14

37.1 52.1 37.392 42.91 48.904

0 1
0 8.96 9.605
0.645 0.695 1.35

0 0.2
0 0.15

0 0.01227
49.5 45 40.5 36
1400 1150 850 700 550 400

216

0.250

56.21 65.21
Checking of suitability of Normal mast (single cantilever assembly) Inside curve tarck for conventional OHE

Design data Symbol Remark Example value


span of OHE (m) s V 72.0 72.0
Radius of curvature of track (m) r V 2200 2200
versine of track v V 0.295 0.295
Tension in catenary wire (kgf) t1 V 1000 1000
Tension in contact wire (kgf) t2 V 1000 1000
Diameter-Catenary wire (m) d1 V 0.0105 0.0105
Diameter-Contact wire (m) d2 V 0.0122 0.0122
Diameter of Earth wire (m) V 0.01227 0.01227
Radial tension factor for contact wire
rtf V 0 0
(1 for tangent & 0 for curved track)
Radial tension in Contact wire rt V 0.00 0.00
Wind Pressure (kg/sq.m), IS:875 (Part-III) 2015, Navy blue-
wp V 73 73
73, Yellow-105, Blue-136, Green-155, Red-178
Unit weight of OHE (kg/m) wt C 1.60 1.60
Weight of man (kg) wtm C 60 60
Weight of cantiliver assembly (kg) wtb C 60 60
Diameter of Aluminium return conductor (m),
dr V 0.000 0.000
(if not in service =0)
Unit Weight of Aluminium return conductor (kg/m)
wtr V 0.000 0.000
(if not in service =0)
projected area factor for conductors a C 0.75 0.75
Wind load factor for droperss wlf C 1.05 1.05
Mast width along the track (m), BFB/RSJ-152, K/B125-125,
K/B150-150, K/B175-175, K/B200-200, K/B225-225, K/B250-250 wm V 0.15 0.15
(mm)
Height of mast above foundation level(m) hm C 8.15 8.15
Weight of return conductor fittings (kg)
wrf V 0.00 0.00
(if not in service =0)
Wind load factor on mast fm C 1.90 1.90
Weight of mast (kg/m) BFB-37.1, RSJ-52.1, K/B125-29.801,
K/B150-37.392, K/B175-42.91, K/B200-48.904, K/B225-56.21, wtm V 37.10 37.10
K/B250-65.21
Full length of mast (m) flm C 9.50 9.50
Radial pull Factor for tangent track-0, For curve track-1 V C 1.00 1.00
Radial pull in catenary Wire (kg) rp1=(s*t1/r) V 33 33
Radial pull in contact Wire (kg) rp2=(s*t2/r) V 33 33
Unit wind load on catenary wire-kg/m wlf1=d1*wp*a*wlf 0.60 0.60
Wind load on catenary wire wl1=wlf1*s 43.46 43.46
Unit wind load on contact wire-kg/m wlf2=d2*wp*a*wlf 0.70 0.70
Wind load on contact wire wl2=wlf2*s 50.66 50.66
Unite wind load on Earth wire V 0.67 0.67
Wind load on Earth wire 48.37 48.37
Wind load on Return conductor wlc=dr*wp*wlf*a*s 0.00 0.00
Wind load on mast wlm=wm*wp*hm*fm 171.82 171.82
Design vertical load of OHE (kg) wto=wt*s+wtm+wtb/2 205.20 205.20
Weight of Return conductor & fittings wtrf=wtr*s+wrf 0.00 0.00
Total Vertical load wto 205.20 205.20
Bending moment Calculation
Length of lever arm-catenary wire (m) l1 C 7.81 7.81
Length of lever arm-contact wire (m) l2 C 6.41 6.41
Length of lever arm for Earth wire l3 7.30 7.30
Length of lever arm for Return conductor (m) (if not
lr C 0.00 0.00
in service =0)
Length of lever arm for Reurn conductor with its fitting (m) lm C 0.645 0.645
Implantation for mast Imp V 2.8 2.8
Radius of curvature greate than or equal to 3500m C 0.40 0.40
Radius of curvature greate than or equal to 2350m but less than
C 0.55 0.55
3500m
Radius of curvature greate than or equal to 1150m but less than Ca
C 0.75 0.75
2350m
Radius of curvature greate than or equal to 300m but less than
C 0.80 0.80
1150m
Track swelling Ts C 0.1 0.1
Stagger (for tangent-Stagger=0 & for cuveture-Stagger=.2) St C 0.2 0.2
change
Length of lever arm for vertical load (m) lv=imp+ca+wm/2-Ts-St V 3.33 3.33 formula
Length of lever arm-Wind load on mast (m) lw C 4.075 4.075 as per Ca
Bending moment due to wind load on Catenary wire wl1*l1 V 339.43 339.43
Bending moment due to wind load on Contact wire wl2*l2 324.75 324.75
Bending Moment due to wind load on Earth wire 353.09 353.09
Bending moment due to vertical load wto*lv 682.50 682.50
Bending moment due to wind load on mast wlm*lw 700.17 700.17
Bending moment due to radial tension in contact wire rt*l2 0.00 0.00
Bending moment due to radial pull on catenary wire rp1*l1 -255.60 -255.60
Bending moment due to radial pull on contact wire rp2*l2 -209.78 -209.78
Bending moment due to RC wlc*lr 0.00 0.00
Bending moment due to mast fitting with RC wtrf*lm 0.00 0.00
Total bending moment at the top of the foundation(kg-m) 1935 1935
Permissible Bending moment capacity of Masts (kg-m)
BFB 3444 3444
RSJ 5865 5865
B150, K150 4744 4744
B175, K175 6715 6715
B200, K200 8825 8825
B225, K225 11115 11115
B250, K250 13722 13722
MAST AVAILABLE AT SITE AT PRESENT BFB BFB
Permissible capacity of Masts AVAILABLE AT SITE 3444 3444
MAST AVAILABLE AT SITE PASSED OR TO BE REPLACED PASSED REPLACE PASSED PASSED
TYPE OF FOUNDATION AVAILABLE AT SITE AT PRESENT BG-01 BG-01
FBM CODE OF ABOVE TYPE OF FOUNDATION 115 115
Permissible Bending moment capacity of foundation AVAILABLE AT
1500 1500
SITE
Commissioning SITE CONDITION (SIDE gravity TYPE, Side bearing Side
Side gravity
type) Based on shoulder width at site gravity
Side Side
Present SITE CONDITION (SIDE gravity TYPE, Side bearing type)
bearing bearing
Based on shoulder width at site
type type

IF PRESENT SITE CONDITION IS DIFFERENT FROM


COMMISSIONING ( i.e. possibility of SIDE gravity TYPE changing safer safer
to Side bearing type),then it wil make old foundation further safe)

FOUNDATION AVAILABLE AT SITE PASSED OR TO BE REPLACED REPLACE REPLACE

Note: 1. V=Variable, C = Constant


Note: 2. For foundation selection reffer drawings no.-
TI/DRG/CIV/FND/00001/13/0 (Sheet - 1 to 5)
Note:3. Difference between bending due to vetical and due to
radial pull, this will be added in bending moment due to wind force
in mast, catenary and contact wire.
72 67.5 63 58.5 54
72000 2500 2200 1900 1600

800 1000 1100 1200


800 1000 1100 1200

0 1

73 105 136 155 178

0 0.0199
0 0.652

0.125 0.152 0.175 0.200 0.225

0 14

37.1 52.1 37.392 42.91 48.904

0 1
0 8.96 9.605
0.645 0.695 1.35

0 0.2

0 0.01227
49.5 45 40.5 36
1400 1150 850 700 550 400

216

0.250

56.21 65.21
Checking of suitability of Anticreep Centre mast outside curve including tangent tarck for conventional OHE

Design data Symbol Remark example Value


span of OHE (m) s V 72 72
Radius of curvature of track (m) r V 72000 72000
versine v V 0.009 0.009
Tension-catenary wire (kgf) t1 V 1000 1000
Tension-contact wire (kgf) t2 V 1000 1000
Diameter-Catenary wire (m) d1 V 0.0105 0.0105
Diameter-Contact wire (m) d2 V 0.01224 0.01224
Diameter of Earth wire (m) 0.01227 0.01227
Diameter-Acc wire (m) d3 V 0.0125 0.0125
Radial tension factor for contact wire (1 for
rtf V 1 1
tangent & 0 for curved track)
Radial tension in Contact wire rt 11.111 11.111
Wind Pressure (kg/sq.m), IS:875 (Part-III) 2015, Navy
wp 73 73
blue-73, Yellow-105, Blue-136, Green-155, Red-178
Unit weight of OHE (kg/m) wt C 1.6 1.6
Unit weight of ACC wire uwtAcc C 0.73 0.73
Weight of man (kg) wtm C 60 60
Weight of cantiliver assembly (kg) wtb C 60 60
Diameter of Aluminium return conductor (m),
dr 0 0
(if not in service =0)
Unit Weight of Aluminium return conductor (kg/m)
wtr V 0 0
(if not in service =0)
projected area factor for conductors a C 0.75 0.75
Wind load factor for droperss wlf C 1.05 1.05
Mast width along the track (m),
BFB/RSJ-152, K/B125-125, K/B150-150, K/B175-175, K/B200-200, wm V 0.152 0.152
K/B225-225, K/B250-250
Height of mast above foundation level(m) hm C 8.15 8.15
Weight of return conductor fittings (kg)
wrf V 0 0
(if not in service =0)
Wind load factor on mast fm C 1.9 1.9

Weight of mast (kg/m) BFB-37.1, RSJ-52.1, K/B125-29.801, K/B150-


wtm V 37.1 37.1
37.392, K/B175-42.91, K/B200-48.904, K/B225-56.21, K/B250-65.21

Full length of mast (m) flm C 9.5 9.5


Tension in Anticreep wire Tacc V 800 800
Radial pull in ACC wire rpAcc V 60.89 60.89
Radial pull Factor for tangent track-0, For curve track-1 V C 0.00 0.00
Radial pull in catenary Wire (kg) (0 for tangent ) rp1=(s*t1/r) V 0 0
Radial pull in contact Wire (kg) (0 for tangent ) rp2=(s*t2/r) V 0 0
Height of anchoring (m) ha V 0 0
Wind load on counter weight (kg) wcw V 0 0
Design Calculation
Unit wind load on catenary wire-kg/m wlf1=d1*wp*a*wlf 0.60 0.60
Wind load on catenary wire wl1=wlf1*s 43.46 43.46
Unit wind load on contact wire-kg/m wlf2=d2*wp*a*wlf 0.70 0.70
Wind load on contact wire wl2=wlf2*s 50.66 50.66
Unite wind load on Earth wire V 0.67 0.67
Wind load on Earth wire V 48.37 48.37
Wind load on anticreep wire wlAcc= d3*s*wp*a 49.28 49.28
Wind load on Return conductor wlc=dr*wp*wlf*a*s 0.00 0.00
Wind load on mast wlm=wm*wp*hm*fm 171.82 171.82
Vertical Load
Weight of OHE (kg) wto=wt*s+wtm+wtb/2 V 205.2 205.2
Weight of Return conductor & fittings wtrf=wtr*s+wrf V 0 0
Weight of ACC wire (kg) wtacc=uwtAcc*s V 52.56 52.56
Total wto 257.76 257.76
Bending moment Calculation
Length of lever arm-catenary wire (m) l1 C 7.81 7.81
Length of lever arm-contact wire (m) l2 C 6.41 6.41
Length of lever arm for Earth wire l3 C 7.30 7.30
Length of lever arm for Return conductor (m) (if not
lr C
in service =0) 0 0
Length of lever arm for Reurn conductor with its fitting (m) lm C 0.645 0.645
Implantation for mast Imp. V 2.8 2.8
Track swelling Ts C 0.1 0.1
Stagger (for tangent St=0, & for cuveture St=.2) St C 0 0
Curve allowance
Ca C
(Radius of curveture less than 875m Ca=.15, otherwise 0) 0 0
Length of lever arm for vertical load (m)
lv=Imp+wm/2+Ts+St+ca V 2.976 2.976

Length of lever arm For Radial pull for ACC (m) lAcc=Imp+wm/2-Ts-4*v+Ca V
2.74 2.74
Length of lever arm-Wind load on mast (m) lw C 4.075 4.075
Bending Moment due to Catenary wire wl1*l1 339.43 339.43
Bending Moment due to Contact wire wl2*l2 324.75 324.75
Bending Moment due to wind load on Earth wire 353.09 353.09
Bending Moment due to vertical load wto*lv 767.09 767.09
Bending Moment due to wind load on mast wlm*lw 700.17 700.17
Bending Moment due to radial tension in contact wire rt*l2 71.22 71.22
Bending Moment due to radial pull on catenary wire rp1*l1 0.0 0.0
Bending Moment due to radial pull on contact wire rp2*l2 0.0 0.0
Bending Moment due to radial pull on ACC wire rpAcc*l1 -475.54 -475.54
Bending Moment due to wind load on anticreep wire wlAcc*l1 384.84 384.84
Bending Moment due to RC wlr*lr 0 0
Bending Moment due to mast fitting with Return conductor wtrf*lm 0 0
Bending Moment due to Radial tension due to anchored OHE pull ((((t1+t2)*lv)/s)*ha)
0 0
Bending Moment due to wind load on counter weights wcw*ha/2 0 0
Total bending moment (kg-m) 2465.0 2465.0
Permissible Bending moment capacity of Masts (kg-m)
BFB 4011 4011
RSJ 6674 6674
B150, K150 5053 5053
B175, K175 7032 7032
B200, K200 9140 9140
B225, K225 11413 11413
B250, K250 14008 14008
MAST AVAILABLE AT SITE AT PRESENT BFB BFB
Permissible capacity of Masts AVAILABLE AT SITE 4011 4011
MAST AVAILABLE AT SITE PASSED OR TO BE REPLACED PASSED REPLACE PASSED PASSED
TYPE OF FOUNDATION AVAILABLE AT SITE AT PRESENT BG-01 BG-01
FBM CODE OF ABOVE TYPE OF FOUNDATION 115 115
Permissible Bending moment capacity of foundation AVAILABLE AT
1500 1500
SITE
Commissioning SITE CONDITION (SIDE gravity TYPE, Side bearing
Side gravity Side gravity
type) Based on shoulder width at site
Side Side
Present SITE CONDITION (SIDE gravity TYPE, Side bearing type)
bearing bearing
Based on shoulder width at site
type type

IF PRESENT SITE CONDITION IS DIFFERENT FROM COMMISSIONING


( i.e. possibility of SIDE gravity TYPE changing to Side bearing safer safer
type),then it wil make old foundation further safe)

FOUNDATION AVAILABLE AT SITE PASSED OR TO BE REPLACED REPLACE REPLACE

Note: 1. V=Variable, C=Constant


Note: 2. For foundation selection reffer drawings no.-
TI/DRG/CIV/FND/00001/13/0 (Sheet - 1 to 5)
Note:3. Radial tension due to tension in the antcreep wire is
considered as negative.

72 67.5 63
72000 2500 2200

800 1000 1100


800 1000 1100
0 1

73 105 136

0 0.0199
0 0.652

0.125 0.152 0.175

0 14

37.1 52.1 37.392

0 1

0 0.2
0 0.15

0 8.96 9.605
0.645 0.695 1.35

0 0.01227
58.5 54 49.5 45 40.5 36
1900 1600 1400 1150 850 700 550 400

1200
1200
155 178 216

0.200 0.225 0.250

42.91 48.904 56.21 65.21


Checking of suitability of Anticreep Centre mast Inside curve tarck for conventional OHE

Design data Symbol Remark Example Value


span of OHE (m) s V 72 72
Radius of curvature of track (m) r V 2200 2200
versine v V 0.295 0.295
Tension-catenary wire (kgf) t1 V 1000 1000
Tension-contact wire (kgf) t2 V 1000 1000
Diameter-Catenary wire (m) d1 V 0.0105 0.0105
Diameter-Contact wire (m) d2 V 0.01224 0.01224
Diameter of Earth wire (m) V 0.01227 0.01227
Radial tension factor for contact wire (1 for
rtf V 0 0
tangent & 0 for curved track)
Radial tension in Contact wire rt 0 0
Wind Pressure (kg/sq.m), IS:875 (Part-III) 2015, Navy blue-
wp 73 73
73, Yellow-105, Blue-136, Green-155, Red-178
Unit weight of OHE (kg/m) wt C 1.6 1.6
Unit weight of ACC wire uwtAcc C 0.73 0.73
Weight of man (kg) wtm C 60 60
Weight of cantiliver assembly (kg) wtb C 60 60
Diameter of Aluminium return conductor (m),
dr 0 0
(if not in service =0)
Unit Weight of Aluminium return conductor (kg/m)
wtr V 0 0
(if not in service =0)
projected area factor for conductors a C 0.75 0.75
Tension in Anticreep wire Tacc V 800 800
Wind load factor for droperss wlf C 1.05 1.05
Mast width along the track (m),
BFB/RSJ-152, K/B125-125, K/B150-150, K/B175-175, K/B200-200, wm V 0.152 0.152
K/B225-225, K/B250-250
Height of mast above foundation level(m) hm C 8.15 8.15
Weight of return conductor fittings (kg)
wrf V 0 0
(if not in service =0)
Wind load factor on mast fm C 1.9 1.9

Weight of mast (kg/m) BFB-37.1, RSJ-52.1, K/B125-29.801, K/B150-


wtm V 37.1 37.1
37.392, K/B175-42.91, K/B200-48.904, K/B225-56.21, K/B250-65.21

Full length of mast (m) flm C 9.5 9.5


Radial Tension in ACC wire rtAcc V 54.49 54.49
Radial pull in ACC wire rpAcc V 108.98 108.98
Radial pull Factor for tangent track-0, For curve track-1 V C 1.00 1.00
Radial pull in catenary Wire (kg) (0 for tangent ) rp1=V*(s*t1/r) V 32.73 32.73
Radial pull in contact Wire (kg) (0 for tangent ) rp2=V*(s*t2/r) V 32.73 32.73
Height of anchoring (m) ha V 0 0
Wind load on counter weight (kg) wcw V 0 0
Design Calculation
Unit wind load on catenary wire-kg/m wlf1=d1*wp*a*wlf 0.60 0.60
Wind load on catenary wire wl1=wlf1*s 43.46 43.46
Unit wind load on contact wire-kg/m wlf2=d2*wp*a*wlf 0.70 0.70
Wind load on contact wire wl2=wlf2*s 50.66 50.66
Unite wind load on Earth wire V 0.67 0.67
Wind load on Earth wire V 48.37 48.37
Due to Wind load on anticreep wire wlAcc= .0125*s*wp*a 49.28 49.28
Wind load on Return conductor wlc=dr*wp*wlf*a*s 0.00 0.00
Wind load on mast wlm=wm*wp*hm*fm 171.82 171.82
Vertical Load
Weight of OHE (kg) wto=wt*s+wtm+wtb/2 V 205.2 205.2
Weight of Return conductor & fittings wtrf=wtr*s+wrf V 0 0
Weight of ACC wire (kg) wtacc=uwtAcc*s V 52.56 52.56
Total wto 257.76 257.76
Bending moment Calculation
Length of lever arm-catenary wire (m) l1 C 7.81 7.81
Length of lever arm-contact wire (m) l2 C 6.41 6.41
Length of lever arm for Earth wire l3 C 7.30 7.30
Length of lever arm for Return conductor (m) (if not
lr V
in service =0) 0 0
Length of lever arm for Reurn conductor with its fitting (m) lm V 0.645 0.645
Implantation for mast Imp V 2.8 2.8
Radius of curvature greate than or equal to 3500m C 0.4 0.4

Radius of curvature greate than or equal to 2350m but less than 3500m C
0.55 0.55
Ca
Radius of curvature greate than or equal to 1150m but less than 2350m C
0.75 0.75

Radius of curvature greate than or equal to 300m but less than 1150m C
0.8 0.8
Track swelling Ts C 0.1 0.1
Stagger St C 0.2 0.2
Length of lever arm-vertical load (m) lv=Imp+Ca+wm/2-Ts-St V 3.326 3.326 change formula as per Ca
Length of lever arm For Radial pull for ACC (m) lAcc=Imp+Ca+wm/2+Ts+4*v V 4.904 4.904 change formula as per Ca
Length of lever arm-Wind load on mast (m) lw C 4.075 4.075
Bending Moment due to Catenary wire wl1*l1 339.4268955339.4268955
Bending Moment due to Contact wire wl2*l2 324.7471634324.7471634
Bending Moment due to wind load on Earth wire 353.09 353.09
Bending Moment due to vertical load wto*lv -857.30976 -857.30976
Bending Moment due to wind load on mast wlm*lw 700.172857 700.172857
Bending Moment due to radial tension in contact wire rt*l2 0 0
Bending Moment due to radial pull on catenary wire rp1*l1 255.6 255.6
Bending Moment due to radial pull on contact wire rp2*l2 209.7818182209.7818182
Bending Moment due to radial pull on ACC wire rpAcc*l1 851.148 851.148
Bending Moment due to wind load on anticreep wire wlAcc*l1 384.83775 384.83775
Bending Moment due to RC wlc*lr 0 0
Bending Moment due to mast fitting with Return conductor wtrf*lm 0 0
Bending Moment due to Radial tension due to anchored OHE pull ((((t1+t2)*lv)/s)*ha) 0 0
Bending Moment due to wind load on counter weights wcw*ha/2 0 0
Total bending moment (kg-m) 2561.493602561.493606
Permissible Bending moment capacity of Masts (kg-m)
BFB 4011 4011
RSJ 6674 6674
B150, K150 5053 5053
B175, K175 7032 7032
B200, K200 9140 9140
B225, K225 11413 11413
B250, K250 14008 14008
MAST AVAILABLE AT SITE AT PRESENT BFB BFB
Permissible capacity of Masts AVAILABLE AT SITE 4011 4011
MAST AVAILABLE AT SITE PASSED OR TO BE REPLACED PASSED REPLACE PASSED PASSED
TYPE OF FOUNDATION AVAILABLE AT SITE AT PRESENT BG-01 BG-01
FBM CODE OF ABOVE TYPE OF FOUNDATION 115 115
Permissible Bending moment capacity of foundation AVAILABLE AT SITE 1500 1500

Commissioning SITE CONDITION (SIDE gravity TYPE, Side bearing


Side gravity Side gravity
type) Based on shoulder width at site
Side
Present SITE CONDITION (SIDE gravity TYPE, Side bearing type) Based Side bearing
bearing
on shoulder width at site type
type

IF PRESENT SITE CONDITION IS DIFFERENT FROM COMMISSIONING


( i.e. possibility of SIDE gravity TYPE changing to Side bearing safer safer
type),then it wil make old foundation further safe)

FOUNDATION AVAILABLE AT SITE PASSED OR TO BE REPLACED REPLACE REPLACE

Note: 1. V=Variable, C=Constant


Note: 2. For foundation selection reffer drawings no.-
TI/DRG/CIV/FND/00001/13/0 (Sheet - 1 to 5)
Note:3. Difference between bending due to vetical and due to radial
pull, this will be added in bending moment due to wind force in mast, 72 67.5 63 58.5
catenary and contact wire.
72000 2500 2200 1900
800 1000 1100 1200
800 1000 1100 1200

0 1

73 105 136 155

0 0.0199
0 0.652

0.125 0.152 0.175 0.200

0 14

37.1 52.1 37.392 42.91

0 1

0 8.96 9.605
0.645 0.695 1.35
0 0.01227
mula as per Ca
mula as per Ca
54 49.5 45 40.5 36

1600 1400 1150 850 700 550 400


178 216

0.225 0.250

48.904 56.21 65.21


Checking of suitability of Anticreep Anchor mast outside curve including tangent tarck for conventional OHE

Design data Symbol Remarks Example Example


span of OHE (m) s V 72 72
Radius of curvature of track (m) r V 72000 72000
versine v V 0.009 0.009
Tension-catenary wire (kgf) t1 V 1000 1000
Tension-contact wire (kgf) t2 V 1000 1000
Diameter-Catenary wire (m) d1 V 0.01050 0.01050
Diameter-Contact wire (m) d2 V 0.01224 0.01224
Diameter of Earth wire (m) 0.01227 0.01227
Diameter-Acc wire (m) d3 V 0.0125 0.0125
Radial tension factor for contact wire (1 for
rtf V 1 1
tangent & 0 for curved track)
Radial tension in Contact wire rt 11.1 11.1
Wind Pressure (kg/sq.m), IS:875 (Part-III) 2015, Navy blue-
wp 73 73
73, Yellow-105, Blue-136, Green-155, Red-178
Unit weight of OHE (kg/m) wt C 1.600 1.600
Unit weight of ACA wire uwtAcc C 0.730 0.730
Weight of man (kg) wtm C 60 60
Weight of cantiliver assembly (kg) wtb C 60 60
Diameter of Aluminium return conductor (m),
dr V 0.0 0.0
(if not in service =0)
Unit Weight of Aluminium return conductor (kg/m)
wtr V 0.0 0.0
(if not in service =0)
projected area factor for conductors a C 0.75 0.75
Tension in Anticreep wire TAcc V 800 800
Wind load factor for droperss wlf C 1.05 1.05
Mast width along the track (m),
BFB/RSJ-152, K/B125-125, K/B150-150, K/B175-175, K/B200-200, wm V 0.152 0.152
K/B225-225, K/B250-250
Height of mast above foundation level(m) hm C 8.15 8.15
Weight of return conductor fittings (kg)
wrf V 0.0 0.0
(if not in service =0)
Wind load factor on mast fm C 1.9 1.9

Weight of mast (kg/m) BFB-37.1, RSJ-52.1, K/B125-29.801, K/B150-


wtm V 37.1 37.1
37.392, K/B175-42.91, K/B200-48.904, K/B225-56.21, K/B250-65.21

Full length of mast (m) flm C 9.5 9.5


Radial pull in ACA wire rpAca=Taca*Iaca/s V 33.5 33.5
Radial pull Factor for tangent track-0, For curve track-1 V C 0.00 0.00
Radial pull in catenary Wire (kg) (0 for tangent ) rp1=(s*t1/r) V 0.0 0.0
Radial pull in contact Wire (kg) (0 for tangent ) rp2=(s*t2/r) V 0.0 0.0
Height of anchoring (m) ha V 0.0 0.0
Wind load on counter weight (kg) wcw V 0.0 0.0
Design Calculation
Unit wind load on catenary wire-kg/m wlf1=d1*wp*a*wlf 0.604 0.604
Wind load on catenary wire wl1=wlf1*s 43.461 43.461
Unit wind load on contact wire-kg/m wlf2=d2*wp*a*wlf 0.704 0.704
Wind load on contact wire wl2=wlf2*s 50.663 50.663
Unite wind load on Earth wire V 0.67 0.67
Wind load on Earth wire V 48.37 48.37
Due to Wind load on anticreep anchor wire wlAca= d3*s*wp*a 49.275 49.275
Wind load on Return conductor wlc=dr*wp*wlf*a*s 0.000 0.000
Wind load on mast wlm=wm*wp*hm*fm 171.822 171.822
Vertical Load
Weight of OHE (kg) wto=wt*s+wtm+wtb/2 205.200 205.200
Weight of Return conductor & fittings wtrf=wtr*s+wrf 0.000 0.000
Weight of ACC wire (kg) wtacc=uwtAcc*s 26.280 26.280
Total vertical load wto 231.48 231.48
Bending moment Calculation
Length of lever arm anchor wire (m) la C 7.56 7.56
Length of lever arm-catenary wire (m) l1 C 7.81 7.81
Length of lever arm-contact wire (m) l2 C 6.41 6.41
Length of lever arm for Earth wire l3 C 7.30 7.30
Length of lever arm for Return conductor (m) (if not in
lr C 0.00 0.00
service =0)
Length of lever arm for Reurn conductor with its fitting (m) lm C 0.645 0.645
Implantation for mast Imp. V 2.80 2.80
Track swelling Ts C 0.1 0.1
Stagger (for tangent St=0, & for cuveture St=.2) St C 0.0 0.0
Curve allowance (Radius
Ca C 0.00 0.00
of curveture less than 875m Ca=.15, otherwise 0)
Length of lever arm for vertical load (m)
lv=Imp+wm/2+Ts+St+Ca V 2.976 2.976
Length of lever arm For Radial pull for ACA (m) lAca=Imp+wm/2+Ts+St+Ca V 3.012 3.012
Length of lever arm-Wind load on mast (m) lw C 4.075 4.075
Bending Moment due to Catenary wire wl1*l1 339.427 339.427
Bending Moment due to Contact wire wl2*l2 324.747 324.747
Bending Moment due to wind load on Earth wire 353.09 353.09
Bending Moment due to vertical load wto*lv 688.884 688.884
Bending Moment due to wind load on mast wlm*lw 700.173 700.173
Bending Moment due to radial tension in contact wire rt*l2 71.222 71.222
Bending Moment due to radial pull on catenary wire rp1*l1 0.000 0.000
Bending Moment due to radial pull on contact wire rp2*l2 0.000 0.000
Bending Moment due to radial pull on ACA wire rpAca*l1 100.802 100.802
Bending Moment due to wind load on anticreep anchor wire wlAca*l1 384.838 384.838
Bending Moment due to RC wlc*lr 0.000 0.000
Bending Moment due to mast fitting with Return conductor wtrf*lm 0.000 0.000
Bending Moment due to Radial tension due to anchored OHE pull ((((t1+t2)*lv)/s)*ha) 0.000 0.000
Bending Moment due to wind load on counter weights wcw*ha/2 0.000 0.000
Total bending moment (kg-m) 2963 2963
Permissible Bending moment capacity of Masts (kg-m)
BFB 3760 3760
RSJ 6312 6312
B150, K150 4908 4908
B175, K175 6893 6893
B200, K200 9007 9007
B225, K225 11286 11286
B250, K250 13884 13884
MAST AVAILABLE AT SITE AT PRESENT BFB BFB
Permissible capacity of Masts AVAILABLE AT SITE 3760 3760
MAST AVAILABLE AT SITE PASSED OR TO BE REPLACED PASSED REPLACE PASSED PASSED
TYPE OF FOUNDATION AVAILABLE AT SITE AT PRESENT BG-01 BG-01
FBM CODE OF ABOVE TYPE OF FOUNDATION 115 115
Permissible Bending moment capacity of foundation AVAILABLE AT SITE 1500 1500

Commissioning SITE CONDITION (SIDE gravity TYPE, Side bearing type) Side
Side gravity
Based on shoulder width at site gravity
Side
Present SITE CONDITION (SIDE gravity TYPE, Side bearing type) Based Side bearing
bearing
on shoulder width at site type
type

IF PRESENT SITE CONDITION IS DIFFERENT FROM COMMISSIONING


( i.e. possibility of SIDE gravity TYPE changing to Side bearing safer safer
type),then it wil make old foundation further safe)

FOUNDATION AVAILABLE AT SITE PASSED OR TO BE REPLACED REPLACE REPLACE


Note: 1. V=Variable, C=Constant
Note: 2. For foundation selection reffer drawings no.-
TI/DRG/CIV/FND/00001/13/0 (Sheet - 1 to 5)

72 67.5 63
72000 2500 2200

800 1000 1100


800 1000 1100

0 1

73 105 136

0 0.0199
0 0.652

0.125 0.152 0.175

0 14

37.1 52.1 37.392

0 1

0 0.2
0 0.15
0 8.96 9.605
0.645 0.695 1.35

0 0.01227
58.5 54 49.5 45 40.5 36
1900 1600 1400 1150 850 700 550 400

1200
1200

155 178 216

0.200 0.225 0.250

42.91 48.904 56.21 65.21


Checking of suitability of Anticreep Anchor mast inside curve tarck for conventional OHE

Design data Symbol Remarks Example Example


span of OHE (m) s V 67.5 67.5
Radius of curvature of track (m) r V 2200 2200
versine v V 0.259 0.259
Tension-catenary wire (kgf) t1 V 1000 1000
Tension-contact wire (kgf) t2 V 1000 1000
Diameter-Catenary wire (m) d1 V 0.01050 0.01050
Diameter-Contact wire (m) d2 V 0.01224 0.01224
Diameter of Earth wire (m) V 0.01227 0.01227
Diameter-Acc wire (m) d3 V 0.0125 0.0125
Radial tension factor for contact wire (1 for
rtf V 0 0
tangent & 0 for curved track)
Radial tension in Contact wire rt 0 0
Wind Pressure (kg/sq.m), IS:875 (Part-III) 2015, Navy blue-
wp 73 73
73, Yellow-105, Blue-136, Green-155, Red-178
Unit weight of OHE (kg/m) wt C 1.6 1.6
Unit weight of ACC wire uwtAca C 0.73 0.73
Weight of man (kg) wtm C 60 60
Weight of cantiliver assembly (kg) wtb C 60 60
Diameter of Aluminium return conductor (m),
dr 0 0
(if not in service =0)
Unit Weight of Aluminium return conductor (kg/m)
wtr V 0 0
(if not in service =0)
projected area factor for conductors a C 0.75 0.75
Tension in Anticreep wire Tacc V 800 800
Wind load factor for droperss wlf C 1.05 1.05
Mast width along the track (m),
BFB/RSJ-152, K/B125-125, K/B150-150, K/B175-175, K/B200-200, wm V 0.152 0.152
K/B225-225, K/B250-250
Height of mast above foundation level(m) hm C 8.15 8.15
Weight of return conductor fittings (kg)
wrf V 0 0
(if not in service =0)
Wind load factor on mast fm C 1.9 1.9

Weight of mast (kg/m) BFB-37.1, RSJ-52.1, K/B125-29.801, K/B150-


wtm V 37.1 37.1
37.392, K/B175-42.91, K/B200-48.904, K/B225-56.21, K/B250-65.21

Full length of mast (m) flm C 9.5 9.5


Radial pull in ACA wire rpAca=Taca*Iaca/s V 29.517 29.517
Radial pull Factor for tangent track-0, For curve track-1 V C 1.00 1.00
Radial pull in catenary Wire (kg) rp1=(s*t1/r) V 30.7 30.7
Radial pull in contact Wire (kg) rp2=(s*t2/r) V 30.7 30.7
Height of anchoring (m) ha V 0 0
Wind load on counter weight (kg) wcw V 0 0
Unit wind load on catenary wire-kg/m wlf1=d1*wp*a*wlf 0.60 0.60
Wind load on catenary wire wl1=wlf1*s 40.74 40.74
Unit wind load on contact wire-kg/m wlf2=d2*wp*a*wlf 0.70 0.70
Wind load on contact wire wl2=wlf2*s 47.50 47.50
Unite wind load on Earth wire V 0.67 0.67
Wind load on Earth wire V 45.35 45.35
Due to Wind load on anticreep anchor wire wlAcc=d3*s*wp*a 23.10 23.10
Wind load on Return conductor wlc=dr*wp*wlf*a*s 0.00 0.00
Wind load on mast wlm=wm*wp*hm*fm 171.82 171.82
Wind load on mast fittings wlmf 16 16
Vertical Load
Weight of OHE (kg) wto=wt*s+wtm+wtb/2 198 198
Weight of Return conductor & fittings wtrf=wtr*s+wrf 0 0
Weight of ACC wire (kg) wtaca=uwtAca*s 24.64 24.64
Total vertical load wto 222.6375 222.6375
Bending moment Calculation
Length of lever arm anchor wire (m) lAca C 7.56 7.56
Length of lever arm-catenary wire (m) l1 C 7.81 7.81
Length of lever arm-contact wire (m) l2 C 6.41 6.41
Length of lever arm for Earth wire l3 C 7.30 7.30
Length of lever arm for Return conductor (m) (if not in
lr C
service =0) 0 0
Length of lever arm for Reurn conductor with its fitting (m) lm C 0.645 0.645
Implantation for mast Imp V 2.8 2.8
Radius of curvature greate than or equal to 3500m C 0.4 0.4

Radius of curvature greate than or equal to 2350m but less than 3500m C
0.55 0.55
Ca
Radius of curvature greate than or equal to 1150m but less than 2350m C
0.75 0.75

Radius of curvature greate than or equal to 300m but less than 1150m C
0.8 0.8
Track swelling Ts C 0.1 0.1
Stagger
St C
(Radius of curveture less than 875m St=.2, otherwise 0) 0 0
Length of lever arm-vertical load (m) lv=Imp+Ca+wm/2-Ts-St V 3.526 3.526 change formula as per Ca
lAca=Imp+Ca+wm/2-Ts-St-
Length of lever arm For Radial pull for ACA (m) V change formula as per Ca
4*v 2.490 2.490
Length of lever arm-Wind load on mast (m) lw C 4.075 4.075
Bending Moment due to Catenary wire wl1*l1 318.21 318.21
Bending Moment due to Contact wire wl2*l2 304.450 304.450
Bending Moment due to wind load on Earth wire 331.02 331.02
Bending Moment due to vertical load wto*lv 785.02 785.02
Bending Moment due to wind load on mast wlm*lw 700.17 700.17
Bending Moment due to radial tension in contact wire rt*l2 0.00 0.00
Bending Moment due to radial pull on catenary wire rp1*l1 -239.63 -239.63
Bending Moment due to radial pull on contact wire rp2*l2 -196.67 -196.67
Bending Moment due to radial pull on ACA wire rpAca*lAca -223.15 -223.15
Bending Moment due to wind load on ACA wire wlAca*lAca 174.618 174.618
Bending Moment due to RC wlc*lr 0 0
Bending Moment due to mast fitting with Return conductor wtrf*lm 0 0
Bending Moment due to Radial tension due to anchored OHE pull ((((t1+t2)*lv)/s)*ha) 0 0
Bending Moment due to wind load on counter weights wcw*ha/2 0 0
Bending Moment due to mast fitting wlmf*lAca 120.96 120.96
Total bending moment (kg-m) 2075.01 2075.01
Permissible Bending moment capacity of Masts (kg-m)
BFB 3760 3760
RSJ 6312 6312
B150, K150 4908 4908
B175, K175 6893 6893
B200, K200 9007 9007
B225, K225 11286 11286
B250, K250 13884 13884
MAST AVAILABLE AT SITE AT PRESENT BFB BFB
Permissible capacity of Masts AVAILABLE AT SITE 3760 3760
MAST AVAILABLE AT SITE PASSED OR TO BE REPLACED PASSED REPLACE PASSED PASSED
TYPE OF FOUNDATION AVAILABLE AT SITE AT PRESENT BG-01 BG-01
FBM CODE OF ABOVE TYPE OF FOUNDATION 115 115
Permissible Bending moment capacity of foundation AVAILABLE AT SITE 1500 1500

Commissioning SITE CONDITION (SIDE gravity TYPE, Side bearing type) Side
Side gravity
Based on shoulder width at site gravity
Side Side
Present SITE CONDITION (SIDE gravity TYPE, Side bearing type) Based
bearing bearing
on shoulder width at site
type type

IF PRESENT SITE CONDITION IS DIFFERENT FROM COMMISSIONING


( i.e. possibility of SIDE gravity TYPE changing to Side bearing safer safer
type),then it wil make old foundation further safe)

FOUNDATION AVAILABLE AT SITE PASSED OR TO BE REPLACED REPLACE REPLACE

Note: 1. V=Variable, C=Constant


Note: 2. For foundation selection reffer drawings no.-
TI/DRG/CIV/FND/00001/13/0 (Sheet - 1 to 5)
Note:3. Difference between bending due to vetical and due to radial pull,
this will be added in bending moment due to wind force in mast,
catenary and contact wire.

72 67.5 63 58.5
72000 2500 2200 1900

800 1000 1100 1200


800 1000 1100 1200

0 1

73 105 136 155

0 0.0199
0 0.652

0.125 0.152 0.175 0.200

0 14

37.1 52.1 37.392 42.91

0 1
0 8.96 9.605
0.645 0.695 1.35

0 0.2

0 0.01227
rmula as per Ca

rmula as per Ca
54 49.5 45 40.5 36
1600 1400 1150 850 700 550 400

178 216

0.225 0.250

48.904 56.21 65.21


Checking of suitability of Overlap Anchor mast outside curve including tangent tarck for conventional OHE

Design data Symbol Remarks Example value


span of OHE (m) s V 72.0 72.0
Radius of curvature of track (m) r V 72000 72000
versine v V 0.009 0.009
Tension-catenary wire (kgf) t1 V 1000 1000
Tension-contact wire (kgf) t2 V 1000 1000
Diameter-Catenary wire (m) d1 V 0.0105 0.0105
Diameter-Contact wire (m) d2 V 0.01224 0.01224
Diameter of Earth wire (m) 0.01227 0.01227
Radial tension factor for contact wire (1 for
rtf V 0 0
tangent & 0 for curved track)
Radial tension in Contact wire rt 0.000 0.000
Wind Pressure (kg/sq.m), IS:875 (Part-III) 2015, Navy blue-
wp 73 73
73, Yellow-105, Blue-136, Green-155, Red-178
Unit weight of OHE (kg/m) wt C 1.6 1.6
Weight of man (kg) wtm C 60 60
Weight of cantiliver assembly (kg) wtb C 60 60
Diameter of Aluminium return conductor (m),
dr 0.0 0.0
(if not in service =0)
Unit Weight of Aluminium return conductor (kg/m)
wtr V 0.0 0.0
(if not in service =0)
projected area factor for conductors a C 0.75 0.75
Tension in Anticreep wire Tacc V 1300 1300
Wind load factor for droperss wlf C 1.05 1.05
Mast width along the track (m),
BFB/RSJ-152, K/B125-125, K/B150-150, K/B175-175, K/B200-200, wm V 0.152 0.152
K/B225-225, K/B250-250
Height of mast above foundation level(m) hm C 8.150 8.150
Weight of return conductor fittings (kg)
wrf V 0.0 0.0
(if not in service =0)
Wind load factor on mast fm C 1.9 1.9

Weight of mast (kg/m) BFB-37.1, RSJ-52.1, K/B125-29.801, K/B150-


wtm V 37.1 37.1
37.392, K/B175-42.91, K/B200-48.904, K/B225-56.21, K/B250-65.21

Full length of mast (m) flm C 9.5 9.5


Radial pull Factor for tangent track-0, For curve track-1 V C 0.00 0.00
Radial pull in catenary Wire (kg) (0 for tangent ) rp1=(s*t1/r) V 0.0 0.0
Radial pull in contact Wire (kg) (0 for tangent ) rp2=(s*t2/r) V 0.0 0.0
Design Calculation
Unit wind load on catenary wire-kg/m wlf1=d1*wp*a*wlf 0.604 0.604
Wind load on catenary wire wl1=wlf1*s 43.461 43.461
Unit wind load on contact wire-kg/m wlf2=d2*wp*a*wlf 0.704 0.704
Wind load on contact wire wl2=wlf2*s 50.663 50.663
Unite wind load on Earth wire V 0.67 0.67
Wind load on Earth wire V 48.37 48.37
Wind load on Anchord OHE wlAohe= (wlf1+wlf2)*s/2 47.062 47.062
Wind load on Return conductor wlc=dr*wp*wlf*a*s 0.0 0.0
Wind load on mast wlm=wm*wp*hm*fm 171.822 171.822
Wind load on counter weight (kg) wcw V 50 50
Vertical Load
Weight of OHE (kg) wto=wt*s+wtm+wtb/2 205.20 205.20
Weight of Return conductor & fittings wtrf=wtr*s+wrf 0.000 0.000
Total vertical load wto 205.200 205.200
Bending moment Calculation
Length of lever arm anchored wire (m) ha 7.56 7.56
Length of lever arm-catenary wire (m) l1 C 7.81 7.81
Length of lever arm-contact wire (m) l2 C 6.41 6.41
Length of lever arm for Earth wire l3 C 7.30 7.30
Length of lever arm for Return conductor (m) (if not in
lr C 0.00 0.00
service =0)
Length of lever arm for Reurn conductor with its fitting (m) lm C 0.645 0.645
Implantation for mast Imp. V 2.80 2.80
Track swelling Ts C 0.1 0.1
Stagger (for tangent-Stagger=0 & for cuveture-Stagger=.2) St C 0.0 0.0
Curve allowance (Radius of
Ca C 0.00 0.00
curveture less than 875m Ca=.15, otherwise 0)
Panto Intagalment X C 0.66 0.66
Length of lever arm for vertical load (m)
lv=Imp+wm/2+Ts+St V 2.976 2.976
lAohe=Imp+wm/
Length of lever arm For Radial pull for OLA (m) V 3.672 3.672
2+Ts+Ca+X+4*v
Length of lever arm-Wind load on mast (m) lw C 4.075 4.075
Bending Moment due to Catenary wire wl1*l1 339.427 339.427
Bending Moment due to Contact wire wl2*l2 324.747 324.747
Bending Moment due to wind load on Earth wire 353.09 353.09
Bending Moment due to vertical load wto*lv 610.675 610.675
Bending Moment due to wind load on mast wlm*lw 700.173 700.173
Bending Moment due to radial tension in contact wire rt*l2 0.000 0.000
Bending Moment due to radial pull on catenary wire rp1*l1 0.000 0.000
Bending Moment due to radial pull on contact wire rp2*l2 0.000 0.000
Bending Moment due to RC wlc*lr 0.000 0.000
Bending Moment due to mast fitting with Return conductor wtrf*lm 0.000 0.000
Bending Moment due to Radial pull on anchored OHE pull ((((t1+t2)*lv)/s)*ha) 771.095 771.095
Bending Moment due to wind load on anchored OHE wlAohe*ha 355.785 355.785
Bending Moment due to wind load on counter weights wcw*ha/2 189 189
Bending Moment due to anchor pully 65*ha 491 491
Total bending moment (kg-m) 4135 4135
Permissible Bending moment capacity of Masts (kg-m)
BFB 3370 3370
RSJ 5748 5748
B150, K150 4681 4681
B175, K175 6677 6677
B200, K200 8800 8800
B225, K225 11088 11088
B250, K250 13691 13691
MAST AVAILABLE AT SITE AT PRESENT BFB BFB
Permissible capacity of Masts AVAILABLE AT SITE 3370 3370
MAST AVAILABLE AT SITE PASSED OR TO BE REPLACED PASSED REPLACE REPLACE REPLACE
Type of foundation available at site at present BG-01 BG-01
FBM Code of above type of foundation 115 115
Permissible Bending moment capacity of foundation available at site 1500 1500

Commissioning site condition (SIDE gravity TYPE, Side bearing type)


Side gravity Side gravity
Based on shoulder width at site

Present site condition (SIDE gravity TYPE, Side bearing type) Based on Side bearing Side bearing
shoulder width at site type type

If present site condition is different from Commissioning ( i.e. possibility


of SIDE gravity TYPE changing to Side bearing type),then it wil make old safer safer
foundation further safe)
Foundation available at site Passed or to be Replaced REPLACE REPLACE
Note: 1. V=Variable, C = Constant
Note: 2. For foundation selection reffer drawings no.-
TI/DRG/CIV/FND/00001/13/0 (Sheet - 1 to 5)

72 67.5 63 58.5
72000 2200 1900 1600

800 1000 1100 1200


800 1000 1100 1200
0 1

73 105 136 155

0 0.0199
0 0.652

0.125 0.152 0.175 0.200

0 14

37.1 52.1 37.392 42.91

0 1

0 8.96 9.605
0.645 0.695 1.35

0 0.2
0 0.15
0 0.01227
54 49.5 45 40.5 36
1400 1150 850 700 550 400
178 216

0.225 0.250

48.904 56.21 65.21


Checking of suitability of Overlap Anchor mast Inside curve tarck for conventional OHE

Design data Symbol Remarks Example Example


span of OHE (m) s V 72.0 72.0
Radius of curvature of track (m) r V 2200 2200
versine v V 0.295 0.295
Tension-catenary wire (kgf) t1 V 1000 1000
Tension-contact wire (kgf) t2 V 1000 1000
Diameter-Catenary wire (m) d1 V 0.0105 0.0105
Diameter-Contact wire (m) d2 V 0.0122 0.0122
Diameter of Earth wire (m) V 0.01227 0.01227
Radial tension factor for contact wire (1 for
rtf V 1 1
tangent & 0 for curved track)
Radial tension in Contact wire rt 11 11
Wind Pressure (kg/sq.m), IS:875 (Part-III) 2015, Navy blue-
wp 73 73
73, Yellow-105, Blue-136, Green-155, Red-178
Unit weight of OHE (kg/m) wt C 1.6 1.6
Weight of man (kg) wtm C 60 60
Weight of cantiliver assembly (kg) wtb C 60 60
Diameter of Aluminium return conductor (m),
dr 0.0 0.0
(if not in service =0)
Unit Weight of Aluminium return conductor (kg/m)
wtr V 0.0 0.0
(if not in service =0)
projected area factor for conductors a C 0.75 0.75
Tension in Anticreep wire Taca V 1300 1300
Wind load factor for droperss wlf C 1.050 1.050
Mast width along the track (m),
BFB/RSJ-152, K/B125-125, K/B150-150, K/B175-175, K/B200-200, wm V 0.152 0.152
K/B225-225, K/B250-250
Height of mast above foundation level(m) hm C 8.150 8.150
Weight of return conductor fittings (kg)
wrf V 0.0 0.0
(if not in service =0)
Wind load factor on mast fm C 1.9 1.9

Weight of mast (kg/m) BFB-37.1, RSJ-52.1, K/B125-29.801, K/B150-


wtm V 37.1 37.1
37.392, K/B175-42.91, K/B200-48.904, K/B225-56.21, K/B250-65.21

Full length of mast (m) flm C 9.5 9.5


Radial pull Factor for tangent track-0, For curve track-1 V C 0.00 0.00
Radial pull in catenary Wire (kg) (0 for tangent ) rp1=(s*t1/r) V 0.0 0.0
Radial pull in contact Wire (kg) (0 for tangent ) rp2=(s*t2/r) V 0.0 0.0
Design Calculation
Unit wind load on catenary wire-kg/m wlf1=d1*wp*a*wlf 0.604 0.604
Wind load on catenary wire wl1=wlf1*s 43.461 43.461
Unit wind load on contact wire-kg/m wlf2=d2*wp*a*wlf 0.704 0.704
Wind load on contact wire wl2=wlf2*s 50.663 50.663
Unite wind load on Earth wire V 0.67 0.67
Wind load on Earth wire V 48.37 48.37
Wind load on Anchord OHE wlAohe= (wlf1+wlf2)*s/2 47.062 47.062
Wind load on Return conductor wlc=dr*wp*wlf*a*s 0.0 0.0
Wind load on mast wlm=wm*wp*hm*fm 171.822 171.822
Wind load on counter weight (kg) wcw V 50 50
Vertical Load
Weight of OHE (kg) wto=wt*s+wtm+wtb/2 205.200 205.200
Weight of Return conductor & fittings wtrf=wtr*s+wrf 0.000 0.000
Total vertical load wto 205.20 205.20
Bending moment Calculation
Length of lever arm anchor wire (m) ha 7.56 7.56
Length of lever arm-catenary wire (m) l1 C 7.81 7.81
Length of lever arm-contact wire (m) l2 C 6.41 6.41
Length of lever arm for Earth wire l3 C 7.30 7.30
Length of lever arm for Return conductor (m) (if not in
lr C 0.00 0.00
service =0)
Length of lever arm for Reurn conductor with its fitting (m) lm C 0.645 0.645
Implantation for mast Imp V 2.80 2.80
Radius of curvature greate than or equal to 3500m C 0.40 0.40
Radius of curvature greate than or equal to 2350m but less than 3500m C 0.55 0.55

Ca
Radius of curvature greate than or equal to 1150m but less than 2350m C 0.75 0.75

Radius of curvature greate than or equal to 300m but less than 1150m C 0.80 0.80

Track swelling (radius of curveture less 1400 will - value) Ts C 0.10 0.10
Stagger (for tangent-Stagger=0 & for cuveture-Stagger=.2) St C 0.00 0.00
Panto Intagalment (for X=0.06*5.8/1.67,
C 0.208 0.208
tangent X=.208, for curveture X=.66) X=0.19*5.8/1.67
Length of lever arm-vertical load (m) lv=Imp+Ca+wm/2+Ts-St V 3.726 3.726 change value in formula as per Ca
lAohe=Imp+Ca+wm/2-X-
Length of lever arm For Radial pull in anchored OHE (m) V 2.34 2.340 change value in formula as per Ca
4*v-St
Length of lever arm-Wind load on mast (m) lw C 4.075 4.075
Bending Moment due to wind load on Catenary wire wl1*l1 339.427 339.427
Bending Moment due to wind load on Contact wire wl2*l2 324.747 324.747
Bending Moment due to wind load on Earth wire 353.09 353.09
Bending Moment due to vertical load wto*lv -764.575 -764.575
Bending Moment due to wind load on mast wlm*lw 700.173 700.173
Bending Moment due to radial tension in contact wire rt*l2 71.222 71.222
Bending Moment due to radial pull on catenary wire rp1*l1 0.000 0.000
Bending Moment due to radial pull on contact wire rp2*l2 0.000 0.000
Bending Moment due to Radial pull on anchored OHE pull ((((t1+t2)*lv)/s)*ha) 491.281 491.362
Bending Moment due to RC wlr*lr 0.000 0.000
Bending Moment due to mast fitting with Return conductor wtrf*lm 0.000 0.000
Bending Moment due to wind load on anchored OHE wlAohe*ha 355.785 355.785
Bending Moment due to wind load on counter weights wcw*ha/2 189 189
Bending Moment due to anchor pully 65*ha 491 491
Total bending moment (kg-m) 2552 2552
Permissible Bending moment capacity of Masts (kg-m)
BFB 3370 3370
RSJ 5748 5748
B150, K150 4681 4681
B175, K175 6677 6677
B200, K200 8800 8800
B225, K225 11088 11088
B250, K250 13691 13691
MAST AVAILABLE AT SITE AT PRESENT BFB BFB
Permissible capacity of Masts AVAILABLE AT SITE 3370 3370
MAST AVAILABLE AT SITE PASSED OR TO BE REPLACED PASSED REPLACE PASSED PASSED
TYPE OF FOUNDATION AVAILABLE AT SITE AT PRESENT BG-01 BG-01
FBM CODE OF ABOVE TYPE OF FOUNDATION 115 115
Permissible Bending moment capacity of foundation AVAILABLE AT SITE 1500 1500

Commissioning SITE CONDITION (SIDE gravity TYPE, Side bearing type)


Side gravity Side gravity
Based on shoulder width at site

Present SITE CONDITION (SIDE gravity TYPE, Side bearing type) Based Side bearing Side bearing
on shoulder width at site type type

IF PRESENT SITE CONDITION IS DIFFERENT FROM COMMISSIONING


( i.e. possibility of SIDE gravity TYPE changing to Side bearing safer safer
type),then it wil make old foundation further safe)

FOUNDATION AVAILABLE AT SITE PASSED OR TO BE REPLACED REPLACE REPLACE


Note: 1. V=Variable, C=Constant
Note: 2. For foundation selection reffer drawings no.-
TI/DRG/CIV/FND/00001/13/0 (Sheet - 1 to 5)
Note:3. Difference between bending due to vetical and due to radial pull,
this will be added in bending moment due to wind force in mast,
catenary and contact wire.
72 67.5 63 58.5
72000 2200 1900 1600

800 1000 1100 1200


800 1000 1100 1200

0 1

73 105 136 155

0 0.0199
0 0.652

0.125 0.152 0.175 0.200

0 14

37.1 52.1 37.392 42.91

0 1
0 8.96 9.605
0.645 0.695 1.35

0.208 0.66
0.1 -0.1
0 0.2

0 0.01227
ue in formula as per Ca

ue in formula as per Ca
54 49.5 45 40.5 36
1400 1150 850 700 550 400

178 216

0.225 0.250

48.904 56.21 65.21


Checking of suitability of Overlap Central mast outside curve including tangent tarck for conventional OHE

Design data Symbol Remarks example value


span of OHE (m) s V 67.5 67.5
Radius of curvature of track (m) r V 72000 72000
versine v V 0.008 0.008
Panto Intagalment (for X=0.06*5.8/1.67,
0.208 0.208
tangent X=.208, for curveture X=-.66) X=0.19*5.8/1.67
Tension-catenary wire (kgf) t1 V 1000 1000
Tension-contact wire (kgf) t2 V 1000 1000
Diameter-Catenary wire (m) d1 V 0.01050 0.01050
Diameter-Contact wire (m) d2 V 0.01224 0.01224
Diameter of Earth wire (m) 0.01227 0.01227
Radial tension factor for contact wire (1 for
rtf V 1 1
tangent & 0 for curved track)
Radial tension in Contact wire rt 12 12
Wind Pressure (kg/sq.m), IS:875 (Part-III) 2015, Navy blue-
wp 150 150
73, Yellow-105, Blue-136, Green-155, Red-178
Unit weight of catenary wire(kg/m) wt1 0.7 0.7
Unit weight of contact wire (kg/m) wt2 C 0.9 0.9
Weight of man (kg) wtm C 60 60
Weight of cantiliver assembly (kg) wtb C 60 60
Diameter of Aluminium return conductor (m), (if
dr 0.0 0.0
not in service =0)
Unit Weight of Aluminium return conductor (kg/m) (if not
wtr V 0.0 0.0
in service =0)
projected area factor for conductors a C 0.75 0.75
Wind load factor for droperss wlf C 1.050 1.050
Mast width along the track (m), BFB/RSJ-
152, K/B125-125, K/B150-150, K/B175-175, K/B200-200, K/B225-225, K/B250- wm V 0.175 0.175
250
Height of mast above foundation level(m) hm C 8.15 8.15
Weight of return conductor fittings (kg) (if
wrf V 0.0 0.0
not in service =0)
Wind load factor on mast fm C 1.9 1.9
Weight of mast (kg/m) BFB-37.1, RSJ-52.1, K/B125-29.801, K/B150-37.392,
wtm V 37.1 37.1
K/B175-42.91, K/B200-48.904, K/B225-56.21, K/B250-65.21
Full length of mast (m) flm C 9.5 9.5
Radial pull Factor for tangent track-0, For curve track-1 V C 0.00 0.00
rp1=(8*v+2*.3-.4+.1+.2-
Radial pull in catenary Wire for long bracket (kg) (0 for tangent ) V 0.0 0.0
X+Imp)*t/s
rp1=(8*v+2*.3-.4+.1-.3-
Radial pull in contact Wire for long bracket (kg) (0 for tangent ) V 0.0 0.0
X+Imp)*t/s
rp3=V*(8*v+2*.8-.4-wm/
Radial pull in catenary Wire for short bracket (kg) 17.4 17.4
2)*t/s
rp4=V*(8*v+2*.8-.4-wm/
Radial pull in contact Wire for short bracket (kg) 17.4 17.4
2)*t/s
Design Calculation
Unit wind load on catenary wire-kg/m wlf1=d1*wp*a*wlf 1.240 1.240
Wind load on catenary wire wl1=wlf1*s 83.721 83.721
Unit wind load on contact wire-kg/m wlf2=d2*wp*a*wlf 1.446 1.446
Wind load on contact wire wl2=wlf2*s 97.595 97.595
Unite wind load on Earth wire V 1.38 1.38
Wind load on Earth wire V 93.18 93.18
Wind load on Return conductor wlc=dr*wp*wlf*a*s 0.0 0.0
Wind load on mast wlm=wm*wp*hm*fm 406.481 406.481
Vertical Load
Weight of Return conductor & fittings wtrf=wtr*s+wrf 0.000 0.000
Bending moment Calculation
Length of lever arm-catenary wire in long bracket (m) l1 C 7.81 7.81
Length of lever arm-contact wire in long bracket (m) l2 C 6.41 6.41
Length of lever arm-catenary wire in short bracket (m) l3 C 7.31 7.31
Length of lever arm-contact wire in short bracket (m) l4 C 6.91 6.91
Length of lever arm for Earth wire l3 C 7.30 7.30
Length of lever arm for Return conductor (m) (if
lr C 0.00 0.00
not in service =0)
Length of lever arm for Reurn conductor with its fitting (m) lm C 0.645 0.645
Standard implantation Imp C 2.80 2.80
Track swelling Ts C 0.1 0.1
Stagger for short bracket C 0.2 0.2
St
Stagger for long bracket C 0.7 0.7
Curve allowance (Radius of
Ca C 0.00 0.00
curveture less than 875m Ca=.15, otherwise 0)
Average Length of lever arm For vertical load catenary & contact wire for long lcatl/lcontl=imp+X+wm/
V 3.896 3.896
bracket (m) 2+Ts-Ca+St
Average Length of lever arm For vertical load catenary & contact wire for short lcats/lconts=imp+X+wm/
V 3.396 3.396
bracket (m) 2+Ts-Ca+St
Length of lever arm-Wind load on mast (m) lw C 4.075 4.075
Bending Moment due to wind load-Catenary wire for long bracket wl1*l1 653.862 653.862
Bending Moment due to wind load-Contact wire for long bracket wl2*l2 625.583 625.583
Bending Moment due to wind load-Catenary wire for short bracket wl1*l3 612.001 612.001
Bending Moment due to wind load-Contact wire for short bracket wl2*l4 674.381 674.381
Bending Moment due to wind load on Earth wire 680.18 680.18
Bending Moment due to wind load on mast wlm*lw 1656.41 1656.41
Bending Moment due to wind load on cross arm 1.1*wp*.15*(l1+l2)/2 272.621 272.621
Bending Moment due to radial tension in contact wire rt*l2 75.970 75.970
Bending Moment due to radial pull on catenary wire long bracket rp1*l1 0.000 0.000
Bending Moment due to radial pull on contact wire long bracket rp2*l2 0.000 0.000
Bending Moment due to radial pull on catenary wire short bracket rp3*l3 -127.333 -127.333
Bending Moment due to radial pull on contact wire short bracket rp4*l4 -120.365 -120.365
Bending Moment due to RC wlr*lr 0.000 0.000
Bending Moment due to mast fitting with Return conductor wtrf*lm 0.000 0.000
lcatl*((wt1+w2)*s+wtm/
Bending Moment due to vertical load catenary & contact wire for long bracket -498.965 -498.965
2+20)
lcats*((wt1+w2)*s+wtm/
Bending Moment due to vertical load catenary & contact wire for short bracket 367.011 367.011
2)
Total bending moment (kg-m) 4871 4871
Permissible Bending moment capacity of Masts (kg-m)
BFB 4011 4011
RSJ 6674 6674
B150, K150 5053 5053
B175, K175 7032 7032
B200, K200 9140 9140
B225, K225 11413 11413
B250, K250 14008 14008
MAST AVAILABLE AT SITE AT PRESENT BFB BFB
Permissible capacity of Masts AVAILABLE AT SITE 4011 4011
MAST AVAILABLE AT SITE PASSED OR TO BE REPLACED PASSED REPLACE REPLACE REPLACE
TYPE OF FOUNDATION AVAILABLE AT SITE AT PRESENT BG-01 BG-01
FBM CODE OF ABOVE TYPE OF FOUNDATION 115 115
Permissible Bending moment capacity of foundation AVAILABLE AT SITE 1500 1500

Commissioning SITE CONDITION (SIDE gravity TYPE, Side bearing type) Based on Side
Side gravity
shoulder width at site gravity
Side Side
Present SITE CONDITION (SIDE gravity TYPE, Side bearing type) Based on
bearing bearing
shoulder width at site
type type
IF PRESENT SITE CONDITION IS DIFFERENT FROM COMMISSIONING ( i.e.
possibility of SIDE gravity TYPE changing to Side bearing type),then it wil make safer safer
old foundation further safe)
FOUNDATION AVAILABLE AT SITE PASSED OR TO BE REPLACED REPLACE REPLACE
Note: 1. V=Variable, C=Constant
Note: 2. For foundation selection reffer drawings no.-
TI/DRG/CIV/FND/00001/13/0 (Sheet - 1 to 5)
Note:3. Difference between bending due to vetical and due to radial pull, this will
be added in bending moment due to wind force in mast, catenary and contact
wire.

72 67.5
72000 2200

800 1000
800 1000

0 1

73 105

0 0.0199
0 0.652

0.125 0.152

0 14

37.1 52.1

0 1
0 8.96
0.645 0.695

0.208 -0.66

0 0.15

0 0.01227
63 58.5 54 49.5 45 40.5 36
1900 1600 1400 1150 850 700 550 400

1100 1200
1100 1200

136 155 178 216

0.175 0.200 0.225 0.250

37.392 42.91 48.904 56.21 65.21


9.605
1.35
Checking of suitability of Overlap Central mast inside curve including tangent tarck for conventional OHE

Design data Symbol Remarks Example


span of OHE (m) s V 63.0 63.0
Radius of curvature of track (m) r V 2500 2500
versine v V 0.198 0.198
Panto Intagalment (for X=0.06*5.8/1.67,
0.660 0.660
tangent X=.208, for curveture X=.66) X=0.19*5.8/1.67
Tension-catenary wire (kgf) t1 V 1000 1000
Tension-contact wire (kgf) t2 V 1000 1000
Diameter-Catenary wire (m) d1 V 0.01050 0.01050
Diameter-Contact wire (m) d2 V 0.01224 0.01224
Diameter of Earth wire (m) V 0.01227 0.01227
Radial tension factor for contact wire (1 for
rtf V 0 0
tangent & 0 for curved track)
Radial tension in Contact wire rt 0 0
Wind Pressure (kg/sq.m), IS:875 (Part-III) 2015, Navy blue-
wp 150 150
73, Yellow-105, Blue-136, Green-155, Red-178
Unit weight of catenary wire(kg/m) wt1 0.7 0.7
Unit weight of contact wire (kg/m) wt2 C 0.9 0.9
Weight of man (kg) wtm C 60 60
Weight of cantiliver assembly (kg) wtb C 60 60
Diameter of Aluminium return conductor (m), (if
dr 0.0 0.0
not in service =0)
Unit Weight of Aluminium return conductor (kg/m) (if not
wtr V 0.0 0.0
in service =0)
projected area factor for conductors a C 0.75 0.75
Wind load factor for droperss wlf C 1.050 1.050
Mast width along the track (m), BFB/RSJ-
152, K/B125-125, K/B150-150, K/B175-175, K/B200-200, K/B225-225, K/B250- wm V 0.152 0.152
250
Height of mast above foundation level(m) hm C 8.15 8.15
Weight of return conductor fittings (kg) (if
wrf V 0.0 0.0
not in service =0)
Wind load factor on mast fm C 1.9 1.9
Weight of mast (kg/m) BFB-37.1, RSJ-52.1, K/B125-29.801, K/B150-37.392,
wtm V 37.1 37.1
K/B175-42.91, K/B200-48.904, K/B225-56.21, K/B250-65.21
Full length of mast (m) flm C 9.5 9.5

rp1=(8*v-.2+2*St+Ts+w
Radial pull in catenary Wire for long bracket (kg) V 89.7 89.7
m/2-X+Imp+Ca)*t/s
rp2=(8*v-.2+2*St+Ts+w
Radial pull in contact Wire for long bracket (kg) V 89.7 89.7
m/2-X+Imp+Ca)*t/s

Radial pull in catenary Wire for short bracket (kg) rp3=8*v+2*St+.3-X V 25.8 25.8
Radial pull in contact Wire for short bracket (kg) rp4=8*v+2*St+.3-X V 25.8 25.8
Design Calculation
Unit wind load on catenary wire-kg/m wlf1=d1*wp*a*wlf 1.240 1.240
Wind load on catenary wire wl1=wlf1*s 78.140 78.140
Unit wind load on contact wire-kg/m wlf2=d2*wp*a*wlf 1.446 1.446
Wind load on contact wire wl2=wlf2*s 91.089 91.089
Unite wind load on Earth wire V 1.38 1.38
Wind load on Earth wire V 86.96 86.96
Wind load on Return conductor wlc=dr*wp*wlf*a*s 0.0 0.0
Wind load on mast wlm=wm*wp*hm*fm 353.058 353.058
Vertical Load
Weight of Return conductor & fittings wtrf=wtr*s+wrf 0.000 0.000
Bending moment Calculation
Length of lever arm-catenary wire in long bracket (m) l1 C 7.81 7.81
Length of lever arm-contact wire in long bracket (m) l2 C 6.41 6.41
Length of lever arm-catenary wire in short bracket (m) l3 C 7.31 7.31
Length of lever arm-contact wire in short bracket (m) l4 C 6.91 6.91
Length of lever arm for Earth wire l3 C 7.30 7.30
Length of lever arm for Return conductor (m) (if
lr C 0.00 0.00
not in service =0)
Length of lever arm for Reurn conductor with its fitting (m) lm C 0.645 0.645
Standard implantation Imp C 2.80 2.80
Radius of curvature greate than or equal to 3500m C 0.40 0.40
Radius of curvature greate than or equal to 2350m but less than 3500m C 0.55 0.55
Ca
Radius of curvature greate than or equal to 1150m but less than 2350m C 0.75 0.75
Radius of curvature greate than or equal to 300m but less than 1150m C 0.80 0.80
Track swelling Ts C 0.10 0.10
Stagger for short bracket C 0.2 0.2
St
Stagger for long bracket C 0.7 0.7
Average Length of lever arm For vertical load catenary & contact wire for long lcatl/lcontl=imp+Ca-
V 3.566 3.566
bracket (m) X+wm/2-Ts+St
Average Length of lever arm For vertical load catenary & contact wire for short lcats/lconts=imp-
2.316 2.316
bracket (m) X+wm/2-Ts+Ca+St
Length of lever arm-Wind load on mast (m) lw C 4.075 4.075
Bending Moment due to wind load-Catenary wire for long bracket wl1*l1 610.271 610.271
Bending Moment due to wind load-Contact wire for long bracket wl2*l2 583.878 583.878
Bending Moment due to wind load-Catenary wire for short bracket wl1*l3 571.201 571.201
Bending Moment due to wind load-Contact wire for short bracket wl2*l4 629.422 629.422
Bending Moment due to wind load on Earth wire 634.83 634.83
Bending Moment due to wind load on mast wlm*lw 1438.711 1438.711
Bending Moment due to wind load on cross arm 1.1*wp*.15*(l1+l2)/2 272.621 272.621
Bending Moment due to radial tension in contact wire rt*l2 0.000 0.000
Bending Moment due to radial pull on catenary wire long bracket rp1*l1 700.882 700.882
Bending Moment due to radial pull on contact wire long bracket rp2*l2 575.244 575.244
Bending Moment due to radial pull on catenary wire short bracket rp3*l3 188.867 188.867
Bending Moment due to radial pull on contact wire short bracket rp4*l4 178.532 178.532
Bending Moment due to RC wlr*lr 0.000 0.000
Bending Moment due to mast fitting with Return conductor wtrf*lm 0.000 0.000
lcatl*((wt1+wt2)*s+wtm/
Bending Moment due to vertical load catenary & contact wire for long bracket -431.058 -431.058
2+20)
lcats*((wt1+wt2)*s+wtm
Bending Moment due to vertical load catenary & contact wire for short bracket -233.641 -233.641
/2)
Total bending moment (kg-m) 5720 5720
Permissible Bending moment capacity of Masts (kg-m)
BFB 4011 4011
RSJ 6674 6674
B150, K150 5053 5053
B175, K175 7032 7032
B200, K200 9140 9140
B225, K225 11413 11413
B250, K250 14008 14008
MAST AVAILABLE AT SITE AT PRESENT BFB BFB
Permissible capacity of Masts AVAILABLE AT SITE 4011 4011
MAST AVAILABLE AT SITE PASSED OR TO BE REPLACED PASSED REPLACE REPLACE REPLACE
TYPE OF FOUNDATION AVAILABLE AT SITE AT PRESENT BG-01 BG-01
FBM CODE OF ABOVE TYPE OF FOUNDATION 115 115
Permissible Bending moment capacity of foundation AVAILABLE AT SITE 1500 1500

Commissioning SITE CONDITION (SIDE gravity TYPE, Side bearing type) Based on Side
Side gravity
shoulder width at site gravity
Side
Present SITE CONDITION (SIDE gravity TYPE, Side bearing type) Based on Side bearing
bearing
shoulder width at site type
type
IF PRESENT SITE CONDITION IS DIFFERENT FROM COMMISSIONING ( i.e.
possibility of SIDE gravity TYPE changing to Side bearing type),then it wil make safer safer
old foundation further safe)
FOUNDATION AVAILABLE AT SITE PASSED OR TO BE REPLACED REPLACE REPLACE

Note: 1. V=Variable, C=Constant


Note: 2. For foundation selection reffer drawings no.-
TI/DRG/CIV/FND/00001/13/0 (Sheet - 1 to 5)
Note:3. Difference between bending due to vetical and due to radial pull, this will
be added in bending moment due to wind force in mast, catenary and contact
wire.

72 67.5 63
72000 2500 2200 1900

800 1000 1100


800 1000 1100

0 1

73 105 136

0 0.0199
0 0.652

0.125 0.152 0.175

0 14

37.1 52.1 37.392

0 0.01227

0 0.318

0 7.3
0 8.96 9.605
0.645 0.695 1.35

0 0.01227
58.5 54 49.5 45 40.5 36
1600 1400 1150 850 700 550 400

1200
1200

155 178 216

0.200 0.225 0.250

42.91 48.904 56.21 65.21


Checking of suitability of Overlap Central mast outside curve including tangent tarck for conventional OHE

Design data Symbol Remarks example value


span of OHE (m) s V 67.5 67.5
Radius of curvature of track (m) r V 72000 72000
versine v V 0.008 0.008
Panto Intagalment (for X=0.06*5.8/1.67,
0.208 0.208
tangent X=.208, for curveture X=-.66) X=0.19*5.8/1.67
Tension-catenary wire (kgf) t1 V 1000 1000
Tension-contact wire (kgf) t2 V 1000 1000
Diameter-Catenary wire (m) d1 V 0.01050 0.01050
Diameter-Contact wire (m) d2 V 0.01224 0.01224
Diameter of Earth wire (m) 0.01227 0.01227
Radial tension factor for contact wire (1 for
rtf V 1 1
tangent & 0 for curved track)
Radial tension in Contact wire rt 12 12
Wind Pressure (kg/sq.m), IS:875 (Part-III) 2015, Navy blue-
wp 150 150
73, Yellow-105, Blue-136, Green-155, Red-178
Unit weight of catenary wire(kg/m) wt1 0.7 0.7
Unit weight of contact wire (kg/m) wt2 C 0.9 0.9
Weight of man (kg) wtm C 60 60
Weight of cantiliver assembly (kg) wtb C 60 60
Diameter of Aluminium return conductor (m), (if
dr 0.0 0.0
not in service =0)
Unit Weight of Aluminium return conductor (kg/m) (if not
wtr V 0.0 0.0
in service =0)
projected area factor for conductors a C 0.75 0.75
Wind load factor for droperss wlf C 1.050 1.050
Mast width along the track (m), BFB/RSJ-
152, K/B125-125, K/B150-150, K/B175-175, K/B200-200, K/B225-225, K/B250- wm V 0.175 0.175
250
Height of mast above foundation level(m) hm C 8.15 8.15
Weight of return conductor fittings (kg) (if
wrf V 0.0 0.0
not in service =0)
Wind load factor on mast fm C 1.9 1.9
Weight of mast (kg/m) BFB-37.1, RSJ-52.1, K/B125-29.801, K/B150-37.392,
wtm V 37.1 37.1
K/B175-42.91, K/B200-48.904, K/B225-56.21, K/B250-65.21
Full length of mast (m) flm C 9.5 9.5
Radial pull Factor for tangent track-0, For curve track-1 V C 0.00 0.00
rp1=(8*v+2*.3-.4+.1+.2-
Radial pull in catenary Wire for long bracket (kg) (0 for tangent ) V 0.0 0.0
X+Imp)*t/s
rp1=(8*v+2*.3-.4+.1-.3-
Radial pull in contact Wire for long bracket (kg) (0 for tangent ) V 0.0 0.0
X+Imp)*t/s
rp3=V*(8*v+2*.8-.4-wm/
Radial pull in catenary Wire for short bracket (kg) 17.4 17.4
2)*t/s
rp4=V*(8*v+2*.8-.4-wm/
Radial pull in contact Wire for short bracket (kg) 17.4 17.4
2)*t/s
Design Calculation
Unit wind load on catenary wire-kg/m wlf1=d1*wp*a*wlf 1.240 1.240
Wind load on catenary wire wl1=wlf1*s 83.721 83.721
Unit wind load on contact wire-kg/m wlf2=d2*wp*a*wlf 1.446 1.446
Wind load on contact wire wl2=wlf2*s 97.595 97.595
Unite wind load on Earth wire V 1.38 1.38
Wind load on Earth wire V 93.18 93.18
Wind load on Return conductor wlc=dr*wp*wlf*a*s 0.0 0.0
Wind load on mast wlm=wm*wp*hm*fm 406.481 406.481
Vertical Load
Weight of Return conductor & fittings wtrf=wtr*s+wrf 0.000 0.000
Bending moment Calculation
Length of lever arm-catenary wire in long bracket (m) l1 C 7.81 7.81
Length of lever arm-contact wire in long bracket (m) l2 C 6.41 6.41
Length of lever arm-catenary wire in short bracket (m) l3 C 7.31 7.31
Length of lever arm-contact wire in short bracket (m) l4 C 6.91 6.91
Length of lever arm for Earth wire l3 C 7.30 7.30
Length of lever arm for Return conductor (m) (if
lr C 0.00 0.00
not in service =0)
Length of lever arm for Reurn conductor with its fitting (m) lm C 0.645 0.645
Standard implantation Imp C 2.80 2.80
Track swelling Ts C 0.1 0.1
Stagger for short bracket C 0.2 0.2
St
Stagger for long bracket C 0.7 0.7
Curve allowance (Radius of
Ca C 0.00 0.00
curveture less than 875m Ca=.15, otherwise 0)
Average Length of lever arm For vertical load catenary & contact wire for long lcatl/lcontl=imp+X+wm/
V 3.896 3.896
bracket (m) 2+Ts-Ca+St
Average Length of lever arm For vertical load catenary & contact wire for short lcats/lconts=imp+X+wm/
V 3.396 3.396
bracket (m) 2+Ts-Ca+St
Length of lever arm-Wind load on mast (m) lw C 4.075 4.075
Bending Moment due to wind load-Catenary wire for long bracket wl1*l1 653.862 653.862
Bending Moment due to wind load-Contact wire for long bracket wl2*l2 625.583 625.583
Bending Moment due to wind load-Catenary wire for short bracket wl1*l3 612.001 612.001
Bending Moment due to wind load-Contact wire for short bracket wl2*l4 674.381 674.381
Bending Moment due to wind load on Earth wire 680.18 680.18
Bending Moment due to wind load on mast wlm*lw 1656.41 1656.41
Bending Moment due to wind load on cross arm 1.1*wp*.15*(l1+l2)/2 272.621 272.621
Bending Moment due to radial tension in contact wire rt*l2 75.970 75.970
Bending Moment due to radial pull on catenary wire long bracket rp1*l1 0.000 0.000
Bending Moment due to radial pull on contact wire long bracket rp2*l2 0.000 0.000
Bending Moment due to radial pull on catenary wire short bracket rp3*l3 -127.333 -127.333
Bending Moment due to radial pull on contact wire short bracket rp4*l4 -120.365 -120.365
Bending Moment due to RC wlr*lr 0.000 0.000
Bending Moment due to mast fitting with Return conductor wtrf*lm 0.000 0.000
lcatl*((wt1+w2)*s+wtm/
Bending Moment due to vertical load catenary & contact wire for long bracket -498.965 -498.965
2+20)
lcats*((wt1+w2)*s+wtm/
Bending Moment due to vertical load catenary & contact wire for short bracket 367.011 367.011
2)
Total bending moment (kg-m) 4871 4871
Permissible Bending moment capacity of Masts (kg-m)
BFB 4011 4011
RSJ 6674 6674
B150, K150 5053 5053
B175, K175 7032 7032
B200, K200 9140 9140
B225, K225 11413 11413
B250, K250 14008 14008
MAST AVAILABLE AT SITE AT PRESENT BFB BFB
Permissible capacity of Masts AVAILABLE AT SITE 4011 4011
MAST AVAILABLE AT SITE PASSED OR TO BE REPLACED PASSED REPLACE REPLACE REPLACE
TYPE OF FOUNDATION AVAILABLE AT SITE AT PRESENT BG-01 BG-01
FBM CODE OF ABOVE TYPE OF FOUNDATION 115 115
Permissible Bending moment capacity of foundation AVAILABLE AT SITE 1500 1500

Commissioning SITE CONDITION (SIDE gravity TYPE, Side bearing type) Based on Side
Side gravity
shoulder width at site gravity
Side Side
Present SITE CONDITION (SIDE gravity TYPE, Side bearing type) Based on
bearing bearing
shoulder width at site
type type
IF PRESENT SITE CONDITION IS DIFFERENT FROM COMMISSIONING ( i.e.
possibility of SIDE gravity TYPE changing to Side bearing type),then it wil make safer safer
old foundation further safe)
FOUNDATION AVAILABLE AT SITE PASSED OR TO BE REPLACED REPLACE REPLACE
Note: 1. V=Variable, C=Constant
Note: 2. For foundation selection reffer drawings no.-
TI/DRG/CIV/FND/00001/13/0 (Sheet - 1 to 5)
Note:3. Difference between bending due to vetical and due to radial pull, this will
be added in bending moment due to wind force in mast, catenary and contact
wire.

72 67.5
72000 2200

800 1000
800 1000

0 1

73 105

0 0.0199
0 0.652

0.125 0.152

0 14

37.1 52.1

0 1
0 8.96
0.645 0.695

0.208 -0.66

0 0.15

0 0.01227
63 58.5 54 49.5 45 40.5 36
1900 1600 1400 1150 850 700 550 400

1100 1200
1100 1200

136 155 178 216

0.175 0.200 0.225 0.250

37.392 42.91 48.904 56.21 65.21


9.605
1.35
Checking of suitability of Overlap Central mast inside curve including tangent tarck for conventional OHE

Design data Symbol Remarks Example


span of OHE (m) s V 63.0 63.0
Radius of curvature of track (m) r V 2500 2500
versine v V 0.198 0.198
Panto Intagalment (for X=0.06*5.8/1.67,
0.660 0.660
tangent X=.208, for curveture X=.66) X=0.19*5.8/1.67
Tension-catenary wire (kgf) t1 V 1000 1000
Tension-contact wire (kgf) t2 V 1000 1000
Diameter-Catenary wire (m) d1 V 0.01050 0.01050
Diameter-Contact wire (m) d2 V 0.01224 0.01224
Diameter of Earth wire (m) V 0.01227 0.01227
Radial tension factor for contact wire (1 for
rtf V 0 0
tangent & 0 for curved track)
Radial tension in Contact wire rt 0 0
Wind Pressure (kg/sq.m), IS:875 (Part-III) 2015, Navy blue-
wp 150 150
73, Yellow-105, Blue-136, Green-155, Red-178
Unit weight of catenary wire(kg/m) wt1 0.7 0.7
Unit weight of contact wire (kg/m) wt2 C 0.9 0.9
Weight of man (kg) wtm C 60 60
Weight of cantiliver assembly (kg) wtb C 60 60
Diameter of Aluminium return conductor (m), (if
dr 0.0 0.0
not in service =0)
Unit Weight of Aluminium return conductor (kg/m) (if not
wtr V 0.0 0.0
in service =0)
projected area factor for conductors a C 0.75 0.75
Wind load factor for droperss wlf C 1.050 1.050
Mast width along the track (m), BFB/RSJ-
152, K/B125-125, K/B150-150, K/B175-175, K/B200-200, K/B225-225, K/B250- wm V 0.152 0.152
250
Height of mast above foundation level(m) hm C 8.15 8.15
Weight of return conductor fittings (kg) (if
wrf V 0.0 0.0
not in service =0)
Wind load factor on mast fm C 1.9 1.9
Weight of mast (kg/m) BFB-37.1, RSJ-52.1, K/B125-29.801, K/B150-37.392,
wtm V 37.1 37.1
K/B175-42.91, K/B200-48.904, K/B225-56.21, K/B250-65.21
Full length of mast (m) flm C 9.5 9.5

rp1=(8*v-.2+2*St+Ts+w
Radial pull in catenary Wire for long bracket (kg) V 89.7 89.7
m/2-X+Imp+Ca)*t/s
rp2=(8*v-.2+2*St+Ts+w
Radial pull in contact Wire for long bracket (kg) V 89.7 89.7
m/2-X+Imp+Ca)*t/s

Radial pull in catenary Wire for short bracket (kg) rp3=8*v+2*St+.3-X V 25.8 25.8
Radial pull in contact Wire for short bracket (kg) rp4=8*v+2*St+.3-X V 25.8 25.8
Design Calculation
Unit wind load on catenary wire-kg/m wlf1=d1*wp*a*wlf 1.240 1.240
Wind load on catenary wire wl1=wlf1*s 78.140 78.140
Unit wind load on contact wire-kg/m wlf2=d2*wp*a*wlf 1.446 1.446
Wind load on contact wire wl2=wlf2*s 91.089 91.089
Unite wind load on Earth wire V 1.38 1.38
Wind load on Earth wire V 86.96 86.96
Wind load on Return conductor wlc=dr*wp*wlf*a*s 0.0 0.0
Wind load on mast wlm=wm*wp*hm*fm 353.058 353.058
Vertical Load
Weight of Return conductor & fittings wtrf=wtr*s+wrf 0.000 0.000
Bending moment Calculation
Length of lever arm-catenary wire in long bracket (m) l1 C 7.81 7.81
Length of lever arm-contact wire in long bracket (m) l2 C 6.41 6.41
Length of lever arm-catenary wire in short bracket (m) l3 C 7.31 7.31
Length of lever arm-contact wire in short bracket (m) l4 C 6.91 6.91
Length of lever arm for Earth wire l3 C 7.30 7.30
Length of lever arm for Return conductor (m) (if
lr C 0.00 0.00
not in service =0)
Length of lever arm for Reurn conductor with its fitting (m) lm C 0.645 0.645
Standard implantation Imp C 2.80 2.80
Radius of curvature greate than or equal to 3500m C 0.40 0.40
Radius of curvature greate than or equal to 2350m but less than 3500m C 0.55 0.55
Ca
Radius of curvature greate than or equal to 1150m but less than 2350m C 0.75 0.75
Radius of curvature greate than or equal to 300m but less than 1150m C 0.80 0.80
Track swelling Ts C 0.10 0.10
Stagger for short bracket C 0.2 0.2
St
Stagger for long bracket C 0.7 0.7
Average Length of lever arm For vertical load catenary & contact wire for long lcatl/lcontl=imp+Ca-
V 3.566 3.566
bracket (m) X+wm/2-Ts+St
Average Length of lever arm For vertical load catenary & contact wire for short lcats/lconts=imp-
2.316 2.316
bracket (m) X+wm/2-Ts+Ca+St
Length of lever arm-Wind load on mast (m) lw C 4.075 4.075
Bending Moment due to wind load-Catenary wire for long bracket wl1*l1 610.271 610.271
Bending Moment due to wind load-Contact wire for long bracket wl2*l2 583.878 583.878
Bending Moment due to wind load-Catenary wire for short bracket wl1*l3 571.201 571.201
Bending Moment due to wind load-Contact wire for short bracket wl2*l4 629.422 629.422
Bending Moment due to wind load on Earth wire 634.83 634.83
Bending Moment due to wind load on mast wlm*lw 1438.711 1438.711
Bending Moment due to wind load on cross arm 1.1*wp*.15*(l1+l2)/2 272.621 272.621
Bending Moment due to radial tension in contact wire rt*l2 0.000 0.000
Bending Moment due to radial pull on catenary wire long bracket rp1*l1 700.882 700.882
Bending Moment due to radial pull on contact wire long bracket rp2*l2 575.244 575.244
Bending Moment due to radial pull on catenary wire short bracket rp3*l3 188.867 188.867
Bending Moment due to radial pull on contact wire short bracket rp4*l4 178.532 178.532
Bending Moment due to RC wlr*lr 0.000 0.000
Bending Moment due to mast fitting with Return conductor wtrf*lm 0.000 0.000
lcatl*((wt1+wt2)*s+wtm/
Bending Moment due to vertical load catenary & contact wire for long bracket -431.058 -431.058
2+20)
lcats*((wt1+wt2)*s+wtm
Bending Moment due to vertical load catenary & contact wire for short bracket -233.641 -233.641
/2)
Total bending moment (kg-m) 5720 5720
Permissible Bending moment capacity of Masts (kg-m)
BFB 4011 4011
RSJ 6674 6674
B150, K150 5053 5053
B175, K175 7032 7032
B200, K200 9140 9140
B225, K225 11413 11413
B250, K250 14008 14008
MAST AVAILABLE AT SITE AT PRESENT BFB BFB
Permissible capacity of Masts AVAILABLE AT SITE 4011 4011
MAST AVAILABLE AT SITE PASSED OR TO BE REPLACED PASSED REPLACE REPLACE REPLACE
TYPE OF FOUNDATION AVAILABLE AT SITE AT PRESENT BG-01 BG-01
FBM CODE OF ABOVE TYPE OF FOUNDATION 115 115
Permissible Bending moment capacity of foundation AVAILABLE AT SITE 1500 1500

Commissioning SITE CONDITION (SIDE gravity TYPE, Side bearing type) Based on Side
Side gravity
shoulder width at site gravity
Side
Present SITE CONDITION (SIDE gravity TYPE, Side bearing type) Based on Side bearing
bearing
shoulder width at site type
type
IF PRESENT SITE CONDITION IS DIFFERENT FROM COMMISSIONING ( i.e.
possibility of SIDE gravity TYPE changing to Side bearing type),then it wil make safer safer
old foundation further safe)
FOUNDATION AVAILABLE AT SITE PASSED OR TO BE REPLACED REPLACE REPLACE

Note: 1. V=Variable, C=Constant


Note: 2. For foundation selection reffer drawings no.-
TI/DRG/CIV/FND/00001/13/0 (Sheet - 1 to 5)
Note:3. Difference between bending due to vetical and due to radial pull, this will
be added in bending moment due to wind force in mast, catenary and contact
wire.

72 67.5 63
72000 2500 2200 1900

800 1000 1100


800 1000 1100

0 1

73 105 136

0 0.0199
0 0.652

0.125 0.152 0.175

0 14

37.1 52.1 37.392

0 0.01227

0 0.318

0 7.3
0 8.96 9.605
0.645 0.695 1.35

0 0.01227
58.5 54 49.5 45 40.5 36
1600 1400 1150 850 700 550 400

1200
1200

155 178 216

0.200 0.225 0.250

42.91 48.904 56.21 65.21

You might also like