You are on page 1of 3

File: 258-fc3545 Page 1 of 3

Fault Code 3545

Aftertreatment 1 Outlet NOx Sensor - Abnormal Rate of Change

CODES REASON EFFECT

Fault Code: 3545 The aftertreatment outlet NOx None on performance.


PID(P), SID(S): sensor reading is not valid.
SPN: 3226
FMI: 10/10
Lamp: Amber
SRT:

Aftertreatment Outlet NOx Sensor Circuit

Circuit Description:
The aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control
module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and
reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to
the NOx control module. They are serviced as a single component and can not be replaced individually. The
aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component Location:
The aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the
exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

© 2008 Cummins Inc., Box 3005, Columbus, IN 47202-3005 U.S.A. Printed from QuickServe® Online.
All Rights Reserved. Last Modified: 05-Apr-2020
File: 258-fc3545 Page 2 of 3
Conditions for Running the Diagnostics:
This diagnostic runs when the aftertreatment SCR outlet temperature has been above 200°C [392° F] for a calibratible
period of time while the engine is running.

Conditions for Setting the Fault Codes:


The aftertreatment outlet NOx sensor reading was not valid.

Action Taken When the Fault Code is Active:


• The ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.

Conditions for Clearing the Fault Code:


• To validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either
driving the vehicle or initiating a stationary regeneration using the recommended Cummins® electronic service tool
or equivalent.
• The aftertreatment SCR outlet temperature must be above 200° C [392° F] for 60 seconds before the
aftertreatment outlet NOx sensor can run its internal diagnostics.
• The fault code status displayed by the recommended Cummins® electronic service tool or equivalent will change to
INACTIVE immediately after the diagnostic runs and passes.
• The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
• The “Reset All Faults” command in the recommended Cummins® electronic service tool or equivalent can be used
to clear active and inactive faults.

Shop Talk:
This fault code sets when the aftertreatment outlet NOx sensor indicates to the ECM that it is not providing valid data.
Troubleshoot the aftertreatment outlet NOx sensor for Fault Codes 1887, 2771, or 3682 before troubleshooting this
fault code.
• Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the
OEM.
For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly
recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or
intermittent connections.

Refer to Troubleshooting Fault Code 3545 .

© 2008 Cummins Inc., Box 3005, Columbus, IN 47202-3005 U.S.A. Printed from QuickServe® Online.
All Rights Reserved. Last Modified: 05-Apr-2020
File: 258-fc3545 Page 3 of 3

© 2008 Cummins Inc., Box 3005, Columbus, IN 47202-3005 U.S.A. Printed from QuickServe® Online.
All Rights Reserved. Last Modified: 05-Apr-2020

You might also like