You are on page 1of 72

BUYER’S

GUIDE

AC INDUCTION MOTORS
200 ~ 2,000 HP
UP TO 6,600 VOLT
50, 60 Hz
Scope of This Book

This buyer’s guide is to provide customers with a reference manual for easy searching, selection and
procurement when requiring electric motors. The scope of this book is confined in large size AC
horizontal and vertical induction motors. The standard specifications are as follows.
Standard Specifications
Type Three Phase Squirrel Cage Induction Motor

Voltage 380V ~ 6,600V

Frequency 60 Hz, 50 Hz

Enclosure Totally Enclosed Fan Cooled (TEFC) / Totally Enclosed Air-to-Air Cooled (TEAAC)

Protection degree IP 54

Cooling method IC 411 / IC 611

Mounting Horizontal foot mounting (IMB3) / Vertical flange mounting (IMV1)

Insulation Class F

Temperature rise Class B (80℃ by resistance method at S.F. 1.0)

Service factor 1.15

Duty Continuous duty (S1)

Ambient air temperature -20℃ ~ 40℃

Environmental Humidity Below 95% RH


conditions Altitude Below 1,000 meter

Location Indoors / outdoors, non-hazardous area

Starting method Full voltage starting (Low voltage motors may be started in Y-∆ connection)

Coupling method Directly coupled

Bearing Horizontal 2 pole: anti-friction or sleeve bearing / Others: anti-friction bearing


Horizontal 2 pole with anti-friction bearing: oil or grease
Horizontal 2 pole with sleeve bearing: oil
Lubricant
Horizontal 4 pole & above with anti-friction bearing: grease
Vertical motors: grease / oil
Noise Sound Pressure Level (SPL) 85 dBA at 1 meter distance (No load)

Finish paint color Wooden gray (Munsell code 7.5Y 8.9/0.4)

Accessories Shaft end key, external grounding terminal, space heater for steel frame motor
Applicable
IEC, JIS, JEC, CNS
standards

1
CONTENTS

Scope of This Book 1

1 General Introduction 4
1.1 about Tatung 4
1.1.1 Tatung company 4
1.1.2 Tatung electric motors 6
1.2 Technical Information 8
1.2.1 Output 8
1.2.2 Voltage 9
1.2.3 Duty 10
1.2.4 Torque 11
1.2.5 Insulation 12
1.2.6 Starting methods 13
1.2.7 Efficiency 14
1.2.8 Power factor 14
1.2.9 Enclosure 14
1.2.10 Mounting arrangement 19
1.2.11 Environmental conditions 20
1.2.12 Bearings 21
1.2.13 Coupling methods 26
1.2.14 Vibration 27
1.2.15 Noise 29
1.3 Specifying and Ordering Motors 30

2 Outline Dimensions 33
2.1 Horizontal TEFC / TEAAC Motors 34
2.2 Vertical TEFC / TEAAC Motors 40

2
3 Performance Data 43
3.1 Horizontal TEFC / TEAAC Motors 44
3.2 Vertical TEFC / TEAAC Motors 58

3
1. General Information

1.1 about Tatung

1.1.1 Tatung company

Late Mr. Shan-Chih Lin, founder and first chairman of Tatung Company, set up Hsieh-Chih Company
in 1918. He established credit and reputation by completing more than 600 constructions, including the
Building of the Executive Yuan, in the span of 30 years. In 1939, Tatung Iron Works was established as the
first private steel and machinery manufacturer in Taiwan.

Aware that able people are the most important asset of a business and that education of industrial
talent can facilitate progress of industrialization, Mr. Shan-Chih Lin wound his own business up in 1942
and donated his own property to establish Tatung Schools-Company. The founder donated 10 percent of
his property to all the Tatung colleagues so that they were able to become employee-shareholders. Other
80 percent was donated to the Hsieh-Chih Association for the Development of Industry, which
appropriated funds for the formation of Hsieh-Chih Industrial Awards, Hsieh-Chih Industrial Scholarship,
Tatung University and Hsieh-Chih Publishing Company, as well as for the inauguration of Tatung
Schools-Company, a unique education-industry integrated program in the world. Dr. T. S. Lin was then
appointed by the founder to take up a position with three functions - professor, president and chairman of
Tatung Schools-Company. Since then, Dr. Lin has dedicated himself to the unique sublime management
principles--“Education-Industry Integration for Research and Development”, “Labor-Management
Cooperation for Industrial Autonomy”, “Social Investment for Publicly-owned Company”, and “Creating
Profits to Share with Customers.”

Tatung commenced to produce electric motors and electric fans in 1949. Being a forerunner, Tatung
laid the foundation of electric motor manufacturing in Taiwan. Under Dr. Lin’s unremitting leading,
Tatung continued to grow and prosper through incessant endeavor in accumulation of capital power,
technical power and management power during the past decades. At present, Tatung Company has more
than 40 subsidiaries around the world, 35,000 employees including 15,000 overseas and over 220,000
shareholders including 20,000 employee-shareholders. Tatung now produces and markets more than 300
different kinds of products and the annual worldwide sales reach US$ 6.8 billion. Tatung has become an
international and diversified industrial company of long history and grand scale in the field of heavy
electric products, electronic products, electric appliances and information products in Taiwan.

4
TATUNG CO. ORGANIZATION CHART

5
1.1.2 Tatung electric motors

Tatung is the first manufacturer of electric motors in Taiwan. Adhering to the commitment and credit
to its customers, Tatung has been providing both domestic and overseas customers with high quality and
high performance electric motors. Tatung motor plant is the first one awarded the National Q. C. Group
Prize and the certificates of ABS and CR in Taiwan. Tatung’s products are also certificated by Mark,
NEMA, UL, CSA and CE. The following history witnesses Tatung’s efforts, technology and quality.

1949 Began to manufacture electric motors – The pioneer manufacturer of electric motors in Taiwan.
1959 Began to produce fractional and small size single and three phase motors.
1960 Exported electric motors to Southeastern Asia as the pioneer exporter of Taiwan motor
manufacturers.
1961 Started to produce large size and high voltage (3 kV) motors.
1968 Started to produce marine use motors, generators and blowers. Built the 1,000 HP 20 pole vertical
motor, which was the largest motor ever built in Taiwan.
1971 Produced the historic 1,000 HP 42 pole synchronous motor.
1972 Awarded the QC qualification Mark of Japan.
Began to export electric motors to Japan and Australia.
Began to build Sanhsia Plant, which was later expanded into the largest motor factory in Taiwan.
1977 Motor plant awarded the National Q. C. Group Prize.
1979 Built 1,500 kVA M-G set, GE type 400 kVA, salient pole low voltage 750 kVA, high voltage
812.5 kVA and 3,000 kVA hydraulic generators.
1982 Completed Taiwan Power Co. Ching-Liu Hydraulic Power Station turn-key project, including a
4,200 kW 12 pole 6.6 kV 60 Hz induction generator.
Started to export electric motors to U. S. A.
1983 Completed historic products: 5,700 HP 2 pole 4 kV 60 Hz WP-II induction motor and 2,250 HP 30
pole 3.3 kV 60 Hz synchronous motor.
1986 Completed Taiwan Power Co. Sui-Lien Hydraulic Power Plant turn-key system, including a 9,500
kW 18 pole 6.6 kV 60 Hz brushless synchronous generator.
1990 Built a 900 kW DC motor and a 6,500 kW 8 pole 11 kV wound rotor motor for China Steel
Corporation.
Completed a batch of motors for the FGD system of Taiwan Power Co., including 4 sets of
5000/3000 HP 8/10 pole motors.
1991 Established automatic assembly line for frame size #160 ~ #225.
Set up new tandem progressive press system for medium size motors and high speed notching
press system for large motors.
1993 Motor plant awarded ISO 9001 quality assurance certificate.
1994 Completed Taiwan Power Co. Kao-Pin Hydraulic Power Plant, including 2 sets of 2,250 kW 18
pole generators.
1996 Completed 3 phase 12.6 MW 11 kV diesel engine AC co-generation power plant.
1997 Completed Formosa Plastic 2,900 kW 22 pole & 16 pole 6.6 kV high thrust vertical motors.
Completed IEEE-841 severe duty premium efficiency NEMA series motors up to 300 HP.

6
Completed energy efficient series induction motors up to 300 HP meet U.S.A. EPACT 1997.
1999 Sanhsia Plant awarded ISO 14001 certificate from SGS.
Completed 4,500 HP 6 pole 13.8 kV historic highest rated voltage motor for Canadian steel
company.
2000 Completed 2,900 kW 6 pole and 2,650 kW 6 pole 6.6 kV 60 Hz internal-type slip ring wound rotor
induction motor for Vietnam Mining Mill application.
High temperature-resistant smoke evacuation blower driven motors awarded TÜV certificate.
2001 Completed a batch of high voltage motors for Taiwan Power Co. Taichung Power Plant #9, #10
boiler system. (including 6,500/3,400 kW 8/10 pole ID fan drive motors)
2002 Obtained CSA safety certificate for high voltage electric motors up to 8,000 HP 11.4 kV.
Obtained CSA safety certificate for high voltage electric motors up to 8,000 HP 11.4 kV.
Built 8,840 kW (11,850 HP) 4 pole 6.6 kV compressor drive motor for local gas company.
Obtained UL certificate for low voltage Division I explosion-proof motors up to 200 HP.

Based on many years experiences and continuously promoted technology, Tatung has established a
full series of industrial motors and rotating machines as listed below. Besides, owing to comprehensive
understanding of various applications and active and flexible design and manufacturing capabilities,
Tatung can offer most special motors to suit customers’ specific demands.

l STANDARD MOTORS
Cast Iron Motors -- up to IEC frame size 450, low voltage / high voltage, TEFC / ODP
Large Size Steel-Plate Frame Motors -- IEC frame size 400 ~ 710, high voltage, TEFC

l EXPLOSION-PROOF MOTORS
Increased Safety ( EXe ) Motors -- IEC frame size 63 ~225
Flameproof ( EXd ) Motors -- IEC frame size 71 ~ 160

l MISCELLANEOUS APPLICATIONS
Brake Motors -- IEC frame size 63 ~ 112
Crane Motors -- IEC frame size 132 ~ 400 (15%ED ~ 100%ED)
Smoke Evacuation Blower Driven Motors -- IEC frame size 80 ~ 200
Steel Rolling Motors -- IEC frame size 450 ~ 800
Vertical Motors -- up to IEC flange size FF1320 (equivalent to horizontal frame size 710)
Generator Assembly -- 20 kW ~ 20,000 kW
Wound Rotor Motors
Synchronous Motors and Generators
EC Variable Speed Motors
Reducer Motors
Elevator Motors
Marine Motors
High Efficiency Motors
NEMA Standard Motors

7
1.2 Technical Information

To equip an electric motor for industrial applications, many technical aspects, such as electrical
requirements, mechanical requirements, facilities and environmental conditions, need to be considered and
then an optimal and suitable selection can be made. The commonly concerned technical information is
introduced in the following sections.

1.2.1 Output

Output rating of electric motors should be determined to suit loading and necessary power of driven
equipment. Over rating is not economical since it not only costs excess money for larger motor size but
also reduces operation efficiency and power factor. On the other hand, insufficient rating may cause
starting failure and / or running trouble due to continuous over-load operation.

The necessary output for different loading can be calculated by different equations. Some common
examples are shown in the following table.

Load type Equation Symbol definition

T´ N T: necessary torque (kg-m)


General P( kW ) =
974 N: rotation speed (rpm)
Q: flow quantity (m3/min)
Q´H
Pump P(kW ) = H: total head (m)
6.12 ´ h η:pump efficiency
Q: air flow quantity (m3/min)
Q´H´K H: air pressure (mmAq)
Fan / Blower P(kW ) =
6120 ´ h K: factor (see below table)
η:blower efficiency(see below table)
Q: outlet air quantity (m3/min)
5.83Q ´ (p 0.286 - 1)
Compressor P(kW ) = p: outlet absolute pressure (kg/cm2)
h η:compressor efficiency(0.5~0.8)
W: lifting total weight (ton)
W´V
Crane (hoist) P(kW ) = V: upward speed (m/min)
6.12 ´ h η:mechanical efficiency

Blower type Blower efficiency η Factor K


Propeller fan 0.5 ~ 0.75 1.3
Desk fan 0.3 ~ 0.5 1.5
Turbo fan (above 500HP) 0.65 ~ 0.75 1.15 ~ 1.25
Turbo fan (under 500HP) 0.6 ~ 0.7 1.15 ~ 1.25
Plate fan 0.5 ~ 0.6 1.15 ~ 1.25
Turbo blower (one stage) 0.6 ~ 0.75 1.10 ~ 1.20
Turbo blower (multi-stage) 0.55 ~ 0.7 1.10 ~ 1.20

8
In general, the evaluated value of necessary output of driven machine plus 5% ~ 15% to
accommodate voltage or efficiency variation is set as the required output rating for continuous duty. In
IEC standard, there are recommended preferred rated output values in series. It would be better the
decided output values are in accord with those shown in the standard. Some common larger values in that
series are shown below.

Primary series of preferred output values (kW)

150 250 355 475 630 850 1250

160 280 375 500 670 900 1500

185 300 400 530 710 950

200 315 425 560 750 1000

220 335 450 600 800 1120

1.2.2 Voltage

Rated voltage has an important connection with output of electric motors. It is impractical to build
motors of all output ratings for all rated voltage. Proper decision of rated voltage can not only facilitate
motor performance but also put the equipment in economical commissioning and operation. The relation
between voltage and corresponding suitable range of output rating of three phase induction motors is
demonstrated by the following drawing.

37kW 150kW
200V

300kW 500kW
400V

37kW 150kW 5000kW


3kV

150kW 370kW 10000kW


6kV

2000kW 5000kW
10kV

Easily produced and preferred range

Within reach of technology

9
There are different rated voltages and frequencies in different countries, e.g. low rated voltage is
380V/50Hz in main European countries but 230V/460V/60Hz in the United States. Tatung motors are
produced for wide voltage ranges and both frequencies and thus can serve the global market.

1.2.3 Duty

Duty is the statement of the loads to which the motor is subjected, including starting, electric braking,
and no-load and rest periods, and including their duration and sequence in time. There are four basic duty
types, i.e., continuous running duty, short-time duty, periodic duty and non-periodic duty. These duty types
are classified by symbols S1, S2… and S10 in IEC Standard. Definitions of the designation are introduced
in the following table.

The customer should specify the duty type by numerically describing where the load varies or not in
a known manner, or by a time sequence graph of variable quantities, or by simply selecting a suitable class
designation. In the absence of declaration of the duty type, continuous running duty S1 will be assumed to
apply. All outputs given in this catalog are based on continuous running duty S1.

Specifying
Symbol Operation Illustration Definition
Example

Operation at constant load of sufficient


Continuous
S1 duration for thermal equilibrium to be S1
running duty
reached.

Operation at constant load of a given


time, less than that required to reach
thermal equilibrium, followed by a rest
S2 Short-time duty S2 60 min.
and de-energized period of sufficient
duration for motor temperature to fall
within 2K of coolant temperature.
A sequence of identical duty cycles,
each including a period of operation at
Intermittent constant load and a period at rest and
S3 S3 25%
periodic duty de-energized. The cycle duration is
short and the starting current doesn’t
significantly affect temperature rise.
A sequence of identical duty cycles,
Intermittent each including a significant starting
S4 periodic duty time, a period of operation at constant S4 25% Jm
with starting load and a period at rest and
de-energized.
A sequence of identical duty cycles,
Intermittent
each including a starting time, a period
periodic duty
S5 of operation at constant load, a period of S5 25% Jm
with electric
electric braking and a period at rest and
braking
de-energized.

10
A sequence of identical duty cycles,
Continuous-ope each including a period of operation at
S6 ration periodic constant load and a period of operation S6 40%
duty at no load. There is no period at rest and
de-energized.
A sequence of identical duty cycles,
Continuous-ope
each including a starting time, a period
ration periodic
S7 of operation at constant load and a S7 Jm
duty with
period of electric braking. There is no
electric braking
period at rest and de-energized.
A sequence of identical duty cycles,
each including a period of operation at
Continuous-ope
constant load corresponding to a S8 Jm
ration periodic
predetermined speed, followed by one 25kW 740rpm 15%
S8 duty with
or more periods of operation at other 60kW 1460rpm 25%
related load / 45kW 980rpm 60%
constant loads corresponding to
speed changes
different speeds. There is no period at
rest and de-energized.
Duty with
A duty in which load and speed
non-periodic
S9 generally vary non-periodically within S9
load and speed
the permissible operating range.
variations
A duty consists of not more than four
Duty with
discrete loads, each being maintained
S10 discrete S10 p/∆t TL
for sufficient duration for thermal
constant load
equilibrium to be reached.
* Moment of inertia of motor, Jm, and relative thermal life expectancy, TL, are generally provided by
motor manufacturer.

1.2.4 Torque

The torque value of a motor varies with its rotation speed and the torque characteristic depends on the
electrical construction of rotor. A typical torque-speed curve is shown below.

Breakdown torque
(Maximum torque)
Torque

Full load torque


Locked rotor torque
Pull up torque Synchronous speed
(Starting torque)
Speed
Rated speed

In order to drive the driven machine, motor torque must be larger than “load torque”, which is
required to overcome the inertia of the driven machine. The load torque characteristic is very different for
various load types. Customer should declare the load type and motor manufacturer must sufficiently
understand the load torque characteristic so that they can determine the optimal motor torque
11
characteristic by suitable electrical design of rotor. Some typical load characteristics are listed in the
following table.

Starting Condition Load Torque Characteristic Example

Medium starting torque and constant shaft torque M-G set, refiner, grinder
during operation. Starting and acceleration are
Can be started on
easy due to small GD2.
little partial load
Small starting torque. Shaft torque varies with Centrifugal pump, fan, blower
speed in exponential relation.
Reciprocating machine, such as air or gas Reciprocating machine
Can be started on compressor, usually requires larger starting Compressor
little partial load torque. Shaft torque is very different for various Pump
type of machine. Vacuum pump
Large torque is required for re-starting after
machine stopped. It may damage the machine to
Must be started on no Attrition mill, hammer mill,
re-start without removing the inside material
load crusher
even enough re-starting torque is given. This
means the machine can’t bear starting on load.

Machines with small GD2 but requiring large Ball mill, rod mill,
starting torque and shaft torque intrinsically reciprocating pump
unsuitable for operation on no load.
Must be started on
Machines which must bear the extreme severe Banbury mixer, roll mill, brass
full load
starting condition. e.g., rubber mill must be fine mill
re-started on full load after stopped during
operation, otherwise all inside material will go
into the discard.

1.2.5 Insulation

An electric motor’s insulation system is an assembly of insulating materials which separate electrical
components from each other and prevent short circuits and winding burnout and failure. The endurance of
the insulation system is affected by many factors such as temperature, electrical and mechanical stresses,
vibration, harmful atmosphere and chemicals, moisture, and dirt, etc. Because temperature is very often
the dominating ageing factor on insulating materials and insulation system of electric motors, the
insulation systems are divided into classes according to their thermal endurance. Some common classes
and corresponding temperature limits are shown in the following table.

Insulation Class Maximum Winding Temperature Temperature Rise

A 105o C 60 K

E 120o C 75 K

B 130o C 80 K

12
Insulation Class Maximum Winding Temperature Temperature Rise

F 155o C 105 K

H 180o C 125 K

l Maximum ambient temperature 40o C


l Temperature measurement method: Resistance method

Tatung standard motors are designed to have class F insulation with class B temperature rise. This
gives an extra 25o C thermal safe margin. There is a rule of thumb that says a 10o C rise reduces the
insulation life by half, while a 10o C decrease doubles the insulation life. Thus such design will
significantly extend the insulation life.

1.2.6 Starting methods

Some starting methods can be adopted according to power supply facilities, limitation of starting
current, starting torque and acceleration characteristic, impact on driven machine and other specifications
and requirements. Two common methods, Full voltage starting and Y-∆ starting, are introduced as follows.

Direct-on-line (D.O.L.) starting (Full voltage starting)


The simplest way to start a squirrel cage motor is to connect it directly to the main power supply. In
this case, a direct-on-line (D.O.L.) starter is the only required starting equipment. When the supply voltage
(rated voltage) is directly exerted on the motor, it will result in starting current of about 500% ~ 700% of
full load current. This high starting current will cause significant voltage drop and, if the power supply
capacity is not high enough, will damage the other machines connected to the same power supply.
Nevertheless, D.O.L. starting is still a pretty common starting method. What range of the output rating can
D.O.L. starting be acceptable depends on power supply capacity, cable size and voltage drop.

Y-∆ starting
If high starting current may have significant effect on the relevant equipment, the Y-∆ starting
method can be employed. The motor is started with the winding Y-connected where the phase voltage will
be of 1/ 3 of the line voltage and the starting current will be reduced to 1/3 of the value for ∆-connection,
i.e., the starting current will be about 200% of full load current. The winding should be switched to ∆-
connection after the motor started and the running speed up to 70% ~ 90% of rated speed. On the other
hand, the starting torque will be also reduced to about 1/3 of the value for D.O.L. starting. Therefore, one
must check if the reduced starting torque is larger than the load torque and thus sufficient to accelerate the
load during the whole speed range.

Y-∆ starting method is usually used for motors of low voltage and low output rating since high
starting current has more influence on such motors.

13
1.2.7 Efficiency

The typical efficiency values for the rated output on full load and partial load, say, 3/4 load, 1/2 load
and 1/4 load, are listed in chapter 4. Tatung can supply guaranteed high efficiency values and partial load
values upon request.

1.2.8 Power factor

The power of a motor is consumed in two parts. The first part is used to perform mechanical work
and regarded as effective power or real output. The other part is used for magnetization but doesn’t
perform any work and thus regarded as non-effective power.

Power factor is defined as the ratio of effective power, measured in kW, to the whole power including
the non-effective power, measured in kVA. The definition of power factor is usually illustrated by the
following diagram.

S (whole power, kVA)


Q (non-effective power)

P (effective power, kW)


Power factor, PF = P / S = cosθ

The power factor is usually between 0.7 and 0.9. Typical power factor values for the rated output on
full load and partial load are listed in the performance data tables in chapter 4. Tatung can supply other
guaranteed values upon request.

Low power factor means the motor has large portion of non-effective power consumed and thus the
whole power consumed will increase. To reduce power loss and voltage drop in the wiring circuit and
increase the load capacity in the power facilities, it is necessary to improve power factor. In general, the
most economical method is to install a power factor correction capacitor.

1.2.9 Enclosure

The enclosure type of motors is mainly concerned with protection degree and cooling method of
motors. In IEC standard, protection degree and cooling method are classified by letters IP and IC followed
by characteristic numerals.

14
IP Designation

IP 4 4 (W)

Code letters
st
1 characteristic numeral for protection of persons against contacts with or
approach to live parts and against contacts with moving parts and protection of
the machine against ingress of solid foreign objects.
nd
2 characteristic numeral for protection of machine against harmful effects
due to ingress of water.

“W” is used for air-cooled open motors which are weather-protected for specific weather conditions.
st
Degrees of protection indicated by the 1 characteristic numeral

First characteristic Degree of protection


numeral Brief description Definition

0 Non-protected machine No special protection


Machine protected against Accidental or inadvertent contact with or approach to
solid objects greater than live and moving parts inside the enclosure by a large
50 mm surface of the human body, such as a hand
Ingress of solid objects exceeding 50 mm in diameter
Machine protected against Contact with or approach to live or moving parts
solid objects greater than inside the enclosure by fingers or similar objects not
12 mm exceeding 80 mm in length
Ingress of solid objects exceeding 12 mm in diameter
Machine protected against Contact with or approach to live or moving parts
solid objects greater than inside the enclosure by tools or wires exceeding 2.5
2.5 mm mm in diameter
Ingress of solid objects exceeding 2.5 mm in diameter
Machine protected against Contact with or approach to live or moving parts
solid objects greater than inside the enclosure by wire or strips of thickness
1mm greater than 1 mm
Ingress of solid objects exceeding 1 mm in diameter
Dust-protected machine Contact with or approach to live or moving parts
inside the enclosure
Ingress of dust is not totally prevented but dust doesn’t
enter in sufficient quantity to interfere with satisfactory
operation of the machine

In NEMA standard, there is additional degree of protection indicated by the 1st characteristic numeral
designated “6”. It is used for dust-protected machine and its definition is:
”Contact with or approach to live or moving parts inside the enclosure / No ingress of dust”

15
nd
Degrees of protection indicated by the 2 characteristic numeral

Second characteristic Degree of protection


numeral Brief description Definition

0 Non-protected machine No special protection


Machine protected against Dripping water (vertically falling drops) shall have no
dripping water harmful effect

Machine protected against Vertically dripping water shall have no harmful effect
dripping water when tilted when the machine is tilted at any angle up to 15o from
up to 15o its normal position

Machine protected against Water falling as a spray at an angle up to 60o from the
spraying water vertical shall have no harmful effect

Machine protected against Water splashing against the machine from any
splashing water direction shall have no harmful effect

Machine protected against Water projected by a nozzle against the machine from
water jets any direction shall have no harmful effect

Machine protected against Water from heavy seas or water projected in powerful
heavy seas jets shall not enter the machine in harmful quantities

Machine protected against Ingress of water in the machine in a harmful quantity


the effects of immersion shall not be possible when the machine is immersed in
water under stated conditions of pressure and time

8 Machine protected against The machine is suitable for continuous submersion in


continuous submersion water under conditions which shall be specified by the
manufacturer

IC Designation
IC 4 A 1 A 1
Code letters
The first numeral indicates cooling circuit arrangement and is valid for
both primary and secondary circuits.
First pair of letter and numeral indicates the coolant and the method of
movement of the coolant respectively for the primary circuit.
Second pair of letter and numeral indicates the coolant and the method of
movement of the coolant respectively for the secondary circuit.

16
Circuit arrangement indicated by the first characteristic numeral
Charac-ter
istic Brief description Definition
numeral
Free circulation The coolant is freely drawn directly from the surrounding medium,
0 cools the machine, and then freely returns directly to the surrounding
medium (open circuit).
Inlet pipe or inlet The coolant is drawn from a medium remote from the machine, is
1 duct circulated guided to the machine through an inlet pipe or duct, passes through the
machine and returns directly to the surrounding medium (open circuit).
Outlet pipe or outlet The coolant is drawn directly from the surrounding medium, passes
duct circulated through the machine and is then discharged from the machine through
2 an outlet pipe or duct to a medium remote from the machine (open
circuit)
Inlet and outlet pipe The coolant is drawn from a medium remote from the machine, is
or duct circulated guided to the machine through an inlet pipe or duct, passes through the
3 machine and is then discharged from the machine through an outlet pipe
or duct to a medium remote from the machine (open circuit).
Frame surface cooled The primary coolant is circulated in a closed circuit in the machine and
gives its heat through the external surface of the machine (in addition to
the heat transfer via the stator core and other heat conducting parts), to
4 the final coolant which is the surrounding medium. The surface may be
plain or ribbed, with or without an outer shell to improve the heat
transfer
Integral heat The primary coolant is circulated in a closed circuit and gives its heat
5 exchanger (using via a heat exchanger, which is built into and forms an integral part of the
surrounding medium) machine, to the final coolant which is the surrounding medium.
Machine-mounted The primary coolant is circulated in a closed circuit and gives its heat
heat exchanger via a heat exchanger, which is mounted directly on the machine, to the
6 (using surrounding final coolant which is the surrounding medium.
medium)
Integral heat The primary coolant is circulated in a closed circuit and gives its heat
7 exchanger (using via a heat exchanger, which is built into and forms an integral part of the
remote medium) machine, to the secondary coolant which is the remote medium.
Machine-mounted The primary coolant is circulated in a closed circuit and gives its heat
heat exchanger via a heat exchanger, which is mounted directly on the machine, to the
8 (using remote secondary coolant which is the remote medium
medium)
Separate heat The primary coolant is circulated in a closed circuit and gives its heat
exchanger (using via a heat exchanger, which is separate from the machine, to the
9 surrounding or secondary coolant which is either the surrounding or the remote medium
remote medium)

Coolant designation
Characteristic letter coolant
A* Air
F Freon
H Hydrogen
N Nitrogen
C Carbon dioxide
W Water
U Oil
*Letter(s) “A” can be omitted in the simplified designation.

17
Method of movement of the coolant
Charac-ter
istic Brief description Definition
numeral
Free convection The coolant is moved by temperature differences. The fanning action of
0 the rotor is negligible.
Self-circulation The coolant is moved dependent on the rotational speed of the main
machine, either by the action of the rotor alone or by means of a
1 component designed for this purpose and mounted directly on the rotor
of the main machine, or by a fan or pump unit mechanically driven by
the rotor or the main machine.
2, 3, 4 Reserved for future use
Integral independent The coolant is moved by an integral component, the power of which is
component obtained in such a way that it is independent of the rotational speed of
5 the main machine, e.g. an internal fan or pump unit driven by its own
electric motor.
Machine-mounted The coolant is moved by a component mounted on the machine, the
independent power of which is obtained in such a way that it is independent of the
6 component rotational speed of the main machine, e.g. a machine-mounted fan unit
or pump unit driven by its own electric motor.
Separate and The coolant is moved by a separate electrical or mechanical component
independent not mounted on the machine and independent of it or is produced by the
7 component or coolant pressure in the coolant circulating system, e.g. supplied from a water
system pressure distribution system, or a gas main under pressure.
Relative The movement of the coolant results from relative movement between
8 displacement the machine and the coolant, either by moving the machine through the
coolant or by flow of the surrounding coolant (air or liquid).
All other components The movement of the coolant is produced by a method other than
9 defined above and shall be fully described

Illustrations of IC designation of the motors in the scope of this book are as follows.

Complete designation: IC 4A1A1


Simplified designation: IC 411

Complete designation: IC 6A1A1


Simplified designation: IC 611

In NEMA standard, enclosure types are also classified and defined by descriptive terminology. Some
most common types and similar IP and IC classification of IEC standard are introduced as follows.

Open Drip-Proof (ODP) è similar to IEC IP12, IC01


ODP motors have ventilating openings which permit passage of external cooling air over and around
the windings. These openings are so constructed that successful operation is not interfere with when drops
of liquid or solid particles strike or enter the enclosure at any angle from 0 to 15 degrees downward from
the vertical. ODP motors are usually used in relatively clean and indoor applications.

18
Totally Enclosed Fan Cooled (TEFC) è similar to IEC IP54, IC411
A totally enclosed fan cooled motor is a frame-surface cooled totally enclosed motor equipped for
self exterior cooling by means of a fan or fans integral with the motor but external to the enclosing parts.
TEFC motors are usually used in outdoor, dusty or saline area.

Totally Enclosed Air to Air Cooled (TEAAC) è similar to IEC IP54, IC511 / IC611
A totally enclosed air-to-air cooled motor is a totally enclosed motor which is cooled by circulating
the internal air through an air-to-air heat exchanger which, in turn, is cooled by circulating external air.
Internal air and external air is circulated by the fans integral with the rotor shaft but interior and exterior to
the enclosing parts respectively. TEAAC motors are suitable for outdoor, dusty or saline applications

Weather Protected Type II (WP-II) è similar to IEC IP23W, IC01


A weather protected type II motor is an open motor which ventilating passages at both intake and
outlet are so arranged that high velocity air and airborne particles blown into the motor by storms or high
winds can be discharged without entering the internal ventilating passages leading directly to the electric
parts of the motor itself. The nominal path of the ventilating air which enters the electric parts of the motor
shall be so arranged by baffling or separate housings as to provide at least three abrupt changes in
direction, none of which shall be less than 90 degrees. In addition, an area of low velocity not exceeding
600 ft/min shall be provided in the intake air path to minimize the possibility of moisture or dirt being
carried into the electric parts of the motor. WP-II motors can be used in indoor and outdoor but
non-corrosive area.

1.2.10 Mounting Arrangement

There are several mounting arrangements for electric motors, including foot-mounted,
flange-mounted and foot mounted with flange, etc. In general, customers specify motors just by
descriptive statement such as “horizontal foot mounted”. However, to specify a motor definitely, the
international standard mounting designation should be used. In IEC standard, types of construction and
mounting arrangements are classified by two IM code systems. Some common mounting arrangements
and corresponding IM designations are listed below.
Code I / Code II
IM B3 / IM 1001 (horizontal foot mounted)

IM V5 / IM 1011 (vertical shaft down foot mounted)

IM B5 / IM 3001 (horizontal flange mounted)

19
IM V1 / IM 3011 (vertical shaft down flange mounted)

IM B35 / IM 2001 (horizontal foot and flange mounted)

IM V15 / IM 2011 (vertical shaft down foot and flange mounted)

1.2.11 Environmental conditions

Standard motors are designed for operation in the environmental conditions of maximum ambient
temperature 40℃ and maximum altitude 1000 meter above sea level. If the site operating conditions
deviate from those stated above, some corrections should be given to temperature rise limits. The basic
rule is that the temperature rise limit should be reduced for ambient temperature beyond 40℃ or altitude
larger than 1000 meter. The adjustments according to IEC standard are listed below.

Adjustment to temperature rise limit (∆T) Examples for class B


Environmental conditions
shown in the table in §1.2.5 (∆T=80K)
May be increased by agreement by the
T=30℃è∆T=90K
amount, which shall not exceed either the
0℃≦T≦40℃
Maximum amount by which the ambient temperature
T=5℃è∆T=110K
ambient is less than 40℃ or a maximum of 30K.
temperature or Reduced by the amount by which the
air inlet 40℃<T≦60℃ T=50℃è∆T=70K
ambient temperature exceeds 40℃
temperature, T
T<0℃
By agreement
or T>60℃
H≦1000m No adjustment
Reduced by 1% of the specified
1000m<H≦4000m
temperature rise for H≦1000m for every H=2500m è ∆T
and max. ambient
100m of altitude in excess of 1000m reduced by 80K * 1 %
temperature
Adjustment due to specified max. ambient *(2500-1000)/100=68K
specified
Altitude, H temperature should be also considered.
1000m<H≦4000m No adjustment
and max. ambient It is assumed the reduced cooling due to
temperature not altitude is compensated by the reduction of
specified max. ambient temperature below 40℃
H>4000m By agreement

20
The design for reduced temperature rise limit can be reached by output de-rating. The evaluation rule
is “square of output value proportional to temperature rise”. e.g., if the temperature rise of a 300kW motor
is to be reduced from 80K to 70K, the de-rated output value can be calculated as follows,

DT2 70
P2 = ( ) ´ P1 = ( ) ´ 300 = 280.6kW
DT1 80

If the output value is to be kept the same without de-rating, then the design may be special and
different from that of standard motors and need extra cost to standard listed price. The additional prices
considering reduced temperature rise are introduced in chapter 5.

1.2.12 Bearings

Bearing arrangement
Bearings are generally classified into two groups, anti-friction bearings (or rolling bearings) and
sleeve bearings. Anti-friction bearings are widely used for various applications while sleeve bearings are
mainly used in larger high speed or heavy loading machines.

In Tatung standard series of cast iron frame motors and some steel-plate frame motors, single row
deep groove ball bearings are used in both drive end and non-drive end. For applications with large radial
load, e.g., belt drive applications, NU- type roller bearings are used instead of ball bearings in drive end.
Three-bearing arrangement may be adopted with one NU- bearing in non-drive end and one ball bearing
and one NU- bearing in drive end. Customer should specify belt pulley data for motor maker to select
suitable bearings with satisfactory bearing life.

If there exists axial load, the most common applications are vertical motors where axial load comes
from rotor weight itself and downward axial thrust, axial load capacity should be considered. For motors
suffering smaller axial load, ball bearing in non-drive end may have sufficient axial load capacity, but for
motors with large axial load or large frame size vertical motors with axial thrust, angular contact ball
bearings or spherical roller thrust bearings are fitted to ensure reliable operation. When ordering a motor,
customer should specify the direction and magnitude of axial force if there is.

Some typical bearing arrangements are shown in the following pages.

Bearing life
Anti-friction bearing life is normally defined, according to the ISO definition, as the number of
revolutions or the number of operation hours before fatigue failure occurs that 90% of a sufficiently large
group of identical bearings can attain or exceed at a constant speed and under specific conditions. This life
definition implies 90% reliability and is called basic rating life, L10. ISO has introduced an adjusted rating
life equation as
C
L10a = a 1 ´ a 2 ´ a 3 ´ L10 = a 1 ´ a 2 ´ a 3 ´ ( ) p
P

21
where
L10a ≡ adjusted rating life, millions of revolutions (can be translated to operating hours)
L10 ≡ basic rating life, millions of revolutions (can be translated to operating hours) = ( C / P )p
C ≡ basic dynamic load rating, N
P ≡ equivalent dynamic bearing load, N
p ≡ exponent of the life equation
p = 3 for ball bearings
p = 10/3 for roller bearings
a1 ≡ adjustment factor for reliability
a1 = 1 for 90% reliability
a2 ≡ adjustment factor for material
a1 = 1 for material meets ISO definition
a3 ≡ adjustment factor for operation conditions (essentially lubrication condition)
a3 can be determined from bearing handbook

There is few international standards have criteria of acceptable bearing life for electric motors. In
general, it depends on agreement between customer and motor supplier. If bearing life is not specified by
customer, motor makers will select bearings based on their own standard. Normally, bearing life of a few
million operating hours, say 25,000 hours, is regarded acceptable if no special or severe operating
conditions are specified.

As for sleeve bearings, there is no simple method to evaluate bearing life and thus it is usually not
specified when ordering a motor. Other dynamic performance data, including oil film temperature, can be
computed. However, it is pretty complicated and can usually be executed only by professional sleeve
bearing manufacturer.

Lubrication
Grease can be used to lubricate rolling bearings under normal operating conditions in most
applications while oil lubrication is mainly used for high speed and high temperature operation and
spherical roller thrust bearings. Sleeve bearings must be also lubricated by oil.

The lubricant will gradually lose lubricating property as a result of mechanical work, ageing and
build-up of contamination. It is therefore necessary to replenish or renew the lubricant at an operation
period. There are many kinds of lubricant available in the market. Lubricants of different brand of
equivalent class may have somewhat differences of lubricating properties. Therefore motor manufacturer
should inform customer what kind of lubricant is originally filled and what the detailed lubricating
properties are so that customer can assure replenished lubricant will satisfy.

Tatung use Shell Alvania R2 grease as standard lubricant for grease lubrication motors. Its operation
temperature range is -35℃~100℃ for bearing operating at up to maximum rated speed, and up to 135℃
for bearing operating at up to 75% of maximum rated speed. Other properties are available on request. Oil
lubricant is highly concerned with loading conditions and will be determined after bearings decided.

22
1.2.13 Coupling methods

There are some coupling methods of motors with load machines. A suitable coupling method is
usually determined by the load machine supplier or the proprietor in consideration of conditions of load
machines. Coupling method is concerned with bearing selection and shaft strength of connected motors,
so customer should advise the coupling method when ordering a motor. Some typical coupling methods
are introduced as follows.

Direct coupling
The motor and load machine are coupled by a hub flange or certain part with the centerlines of motor
shaft and driven shaft aligned. There are two types of direct coupling. One is rigid coupling and the other
is flexible coupling. The former requires higher coupling assembly precision than the latter due to the
direct transmitted mechanical influence from motor shaft to driven shaft.

Belt drive
Belt drive and direct coupling are the most common coupling methods. The motor shaft and driven
shaft are mounted with pulleys and connected by belts. When driving the load machine, belt tension will
induce a radial force and thus bending stress on the motor shaft. Therefore, shaft strength and bearing life
should be checked to assure safe and reliable operation. The radial force can be derived from pulley data
as shown below. Customer should provide pulley data for motor maker to perform necessary calculation
and evaluation. If pulley data are not specified in a belt drive application, motor manufacturer may design
by his own consideration but must inform customer about the permissible radial force.

PW ≡ pulley width, mm

F ≡ radial force on shaft, kg

X ≡ distance from force position to shoulder, mm

PCD≡ pitch circle diameter of pulley, mm

N ≡ rotation speed of motor, rpm

Output (kW )
F = 1.948 ´ K ´ ´ 106
N ´ PCD

Where K is belt coefficient, varying from 2 ~ 6 and normally 2.5 for V-belt, depending on belt types.

26
Gear coupling
Gear coupling is also a method that motor shaft and driven shaft are not in alignment. For spur gear,
there will be a radial force similar to belt drive. For bevel gear or worm gear, there is additional axial force
besides radial force exerted on the motor shaft. Therefore, attention should be paid on strength calculation
in two directions.

In some cases, part of load machine, e.g., an impeller, is directly mounted or overhung on motor shaft
without use of coupling, belt or gear. There may be only radial force or axial force or both depending on
loading conditions. For these special applications, relevant detailed specifications should be obtained and
investigated between motor maker and customer or machine supplier.

1.2.14 Vibration

Abnormal large vibration level of a machine always implies a symptom of bad production or
assembly, e.g., mechanical or electrical unbalance, deformation of core or shaft, loose parts, etc. Such
vibration will induce large stress on machine construction itself or connected equipment and then shorten
the service life. Therefore, some vibration limits, such as IEC standard 34-14, are specified to assure
reliable operation.

Before vibration criteria introduced, some vibration terminology and concept are illustrated by the
following vibrating spring-mass system.

From physical and mathematical derivation, we have

vibration displacement, x = X sin wt

vibration velocity, v = dx / dt = wX cos wt = V cos wt


displacement
x
vibration acceleration, a = dv / dt = -w2 X sin wt = A sin wt

where ω is rotating angular velocity.

x
Root-mean-square value
(r.m.s. value)
peak value X
t
peak to peak value

period, T = 2π/ω
frequency, f = 1 / T

27
IEC standard 34-14 is applicable to AC motors with shaft center height 56 mm and higher and a rated
output up to 50 MW, at nominal speed from 600 rpm up to and including 3,600 rpm, and applicable only
to no-load condition. For other conditions beyond scope of the standard, a prior agreement between
purchaser and manufacturer should be reached.

The limit of vibration severity is specified in the following table, in which values are given for three
vibration grades: N (normal), R (reduced) and S (special).
Limit of vibration severity in mm/s r.m.s. for shaft center height H (mm)
Rigid
Motor of free suspension
mounted
Vibration Rated speed
56 < H ≤ 132 132 < H ≤ 225 225 < H ≤ 400 H > 400 H > 400
grade (rpm)
N 600 ~ 3,600 1.8 2.8 3.5 3.5 2.8

600 ~ 1,800 0.71 1.12 1.8 2.8 1.8


R
> 1,800 ~ 3,600 1.12 1.8 2.8 2.8 1.8

600 ~ 1,800 0.45 0.71 1.12


S
> 1,800 ~ 3,600 0.71 1.12 1.8

Notes:
1. If purchaser doesn’t specify grade, motors complying with IEC 34-14 shall be grade N.
2. Grade S is applicable only to motors with H ≤ 400 mm.
3. 2-pole motors may have significant vibration at twice the frequency of power supply. For 2-pole
motors with H > 225 mm, evaluation of such vibration components in rigid mounting shall be part of
motor type test, and the values shall not exceed those for H > 400 shown above.
4. For vertical motors, this standard is only applicable to motors measured in free suspension.

If sleeve bearings are used in 2 or 4 pole motors, relative shaft vibration measurements in peak-to
peak displacement are recommended rather than measurements in mm/s. Limits are shown as below table.
Limits for maximum relative shaft vibration (SP-P) and maximum run-out
Maximum relative shaft
Vibration grade Poles Maximum run-out (μm)
displacement (SP-P,μm)
2 70 18
N
4 90 23

2 50 12.5
R
4 70 18

Notes: the maximum relative shaft displacement limits include the run-out.

28
1.2.15 Noise

People are becoming more aware of hurt of noise to human beings in recent years and thus give more
demands on noise suppression. To evaluate how “large” a noise is, the acoustic quantities can be expressed
in two types of terms, sound power level and sound pressure level.

W
Sound power level, L W = 10 × log 10 ( )
W0
where
LW : sound power level in decibel (dB)
W : power output from the sound source in watt
W0 : basic sound output, 10-12 watt, which is defined from the minimum audible sound intensity of
human ear, 10-12 watt/m2

P 2 P
Sound pressure level (SPL), L P = 10 × log10 ( ) = 20 × log10 ( )
where
P0 P0
LP : sound pressure level in decibel (dB)
P : effective sound pressure in N/m2 (Pa). (Physically equivalent to root-mean square value of sound
pressure function of time)
W0 : basic sound pressure, 2*10-5 Pa, which is defined from the minimum audible sound pressure of
human ear

Human ears often have different hearing sense for different frequency components of the sound with
the same loudness. A correction function, A-weighting filter, is introduced in noise-meter to correct the
measured sound level in octave band to simulate human ears’ hearing perception, and the unit is expressed
as dBA. The A-weighting function curve and adjusted values corresponding to center frequencies of
octave band are shown as follows.

Center frequency 31.5 40 50 63 80 100 125 160 200 250 315 400 500
(Hz)
Adjusted value -39 -35 -30 -26 -23 -19 -16 -13 -11 -9 -7 -5 -3
(dBA)
Center frequency 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000
(Hz)
Adjusted value -2 -1 0 +1 +1 +1 +1 +1 +1 +1 0 -1
(dBA)

A-weighting function has large attenuation in


low frequency range.

29
Sound power level can be translated into sound pressure level by the following equation for motors
placed on reflective ground and emitting non-directional noise.

SPL, L P = L W - 10 × log 10 (2 pr 2 )
where
LP : average sound pressure level in a free field over a reflective plane on a hemispherical surface at 1 m
distance from the motor
r : 1 m + 0.5 * (maximum linear dimension of the measured motor in meters)

In IEC standard, maximum A-weighted sound power levels (dBA) for standard motors, at no-load,
without additional special electrical, mechanical or acoustical modifications intended to reduced noise, are
specified for a range of rated output in the following table.

Rated output, P 2 pole 4 pole 6 pole 8 pole


kW 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz
1.0 < P ≤ 2.2 85 81 71 71 71 71 71 71

2.2 < P ≤ 5.5 88 86 76 76 76 76 76 76

5.5 < P ≤ 11 91 91 81 81 80 80 80 80

11 < P ≤ 22 94 94 88 88 84 84 84 84

22 < P ≤ 37 100 96 91 91 87 87 87 87

37 < P ≤ 55 101 98 95 94 91 90 90 89

55 < P ≤ 110 104 100 98 97 95 94 93 92

110 < P ≤ 220 107 103 102 101 99 98 97 96

220 < P ≤ 400 110 107 106 105 102 101 99 98

In practice, the above values are minimum requirements for reference. Many customers usually
specify lower noise level. “Standard” motors of different manufacturers may be quite different in electrical,
mechanical and configuration design. Their noise levels may just meet or be much better than the above
limits. For customers demands beyond the above limits or for motors of rated output or poles beyond the
range of above table, the noise levels should be specified by agreement between customer and
manufacturer by considering motor size, operating speed and environmental conditions. In the scope of
this book, Tatung has set sound pressure level 85 dBA as the standard noise level, which is better than
above values and can satisfy the most customers demands.

1.3 Specifying and Ordering Motors

To make an inquiry or order motors, use of inquiry / ordering sheets of normal form will ensure
correct and prompt management. Specify requirements, standards or optional specials in the provided
space of the following sheets.
30
LARGE AC MOTOR INQUIRY / ORDERING SHEET

Inquiry / Order no.


Customer
Agent / Distributor
If requirements not
Item Requirements specified, as per Remark
Tatung standard.
1 Rated output kW HP

2 Rotor type □ Squirrel cage □ Wound rotor

3 Pole P

4 Voltage V

5 Frequency Hz

6 Insulation class Class F

7 Temperature rise ℃ (Class ) 80℃ (Class B)

8 Location □ Outdoors □ Indoors Indoors

9 Site Altitude m Under 1000 m


conditions
10 Humidity % R.H. 80% R.H.
Ambient ℃ Maximum 40℃
11
temp.
12 Load type
□ Horizontal □ Vertical IM 1001 / IM
13 Mounting
IM 3011
□ TEFC (TEAAC) □ ODP
14 Enclosure
□ WP-II □ Other
15 Protection IP

16 Cooling Method IC

17 Service factor 1.0

18 Over load % Hrs Not considered


Load WK2 at motor
19 kg-m2 If available
shaft
20 Starting method
Number of
21 One hot / Two cold
consecutive starts
22 Break down torque % FLT Tatung standard

23 Locked rotor torque % FLT Tatung standard

24 Locked rotor current % FLC Tatung standard


CW (View from
25 Direction of rotation (View from NDE)
NDE)

31
26 Coupling method □ Coupling □ Belt □ Gear Coupling
Pitch circle diameter
27 Pulley Tatung standard Belt drive only
Width
28 Bearing type □ Anti-friction □ Sleeve Tatung standard
□ Grease □ Oil (forced)
29 Lubrication Tatung standard
□ Oil (self-contained)
kg (toward DE) Including horizontal
30 Axial thrust Without
kg (toward NDE) & vertical
Vertical motors
31 Non-reverse ratchet □ With □ Without Without
only
□ Sound power level
32 Noise □ Sound pressure level (SPL) SPL 85dBA No load at 1m
dBA
33 Terminal box position □ Right □ Left □ Upper Left Viewed from DE
□ PF □ PT □ NPT
34 Terminal box conduit PF 4”
Size: inch
Stator temperature □ RTD □ Thermostat
35 Without
detector □ thermistor Qty pcs
Bearing temperature □ RTD □ Thermocouple
36 Without
detector Qty pcs / bearing
Phase Volt
37 Space heater Tatung standard
Watt
38 Base / Rail □ Rail □ Sole Plate Without

39 Anchor bolt □ With □ Without Without

40 Spare parts

41 Special Requirement

DE: Drive end NDE: Non-drive end


42 Abbreviation CW: Clockwise CCW: Counterclockwise
FLT: Full load torque FLC: Full load current

32
2. Outline Dimensions

2.1 Horizontal TEFC / TEAAC Motors

Frame size Frame type Voltage Page


N315LL ~ N355LL Cast iron fin frame ~ 6,600V 34
400LS ~ 450LL Cast iron fin frame ~ 6,600V 35
400-1120 ~ 450-1400 Steel plate frame (2 pole) 3,000V / 3,300V 36
400-1120 ~ 630-1400 Steel plate frame (4~10 pole) 3,000V / 3,300V 37
400-1120 ~ 500-1250 Steel plate frame (2 pole) 6,000V / 6,600V 38
400-1120 ~ 710-1400 Steel plate frame (4~10 pole) 6,000V / 6,600V 39

2.2 Vertical TEFC / TEAAC Motors

Frame size Frame type Voltage Page


315LL ~ 450LS Cast iron fin frame ~ 6,600V 40
400-V ~ 710-V Steel plate frame (4~10 pole) 3,000V / 3,300V 41
400-V ~ 710-V Steel plate frame (4~10 pole) 6,000V / 6,600V 42

33
3. Performance Data

3.1 Horizontal TEFC / TEAAC Motors

Rated output Frame size Voltage / frequency Page


200kW ~ 800kW N355LS ~ 450LL 460V / 60Hz 44
185kW ~ 750kW N355LS ~ 450LL 415V / 50Hz 45
150kW ~ 1500kW N315LL ~ 630-1400 3,300V / 60Hz 46
150kW ~ 1500kW N315LL ~ 630-1400 3,300V / 50Hz 49
150kW ~ 1500kW N315LL ~ 710-1250 6,600V / 60Hz 52
150kW ~ 1500kW N315LL ~ 710-1400 6,600V / 50Hz 55

3.2 Vertical TEFC / TEAAC Motors

Rated output Frame size Voltage / frequency Page


200kW ~ 800kW 355LS ~ 450LS 460V / 60Hz 58
185kW ~ 630kW 355LS ~ 450LS 415V / 50Hz 59
150kW ~ 1500kW 315LL ~ 630-V 3,300V / 60Hz 60
150kW ~ 1500kW 315LL ~ 710-V 3,300V / 50Hz 63
150kW ~ 1500kW 355LS ~ 710-V 6,600V / 60Hz 66
150kW ~ 1500kW 355LS ~ 710-V 6,600V / 50Hz 69

43
LOW VOLTAGE MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 60Hz , 460V , S.F. 1.15
Class F Insulation , 40℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUTPUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
200 710 N355LS 343 2050 274 100 210 95.0 94.5 93.0 77.0 70.0 58.0
220 710 N355LS 377 2250 302 100 210 95.0 94.5 93.0 77.0 70.0 58.0
885 N355LS 395 2500 275 100 200 95.2 94.8 93.0 83.5 79.0 70.0
250
710 N355LS 423 2500 343 90 200 95.0 94.5 93.0 78.0 71.0 60.0
885 N355LS 442 2800 308 110 210 95.2 94.8 93.0 83.5 79.0 70.0
280
710 N355LS 473 2800 384 100 210 95.2 94.8 93.0 78.0 71.0 60.0
3560 N355LS 455 3150 86 100 210 95.5 95.0 93.5 91.0 89.5 85.0
1770 N355LS 476 3150 173 100 210 95.5 95.0 93.5 87.0 83.0 74.0
315 1180 N355LS 481 3150 260 100 210 95.5 95.0 93.5 86.0 82.0 73.0
885 400LS 484 3150 347 100 210 95.5 95.0 93.5 85.5 81.0 72.0
710 400LS 518 3150 432 100 210 95.5 95.0 93.5 80.0 73.0 62.0
3560 N355LS 513 3600 97 100 210 95.5 95.0 93.5 91.0 89.5 85.0
1775 N355LS 529 3600 195 100 210 95.7 95.2 94.0 88.0 85.0 78.0
355 1180 N355LS 543 3600 293 100 210 95.5 95.0 93.5 86.0 82.0 73.0
885 400LS 546 3600 391 100 210 95.5 95.0 93.5 85.5 81.0 72.0
710 400LS 583 3600 487 110 220 95.5 95.0 93.5 80.0 73.0 62.0
3560 N355LL 542 3800 103 100 210 95.5 95.0 93.5 91.0 89.5 85.0
1775 N355LS 559 3800 206 100 200 95.7 95.2 94.0 88.0 85.0 78.0
375 1180 N355LS 573 3800 310 100 200 95.5 95.0 93.5 86.0 82.0 73.0
885 400LL 576 3800 413 100 210 95.5 95.0 94.0 85.5 81.0 72.0
710 400LL 616 3800 514 110 220 95.5 95.0 93.5 80.0 73.0 62.0
3560 N355LL 578 4000 109 100 210 95.5 95.0 93.5 91.0 89.5 85.0
1775 N355LS 596 4000 219 100 200 95.7 95.2 94.0 88.0 85.0 78.0
400 1180 N355LL 611 4000 330 100 210 95.5 95.0 93.5 86.0 82.0 73.0
885 400LL 615 4000 440 110 220 95.5 95.0 93.5 85.5 81.0 72.0
710 400LL 657 4000 549 110 220 95.5 95.0 93.5 80.0 73.0 62.0
1775 N355LL 671 4400 247 100 200 95.7 95.2 94.0 88.0 85.0 78.0
1180 400LS 679 4400 371 100 220 95.6 95.1 94.0 87.0 84.0 76.0
450
890 450LS 688 4400 492 100 210 95.5 95.0 93.5 86.0 83.0 75.0
710 450LS 739 4400 617 100 220 95.5 95.0 93.5 80.0 73.0 62.0
1780 400LS 728 4700 274 110 210 95.8 95.4 94.5 90.0 87.5 80.0
500 1180 400LL 741 4700 413 100 210 95.7 95.3 94.2 88.5 85.5 78.0
890 450LS 764 4700 547 100 210 95.5 95.0 93.5 86.0 83.0 75.0
1780 400LS 815 5200 306 110 210 95.8 95.4 94.5 90.0 87.5 80.0
560
1180 400LL 830 5200 462 100 210 95.7 95.3 94.2 88.5 85.5 78.0
1780 400LL 917 5900 345 110 210 95.8 95.4 94.5 90.0 87.5 80.0
630
1185 450LS 927 5900 518 100 200 95.8 95.4 94.5 89.0 86.0 80.0
1785 450LS 1045 6700 387 100 210 95.8 95.4 94.5 89.0 86.0 79.0
710
1185 450LL 1045 6700 584 100 200 95.8 95.4 94.5 89.0 86.0 80.0
750 1785 450LS 1104 7100 409 100 210 95.8 95.4 94.5 89.0 86.0 79.0
800 1785 450LS 1178 7600 437 100 210 95.8 95.4 94.5 89.0 86.0 79.0
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

44
LOW VOLTAGE MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 50Hz , 415V , S.F. 1.15
Class F Insulation , 40℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
185 590 N355LS 347 1900 305 110 220 95.0 94.5 93.5 78.0 72.5 61.5
735 N355LS 357 2200 265 100 210 95.0 94.7 93.5 82.0 78.0 68.5
200
590 N355LS 378 2200 330 110 220 95.0 94.5 93.5 77.5 72.0 61.0
735 N355LS 393 2400 292 100 210 95.0 94.7 93.5 82.0 78.0 68.5
220
590 N355LS 413 2400 363 110 220 95.0 94.5 93.5 78.0 72.5 61.5
735 N355LS 446 2750 331 100 210 95.0 94.7 93.5 82.0 78.0 68.5
250
590 N355LS 469 2750 413 110 220 95.0 94.5 93.5 78.0 72.5 61.5
2970 N355LS 450 3200 92 120 210 95.6 95.8 95.1 90.5 89.4 85.0
1480 N355LS 467 3050 184 110 220 95.6 95.1 94.2 87.2 83.4 74.1
280 980 N355LS 484 3050 278 100 220 95.5 95.2 94.0 84.2 80.0 75.6
740 400LS 481 3050 369 100 200 95.2 95.0 94.2 85.0 81.0 71.0
590 400LS 515 3050 462 100 200 95.2 94.8 94.0 79.5 74.0 70.0
2970 N355LS 503 3600 103 120 210 95.7 95.9 95.2 91.0 90.0 85.2
1480 N355LS 517 3400 207 120 220 95.8 95.5 94.5 88.5 84.5 75.5
315 980 N355LS 545 3400 313 100 220 95.5 95.2 94.0 84.2 80.0 75.0
740 400LS 542 3400 415 100 200 95.2 95.0 94.2 85.0 81.0 71.0
590 400LS 583 3400 520 100 200 95.2 94.8 94.0 79.0 73.5 69.5
2970 N355LL 573 4000 116 130 220 95.6 95.8 95.1 90.2 89.2 84.8
1480 N355LS 583 3800 234 110 210 95.8 95.5 94.5 88.5 84.5 75.5
355 980 N355LL 614 3800 353 100 220 95.5 95.2 94.0 84.2 80.0 75.0
740 400LL 605 3800 467 100 200 95.4 95.1 94.3 85.5 81.5 71.5
590 400LL 653 3800 586 100 200 95.2 95.0 94.0 79.5 74.0 70.0
2970 N355LL 605 4200 123 110 210 95.6 95.8 95.1 90.2 89.2 84.8
1480 N355LL 615 4000 247 110 210 95.8 95.5 94.5 88.5 84.5 75.5
375 985 400LS 649 4000 371 100 220 95.5 95.2 94.0 84.2 80.0 75.0
740 450LS 643 4000 494 100 200 95.4 95.1 94.3 85.0 81.0 71.0
590 450LS 696 4000 617 100 200 95.5 95.0 94.3 78.5 72.5 68.5
1480 355LL 653 4250 263 100 200 95.8 95.5 94.5 89.0 85.0 76.0
985 400LS 691 4350 396 100 220 95.6 95.3 94.2 84.2 80.0 75.0
400
740 450LS 686 4250 526 100 200 95.4 95.1 94.3 85.0 81.0 71.0
592 450LS 742 4250 658 100 200 95.5 95.0 94.3 78.5 72.5 68.5
1480 400LS 725 4700 296 100 220 96.0 95.8 95.0 90.0 88.0 84.0
450 985 400LL 773 4800 445 100 220 95.6 95.3 94.2 85.0 81.0 76.5
740 450LS 772 4800 592 100 200 95.4 95.1 94.3 85.0 81.0 71.0
1480 400LS 805 5200 329 100 200 96.0 95.8 95.0 90.0 88.0 84.0
500
985 400LL 855 5300 494 100 210 95.7 95.4 94.5 85.0 81.0 76.5
1480 400LL 898 5800 369 100 210 96.0 95.8 95.0 90.5 88.5 85.0
560
985 450LS 958 5900 554 90 200 95.7 95.4 94.5 85.0 81.0 76.5
1480 450LS 95 6200 394 100 200 96.2 96.0 95.2 91.0 89.0 86.0
600
985 450LL 1026 6300 594 90 200 95.7 95.4 94.5 85.0 81.0 76.5
650 1485 450LS 1033 6500 426 100 200 96.2 96.0 95.2 91.0 89.0 86.0
700 1485 450LL 1112 7200 459 100 200 96.2 96.0 95.2 91.0 89.0 86.0
750 1485 450LL 1205 7500 492 100 200 96.2 96.0 95.2 91.0 89.0 86.0
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

45
MEDIUM VOLTAGE MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 60Hz , 3300V , S.F. 1.15
Class F Insulation , 40 ℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
3550 N315LL 30.7 210 41.2 120 220 95.0 94.6 93.2 90.0 87.5 82.0
1775 N315LL 33.1 210 82.3 110 210 95.0 94.5 93.0 83.5 80.5 72.5
150 1180 N315LL 35.8 210 124 110 210 94.5 94.0 92.5 77.5 72.5 62.5
880 N315LL 37.6 225 166 130 200 93.0 92.0 90.0 75.0 68.5 56.5
705 N355LS 40.0 225 207 90 200 93.0 92.0 90.0 70.5 64.5 52.0
3550 N315LL 37.9 265 50.8 120 220 95.0 94.6 93.2 90.0 87.5 82.0
1775 N315LL 40.6 265 102 110 210 95.0 94.5 93.0 84.0 81.0 73.0
185 1180 N315LL 43.7 265 153 110 200 95.0 94.5 93.0 78.0 73.0 63.0
885 N315LL 45.1 275 204 110 220 94.5 94.0 92.5 76.0 70.5 60.0
705 N355LS 48.8 275 256 90 200 93.5 92.5 90.5 71.0 65.0 55.0
3550 N315LL 41.2 285 54.9 120 220 95.0 94.6 93.2 89.5 87.0 81.5
1775 N315LL 43.8 285 110 110 210 95.0 94.5 93.0 84.0 81.0 73.0
200 1180 N315LL 47.8 285 165 110 210 95.0 94.5 93.0 77.0 72.0 62.0
885 N315LL 48.9 295 220 110 220 94.2 93.8 92.0 76.0 70.5 60.0
705 N355LS 52.7 295 276 90 200 93.5 92.5 90.5 71.0 65.0 55.0
3550 N315LL 44.9 310 60.4 120 220 95.2 94.8 93.5 90.0 87.5 82.0
1775 N315LL 47.7 310 121 110 200 95.0 94.5 93.0 85.0 82.0 74.0
220 1180 N315LL 51.6 310 182 110 200 95.0 94.5 93.0 78.5 73.5 63.5
885 N355LS 53.2 320 242 100 200 94.5 94.0 92.5 76.5 71.0 61.0
708 400LS 56.5 320 303 90 200 94.0 93.5 92.0 72.5 66.5 57.0
3550 N315LL 51.1 355 68.6 120 220 95.2 94.8 93.5 90.0 87.5 82.0
1775 N315LL 53.7 355 137 110 200 95.2 94.7 93.2 85.5 82.5 74.5
250 1180 N315LL 58.5 355 206 100 200 95.2 94.7 93.2 78.5 73.5 63.5
885 N355LS 60.5 365 275 100 200 94.5 94.0 92.5 76.5 71.0 61.0
708 400LS 64.6 365 344 90 200 94.0 93.5 92.0 72.0 66.0 56.0
3550 N315LL 57.2 400 76.8 120 220 95.2 94.8 93.5 90.0 87.5 82.0
1775 N315LL 60.2 400 154 110 200 95.2 94.7 93.2 85.5 82.5 74.5
280 1180 N315XM 65.6 400 231 90 190 95.2 94.7 93.2 78.5 73.5 63.5
885 N355LS 66.1 400 308 100 210 95.0 94.5 93.0 78.0 72.0 62.0
708 400LL 71.2 400 385 90 200 94.2 93.8 92.5 73.0 67.0 57.0
3550 N315XM 63.8 445 86.4 120 220 95.5 95.0 94.0 90.5 88.0 83.0
1775 N315XM 68.1 445 173 110 200 95.2 94.7 93.2 85.0 82.0 74.0
315 1180 N315XM 73.7 445 260 90 190 95.2 94.7 93.2 78.5 73.5 63.5
885 N355LS 74.4 445 347 100 210 95.0 94.5 93.0 78.0 72.0 62.0
708 450LS 79.3 445 433 90 210 94.5 94.0 92.5 73.5 67.5 58.0
3550 N315XM 71.9 500 97.4 120 220 95.5 95.0 94.0 90.5 88.0 83.0
1775 N315XM 76.5 500 195 110 200 95.5 95.0 93.5 85.0 82.0 74.0
355 1180 N355LS 79.8 500 293 90 200 95.5 95.0 93.5 81.5 77.5 67.5
885 400LS 83.1 500 391 100 210 95.2 94.7 93.2 78.5 72.5 63.0
708 450LS 88.2 500 488 90 210 94.5 94.0 92.5 74.5 68.0 59.0
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

46
MEDIUM VOLTAGE MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 60Hz , 3300V , S.F. 1.15
Class F Insulation , 40 ℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
RPM
KW
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
3555 N355LS 75.9 530 103 120 220 95.5 95.0 94.0 90.5 88.0 83.0
1775 N315XM 80.8 530 206 100 190 95.5 95.0 93.5 85.0 82.0 74.0
375 1180 N355LS 84.3 530 310 90 190 95.5 95.0 93.5 81.5 77.5 67.5
885 400LL 88.9 530 413 110 220 95.2 94.7 93.2 77.5 71.5 61.0
708 450LS 92.7 530 516 90 210 95.0 94.5 93.0 74.5 68.0 59.0
3555 N355LS 81.0 565 110 120 220 95.5 95.0 94.0 90.5 88.0 83.0
1775 N355LS 84.2 565 219 120 210 95.5 95.0 93.5 87.0 84.5 77.0
400 1180 N355LL 88.8 565 330 90 200 95.5 95.0 93.5 82.5 78.5 68.5
885 400LL 93.1 565 440 100 210 95.2 94.7 93.2 79.0 73.0 64.0
708 450LS 98.9 565 550 90 210 95.0 94.5 93.0 74.5 68.0 59.0
3555 N355LL 91.0 635 123 120 220 95.6 95.2 94.2 90.5 88.0 83.0
1775 N355LS 95.3 635 247 120 220 95.5 95.0 93.5 86.5 84.0 76.5
450 1180 N355LL 99.3 635 371 90 190 95.5 95.0 93.5 83.0 79.0 70.0
885 450LS 103 635 495 100 210 95.5 95.0 93.5 80.0 74.0 65.0
708 450LL 113 635 619 90 210 95.0 94.5 93.0 73.5 67.0 58.0
3555 N355LL 101 705 137 120 220 95.6 95.2 94.2 90.5 88.0 83.0
1775 N355LL 105 705 274 120 220 95.5 95.0 93.5 87.5 85.0 78.0
500 1180 400LL 108 690 413 90 210 95.5 95.0 93.5 84.5 80.5 72.0
885 450LL 115 690 550 100 210 95.5 95.0 93.5 80.0 74.0 65.0
708 450-1120 118 690 688 80 190 95.0 94.5 93.0 78.0 71.0 62.0
3555 400LL 113 790 153 110 210 95.6 95.2 94.2 90.5 88.0 83.0
1775 N355LL 118 790 307 100 200 95.8 95.3 94.0 86.5 84.0 77.0
560 1180 400LL 121 755 462 90 210 95.5 95.0 93.5 84.5 80.5 72.0
885 450LL 131 755 616 100 210 95.5 95.0 93.5 78.5 72.5 62.5
708 450-1250 132 755 770 80 190 95.0 94.5 93.0 78.0 71.0 62.0
3550 400LL 127 890 173 110 210 95.6 95.2 94.2 90.5 88.0 83.0
1780 400LL 131 890 345 100 200 95.6 95.2 4.5 88.0 85.5 78.5
630 1180 400LL 137 850 520 90 200 95.5 95.0 93.5 84.5 80.5 72.0
885 450-1120 139 850 693 90 190 95.2 94.8 93.2 83.0 78.0 70.0
708 500-1120 150 850 867 90 200 95.2 94.8 93.2 77.0 70.0 61.0
3555 400LL 144 980 195 110 210 95.6 95.2 94.2 90.5 88.0 83.0
1780 400LL 148 980 389 100 200 95.6 95.2 94.5 88.0 85.5 78.5
710 1185 400-1120 157 940 584 90 190 95.5 95.0 94.0 83.0 80.0 71.5
885 450-1120 157 940 781 90 190 95.2 94.8 93.2 83.0 78.0 70.0
708 500-1250 169 940 977 90 200 95.2 94.8 93.2 77.0 70.0 61.0
3555 400-1120 153 1000 205 110 200 95.5 95.2 94.5 90.0 87.5 82.5
1780 400LL 156 1000 410 100 200 95.6 95.2 94.5 88.0 85.5 78.5
750 1185 400-1120 165 1000 616 90 190 95.5 95.0 94.0 83.5 80.5 72.0
885 450-1250 166 1000 825 90 200 95.5 95.0 94.0 83.0 78.0 70.0
708 500-1250 178 1000 1032 85 190 95.2 94.8 93.2 77.5 70.5 61.5
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

47
MEDIUM VOLTAGE MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 60Hz , 3300V , S.F. 1.15
Class F Insulation , 40 ℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
RPM
KW
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
3555 400-1120 162 1050 219 110 210 95.5 95.2 94.5 90.5 88.0 83.0
1780 400-1120 167 1050 438 90 200 95.2 94.8 94.0 88.0 85.0 78.0
800 1185 450-1120 170 1050 658 100 210 95.5 95.0 94.0 86.0 82.0 75.0
885 450-1250 177 1050 880 90 190 95.5 95.0 94.0 83.0 78.0 70.0
710 500-1250 193 1050 1097 80 190 95.5 95.0 94.0 76.0 69.0 60.0
3555 400-1120 182 1180 247 110 210 95.5 95.2 94.5 90.5 88.0 83.0
1780 400-1120 188 1180 492 90 200 95.2 94.8 94.0 88.0 85.0 78.0
900 1185 450-1120 190 1180 740 100 210 95.5 95.2 94.5 87.0 83.0 76.0
890 500-1120 204 1220 985 100 200 95.5 95.0 94.0 81.0 75.5 68.5
710 560-1250 213 1220 1235 90 200 95.5 95.0 94.0 77.5 70.5 61.5
3555 450-1120 201 1300 274 100 190 95.5 95.2 94.5 91.0 88.5 83.5
1780 450-1120 206 1300 547 90 200 95.5 95.2 94.5 89.0 86.0 80.0
1000 1185 450-1250 214 1300 822 100 220 95.5 95.2 94.5 85.5 81.5 74.5
890 500-1120 222 1300 1094 90 190 95.5 95.0 94.0 82.5 77.0 70.0
710 560-1250 236 1300 1372 90 200 95.5 95.0 94.0 77.5 70.5 68.5
3555 450-1120 225 1460 307 100 200 95.5 95.2 94.5 91.0 88.5 83.5
1780 450-1120 229 1460 613 90 200 95.5 95.2 94.5 89.5 86.5 80.0
1120 1185 450-1250 233 1460 921 90 190 95.5 95.2 94.5 88.0 84.0 77.0
890 500-1250 247 1460 1226 100 200 95.5 95.0 94.0 83.0 77.5 71.0
710 630-1250 250 1460 1536 90 190 95.5 95.0 94.0 82.0 76.0 70.0
3560 450-1250 250 1620 342 110 210 95.5 95.2 94.5 91.5 89.0 84.0
1780 450-1250 256 1620 684 90 200 95.5 95.2 94.5 89.5 86.5 80.0
1250 1185 500-1120 262 1620 1027 90 190 95.5 95.2 94.5 87.5 83.5 76.5
890 560-1250 276 1620 1368 80 190 95.5 95.2 94.5 83.0 77.5 71.0
710 630-1250 283 1620 1715 100 200 95.5 95.2 94.5 81.0 75.0 69.0
3560 450-1250 300 1950 410 110 210 95.5 95.2 94.5 91.5 89.0 84.0
1780 450-1250 307 1950 821 90 200 95.5 95.2 94.5 89.5 86.5 80.0
1500 1185 500-1250 316 1950 1233 100 200 95.5 95.2 94.5 87.0 83.0 76.0
890 560-1250 327 1950 1642 80 190 95.5 95.2 94.5 84.0 78.5 72.5
710 630-1400 339 1950 2058 100 200 95.5 95.2 94.5 81.0 75.0 69.0
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

48
MEDIUM VOLTAGE MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 50Hz , 3300V , S.F. 1.15
Class F Insulation , 40 ℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
2955 N315LL 31.1 215 49.4 120 230 94.8 94.4 93.0 89.0 86.5 81.0
1480 N315LL 33.4 215 98.7 110 210 94.8 94.4 93.0 83.0 80.0 72.0
150 980 N315LL 36.5 215 149 110 210 94.5 94.0 92.5 76.0 71.0 62.0
730 N315LL 37.6 215 200 120 220 93.8 93.0 91.0 74.5 68.0 56.0
585 N355LS 40.1 215 250 100 200 93.5 92.5 90.5 70.0 64.0 52.0
2955 N315LL 37.9 265 61.0 110 220 95.0 94.6 93.2 90.0 87.2 82.0
1480 N315LL 40.6 265 122 100 200 95.0 94.6 93.2 84.0 81.0 73.0
185 980 N315LL 44.2 265 184 100 200 94.5 94.0 92.5 77.5 72.5 63.5
735 N355LS 45.9 265 245 100 210 94.0 93.5 92.0 75.0 71.0 62.0
585 400LS 47.2 265 308 80 200 94.0 93.0 91.5 73.0 68.0 56.0
2955 N315LL 40.9 285 65.9 120 230 95.0 94.6 93.2 90.0 87.2 82.0
1480 N315LL 44.1 285 132 100 200 95.0 94.6 93.2 83.5 80.5 72.5
200 980 N315LL 47.8 285 199 100 200 94.5 94.0 92.5 77.5 72.5 63.5
735 N355LS 49.5 285 265 100 210 94.2 93.8 92.0 75.0 71.0 62.0
585 400LS 51.0 285 333 90 200 94.0 93.0 91.5 73.0 68.0 56.0
2955 N315LL 44.9 310 72.5 120 230 95.2 94.8 93.5 90.0 87.5 82.0
1480 N315LL 48.2 310 145 100 200 95.0 94.6 93.2 84.0 81.0 73.0
220 980 N315XM 53.1 310 219 100 210 94.8 94.4 93.0 76.5 71.0 63.0
735 N355LS 54.4 310 292 100 210 94.3 93.9 92.0 75.0 71.0 62.0
585 400LS 56.0 310 366 90 210 94.2 93.5 92.0 73.0 68.0 56.0
2955 N315LL 51.1 355 82.4 120 230 95.2 94.8 93.5 90.0 87.5 82.0
1480 N315XM 54.7 355 165 100 200 95.2 94.8 93.5 84.0 81.0 73.0
250 980 N315XM 59.9 355 248 100 200 94.8 94.4 93.0 77.0 71.5 63.5
735 N355LS 61.8 355 331 100 210 94.3 93.9 92.0 75.0 71.0 62.0
585 400LL 63.6 355 416 90 210 94.2 93.5 92.0 73.0 68.0 56.0
2955 N315XM 72.1 400 117 120 230 95.2 94.8 93.5 90.5 88.0 83.0
1480 N315XM 77.7 400 234 100 200 95.2 94.8 93.5 84.0 81.0 73.0
280 980 N315XM 84.4 400 353 100 190 95.0 94.5 93.2 77.5 72.0 64.0
735 N355LS 87.6 400 470 100 210 94.5 93.5 92.0 75.0 71.0 62.0
585 450LS 87.6 400 591 90 210 94.5 93.5 92.0 75.0 70.0 60.0
2955 N315XM 64.0 445 104 120 230 95.2 94.8 93.5 90.5 88.0 83.0
1480 N315XM 68.5 445 207 100 190 95.2 94.8 93.5 84.5 81.5 73.5
315 980 N355LS 72.4 445 313 90 200 95.2 94.8 93.5 80.0 75.5 66.0
735 400LS 74.4 445 417 90 210 95.0 94.5 93.0 78.0 73.0 65.0
585 450LS 77.8 445 524 90 210 94.5 93.5 92.0 75.0 70.0 60.0
2955 N355LS 71.9 500 117 120 220 95.5 95.0 94.0 90.5 88.0 83.0
1480 N355LS 76.1 500 234 100 210 95.5 95.0 94.0 85.5 82.5 75.0
355 980 N355LS 80.1 500 353 90 200 95.2 94.8 93.5 81.5 77.0 68.0
735 400LL 83.8 500 470 90 210 95.0 94.5 93.0 78.0 73.0 65.0
585 450LS 87.6 500 591 90 210 94.5 93.5 92.0 75.0 70.0 60.0
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE

49
MEDIUM VOLTAGE MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 50Hz , 3300V , S.F. 1.15
Class F Insulation , 40 ℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
RPM
KW
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
2955 N355LL 75.9 530 124 120 220 95.5 95.0 94.0 90.5 88.0 83.0
1480 N355LS 80.4 530 247 100 210 95.5 95.0 94.0 85.5 82.5 75.0
375 980 N355LL 84.6 530 373 90 200 95.2 94.8 93.5 81.5 77.0 68.0
735 400LL 88.5 530 497 90 210 95.0 94.5 93.0 78.0 73.0 65.0
585 450LL 92.6 530 624 100 220 94.5 93.5 92.0 75.0 70.0 60.0
2955 N355LL 81.0 565 132 110 210 95.5 95.0 94.0 90.5 88.0 83.0
1480 N355LS 84.7 565 263 100 210 95.5 95.0 94.0 86.5 83.5 77.0
400 980 N355LL 91.9 565 398 90 200 95.2 94.8 93.5 80.0 75.5 66.5
735 450LS 93.1 565 530 90 210 95.2 94.8 93.5 79.0 74.0 66.0
585 450LL 98.7 565 666 90 210 94.5 93.5 92.0 75.0 70.0 60.0
2955 N355LL 91.1 635 148 110 210 95.5 95.0 94.0 90.5 88.0 83.0
1480 N355LL 94.8 635 296 100 200 95.5 95.0 94.0 87.0 84.0 79.0
450 980 400LL 97.0 635 447 90 210 95.5 95.0 94.0 85.0 81.5 75.0
735 450LS 101 635 596 90 210 95.2 94.8 93.5 82.0 77.0 70.0
585 450-1250 104 635 749 90 200 94.5 93.5 92.0 80.0 75.0 66.0
2955 400LL 101 705 165 100 220 95.6 95.2 94.2 90.5 88.0 83.0
1480 N355LL 106 705 329 100 190 95.5 95.0 94.0 86.5 83.5 78.5
500 980 400LL 108 705 497 90 210 95.5 95.0 94.0 85.0 81.5 75.0
735 450LL 112 705 663 90 210 95.2 94.8 93.5 82.0 77.0 70.0
585 450-1250 116 705 832 90 200 94.5 93.5 92.0 80.0 75.0 66.0
2955 400LL 113 790 185 100 220 95.6 95.2 94.2 90.5 88.0 83.0
1480 400LL 119 790 369 100 200 95.5 95.0 94.0 86.5 83.5 78.5
560 980 400LL 120 790 557 90 210 95.5 95.0 94.5 85.5 82.0 77.0
735 450-1120 126 790 742 90 190 95.0 94.5 93.2 82.0 77.0 70.0
590 500-1120 129 790 924 100 210 94.8 94.2 93.0 80.0 75.0 66.0
2955 400LL 127 890 208 100 210 95.6 95.2 94.2 90.5 88.0 83.0
1480 400LL 133 890 415 100 200 95.5 95.0 94.0 87.0 84.0 79.0
630 980 400-1120 142 890 626 85 200 95.2 94.8 94.0 81.5 78.5 72.0
735 450-1120 141 890 835 90 190 95.0 94.5 93.2 82.0 77.0 70.0
590 500-1250 145 890 1040 100 200 94.8 94.2 93.0 80.0 75.0 66.0
2950 400-1120 145 1010 234 100 200 95.5 95.2 94.5 90.0 87.5 82.5
1480 400-1120 151 1010 467 90 210 95.2 94.8 94.0 86.5 83.0 76.0
710 980 450-1120 154 1010 706 90 210 95.2 94.8 94.0 85.0 81.5 74.0
735 450-1250 158 1010 941 90 190 95.0 94.5 93.2 83.0 78.0 72.0
590 500-1250 164 1010 1172 100 200 94.8 94.2 93.0 80.0 75.0 66.0
2950 400-1120 153 1065 248 100 200 95.5 95.2 94.5 90.0 87.5 82.5
1480 400-1120 159 1065 494 90 210 95.2 94.8 94.0 86.5 83.0 76.0
750 980 450-1120 162 1065 745 90 200 95.2 94.8 94.0 85.0 81.5 74.0
735 450-1250 166 1065 994 80 180 95.0 94.5 93.2 83.0 78.0 72.0
590 560-1250 173 1065 1238 100 210 95.0 94.5 93.2 80.0 75.0 66.0
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

50
MEDIUM VOLTAGE MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 50Hz , 3300V , S.F. 1.15
Class F Insulation , 40 ℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
RPM
KW
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
2950 400-1120 163 1140 264 100 200 95.5 95.2 94.5 90.0 87.5 82.5
1480 400-1120 170 1140 526 90 210 95.2 94.8 94.0 86.5 83.0 76.0
800 980 450-1120 171 1140 795 85 190 95.2 94.8 94.0 86.0 82.0 75.0
735 500-1120 180 1140 1060 90 200 95.2 94.8 94.0 81.5 76.5 70.5
590 560-1250 184 1140 1321 100 210 95.0 94.5 93.2 80.0 75.0 66.0
2950 450-1120 183 1280 297 100 200 95.5 95.2 94.5 90.0 87.5 82.5
1485 450-1120 186 1280 590 90 200 95.5 95.2 94.5 88.5 85.5 79.0
900 980 450-1250 194 1280 894 90 200 95.5 95.0 94.5 85.0 81.0 74.0
735 500-1120 204 1280 1193 90 200 95.2 94.8 94.0 81.0 76.0 70.0
590 560-1250 207 1280 1486 100 210 95.0 94.5 93.2 80.0 75.0 66.0
2950 450-1120 204 1425 330 100 200 95.5 95.2 94.5 90.0 87.5 82.5
1485 450-1120 207 1425 656 90 200 95.5 95.2 94.5 88.5 85.5 79.0
1000 980 450-1250 212 1425 994 85 190 95.5 95.2 94.5 86.5 82.5 76.0
735 500-1250 223 1425 1325 90 200 95.2 94.8 94.0 82.5 77.0 72.0
590 630-1250 224 1425 1651 90 190 95.2 94.8 93.5 82.0 76.0 70.0
2950 450-1250 228 1595 370 100 200 95.5 95.2 94.5 90.0 87.5 82.5
1485 450-1250 231 1595 735 90 200 95.5 95.2 94.5 89.0 86.0 80.0
1120 985 500-1120 236 1595 1107 85 190 95.5 95.2 94.5 87.0 83.0 76.5
735 560-1250 253 1595 1484 90 200 95.5 95.0 94.0 81.0 76.0 71.0
590 630-1250 251 1595 1849 90 200 95.2 94.8 93.5 82.0 76.0 70.0
2950 450-1250 254 1780 413 100 200 95.5 95.2 94.5 90.0 87.5 82.5
1485 450-1250 257 1780 820 85 180 95.5 95.2 94.5 89.0 86.0 80.0
1250 985 500-1250 262 1780 1236 85 190 95.5 95.2 94.5 87.5 83.5 77.0
735 560-1250 283 1780 1656 90 200 95.5 95.0 94.0 81.0 76.0 71.0
590 630-1400 283 1780 2064 100 210 95.5 95.0 94.0 81.0 75.0 70.0
2950 450-1400 305 2135 495 110 210 95.5 95.2 94.5 90.0 87.5 82.5
1485 500-1250 305 2135 984 100 210 95.5 95.2 94.5 90.0 87.5 82.5
1500 985 500-1400 314 2135 1483 85 190 95.5 95.2 94.5 87.5 83.5 77.0
735 560-1400 335 2135 1988 80 190 95.5 95.0 94.0 82.0 77.0 72.0
590 630-1400 335 2135 1321 90 200 95.5 95.0 94.0 82.0 76.0 70.0
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.

ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

51
HIGH VOLTAGE MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 60Hz , 6600V , S.F. 1.15
Class F Insulation , 40℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
3550 N315LL 15.6 110 41.2 120 220 93.5 93.0 91.5 90.0 87.5 82.0
1775 N315LL 16.7 110 82.3 110 200 93.5 93.0 91.5 84.0 81.0 73.0
150 1180 N315LL 18.3 110 124 110 200 93.0 92.2 90.0 77.0 72.0 62.0
880 N355LS 19.1 110 166 100 220 93.0 92.0 90.0 74.0 68.0 54.0
705 N355LS 21.0 110 207 100 220 92.5 91.5 89.0 67.5 60.0 47.0
3550 N315LL 19.2 135 50.8 120 220 93.8 93.2 91.8 90.0 87.5 82.0
1775 N315LL 20.4 135 102 100 200 93.8 93.2 91.8 84.5 81.5 73.5
185 1180 N315LL 22.9 135 153 110 200 93.5 93.0 91.5 75.5 70.0 60.0
880 N355LS 23.5 135 205 100 220 93.2 92.2 90.0 74.0 68.0 54.0
705 400LS 24.9 135 256 100 220 93.0 92.0 89.5 70.0 63.0 50.0
3550 N315LL 20.7 145 54.9 120 220 93.8 93.2 91.8 90.0 87.5 82.0
1775 N315LL 22.1 145 110 110 200 93.8 93.2 91.8 84.5 81.5 73.5
200 1180 N315XM 24.0 145 165 110 200 93.5 93.0 91.5 78.0 73.0 63.0
880 N355LS 25.4 145 221 100 230 93.2 92.2 90.0 74.0 68.0 54.0
705 400LS 26.9 145 276 100 230 93.0 92.0 89.5 70.0 63.0 50.0
3550 N315LL 22.8 160 60.4 120 220 93.8 93.2 91.8 90.0 87.5 82.0
1775 N315XM 24.1 160 121 110 200 94.0 93.5 92.0 85.0 82.0 74.0
220 1180 N315XM 27.0 160 182 120 210 93.8 93.2 91.8 76.0 71.0 61.0
880 N355LS 27.4 160 244 100 230 93.5 93.0 91.5 75.0 70.0 57.0
705 400LL 29.1 160 304 100 230 93.2 92.2 90.0 71.0 64.0 51.0
3550 N315XM 25.9 180 68.6 120 220 94.0 93.5 92.0 90.0 87.5 82.0
1775 N315XM 27.4 180 137 110 200 94.0 93.5 92.0 85.0 82.0 74.0
250 1180 N315XM 29.7 180 206 100 200 93.8 93.2 91.8 78.5 73.5 63.5
880 N355LL 30.8 180 277 100 220 93.5 93.0 91.5 76.0 71.0 58.0
705 400LL 32.9 180 345 100 230 93.5 92.5 91.0 71.0 64.0 51.0
3550 N315XM 29.0 205 76.8 120 220 94.0 93.5 92.0 90.0 87.5 82.0
1775 N315XM 31.0 205 154 120 220 94.0 93.5 92.0 84.0 81.0 73.0
280 1180 N355LL 33.6 205 231 90 220 94.0 93.5 92.0 77.5 72.5 62.5
885 400LS 33.8 205 308 90 220 94.0 93.5 92.0 77.0 72.0 62.0
710 450LS 36.4 205 384 90 230 93.5 92.5 91.0 72.0 65.0 53.0
3550 N315XM 32.5 225 86.4 120 220 94.2 93.7 92.2 90.0 87.5 82.0
1775 N315XM 34.6 225 173 110 210 94.2 93.7 92.2 84.5 81.5 73.5
315 1180 N355LL 36.8 225 260 90 220 94.2 93.7 92.2 79.5 74.5 65.0
885 400LL 37.0 225 347 90 210 94.2 93.7 92.2 79.0 74.0 64.0
710 450LS 40.1 225 432 90 230 94.2 93.7 92.2 73.0 66.0 55.0
3550 N355LL 36.3 255 97.4 120 230 94.5 94.0 92.5 90.5 88.0 83.0
1780 N355LL 38.0 255 194 100 210 94.5 94.0 92.5 86.5 83.5 76.0
355 1180 N355LL 41.1 255 293 90 220 94.5 94.0 92.5 80.0 75.0 66.0
885 400LL 41.6 255 391 90 220 94.5 94.0 92.5 79.0 74.0 64.0
710 450LL 44.4 255 487 90 230 94.5 93.7 92.2 74.0 67.0 56.0
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE

52
.
HIGH VOLTAGE MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 60Hz , 6600V , S.F. 1.15
Class F Insulation , 40℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
3550 N355LL 38.4 265 103 120 230 94.5 94.0 92.5 90.5 88.0 83.0
1780 N355LL 40.1 265 205 100 210 94.5 94.0 92.5 86.5 83.5 76.0
375 1185 400LL 41.3 265 308 90 220 94.5 94.0 92.5 84.0 80.0 73.0
885 400LL 43.4 265 413 100 230 94.5 94.0 92.5 80.0 75.0 65.0
710 450LL 47.2 265 514 90 230 94.5 94.0 92.5 73.5 66.5 55.0
3550 N355LL 40.9 285 110 120 220 94.5 94.0 92.5 90.5 88.0 83.0
1780 N355LL 42.6 285 219 100 210 94.5 94.0 92.5 87.0 84.0 76.5
400 1185 400LL 43.6 285 329 90 220 94.5 94.0 92.5 85.0 81.0 74.0
885 450LS 45.7 285 440 90 220 94.5 94.0 92.5 81.0 76.0 66.0
710 450LL 50.4 285 549 90 230 94.5 94.0 92.5 73.5 66.5 55.0
3550 400LL 45.6 320 123 110 210 94.8 94.4 93.0 91.0 88.5 84.0
1780 N355LL 47.6 320 246 100 200 94.5 94.0 92.5 87.5 84.5 77.0
450 1185 400LL 49.0 320 370 90 220 94.5 94.0 92.5 85.0 81.0 74.0
885 450LL 51.1 320 495 90 220 94.5 94.0 92.5 81.5 76.5 66.5
710 450-1120 53.6 300 617 90 210 94.2 93.8 92.0 78.0 72.0 60.0
3550 400LL 50.7 350 137 110 210 94.8 94.4 93.0 91.0 88.5 84.0
1780 400LL 52.7 350 274 120 210 94.8 94.4 93.0 87.5 84.5 77.0
500 1185 400LL 53.7 350 411 90 220 94.8 94.4 93.0 86.0 82.0 75.0
885 450-1120 55.8 320 550 85 200 94.5 94.0 92.5 83.0 78.0 68.0
710 450-1250 59.5 320 686 90 210 94.2 93.8 92.0 78.0 72.0 60.0
3550 400LL 56.8 390 154 110 210 94.8 94.4 93.0 91.0 88.5 84.0
1780 400LL 59.1 390 306 120 210 94.8 94.4 93.0 87.5 84.5 77.0
560 1180 400-1120 62.1 370 462 90 200 94.5 94.0 92.5 83.5 79.0 72.0
885 450-1120 62.5 370 616 85 190 94.5 94.0 92.5 83.0 78.0 68.0
710 500-1120 66.5 370 768 90 210 94.5 94.0 92.5 78.0 72.0 60.0
3550 400-1120 64.8 420 173 100 200 94.5 94.2 92.5 90.0 87.5 82.0
1780 400-1120 67.0 420 345 100 220 94.5 94.2 92.5 87.0 84.0 76.0
630 1180 400-1250 69.0 420 520 90 200 94.5 94.0 92.5 84.5 80.0 73.0
885 450-1250 70.3 420 693 85 190 94.5 94.0 92.5 83.0 78.0 68.0
710 500-1250 74.8 420 864 90 210 94.5 94.0 92.5 78.0 72.0 60.0
3550 400-1120 73.0 480 195 100 200 94.5 94.2 92.5 90.0 87.5 82.0
1785 450-1120 73.6 480 387 100 220 94.8 94.5 93.0 89.0 86.0 79.0
710 1185 450-1120 76.6 480 584 90 210 94.8 94.5 93.0 85.5 81.0 74.0
885 500-1120 78.9 480 781 90 200 94.8 94.5 93.0 83.0 78.0 68.0
710 560-1250 83.2 480 974 90 210 94.5 94.0 92.5 79.0 73.0 62.0
3550 400-1120 77.1 500 206 100 200 94.5 94.2 92.5 90.0 87.5 82.0
1785 450-1120 77.8 500 409 100 210 94.8 94.5 93.0 89.0 86.0 79.0
750 1185 450-1250 80.5 500 616 90 210 94.8 94.5 93.0 86.0 81.5 74.5
885 500-1120 83.4 500 825 90 200 94.8 94.5 93.0 83.0 78.0 68.0
710 560-1250 87.6 500 1029 90 210 94.8 94.5 93.0 79.0 73.0 62.0
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

53
HIGH VOLTAGE MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 60Hz , 6600V , S.F. 1.15
Class F Insulation , 40℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
3550 450-1120 81.4 530 219 100 200 95.0 94.5 93.0 90.5 88.0 83.0
1785 450-1250 83.7 530 437 100 220 95.0 94.5 93.0 88.0 85.0 78.0
800 1185 450-1250 85.7 530 658 90 220 95.0 94.5 93.0 86.0 81.5 74.5
885 500-1250 88.8 530 880 90 200 95.0 94.5 93.0 83.0 78.0 68.0
710 560-1250 93.4 530 1097 90 210 94.8 94.5 93.0 79.0 73.0 62.0
3550 450-1120 91.6 600 247 100 200 95.0 94.5 93.0 90.5 88.0 83.0
1785 450-1250 92.1 600 491 100 210 95.0 94.5 93.0 90.0 87.0 80.0
900 1185 500-1120 98.1 600 740 90 220 95.0 94.5 93.0 84.5 80.0 73.0
885 500-1250 100 600 991 100 220 95.0 94.5 93.0 82.5 77.0 66.5
710 560-1400 106 600 1235 100 220 94.8 94.5 93.0 78.0 72.0 61.0
3550 450-1250 102 660 274 110 210 95.0 94.5 93.0 90.5 88.0 83.0
1785 450-1250 102 660 546 100 220 95.0 94.5 93.0 90.0 87.0 80.0
1000 1185 500-1250 108 660 822 90 220 95.0 94.5 93.0 85.0 80.5 73.5
890 560-1250 112 660 1094 100 220 95.0 94.5 93.0 82.5 77.0 66.5
710 630-1250 114 660 1372 100 220 95.0 94.5 93.0 81.0 75.0 64.0
3550 450-1250 114 740 307 110 210 95.0 94.5 93.0 90.5 88.0 83.0
1785 500-1250 116 740 611 100 220 95.2 94.8 93.5 88.5 85.5 78.5
1120 1185 500-1250 118 740 921 90 220 95.2 94.8 93.5 87.0 82.0 75.0
890 560-1250 124 740 1226 90 210 95.2 94.8 93.5 83.0 78.0 68.0
710 630-1250 126 740 1536 100 220 95.0 94.5 93.0 82.0 77.0 66.0
3550 450-1400 126 820 343 110 210 95.2 94.8 93.5 91.0 88.5 84.0
1785 500-1250 130 820 682 100 220 95.2 94.8 93.5 88.5 85.5 78.5
1250 1185 500-1400 133 820 1027 90 220 95.2 94.8 93.5 86.5 81.5 74.0
890 560-1400 137 820 1368 90 200 95.2 94.8 93.5 84.0 79.0 70.0
710 630-1400 140 820 1715 90 200 95.0 94.5 93.0 82.0 77.0 66.0
3550 450-1400 151 980 412 110 210 95.2 94.8 93.5 91.0 88.5 84.0
1785 500-1400 153 980 818 100 220 95.2 94.8 93.5 90.0 87.0 80.0
1500 1185 560-1250 159 980 1233 80 200 95.2 94.8 93.5 86.5 81.5 74.0
890 560-1400 164 980 1642 85 200 95.2 94.8 93.5 84.0 79.0 70.0
710 710-1250 166 980 2058 90 200 95.2 94.8 93.5 83.0 77.5 68.0
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.

ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

54
HIGH VOLTAGE MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 50Hz , 6600V , S.F. 1.15
Class F Insulation , 40℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
2960 N315LL 15.6 110 49.4 130 230 93.5 93.0 91.5 90.0 87.5 82.0
1480 N315LL 16.6 110 98.7 100 190 93.5 93.0 91.5 84.5 81.5 74.0
150 985 N315LL 18.2 110 148 120 220 93.2 92.5 91.0 77.5 72.5 62.5
735 N355LS 19.6 120 199 120 240 93.0 92.0 90.0 72.0 66.0 54.5
588 400LS 19.6 120 248 90 220 93.0 92.0 90.0 72.0 65.5 53.2
2960 N315LL 19.1 135 60.9 120 220 93.8 93.2 91.8 90.5 88.0 83.0
1480 N315XM 20.5 135 122 110 210 93.8 93.2 91.8 84.3 81.2 73.8
185 985 N315XM 22.0 135 183 110 210 93.5 93.0 91.5 78.5 73.5 63.5
735 N355LS 23.5 140 245 120 230 93.2 92.2 90.5 74.0 68.0 57.0
588 400LL 25.0 140 306 100 230 93.0 92.0 90.0 69.5 63.0 50.5
2960 N315LL 20.6 145 65.8 120 220 93.9 93.3 91.9 90.5 88.0 83.0
1480 N315XM 22.1 145 132 110 200 93.9 93.3 91.9 84.5 81.5 74.0
200 985 N315XM 24.1 145 198 120 220 93.6 93.1 91.6 77.5 72.5 62.5
735 N355LL 24.9 150 265 120 230 93.5 92.5 91.0 75.0 69.0 58.0
588 400LL 26.8 150 331 100 230 93.2 92.2 90.5 70.0 63.5 51.0
2960 N315XM 22.6 160 72.4 130 230 94.0 93.5 92.0 90.5 88.0 83.0
1480 N315XM 24.1 160 145 100 200 94.0 93.3 91.9 84.8 81.8 74.2
220 985 N315XM 26.3 160 218 110 210 93.8 93.3 91.9 78.0 73.0 63.0
735 N355LL 27.4 170 292 120 230 93.5 92.5 91.0 75.0 69.0 58.0
588 450LS 28.6 170 364 90 220 93.5 92.5 91.0 72.0 65.5 53.0
2960 N315XM 25.7 180 82.3 130 230 94.0 93.5 92.0 90.5 88.0 83.0
1480 N315XM 27.4 180 165 100 200 94.0 93.5 92.0 84.8 81.8 74.2
250 985 N355LS 29.1 180 247 100 210 94.0 93.5 92.0 80.0 75.0 65.0
735 400LS 29.8 180 331 90 220 94.0 93.5 92.0 78.0 72.0 61.0
588 450LS 32.3 180 414 85 210 93.5 92.5 91.0 72.5 66.0 53.5
2960 N315XM 28.6 200 92.1 130 230 94.2 93.8 92.5 91.0 88.5 83.5
1480 N355LS 30.6 200 184 120 230 94.2 93.8 92.5 85.0 82.0 75.0
280 985 N355LL 32.5 200 277 100 220 94.2 93.7 92.2 80.0 75.0 65.0
735 400LL 33.4 200 371 90 210 94.0 93.5 92.0 78.0 72.0 61.0
588 450LS 35.3 200 464 80 210 93.8 93.0 91.5 74.0 67.5 55.0
2965 N355LL 32.0 225 103 120 220 94.5 94.0 93.0 91.0 88.5 83.5
1480 N355LS 33.9 225 207 120 220 94.5 94.0 93.0 86.0 83.0 76.0
315 985 N355LL 36.2 225 311 100 220 94.5 94.0 93.0 80.5 75.5 66.0
735 400LL 37.5 225 417 90 220 94.2 93.8 92.5 78.0 72.0 61.0
588 450LL 39.2 225 522 80 205 93.8 93.0 91.5 75.0 68.5 56.0
2965 N355LL 36.1 255 117 120 220 94.5 94.0 93.0 91.0 88.5 83.5
1480 N355LL 38.4 255 234 120 220 94.5 94.0 93.0 85.5 82.5 75.5
355 985 400LL 39.1 255 351 100 210 94.5 94.0 93.0 84.0 79.0 70.0
740 450LS 40.3 255 467 90 210 94.5 94.0 93.0 81.5 76.0 66.0
588 450LL 44.3 255 588 80 205 94.0 93.2 91.8 74.5 68.0 55.5
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

55
HIGH VOLTAGE MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 50Hz , 6600V , S.F. 1.15
Class F Insulation , 40℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
2965 N355LL 38.1 270 123 120 220 94.5 94.0 93.0 91.0 88.5 83.5
1480 N355LL 40.1 270 247 120 220 94.5 94.0 93.0 86.5 83.5 76.5
375 985 400LL 41.3 270 371 100 210 94.5 94.0 93.0 84.0 79.0 70.0
740 450LL 42.3 270 494 90 210 94.5 94.0 93.0 82.0 77.0 68.0
590 450-1120 44.9 270 619 100 200 94.2 93.5 92.0 77.5 71.0 59.0
2965 400LL 40.3 280 131 110 220 94.8 94.4 93.2 91.5 89.0 84.0
1480 N355LL 42.6 280 263 110 210 94.5 94.0 93.0 87.0 84.0 77.0
400 985 400LL 43.6 280 396 100 210 94.5 94.0 93.0 85.0 80.0 71.0
740 450LL 44.9 280 526 90 200 94.5 94.0 93.0 82.5 77.5 68.0
590 450-1120 47.9 280 660 90 190 94.2 93.5 92.0 77.5 71.0 59.0
2965 400LL 45.4 320 148 110 220 94.8 94.4 93.2 91.5 89.0 84.0
1485 400LL 48.3 320 295 110 220 94.8 94.4 93.2 86.0 83.0 76.0
450 985 400LL 49.1 320 445 100 220 94.8 94.4 93.2 84.5 79.5 70.5
740 450-1120 50.2 320 592 90 190 94.5 94.0 93.0 83.0 78.0 69.0
590 450-1250 53.9 320 743 90 200 94.2 93.5 92.0 77.5 71.0 59.0
2965 400LL 50.3 350 164 110 210 95.0 94.5 93.5 91.5 89.0 84.0
1485 400LL 53.2 350 328 110 220 95.0 94.5 93.5 86.5 83.5 76.5
500 985 400-1250 55.8 350 494 90 200 94.5 94.0 93.0 83.0 78.0 69.0
740 450-1120 55.8 350 658 90 190 94.5 94.0 93.0 83.0 78.0 69.0
590 500-1120 59.8 350 825 90 190 94.4 93.8 92.2 77.5 71.0 60.0
2960 400-1120 57.4 400 184 100 200 94.8 94.4 93.2 90.0 87.5 82.0
1485 400LL 58.9 400 367 110 220 95.0 94.5 93.5 87.5 84.5 77.5
560 985 400-1250 63.6 400 554 90 200 94.5 94.0 93.0 81.5 77.0 68.0
740 450-1250 62.5 400 737 90 200 94.5 94.0 93.0 83.0 78.0 69.0
590 500-1250 68.7 400 924 100 200 94.5 94.0 93.0 75.5 69.0 58.0
2960 400-1120 64.6 450 207 100 200 94.8 94.4 93.2 90.0 87.5 82.0
1485 450-1120 65.2 450 413 100 210 95.0 94.5 93.5 89.0 86.0 80.0
630 985 450-1250 67.9 450 623 100 210 95.0 94.5 93.5 85.5 81.5 72.5
740 500-1120 70.5 450 829 100 200 94.8 94.4 93.2 82.5 77.5 68.5
592 560-1250 75.3 450 1037 85 190 94.5 94.0 93.0 77.5 71.0 60.0
2965 450-1120 72.6 505 233 110 190 95.0 94.5 93.5 90.0 87.5 82.0
1485 450-1120 73.3 505 466 100 210 95.2 94.8 93.8 89.0 86.0 80.0
710 985 450-1250 76.0 505 702 100 210 95.0 94.5 93.5 86.0 82.0 73.0
740 500-1120 79.2 505 935 100 200 95.0 94.5 93.5 82.5 77.5 68.5
592 560-1250 84.3 505 1168 85 190 94.5 94.0 93.0 78.0 71.5 60.5
2965 450-1120 76.2 530 246 110 190 95.2 94.8 93.8 90.5 88.0 83.0
1485 450-1250 77.4 530 492 100 210 95.2 94.8 93.8 89.0 86.0 80.0
750 985 500-1120 79.2 530 742 90 210 95.2 94.8 93.8 87.0 83.0 74.5
740 500-1250 84.7 530 987 100 210 95.0 94.5 93.5 81.5 76.5 67.5
592 560-1400 90.5 530 1234 90 200 94.8 94.2 93.2 76.5 70.0 59.0
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

56
HIGH VOLTAGE MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 50Hz , 6600V , S.F. 1.15
Class F Insulation , 40℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
2965 450-1120 81.7 570 263 100 190 95.2 94.8 93.8 90.0 87.5 82.0
1485 450-1250 82.6 570 525 100 210 95.2 94.8 93.8 89.0 86.0 80.0
800 985 500-1120 84.0 570 791 90 210 95.2 94.8 93.8 87.5 83.5 75.0
740 500-1250 89.8 570 1053 100 200 95.0 94.5 93.5 82.0 77.0 68.0
592 560-1400 96.5 570 1316 90 200 94.8 94.2 93.2 76.5 70.0 59.0
2965 450-1250 91.9 640 296 100 190 95.2 94.8 93.8 90.0 87.5 82.0
1485 450-1250 94.0 640 590 110 220 95.2 94.8 93.8 88.0 85.5 79.5
900 985 500-1250 95.6 640 890 90 200 95.2 94.8 93.8 86.5 82.5 74.0
740 560-1250 99.6 640 1185 100 200 95.2 94.8 93.8 83.0 78.0 69.0
592 630-1250 102 640 1481 90 200 95.0 94.5 93.5 81.0 75.0 65.0
2965 450-1250 102 710 328 110 210 95.2 94.8 93.8 90.5 88.0 83.0
1485 500-1250 102 710 656 80 210 95.5 95.0 94.0 90.0 87.0 82.0
1000 985 500-1250 106 710 989 90 210 95.5 95.0 94.0 86.5 82.5 74.0
740 560-1250 111 710 1316 100 210 95.2 94.8 93.8 82.5 77.5 68.5
592 630-1250 113 710 1645 85 190 95.0 94.5 93.5 81.5 75.5 65.5
2970 450-1400 113 800 367 110 210 95.5 95.0 94.0 90.5 88.0 83.0
1485 500-1250 114 800 735 90 210 95.5 95.0 94.0 90.0 87.0 82.0
1120 985 500-1400 119 800 1107 90 200 95.5 95.0 94.0 86.5 82.5 74.0
740 560-1400 124 800 1474 100 200 95.5 95.0 94.0 83.0 78.0 69.0
592 630-1400 129 800 1843 90 200 95.2 94.8 93.8 80.0 74.0 64.0
2970 450-1400 127 890 410 110 200 95.5 95.0 94.0 90.5 88.0 83.0
1485 500-1400 127 890 820 90 210 95.5 95.0 94.0 90.0 87.0 82.0
1250 985 560-1250 134 890 1236 90 200 95.5 95.0 94.0 85.5 81.0 73.0
740 630-1250 138 890 1645 80 190 95.5 95.0 94.0 83.0 78.0 69.0
593 710-1250 141 890 2053 80 180 95.2 94.8 93.8 81.5 75.5 65.5
2970 500-1250 152 1060 492 110 200 95.5 95.0 94.0 90.5 88.0 83.0
1485 560-1250 153 1060 984 90 220 95.6 95.2 94.2 90.0 87.0 82.0
1500 985 560-1400 165 1060 1483 90 210 95.5 95.0 94.0 83.5 79.0 71.0
740 630-1400 165 1060 1974 80 180 95.5 95.0 94.0 83.5 78.5 70.0
593 710-1400 168 1060 2464 85 190 95.5 95.0 94.0 82.0 76.0 66.0
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.

ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

57
LOW VOLTAGE VERTICAL MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 60Hz , 460V , S.F. 1.15
Class F Insulation , 40℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUTPUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
200 710 355LS 343 2050 274 100 210 95.0 94.5 93.0 77.0 70.0 58.0
220 710 355LS 377 2250 302 100 210 95.0 94.5 93.0 77.0 70.0 58.0
885 355LS 395 2500 275 100 200 95.2 94.8 93.0 83.5 79.0 70.0
250
710 355LS 423 2500 343 90 200 95.0 94.5 93.0 78.0 71.0 60.0
885 N355LL 442 2800 308 110 210 95.2 94.8 93.0 83.5 79.0 70.0
280
710 N355LL 473 2800 384 100 210 95.2 94.8 93.0 78.0 71.0 60.0
3560 355LS 455 3150 86 100 210 95.5 95.0 93.5 91.0 89.5 85.0
1770 355LS 476 3150 173 100 210 95.5 95.0 93.5 87.0 83.0 74.0
315 1180 355LS 481 3150 260 100 210 95.5 95.0 93.5 86.0 82.0 73.0
885 400LS 484 3150 347 100 210 95.5 95.0 93.5 85.5 81.0 72.0
710 400LS 518 3150 432 100 210 95.5 95.0 93.5 80.0 73.0 62.0
3560 N355LL 513 3600 97 100 210 95.5 95.0 93.5 91.0 89.5 85.0
1775 355LS 529 3600 195 100 210 95.7 95.2 94.0 88.0 85.0 78.0
355 1180 355LS 543 3600 293 100 210 95.5 95.0 93.5 86.0 82.0 73.0
885 400LS 546 3600 391 100 210 95.5 95.0 93.5 85.5 81.0 72.0
710 400LS 583 3600 487 110 220 95.5 95.0 93.5 80.0 73.0 62.0
3560 N355LL 542 3800 103 100 210 95.5 95.0 93.5 91.0 89.5 85.0
1775 355LS 559 3800 206 100 200 95.7 95.2 94.0 88.0 85.0 78.0
375 1180 355LS 573 3800 310 100 200 95.5 95.0 93.5 86.0 82.0 73.0
885 450LS 576 3800 413 100 210 95.5 95.0 94.0 85.5 81.0 72.0
710 450LS 616 3800 514 110 220 95.5 95.0 93.5 80.0 73.0 62.0
3560 N355LL 578 4000 109 100 210 95.5 95.0 93.5 91.0 89.5 85.0
1775 355LS 596 4000 219 100 200 95.7 95.2 94.0 88.0 85.0 78.0
400 1180 N355LL 611 4000 330 100 210 95.5 95.0 93.5 86.0 82.0 73.0
885 450LS 615 4000 440 110 220 95.5 95.0 93.5 85.5 81.0 72.0
710 450LS 657 4000 549 110 220 95.5 95.0 93.5 80.0 73.0 62.0
1775 N355LL 671 4400 247 100 200 95.7 95.2 94.0 88.0 85.0 78.0
1180 400LS 679 4400 371 100 220 95.6 95.1 94.0 87.0 84.0 76.0
450
890 450LS 688 4400 492 100 210 95.5 95.0 93.5 86.0 83.0 75.0
710 450LS 739 4400 617 100 220 95.5 95.0 93.5 80.0 73.0 62.0
1780 400LS 728 4700 274 110 210 95.8 95.4 94.5 90.0 87.5 80.0
500 1180 400LS 741 4700 413 100 210 95.7 95.3 94.2 88.5 85.5 78.0
890 450LS 764 4700 547 100 210 95.5 95.0 93.5 86.0 83.0 75.0
1780 400LS 815 5200 306 110 210 95.8 95.4 94.5 90.0 87.5 80.0
560
1180 450LS 830 5200 462 100 210 95.7 95.3 94.2 88.5 85.5 78.0
1780 450LS 917 5900 345 110 210 95.8 95.4 94.5 90.0 87.5 80.0
630
1185 450LS 927 5900 518 100 200 95.8 95.4 94.5 89.0 86.0 80.0
710 1785 450LS 1045 6700 387 100 210 95.8 95.4 94.5 89.0 86.0 79.0
750 1785 450LS 1104 7100 409 100 210 95.8 95.4 94.5 89.0 86.0 79.0
800 1785 450LS 1178 7600 437 100 210 95.8 95.4 94.5 89.0 86.0 79.0
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.

ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

58
LOW VOLTAGE VERTICAL MOTOR
Totally Enclosed , Squirrel Cage
3 Phase , 50Hz , 415V , S.F. 1.15
Class F Insulation , 40 ℃ Ambient
PERFORMANCE DATA Continuous Duty
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
185 590 355LS 347 1900 305 110 220 95.0 94.5 93.5 78.0 72.5 61.5
735 355LS 357 2200 265 100 210 95.0 94.7 93.5 82.0 78.0 68.5
200
590 355LS 378 2200 330 110 220 95.0 94.5 93.5 77.5 72.0 61.0
735 355LS 393 2400 292 100 210 95.0 94.7 93.5 82.0 78.0 68.5
220
590 355LS 413 2400 363 110 220 95.0 94.5 93.5 78.0 72.5 61.5
735 N355LL 446 2750 331 100 210 95.0 94.7 93.5 82.0 78.0 68.5
250
590 N355LL 469 2750 413 110 220 95.0 94.5 93.5 78.0 72.5 61.5
2970 355LS 450 3200 92 120 210 95.6 95.8 95.1 90.5 89.4 85.0
1480 355LS 467 3050 184 110 220 95.6 95.1 94.2 87.2 83.4 74.1
280 980 355LS 484 3050 278 100 220 95.5 95.2 94.0 84.2 80.0 75.6
740 400LS 481 3050 369 100 200 95.2 95.0 94.2 85.0 81.0 71.0
590 400LS 515 3050 462 100 200 95.2 94.8 94.0 79.5 74.0 70.0
2970 N355LL 503 3600 103 120 210 95.7 95.9 95.2 91.0 90.0 85.2
1480 355LS 517 3400 207 120 220 95.8 95.5 94.5 88.5 84.5 75.5
315 980 355LS 545 3400 313 100 220 95.5 95.2 94.0 84.2 80.0 75.0
740 400LS 542 3400 415 100 200 95.2 95.0 94.2 85.0 81.0 71.0
590 400LS 583 3400 520 100 200 95.2 94.8 94.0 79.0 73.5 69.5
2970 N355LL 573 4000 116 130 220 95.6 95.8 95.1 90.2 89.2 84.8
1480 355LS 583 3800 234 110 210 95.8 95.5 94.5 88.5 84.5 75.5
355 980 N355LL 614 3800 353 100 220 95.5 95.2 94.0 84.2 80.0 75.0
740 450LS 605 3800 467 100 200 95.4 95.1 94.3 85.5 81.5 71.5
590 450LS 653 3800 586 100 200 95.2 95.0 94.0 79.5 74.0 70.0
2970 N355LL 605 4200 123 110 210 95.6 95.8 95.1 90.2 89.2 84.8
1480 N355LL 615 4000 247 110 210 95.8 95.5 94.5 88.5 84.5 75.5
375 985 400LS 649 4000 371 100 220 95.5 95.2 94.0 84.2 80.0 75.0
740 450LS 643 4000 494 100 200 95.4 95.1 94.3 85.0 81.0 71.0
590 450LS 696 4000 617 100 200 95.5 95.0 94.3 78.5 72.5 68.5
1480 N355LL 653 4250 263 100 200 95.8 95.5 94.5 89.0 85.0 76.0
985 400LS 691 4350 396 100 220 95.6 95.3 94.2 84.2 80.0 75.0
400
740 450LS 686 4250 526 100 200 95.4 95.1 94.3 85.0 81.0 71.0
592 450LS 742 4250 658 100 200 95.5 95.0 94.3 78.5 72.5 68.5
1480 400LS 725 4700 296 100 220 96.0 95.8 95.0 90.0 88.0 84.0
450 985 450LS 773 4800 445 100 220 95.6 95.3 94.2 85.0 81.0 76.5
740 450LS 772 4800 592 100 200 95.4 95.1 94.3 85.0 81.0 71.0
1480 400LS 805 5200 329 100 200 96.0 95.8 95.0 90.0 88.0 84.0
500
985 450LS 855 5300 494 100 210 95.7 95.4 94.5 85.0 81.0 76.5
1480 450LS 898 5800 369 100 210 96.0 95.8 95.0 90.5 88.5 85.0
560
985 450LS 958 5900 554 90 200 95.7 95.4 94.5 85.0 81.0 76.5
630 1480 450LS 1001 6200 415 100 200 96.2 96.0 95.2 91.0 89.0 86.0
Note: (1). Above data are average values for reference only.
(2). Performance tolerance is according to IEC 34-1.

ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

59
MEDIUM VOLTAGE VERTICAL MOTOR-TEFC
Totally Enclosed Fan-Cooled
IEC standard 3-phase 60Hz , 3300V
Class F Insulation , Continuous Duty
PERFORMANCE DATA 40℃ Ambient ,
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
3550 315LL 30.7 210 41.2 120 220 95.0 94.6 93.2 90.0 87.5 82.0
1775 315LL 33.1 210 82.3 110 210 95.0 94.5 93.0 83.5 80.5 72.5
150 1180 315LL 35.8 210 124 110 210 94.5 94.0 92.5 77.5 72.5 62.5
880 315LL 37.6 225 166 130 200 93.0 92.0 90.0 75.0 68.5 56.5
705 355LS 40.0 225 207 90 200 93.0 92.0 90.0 70.5 64.5 52.0
3550 315LL 37.9 265 50.8 120 220 95.0 94.6 93.2 90.0 87.5 82.0
1775 315LL 40.6 265 102 110 210 95.0 94.5 93.0 84.0 81.0 73.0
185 1180 315LL 43.7 265 153 110 210 95.0 94.5 93.0 78.0 73.0 63.0
885 355LS 44.8 275 204 90 210 94.5 94.0 92.5 76.5 71.0 61.0
705 355LS 48.8 275 256 90 200 93.5 92.5 90.5 71.0 65.0 55.0
3550 315LL 41.2 285 54.9 120 220 95.0 94.6 93.2 89.5 87.0 81.5
1775 315LL 43.8 285 110 110 210 95.0 94.5 93.0 84.0 81.0 73.0
200 1180 315LL 47.8 285 165 110 210 95.0 94.5 93.0 77.0 72.0 62.0
885 355LS 48.4 295 220 90 210 94.5 94.0 92.5 76.5 71.0 61.0
705 355LS 52.7 295 276 90 200 93.5 92.5 90.5 71.0 65.0 55.0
3550 315LL 44.9 310 60.4 120 220 95.2 94.8 93.5 90.0 87.5 82.0
1775 315LL 47.7 310 121 110 210 95.0 94.5 93.0 85.0 82.0 74.0
220 1180 355LS 51.6 310 182 100 210 95.0 94.5 93.0 78.5 73.5 63.5
885 355LS 53.2 320 242 90 210 94.5 94.0 92.5 76.5 71.0 61.0
708 400LS 56.5 320 303 90 200 94.0 93.5 92.0 72.5 66.5 57.0
3555 355LS 51.1 355 68.5 110 220 95.2 94.8 93.5 90.0 87.5 82.0
1780 355LS 53.4 355 137 120 210 95.2 94.7 93.2 86.0 83.0 75.0
250 1180 355LS 57.8 355 206 100 210 95.2 94.7 93.2 79.5 74.5 64.5
885 355LS 60.5 365 275 110 220 94.5 94.0 92.5 76.5 71.0 61.0
708 400LS 64.6 365 344 90 200 94.0 93.5 92.0 72.0 66.0 56.0
3555 355LS 56.9 400 76.7 110 210 95.2 94.8 93.5 90.5 88.0 82.5
1780 355LS 59.5 400 153 120 210 95.2 94.7 93.2 86.5 83.5 76.0
280 1180 355LS 65.1 400 231 100 210 95.2 94.7 93.2 79.0 74.0 64.0
885 355LS 66.1 400 308 100 210 95.0 94.5 93.0 78.0 72.0 62.0
708 450LS 71.2 400 385 90 200 94.2 93.8 92.5 73.0 67.0 57.0
3555 355LS 63.8 445 86 110 210 95.5 95.0 94.0 90.5 88.0 82.5
1780 355LS 66.8 445 172 120 210 95.4 94.9 93.5 86.5 83.5 76.0
315 1180 355LS 72.4 445 260 100 210 95.2 94.7 93.2 80.0 75.0 65.0
885 N355LL 74.4 445 347 100 210 95.0 94.5 93.0 78.0 72.0 62.0
708 450LS 79.3 445 433 90 210 94.5 94.0 92.5 73.5 67.5 58.0
3555 355LS 71.5 500 97 120 220 95.5 95.0 94.0 91.0 89.0 84.0
1780 355LS 74.8 500 194 110 210 95.4 94.9 93.5 87.0 84.0 77.0
355 1180 355LS 81.6 500 293 100 210 95.2 94.7 93.2 80.0 75.0 65.0
885 400LS 83.1 500 391 100 210 95.2 94.7 93.2 78.5 72.5 63.0
708 450LS 88.2 500 488 90 210 94.5 94.0 92.5 74.5 68.0 59.0
Note:1.The above data are average values for reference only.
2.Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

60
MEDIUM VOLTAGE VERTICAL MOTOR-TEFC
Totally Enclosed Fan-Cooled
IEC standard 3-phase 60Hz , 3300V
Class F Insulation , Continuous Duty
PERFORMANCE DATA 40℃ Ambient ,
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
RPM
KW
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
3555 N355LL 75.9 530 103 120 220 95.5 95.0 94.0 90.5 88.0 83.0
1780 355LS 79.0 530 205 100 210 95.5 95.0 93.8 87.0 84.0 77.0
375 1180 355LS 86.1 530 310 100 210 95.2 94.7 93.2 80.0 75.0 65.0
885 450LS 87.2 530 413 110 220 95.2 94.7 93.2 79.0 73.0 63.0
708 450LS 92.7 530 516 90 210 95.0 94.5 93.0 74.5 68.0 59.0
3555 N355LL 81.0 565 110 120 220 95.5 95.0 94.0 90.5 88.0 83.0
1780 N355LL 84.2 565 219 120 210 95.5 95.0 93.8 87.0 84.0 77.0
400 1180 N355LL 88.8 565 330 90 200 95.5 95.0 93.5 82.5 78.5 68.5
885 450LS 93.6 565 440 100 210 95.2 94.7 93.2 78.5 72.5 62.5
708 450LS 98.9 565 550 90 210 95.0 94.5 93.0 74.5 68.0 59.0
3555 N355LL 91.0 635 123 120 220 95.6 95.2 94.2 90.5 88.0 83.0
1780 N355LL 95.3 635 246 120 220 95.5 95.0 93.8 86.5 84.0 76.5
450 1180 N355LL 99.3 635 371 90 190 95.5 95.0 93.5 83.0 79.0 70.0
885 450LS 103 635 495 100 210 95.5 95.0 93.5 80.0 74.0 65.0
708 500-V 106 635 619 80 190 95.0 94.5 93.0 78.0 71.0 62.0
3555 N355LL 101 705 137 120 220 95.6 95.2 94.2 90.5 88.0 83.0
1780 N355LL 105 705 274 120 220 95.5 95.0 93.8 87.5 85.0 78.0
500 1180 450LS 108 690 413 100 210 95.5 95.0 93.5 85.0 81.0 74.0
885 450-V 115 690 550 90 190 95.0 94.5 93.0 80.0 74.0 65.0
708 500-V 118 690 688 80 200 95.0 94.5 93.0 78.0 71.0 62.0
3555 355-V 114 790 153 110 210 95.2 94.8 93.8 90.0 88.0 83.0
1780 N355LL 118 790 306 100 200 95.8 95.3 94.0 86.5 84.0 77.0
560 1180 450LS 121 755 462 100 210 95.5 95.0 93.5 85.0 81.0 74.0
885 450-V 129 755 616 90 190 95.0 94.5 93.0 80.0 74.0 65.0
708 500-V 132 755 770 90 190 95.0 94.5 93.0 78.0 71.0 62.0
3555 355-V 129 890 173 110 210 95.3 94.9 94.0 90.0 88.0 83.0
1780 400-V 132 890 345 90 200 95.2 94.8 93.8 88.0 85.5 80.0
630 1185 400-V 138 850 518 80 180 95.2 94.8 93.8 84.0 80.5 72.0
885 450-V 143 850 693 90 190 95.2 94.8 93.2 81.0 75.0 66.0
708 500-V 150 850 867 90 200 95.2 94.8 93.2 77.0 70.0 61.0
3560 400-V 143 980 194 110 210 95.5 95.0 94.0 91.0 88.5 84.0
1780 400-V 148 980 389 90 200 95.2 94.8 93.8 88.0 85.5 80.0
710 1185 400-V 157 940 584 90 190 95.5 95.0 94.0 83.0 80.0 71.5
885 450-V 163 940 781 90 190 95.2 94.8 93.2 80.0 74.0 65.0
708 500-V 169 940 977 90 200 95.2 94.8 93.2 77.0 70.0 61.0
3560 400-V 153 1000 205 100 200 95.5 95.0 94.0 90.0 87.5 82.5
1780 400-V 156 1000 410 90 200 95.5 95.0 94.0 88.0 85.5 78.0
750 1185 400-V 165 1000 616 90 190 95.5 95.0 94.0 83.5 80.5 72.0
890 500-V 172 1000 821 90 200 95.5 95.0 94.0 80.0 74.0 65.0
708 500-V 178 1000 1032 85 190 95.2 94.8 93.2 77.5 70.5 61.5
Note:1.The above data are average values for reference only.
2.Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

61
MEDIUM VOLTAGE VERTICAL MOTOR-TEFC
Totally Enclosed Fan-Cooled
IEC standard 3-phase 60Hz , 3300V
Class F Insulation , Continuous Duty
PERFORMANCE DATA 40℃ Ambient ,
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
RPM
KW
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
3560 400-V 162 1050 219 110 210 95.5 95.2 94.5 90.5 88.0 83.0
1780 400-V 167 1050 438 90 200 95.5 95.0 94.0 88.0 85.0 78.0
800 1185 450-V 170 1050 658 100 210 95.5 95.0 94.0 86.0 82.0 75.0
890 500-V 177 1050 876 90 190 95.5 95.0 94.0 83.0 78.0 70.0
710 500-V 188 1050 1097 80 190 95.5 95.0 94.0 78.0 71.0 62.0
3560 400-V 182 1180 246 110 210 95.5 95.2 94.5 90.5 88.0 83.0
1780 400-V 187 1180 492 90 200 95.5 95.0 94.0 88.0 85.0 78.0
900 1185 450-V 190 1180 740 100 210 95.5 95.2 94.5 87.0 83.0 76.0
890 500-V 204 1220 985 100 200 95.5 95.0 94.0 81.0 75.5 68.5
710 560-V 213 1220 1235 90 200 95.5 95.0 94.0 77.5 70.5 61.5
3560 450-V 201 1300 274 100 190 95.5 95.2 94.5 91.0 88.5 83.5
1785 450-V 206 1300 546 90 200 95.5 95.2 94.5 89.0 86.0 80.0
1000 1185 450-V 214 1300 822 100 220 95.5 95.2 94.5 85.5 81.5 74.5
890 500-V 222 1300 1094 100 200 95.5 95.0 94.0 82.5 77.0 70.0
710 560-V 236 1300 1372 90 200 95.5 95.0 94.0 77.5 70.5 68.5
3560 450-V 225 1460 306 100 200 95.5 95.2 94.5 91.0 88.5 83.5
1785 450-V 229 1460 611 90 200 95.5 95.2 94.5 89.5 86.5 80.0
1120 1185 500-V 235 1460 921 90 190 95.5 95.2 94.5 87.5 84.5 78.0
890 560-V 247 1460 1226 100 200 95.5 95.0 94.0 83.0 77.5 71.0
710 630-V 250 1460 1536 90 190 95.5 95.0 94.0 82.0 76.0 70.0
3560 500-V 251 1620 342 110 210 95.6 95.3 94.6 91.0 89.0 84.0
1785 500-V 259 1620 682 90 200 95.5 95.2 94.5 88.5 85.5 79.0
1250 1185 500-V 262 1620 1027 90 190 95.5 95.2 94.5 87.5 83.5 76.5
885 560-V 276 1620 1376 90 200 95.5 95.2 94.5 83.0 77.5 71.0
710 630-V 283 1620 1715 100 200 95.5 95.2 94.5 81.0 75.0 69.0
3560 500-V 302 1950 410 110 210 95.6 95.3 94.6 91.0 89.0 84.0
1785 500-V 309 1950 818 90 200 95.5 95.2 94.5 89.0 86.0 79.5
1500 1185 500-V 316 1950 1233 100 200 95.5 95.2 94.5 87.0 83.0 76.0
885 560-V 327 1950 1651 90 190 95.5 95.2 94.5 84.0 78.5 72.5
710 630-V 339 1950 2058 100 200 95.5 95.2 94.5 81.0 75.0 69.0
Note:1.The above data are average values for reference only.
2.Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

62
MEDIUM VOLTAGE VERTICAL MOTOR-TEFC
Totally Enclosed Fan-Cooled
IEC standard 3-phase 50Hz , 3300V
Class F Insulation , Continuous Duty
PERFORMANCE DATA 40℃ Ambient ,
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
2955 315LL 31.1 215 49.4 120 230 94.8 94.4 93.0 89.0 86.5 81.0
1480 315LL 33.4 215 98.7 110 210 94.8 94.4 93.0 83.0 80.0 72.0
150 980 315LL 36.5 215 149 110 210 94.5 94.0 92.5 76.0 71.0 62.0
735 355LS 37.6 215 199 100 210 93.8 93.0 91.0 74.5 68.0 56.0
585 355LS 40.1 215 250 100 200 93.5 92.5 90.5 70.0 64.0 52.0
2955 315LL 37.9 265 61.0 110 220 95.0 94.6 93.2 90.0 87.2 82.0
1480 315LL 40.6 265 122 100 200 95.0 94.6 93.2 84.0 81.0 73.0
185 980 315LL 45.7 265 184 110 210 94.5 94.0 92.5 75.0 70.0 61.0
735 355LS 46.2 265 245 100 210 94.0 93.5 91.5 74.5 68.5 58.5
585 400LS 47.2 265 308 80 200 94.0 93.0 91.0 73.0 68.0 56.0
2955 315LL 40.9 285 65.9 120 230 95.0 94.6 93.2 90.0 87.2 82.0
1480 355LS 44.1 285 132 120 230 95.0 94.6 93.2 83.5 80.5 72.5
200 980 355LS 46.2 285 199 100 210 94.6 94.1 92.8 80.0 75.0 66.0
735 355LS 49.2 285 265 100 210 94.2 93.8 91.8 75.5 69.5 59.5
585 400LS 51.0 285 333 90 200 94.0 93.0 91.0 73.0 68.0 56.0
2955 355LS 44.9 310 72.5 110 210 95.2 94.8 93.5 90.0 87.5 82.0
1480 355LS 47.9 310 145 110 210 95.0 94.6 93.2 84.5 81.5 73.5
220 980 355LS 50.5 310 219 100 210 94.6 94.1 92.8 80.5 75.5 66.5
735 355LS 53.4 310 292 100 210 94.3 93.9 91.9 76.5 70.0 60.0
585 400LS 56.0 310 366 90 210 94.2 93.5 91.5 73.0 68.0 56.0
2955 355LS 50.8 355 82.4 110 210 95.2 94.8 93.5 90.5 88.0 83.0
1480 355LS 53.7 355 165 110 210 95.2 94.8 93.5 85.5 82.5 75.0
250 980 355LS 56.6 355 248 90 200 94.8 94.4 93.0 81.5 76.5 67.5
735 355LS 61.0 355 331 100 210 94.3 93.9 91.9 76.0 69.5 59.5
585 450LS 63.6 355 416 90 210 94.2 93.5 91.5 73.0 68.0 56.0
2955 355LS 56.9 400 92.3 110 220 95.2 94.8 93.5 90.5 88.0 83.0
1480 355LS 59.8 400 184 110 210 95.2 94.8 93.5 86.0 83.0 76.0
280 980 355LS 63.3 400 278 90 200 95.0 94.5 93.2 81.5 76.5 67.5
735 N355LL 70.1 400 371 100 210 94.5 94.0 92.0 74.0 68.0 58.0
585 450LS 69.1 400 466 90 210 94.5 94.0 92.0 75.0 70.0 60.0
2955 N355LL 63.4 445 104 120 230 95.5 95.0 93.8 91.0 88.5 83.5
1480 355LS 67.3 445 207 110 210 95.2 94.8 93.5 86.0 83.0 76.0
315 980 355LS 70.7 445 313 90 200 95.0 94.5 93.2 82.0 77.0 68.0
735 400LS 74.4 445 417 90 210 95.0 94.5 93.0 78.0 73.0 65.0
585 450LS 77.8 445 524 90 210 94.5 93.5 92.0 75.0 70.0 60.0
2955 N355LL 71.5 500 117 120 230 95.5 95.0 93.8 91.0 88.5 83.5
1480 N355LL 76.1 500 234 120 230 95.5 95.0 93.8 85.5 82.5 75.0
355 980 N355LL 80.1 500 353 90 200 95.2 94.8 93.5 81.5 77.0 68.0
735 450LS 83.8 500 470 90 210 95.0 94.5 93.0 78.0 73.0 65.0
585 450LS 87.6 500 591 90 210 94.5 93.5 92.0 75.0 70.0 60.0
Note:1.The above data are average values for reference only.
2.Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

63
MEDIUM VOLTAGE VERTICAL MOTOR-TEFC
Totally Enclosed Fan-Cooled
IEC standard 3-phase 50Hz , 3300V
Class F Insulation , Continuous Duty
PERFORMANCE DATA 40℃ Ambient ,
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
RPM
KW
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
2955 N355LL 75.5 530 124 120 230 95.5 95.0 94.0 91.0 88.5 83.5
1480 N355LL 80.4 530 247 100 210 95.5 95.0 94.0 85.5 82.5 75.0
375 980 N355LL 84.6 530 373 90 200 95.2 94.8 93.5 81.5 77.0 68.0
735 450LS 88.5 530 497 90 210 95.0 94.5 93.0 78.0 73.0 65.0
590 450-V 90.2 530 619 90 210 94.5 93.5 92.0 77.0 72.0 62.0
2955 N355LL 80.5 565 132 120 230 95.5 95.0 94.0 91.0 88.5 83.5
1480 N355LL 84.7 565 263 100 210 95.5 95.0 94.0 86.5 83.5 77.0
400 980 N355LL 91.9 565 398 90 200 95.2 94.8 93.5 80.0 75.5 66.5
735 450LS 93.1 565 530 90 210 95.2 94.8 93.5 79.0 74.0 66.0
590 450-V 96.2 565 660 90 200 94.5 93.5 92.0 77.0 72.0 62.0
2955 N355LL 90.6 635 148 110 220 95.5 95.0 94.0 91.0 88.5 83.5
1480 N355LL 94.8 635 296 100 200 95.5 95.0 94.0 87.0 84.0 79.0
450 985 450LS 97.0 635 445 100 220 95.5 95.0 94.0 85.0 81.5 75.0
735 450LS 101 635 596 90 210 95.2 94.8 93.5 82.0 77.0 70.0
590 450-V 107 635 743 90 200 94.5 93.5 92.0 78.0 73.0 63.0
2955 355-V 102 705 165 110 210 95.2 94.8 93.5 90.0 87.5 82.5
1480 N355LL 106 705 329 110 190 95.5 95.0 94.0 86.5 83.5 78.0
500 985 450LS 108 705 494 100 220 95.5 95.0 94.0 85.0 81.5 75.0
735 450-V 113 705 663 90 190 95.0 94.5 93.2 81.5 76.0 69.0
590 500-V 119 705 825 90 200 94.5 93.5 92.0 78.0 73.0 63.0
2955 355-V 114 790 185 100 200 95.2 94.8 93.5 90.0 87.5 82.5
1480 400-V 120 790 369 90 210 95.2 94.8 93.5 86.0 82.5 75.5
560 980 400-V 124 790 557 80 200 95.0 94.5 93.2 83.0 79.5 72.5
735 450-V 126 790 742 90 190 95.0 94.5 93.2 82.0 77.0 70.0
590 500-V 131 790 924 100 210 94.8 94.2 93.0 79.0 74.0 64.0
2955 400-V 127 890 208 100 200 95.5 95.0 94.0 91.0 88.5 83.5
1480 400-V 134 890 415 90 210 95.2 94.8 93.5 86.5 83.0 76.0
630 980 400-V 142 890 626 80 200 95.0 94.5 93.2 81.5 77.0 70.0
735 450-V 141 890 835 90 190 95.0 94.5 93.2 82.0 77.0 70.0
590 500-V 147 890 1040 100 200 94.8 94.2 93.0 79.0 74.0 64.0
2955 400-V 143 1010 234 100 200 95.5 95.0 94.0 91.0 88.5 83.5
1480 400-V 151 1010 467 90 210 95.2 94.8 94.0 86.5 83.0 76.0
710 980 450-V 154 1010 706 90 210 95.2 94.8 94.0 85.0 81.5 74.0
735 500-V 163 1010 941 100 200 95.2 94.8 94.0 80.0 75.0 68.0
590 500-V 170 1010 1172 100 200 94.8 94.2 93.0 77.0 72.0 62.0
2955 400-V 151 1065 247 100 200 95.5 95.0 94.0 91.0 88.5 83.5
1480 400-V 159 1065 494 90 210 95.2 94.8 94.0 86.5 83.0 76.0
750 980 450-V 162 1065 745 90 200 95.2 94.8 94.0 85.0 81.5 74.0
735 500-V 171 1065 994 90 190 95.2 94.8 94.0 80.5 75.5 68.5
590 560-V 175 1065 1238 100 210 95.0 94.5 93.2 79.0 74.0 64.0
Note:1.The above data are average values for reference only.
2.Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

64
MEDIUM VOLTAGE VERTICAL MOTOR-TEFC
Totally Enclosed Fan-Cooled
IEC standard 3-phase 50Hz , 3300V
Class F Insulation , Continuous Duty
PERFORMANCE DATA 40℃ Ambient ,
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
RPM
KW
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
2955 400-V 161 1140 264 100 200 95.5 95.0 94.0 91.0 88.5 83.5
1480 400-V 170 1140 526 90 210 95.2 94.8 94.0 86.5 83.0 76.0
800 980 450-V 171 1140 795 85 190 95.2 94.8 94.0 86.0 82.0 75.0
735 500-V 180 1140 1060 100 200 95.2 94.8 94.0 81.5 76.5 70.5
590 560-V 184 1140 1321 100 210 95.0 94.5 93.2 80.0 75.0 66.0
2955 450-V 181 1280 297 110 200 95.6 95.2 94.2 91.0 88.5 83.5
1485 450-V 186 1280 590 90 200 95.5 95.2 94.5 88.5 85.5 79.0
900 985 500-V 194 1280 890 90 200 95.5 95.0 94.5 85.0 81.0 74.0
735 500-V 204 1280 1193 100 200 95.2 94.8 94.0 81.0 76.0 70.0
590 560-V 207 1280 1486 100 210 95.0 94.5 93.2 80.0 75.0 66.0
2955 450-V 202 1425 330 110 200 95.6 95.2 94.2 90.5 88.0 83.0
1485 450-V 207 1425 656 90 200 95.5 95.2 94.5 88.5 85.5 79.0
1000 985 500-V 212 1425 989 85 190 95.5 95.2 94.5 86.5 82.5 76.0
740 560-V 226 1425 1316 90 200 95.5 95.2 94.0 81.0 76.0 70.0
590 630-V 230 1425 1651 90 190 95.2 94.8 93.5 80.0 75.0 68.0
2960 500-V 224 1595 369 110 210 95.8 95.4 94.4 91.5 89.0 84.0
1485 500-V 230 1595 735 90 210 95.6 95.2 94.5 89.0 86.0 80.0
1120 985 500-V 236 1595 1107 85 190 95.5 95.2 94.5 87.0 83.0 76.5
740 560-V 253 1595 1474 90 200 95.5 95.2 94.0 81.0 76.0 70.0
590 630-V 257 1595 1849 90 200 95.2 94.8 93.5 80.0 75.0 68.0
2960 500-V 249 1780 411 110 210 95.8 95.4 94.4 91.5 89.0 84.0
1485 500-V 257 1780 820 90 210 95.6 95.2 94.5 89.0 86.0 80.0
1250 985 500-V 262 1780 1236 85 190 95.5 95.2 94.5 87.5 83.5 77.0
740 560-V 283 1780 1645 90 200 95.5 95.0 94.0 81.0 76.0 70.0
590 630-V 286 1780 2064 100 210 95.5 95.0 94.0 80.0 75.0 68.0
2960 500-V 299 2135 494 110 210 95.8 95.4 94.4 91.5 89.0 84.0
1485 500-V 308 2135 984 90 210 95.6 95.2 94.5 89.0 86.0 80.0
1500 985 560-V 314 2135 1483 90 200 95.6 95.2 94.5 87.5 83.5 77.0
740 630-V 339 2135 1974 90 210 95.5 95.0 94.0 81.0 76.0 70.0
590 710-V 341 2135 2476 90 200 95.5 95.0 94.0 80.5 75.5 68.5
Note:1.The above data are average values for reference only.
2.Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

65
HIGH VOLTAGE VERTICAL MOTOR-TEFC
Totally Enclosed Fan-Cooled
IEC standard 3-phase 60Hz , 6600V
Class F Insulation , Continuous Duty
PERFORMANCE DATA 40℃ Ambient ,
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
3550 355LS 15.5 110 41.2 110 230 93.8 93.2 91.8 90.0 87.5 82.0
1775 355LS 16.8 110 82.3 100 210 93.8 93.2 91.8 83.5 80.5 72.5
150 1180 355LS 18.5 110 124 100 210 93.5 93.0 91.5 76.0 71.0 61.0
880 355LS 19.1 110 166 100 220 93.0 92.0 90.0 74.0 68.0 54.0
705 N355LL 21.0 110 207 100 220 92.5 91.5 89.0 67.5 60.0 47.0
3550 355LS 19.2 135 50.8 110 230 93.8 93.2 91.8 90.0 87.5 82.0
1775 355LS 20.5 135 102 100 210 93.8 93.2 91.8 84.0 81.0 73.0
185 1180 355LS 22.0 135 153 100 210 93.5 93.0 91.5 78.5 73.5 63.5
880 355LS 23.5 135 205 100 220 93.2 92.2 90.0 74.0 68.0 54.0
705 400LS 24.9 135 256 100 220 93.0 92.0 89.5 70.0 63.0 50.0
3550 355LS 20.7 145 54.9 110 230 93.8 93.2 91.8 90.0 87.5 82.0
1775 355LS 22.1 145 110 100 210 93.8 93.2 91.8 84.5 81.5 73.5
200 1180 355LS 24.1 145 165 100 210 93.5 93.0 91.5 77.5 72.5 62.5
880 N355LL 25.4 145 221 100 230 93.2 92.2 90.0 74.0 68.0 54.0
705 400LS 26.9 145 276 100 230 93.0 92.0 89.5 70.0 63.0 50.0
3550 355LS 22.8 160 60.4 110 230 93.8 93.2 91.8 90.0 87.5 82.0
1775 355LS 24.4 160 121 110 220 94.0 93.5 92.0 84.0 81.0 73.0
220 1180 355LS 27.0 160 182 100 210 93.8 93.2 91.8 76.0 71.0 61.0
880 N355LL 27.4 160 244 100 230 93.5 93.0 91.5 75.0 70.0 57.0
705 450LS 29.1 160 304 90 230 93.2 92.2 90.0 71.0 64.0 51.0
3550 N355LL 25.9 180 68.6 120 230 94.0 93.5 92.0 90.0 87.5 82.0
1775 355LS 27.2 180 137 100 210 94.0 93.5 92.0 85.5 82.5 74.5
250 1180 355LS 30.7 180 206 100 210 93.8 93.2 91.8 76.0 71.0 61.0
880 N355LL 30.8 180 277 100 220 93.5 93.0 91.5 76.0 71.0 58.0
705 450LS 32.9 180 345 90 230 93.5 92.5 91.0 71.0 64.0 51.0
3550 N355LL 28.9 205 76.8 120 230 94.2 93.7 92.2 90.0 87.5 82.0
1775 355LS 30.2 205 154 100 210 94.2 93.7 92.2 86.0 83.0 75.0
280 1180 N355LL 33.6 205 231 90 220 94.0 93.5 92.0 77.5 72.5 62.5
885 400LS 33.8 205 308 90 220 94.0 93.5 92.0 77.0 72.0 62.0
710 450LS 36.4 205 384 90 230 93.5 92.5 91.0 72.0 65.0 53.0
3550 N355LL 32.5 225 86.4 120 230 94.2 93.7 92.2 90.0 87.5 82.0
1780 N355LL 34.1 225 172 110 220 94.5 94.0 92.5 85.5 82.5 74.5
315 1180 N355LL 36.8 225 260 90 220 94.2 93.7 92.2 79.5 74.5 65.0
885 450LS 37.0 225 347 90 210 94.2 93.7 92.2 79.0 74.0 64.0
710 450LS 40.1 225 432 90 230 94.2 93.7 92.2 73.0 66.0 55.0
3550 N355LL 36.3 255 97.4 120 230 94.5 94.0 92.5 90.5 88.0 83.0
1780 N355LL 38.0 255 194 100 210 94.5 94.0 92.5 86.5 83.5 76.0
355 1180 N355LL 41.1 255 293 90 220 94.5 94.0 92.5 80.0 75.0 66.0
885 450LS 41.6 255 391 90 220 94.5 94.0 92.5 79.0 74.0 64.0
710 450-V 43.4 255 487 90 210 94.2 93.8 92.0 76.0 70.0 58.0
Note:1.The above data are average values for reference only.
2.Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

66
HIGH VOLTAGE VERTICAL MOTOR-TEFC
Totally Enclosed Fan-Cooled
IEC standard 3-phase 60Hz , 6600V
Class F Insulation , Continuous Duty
PERFORMANCE DATA 40℃ Ambient ,
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
RPM
KW
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
3550 N355LL 38.4 265 103 120 230 94.5 94.0 92.5 90.5 88.0 83.0
1780 N355LL 40.4 265 205 100 210 94.5 94.0 92.5 86.0 83.5 76.0
375 1185 450LS 40.8 265 308 90 220 94.5 94.0 92.5 85.0 81.0 74.0
885 450LS 43.4 265 413 90 220 94.5 94.0 92.5 80.0 75.0 65.0
710 450-V 45.5 265 514 90 210 94.2 93.8 92.0 76.5 70.5 58.5
3550 N355LL 40.9 285 110 120 220 94.5 94.0 92.5 90.5 88.0 83.0
1780 N355LL 42.6 285 219 100 210 94.5 94.0 92.5 87.0 84.0 76.5
400 1185 450LS 43.8 285 329 90 220 94.5 94.0 92.5 84.5 80.5 73.0
885 450LS 45.7 285 440 90 220 94.5 94.0 92.5 81.0 76.0 66.0
710 450-V 48.2 285 549 90 210 94.2 93.8 92.0 77.0 71.0 59.0
3550 355-V 46.3 320 123 100 200 94.5 94.0 92.5 90.0 87.5 82.0
1780 N355LL 47.6 320 246 100 200 94.5 94.0 92.5 87.5 84.5 77.0
450 1185 450LS 48.7 320 370 90 220 94.5 94.0 92.5 85.5 81.5 74.5
885 450-V 50.2 320 495 85 200 94.5 94.0 92.5 83.0 78.0 68.0
710 450-V 53.6 300 617 90 210 94.2 93.8 92.0 78.0 72.0 60.0
3550 355-V 51.4 350 137 100 200 94.5 94.0 92.5 90.0 87.5 82.0
1780 400-V 53.0 350 274 100 210 94.8 94.3 93.0 87.0 84.0 76.0
500 1185 450LS 54.3 350 411 90 220 94.8 94.3 93.0 85.0 81.0 74.0
885 450-V 55.8 320 550 85 200 94.5 94.0 92.5 83.0 78.0 68.0
710 500-V 59.3 320 686 90 210 94.5 94.0 92.5 78.0 72.0 60.0
3555 400-V 57.4 390 153 100 210 94.8 94.3 93.0 90.0 87.5 82.0
1780 400-V 59.1 390 306 100 210 94.8 94.3 93.0 87.5 84.5 77.0
560 1180 400-V 62.1 370 462 90 200 94.5 94.0 92.5 83.5 79.0 72.0
885 450-V 62.5 370 616 85 190 94.5 94.0 92.5 83.0 78.0 68.0
710 500-V 66.5 370 768 90 210 94.5 94.0 92.5 78.0 72.0 60.0
3555 400-V 64.2 420 173 100 200 94.8 94.3 93.0 90.5 88.0 83.0
1780 400-V 66.8 420 345 100 210 94.8 94.3 93.0 87.0 84.0 76.0
630 1180 400-V 69.0 420 520 90 200 94.5 94.0 92.5 84.5 80.0 73.0
885 500-V 69.6 420 693 85 190 94.8 94.5 93.0 83.5 78.5 68.5
710 500-V 74.8 420 864 90 210 94.5 94.0 92.5 78.0 72.0 60.0
3555 400-V 72.4 480 195 100 200 94.8 94.3 93.0 90.5 88.0 83.0
1785 450-V 73.6 480 387 100 220 94.8 94.5 93.0 89.0 86.0 79.0
710 1185 450-V 76.6 480 584 90 210 94.8 94.5 93.0 85.5 81.0 74.0
885 500-V 78.9 480 781 90 200 94.8 94.5 93.0 83.0 78.0 68.0
710 560-V 83.2 480 974 90 210 94.5 94.0 92.5 79.0 73.0 62.0
3555 400-V 76.5 500 205 100 200 94.8 94.3 93.0 90.5 88.0 83.0
1785 450-V 77.8 500 409 100 210 94.8 94.5 93.0 89.0 86.0 79.0
750 1185 450-V 80.5 500 616 90 210 94.8 94.5 93.0 86.0 81.5 74.5
885 500-V 83.4 500 825 90 200 94.8 94.5 93.0 83.0 78.0 68.0
710 560-V 87.6 500 1029 90 210 94.8 94.5 93.0 79.0 73.0 62.0
Note:1.The above data are average values for reference only.
2.Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

67
HIGH VOLTAGE VERTICAL MOTOR-TEFC
Totally Enclosed Fan-Cooled
IEC standard 3-phase 60Hz , 6600V
Class F Insulation , Continuous Duty
PERFORMANCE DATA 40℃ Ambient ,
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
RPM
KW
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
3555 450-V 81.4 530 219 100 200 95.0 94.5 93.0 90.5 88.0 83.0
1785 500-V 83.7 530 437 90 200 95.0 94.5 93.0 88.0 85.0 78.0
800 1185 500-V 85.7 530 658 90 220 95.0 94.5 93.0 86.0 81.5 74.5
885 500-V 88.8 530 880 90 200 95.0 94.5 93.0 83.0 78.0 68.0
710 560-V 93.4 530 1097 90 210 94.8 94.5 93.0 79.0 73.0 62.0
3555 450-V 91.6 600 247 100 200 95.0 94.5 93.0 90.5 88.0 83.0
1785 500-V 93.1 600 491 90 200 95.0 94.5 93.0 89.0 86.0 79.0
900 1185 500-V 98.1 600 740 90 220 95.0 94.5 93.0 84.5 80.0 73.0
885 500-V 100 600 991 100 220 95.0 94.5 93.0 82.5 77.0 66.5
710 630-V 101 600 1235 90 190 94.8 94.5 93.0 82.0 76.0 65.0
3555 500-V 102 660 274 110 210 95.0 94.5 93.0 90.5 88.0 83.0
1785 500-V 103 660 546 90 200 95.0 94.5 93.0 89.0 86.0 79.0
1000 1185 500-V 108 660 822 90 220 95.0 94.5 93.0 85.0 80.5 73.5
890 560-V 112 660 1094 100 220 95.0 94.5 93.0 82.5 77.0 66.5
710 630-V 114 660 1372 100 220 95.0 94.5 93.0 81.0 75.0 64.0
3555 500-V 114 740 307 110 210 95.0 94.5 93.0 90.5 88.0 83.0
1785 500-V 116 740 611 90 200 95.2 94.8 93.5 88.5 85.5 78.5
1120 1185 500-V 122 740 921 90 220 95.2 94.8 93.5 84.5 80.0 73.0
890 560-V 124 740 1226 90 210 95.2 94.8 93.5 83.0 78.0 68.0
710 630-V 126 740 1536 100 220 95.0 94.5 93.0 82.0 77.0 66.0
3555 500-V 126 820 342 100 200 95.2 94.8 93.5 91.0 88.5 84.0
1785 500-V 130 820 682 90 200 95.2 94.8 93.5 88.5 85.5 78.5
1250 1185 560-V 137 820 1027 90 210 95.2 94.8 93.5 84.0 80.0 73.0
890 630-V 138 820 1368 90 200 95.2 94.8 93.5 83.0 78.0 68.0
710 630-V 140 820 1715 90 200 95.0 94.5 93.0 82.0 77.0 66.0
3555 500-V 151 980 411 100 200 95.2 94.8 93.5 91.0 88.5 84.0
1785 560-V 153 980 818 90 220 95.5 95.0 93.8 90.0 87.0 80.0
1500 1185 560-V 159 980 1233 80 200 95.2 94.8 93.5 86.5 81.5 74.0
890 630-V 166 980 1642 85 200 95.2 94.8 93.5 83.0 78.0 68.0
710 710-V 166 980 2058 90 200 95.2 94.8 93.5 83.0 77.5 68.0
Note:1.The above data are average values for reference only.
2.Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

68
HIGH VOLTAGE VERTICAL MOTOR-TEFC
Totally Enclosed Fan-Cooled
IEC standard 3-phase 50Hz , 6600V
Class F Insulation , Continuous Duty
PERFORMANCE DATA 40℃ Ambient ,
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
KW RPM
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
2960 355LS 16.0 110 49.4 110 230 93.5 93.0 91.5 87.5 85.0 80.0
1480 355LS 17.1 110 98.7 120 220 93.5 93.0 91.5 82.0 79.0 72.0
150 985 355LS 17.9 110 148 110 220 93.2 92.5 91.0 78.5 73.5 63.5
735 N355LL 19.6 120 199 120 240 93.0 92.0 90.0 72.0 66.0 54.5
588 400LS 19.6 120 248 90 220 93.0 92.0 90.0 72.0 65.5 53.2
2960 355LS 19.2 135 60.9 110 230 94.0 93.5 92.0 89.5 87.0 82.0
1480 355LS 20.5 135 122 110 210 94.0 93.5 92.0 84.0 81.0 74.0
185 985 355LS 21.4 135 183 100 200 93.5 93.0 91.5 81.0 76.0 66.0
735 N355LL 23.5 140 245 120 230 93.2 92.2 90.5 74.0 68.0 57.0
588 450LS 24.2 140 306 90 200 93.0 92.0 90.0 72.0 65.5 53.0
2960 355LS 20.7 145 65.8 100 220 94.0 93.5 92.0 90.0 87.5 82.5
1480 355LS 22.3 145 132 110 210 94.0 93.5 92.0 83.5 80.5 73.5
200 985 355LS 23.4 145 198 100 210 93.6 93.1 91.6 80.0 75.0 65.0
735 N355LL 24.9 150 265 120 230 93.5 92.5 91.0 75.0 69.0 58.0
588 450LS 26.1 150 331 90 210 93.2 92.2 90.5 72.0 65.5 53.0
2960 355LS 22.7 160 72.4 110 230 94.2 93.7 92.2 90.0 87.5 82.5
1480 355LS 24.3 160 145 110 210 94.2 93.7 92.2 84.0 81.0 74.0
220 985 355LS 25.6 160 218 100 210 93.8 93.3 91.9 80.0 75.0 65.0
735 N355LL 27.4 170 292 120 230 93.5 92.5 91.0 75.0 69.0 58.0
588 450LS 28.6 170 364 90 220 93.5 92.5 91.0 72.0 65.5 53.0
2965 N355LL 25.8 180 82.1 130 230 94.2 93.7 92.2 90.0 87.5 82.5
1480 355LS 27.8 180 165 120 220 94.2 93.7 92.2 83.5 80.5 73.5
250 985 N355LL 29.1 180 247 100 210 94.0 93.5 92.0 80.0 75.0 65.0
735 400LS 29.8 180 331 90 220 94.0 93.5 92.0 78.0 72.0 61.0
588 450LS 32.3 180 414 85 210 93.5 92.5 91.0 72.5 66.0 53.5
2965 N355LL 28.9 200 92.0 130 230 94.2 93.7 92.2 90.0 87.5 82.5
1480 N355LL 30.6 200 184 120 220 94.2 93.7 92.2 85.0 82.0 75.0
280 985 N355LL 32.5 200 277 100 220 94.2 93.7 92.2 80.0 75.0 65.0
740 450LS 33.0 200 369 90 210 94.0 93.5 92.0 79.0 73.0 62.0
588 450LS 35.3 200 464 80 210 93.8 93.0 91.5 74.0 67.5 55.0
2965 N355LL 32.0 225 103 120 220 94.5 94.0 93.0 91.0 88.5 83.5
1480 N355LL 33.9 225 207 110 210 94.5 94.0 93.0 86.0 83.0 76.0
315 985 N355LL 36.2 225 311 100 220 94.5 94.0 93.0 80.5 75.5 66.0
740 450LS 37.0 225 415 90 210 94.2 93.8 92.5 79.0 73.0 62.0
590 450-V 37.9 225 520 90 200 93.8 93.0 91.5 77.5 71.0 59.0
2965 N355LL 36.1 255 117 120 220 94.5 94.0 93.0 91.0 88.5 83.5
1480 N355LL 38.4 255 234 120 220 94.5 94.0 93.0 85.5 82.5 75.5
355 985 450LS 39.1 255 351 100 210 94.5 94.0 93.0 84.0 79.0 70.0
740 450LS 40.3 255 467 90 210 94.5 94.0 93.0 81.5 76.0 66.0
590 450-V 42.4 255 586 85 190 93.8 93.0 91.5 78.0 71.5 60.0
Note:1.The above data are average values for reference only.
2.Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

69
HIGH VOLTAGE VERTICAL MOTOR-TEFC
Totally Enclosed Fan-Cooled
IEC standard 3-phase 50Hz , 6600V
Class F Insulation , Continuous Duty
PERFORMANCE DATA 40℃ Ambient ,
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
RPM
KW
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
2965 N355LL 38.1 270 123 120 220 94.5 94.0 93.0 91.0 88.5 83.5
1480 N355LL 40.1 270 247 120 220 94.5 94.0 93.0 86.5 83.5 76.5
375 985 450LS 41.3 270 371 100 210 94.5 94.0 93.0 84.0 79.0 70.0
740 450-V 42.5 270 494 100 200 94.2 93.8 92.8 82.0 77.0 68.0
590 450-V 44.9 270 619 100 200 94.2 93.5 92.0 77.5 71.0 59.0
2965 450LS 40.3 280 131 110 220 94.8 94.4 93.2 91.5 89.0 84.0
1480 N355LL 42.6 280 263 110 210 94.5 94.0 93.0 87.0 84.0 77.0
400 985 450LS 43.6 280 396 100 210 94.5 94.0 93.0 85.0 80.0 71.0
740 450-V 45.0 280 526 90 190 94.2 93.8 92.8 82.5 77.5 68.0
590 450-V 47.9 280 660 90 190 94.2 93.5 92.0 77.5 71.0 59.0
2965 450LS 45.4 320 148 110 220 94.8 94.4 93.2 91.5 89.0 84.0
1485 450LS 47.4 320 295 110 220 95.0 94.5 93.5 87.5 84.5 77.5
450 985 450LS 48.9 320 445 100 210 94.8 94.4 93.2 85.0 80.0 71.0
740 450-V 50.2 320 592 90 190 94.5 94.0 93.0 83.0 78.0 69.0
590 500-V 53.9 320 743 90 190 94.3 93.7 92.0 77.5 71.0 60.0
2965 450LS 50.3 350 164 110 210 95.0 94.5 93.5 91.5 89.0 84.0
1485 450LS 52.6 350 328 110 220 95.0 94.5 93.5 87.5 84.5 77.5
500 985 400-V 55.8 350 494 90 200 94.5 94.0 93.0 83.0 78.0 69.0
740 450-V 55.8 350 658 90 190 94.5 94.0 93.0 83.0 78.0 69.0
590 500-V 59.8 350 825 90 190 94.4 93.8 92.2 77.5 71.0 60.0
2960 400-V 57.4 400 184 100 200 94.8 94.4 93.2 90.0 87.5 82.0
1485 450LS 58.6 400 367 110 220 95.0 94.5 93.5 88.0 85.0 78.0
560 985 450-V 61.0 400 554 90 200 94.5 94.0 93.0 85.0 80.0 71.0
740 500-V 63.6 400 737 100 200 94.5 94.0 93.0 81.5 76.5 67.5
590 500-V 68.7 400 924 100 200 94.5 94.0 93.0 75.5 69.0 58.0
2960 400-V 64.6 450 207 100 200 94.8 94.4 93.2 90.0 87.5 82.0
1485 450-V 65.2 450 413 100 210 95.0 94.5 93.5 89.0 86.0 80.0
630 985 450-V 68.0 450 623 90 200 94.8 94.4 93.2 85.5 81.5 72.5
740 500-V 70.5 450 829 100 200 94.8 94.4 93.2 82.5 77.5 68.5
592 560-V 75.3 450 1037 85 190 94.5 94.0 93.0 77.5 71.0 60.0
2965 450-V 72.6 505 233 110 190 95.0 94.5 93.5 90.0 87.5 82.0
1485 450-V 73.3 505 466 100 210 95.2 94.8 93.8 89.0 86.0 80.0
710 985 500-V 76.0 505 702 90 200 95.0 94.5 93.5 86.0 82.0 73.0
740 500-V 79.2 505 935 100 200 95.0 94.5 93.5 82.5 77.5 68.5
592 560-V 84.3 505 1168 85 190 94.5 94.0 93.0 78.0 71.5 60.5
2965 450-V 76.2 530 246 110 190 95.2 94.8 93.8 90.5 88.0 83.0
1485 500-V 77.4 530 492 80 210 95.2 94.8 93.8 89.0 86.0 80.0
750 985 500-V 79.2 530 742 100 210 95.2 94.8 93.8 87.0 83.0 74.5
740 500-V 84.7 530 987 100 210 95.0 94.5 93.5 81.5 76.8 67.5
592 630-V 85.4 530 1234 90 200 94.8 94.2 93.2 81.0 75.0 65.0
Note:1.The above data are average values for reference only.
2.Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.

70
HIGH VOLTAGE VERTICAL MOTOR-TEFC
Totally Enclosed Fan-Cooled
IEC standard 3-phase 50Hz , 6600V
Class F Insulation , Continuous Duty
PERFORMANCE DATA 40℃ Ambient ,
CURRENT TORQUE EFFICIENCY POWER FACTOR
OUT PUT FULL
FRAME FULL LOCKED FULL LOCKED BREAK FULL 3/4 1/2 FULL 3/4 1/2
LOAD
No. LOAD ROTOR LOAD ROTOR DOWN LOAD LOAD LOAD LOAD LOAD LOAD
RPM
KW
(A) (A) (KG-M) (%) (%) (%) (%) (%) (%) (%) (%)
2965 450-V 81.7 570 263 100 190 95.2 94.8 93.8 90.0 87.5 82.0
1485 500-V 82.6 570 525 80 210 95.2 94.8 93.8 89.0 86.0 80.0
800 985 500-V 84.0 570 791 90 210 95.2 94.8 93.8 87.5 83.5 75.0
740 500-V 89.8 570 1053 100 200 95.0 94.5 93.5 82.0 77.0 68.0
592 630-V 91.1 570 1316 85 190 94.8 94.2 93.2 81.0 75.0 65.0
2970 500-V 92.9 640 295 110 200 95.2 94.8 93.8 89.0 86.5 81.0
1485 500-V 92.9 640 590 80 210 95.2 94.8 93.8 89.0 86.0 80.0
900 985 500-V 95.6 640 890 90 200 95.2 94.8 93.8 86.5 82.5 74.0
740 560-V 99.6 640 1185 100 200 95.2 94.8 93.8 83.0 78.0 69.0
592 630-V 102 640 1481 90 200 95.0 94.5 93.5 81.0 75.0 65.0
2970 500-V 103 710 328 110 200 95.2 94.8 93.8 89.0 86.5 81.0
1485 500-V 102 710 656 80 210 95.5 95.0 94.0 90.0 87.0 82.0
1000 985 500-V 106 710 989 90 210 95.5 95.0 94.0 86.5 82.5 74.0
740 560-V 111 710 1316 100 210 95.2 94.8 93.8 82.5 77.5 68.5
592 630-V 113 710 1645 85 190 95.0 94.5 93.5 81.5 75.5 65.5
2970 500-V 114 800 367 110 200 95.5 95.0 94.0 90.0 87.5 82.0
1485 500-V 114 800 735 90 210 95.5 95.0 94.0 90.0 87.0 82.0
1120 985 560-V 121 800 1107 90 200 95.5 95.0 94.0 84.5 80.0 72.0
740 630-V 124 800 1474 80 190 95.5 95.0 94.0 82.5 77.5 68.5
592 630-V 129 800 1843 90 200 95.2 94.8 93.8 80.0 74.0 64.0
2970 500-V 127 890 410 110 200 95.5 95.0 94.0 90.0 87.5 82.0
1485 560-V 127 890 820 90 220 95.6 95.2 94.2 90.0 87.0 82.0
1250 985 560-V 134 890 1236 90 200 95.5 95.0 94.0 85.5 81.0 73.0
740 630-V 138 890 1645 80 190 95.5 95.0 94.0 83.0 78.0 69.0
593 710-V 141 890 2053 80 180 95.2 94.8 93.8 81.5 75.5 65.5
2970 500-V 152 1060 492 110 200 95.5 95.0 94.0 90.5 88.0 83.0
1485 560-V 153 1060 984 90 220 95.6 95.2 94.2 90.0 87.0 82.0
1500 990 630-V 156 1060 1476 90 200 95.5 95.0 94.0 88.0 84.0 76.0
740 630-V 165 1060 1974 80 180 95.5 95.0 94.0 83.5 78.5 70.0
593 710-V 168 1060 2464 85 190 95.5 95.0 94.0 82.0 76.0 66.0
Note:1.The above data are average values for reference only.
2.Performance tolerance is according to IEC 34-1.
ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE.