You are on page 1of 6

Gray Cells Indicate User Input

Torque Values for ASTM A 193 B5 Bolts @ 60 % Yield

Bolt Torque Value (ft-lbf) Torque Value (ft-lbf) Using Torque Value(ft-lbf) Using
Bolt Size SMYS 60 % SMYS Using Friction Factor Friction Factor Friction Factor
TPI (n) Area-As
(in) (lbf/in2) lbf/in2 for Jet Lube -550 for Jet Lube-Kopr Kote for Jet Lube-Nikal
(in2)
u= 0.08 u= 0.11 u= 0.15
0.500 13 80,000 48,000 0.142 38 50 65
0.625 11 80,000 48,000 0.226 72 96 127
0.750 10 80,000 48,000 0.334 125 167 222
0.875 9 80,000 48,000 0.462 197 265 353
1.000 8 80,000 48,000 0.606 291 393 525
1.125 8 80,000 48,000 0.790 422 571 766
1.250 8 80,000 48,000 1.000 588 797 1,071
1.500 8 80,000 48,000 1.492 1,040 1,413 1,902
1.625 8 80,000 48,000 1.775 1,334 1,813 2,444
1.875 8 80,000 48,000 2.414 2,077 2,828 3,818
2.000 8 80,000 48,000 2.771 2,534 3,453 4,665
2.500 8 80,000 48,000 4.442 5,030 6,868 9,296
3.000 8 80,000 48,000 6.506 8,785 12,009 16,276
3.250 8 80,000 48,000 7.686 11,216 15,338 20,798
3.500 8 80,000 48,000 8.963 14,057 19,232 26,088
4.000 8 80,000 48,000 11.813 21,102 28,888 39,214

KLR U:\1Inspection\Bolting Flange Information_files\621439370.xls


Gray Cells Indicate User Input

Torque Values for ASTM A 193 B6 Bolts @ 70 % Yield

Bolt Torque Value (ft-lbf) Torque Value (ft-lbf) Using Torque Value(ft-lbf) Using
Bolt Size SMYS 70 % SMYS Using Friction Factor Friction Factor Friction Factor
TPI (n) Area-As
(in) (lbf/in2) lbf/in2 for Jet Lube -550 for Jet Lube-Kopr Kote for Jet Lube-Nikal
(in2)
u= 0.08 u= 0.11 u= 0.15
0.500 13 85,000 59,500 0.142 47 62 81
0.625 11 85,000 59,500 0.226 90 119 157
0.750 10 85,000 59,500 0.334 155 207 275
0.875 9 85,000 59,500 0.462 244 328 438
1.000 8 85,000 59,500 0.606 361 487 651
1.125 8 85,000 59,500 0.790 524 708 950
1.250 8 85,000 59,500 1.000 729 988 1,327
1.500 8 85,000 59,500 1.492 1,289 1,751 2,358
1.625 8 85,000 59,500 1.775 1,653 2,248 3,030
1.875 8 85,000 59,500 2.414 2,574 3,506 4,733
2.000 8 85,000 59,500 2.771 3,141 4,281 5,783
2.500 8 85,000 59,500 4.442 6,235 8,513 11,523
3.000 8 85,000 59,500 6.506 10,890 14,887 20,176
3.250 8 85,000 59,500 7.686 13,903 19,013 25,781
3.500 8 85,000 59,500 8.963 17,425 23,839 32,338
4.000 8 85,000 59,500 11.813 26,157 35,809 48,608

KLR U:\1Inspection\Bolting Flange Information_files\621439370.xls


Gray Cells Indicate User Input

Torque Values for ASTM A 193 B6X Bolts @ 70 % Yield

Bolt Torque Value (ft-lbf) Torque Value (ft-lbf) Using Torque Value(ft-lbf) Using
Bolt Size SMYS 70 % SMYS Using Friction Factor Friction Factor Friction Factor
TPI (n) Area-As
(in) (lbf/in2) lbf/in2 for Jet Lube -550 for Jet Lube-Kopr Kote for Jet Lube-Nikal
(in2)
u= 0.08 u= 0.11 u= 0.15
0.500 13 70,000 49,000 0.142 39 51 67
0.625 11 70,000 49,000 0.226 74 98 130
0.750 10 70,000 49,000 0.334 127 171 227
0.875 9 70,000 49,000 0.462 201 270 361
1.000 8 70,000 49,000 0.606 297 401 536
1.125 8 70,000 49,000 0.790 431 583 782
1.250 8 70,000 49,000 1.000 601 814 1,093
1.500 8 70,000 49,000 1.492 1,062 1,442 1,942
1.625 8 70,000 49,000 1.775 1,361 1,851 2,495
1.875 8 70,000 49,000 2.414 2,120 2,887 3,898
2.000 8 70,000 49,000 2.771 2,587 3,525 4,763
2.500 8 70,000 49,000 4.442 5,135 7,011 9,490
3.000 8 70,000 49,000 6.506 8,969 12,259 16,615
3.250 8 70,000 49,000 7.686 11,449 15,658 21,232
3.500 8 70,000 49,000 8.963 14,350 19,632 26,632
4.000 8 70,000 49,000 11.813 21,541 29,490 40,031

KLR U:\1Inspection\Bolting Flange Information_files\621439370.xls


Gray Cells Indicate User Input

Torque Values for ASTM A 193 B7 Bolts @ 100 % Yield

Bolt Torque Value (ft-lbf) Torque Value (ft-lbf) Using Torque Value(ft-lbf) Using
Bolt Size SMYS 100 % SMYS Using Friction Factor Friction Factor Friction Factor
TPI (n) Area-As
(in) (lbf/in2) lbf/in2 for Jet Lube -550 for Jet Lube-Kopr Kote for Jet Lube-Nikal
(in2)
u= 0.08 u= 0.11 u= 0.15
0.500 13 105,000 105,000 0.142 83 109 143
0.625 11 105,000 105,000 0.226 158 210 278
0.750 10 105,000 105,000 0.334 273 365 485
0.875 9 105,000 105,000 0.462 431 580 773
1.000 8 105,000 105,000 0.606 636 859 1,149
1.125 8 105,000 105,000 0.790 924 1,250 1,676
1.250 8 105,000 105,000 1.000 1,287 1,744 2,342
1.500 8 105,000 105,000 1.492 2,275 3,090 4,162
1.625 8 105,000 105,000 1.775 2,917 3,967 5,347
1.875 8 105,000 105,000 2.414 4,543 6,187 8,353
2.000 8 105,000 105,000 2.771 5,543 7,554 10,206
2.500 8 95,000 95,000 4.442 9,956 13,592 18,399
3.000 8 95,000 95,000 6.506 17,388 23,768 32,214
3.250 8 95,000 95,000 7.686 22,198 30,357 41,163
3.500 8 95,000 95,000 8.963 27,821 38,063 51,633
4.000 8 75,000 75,000 11.813 32,971 45,138 61,271
5.000 8 75,000 75,000 18.690 64,905 88,934 120,832

KLR U:\1Inspection\Bolting Flange Information_Files\621439370.xls


Gray Cells Indicate User Input

Torque Values for ASTM A 193 B7M Bolts @ 70 % Yield

Bolt Torque Value (ft-lbf) Torque Value (ft-lbf) Using Torque Value(ft-lbf) Using
Bolt Size SMYS 70 % SMYS Using Friction Factor Friction Factor Friction Factor
TPI (n) Area-As
(in) (lbf/in2) lbf/in2 for Jet Lube -550 for Jet Lube-Kopr Kote for Jet Lube-Nikal
(in2)
u= 0.08 u= 0.11 u= 0.15
0.500 13 80,000 56,000 0.142 44 58 76
0.625 11 80,000 56,000 0.226 84 112 148
0.750 10 80,000 56,000 0.334 145 195 259
0.875 9 80,000 56,000 0.462 230 309 412
1.000 8 80,000 56,000 0.606 339 458 613
1.125 8 80,000 56,000 0.790 493 667 894
1.250 8 80,000 56,000 1.000 686 930 1,249
1.500 8 80,000 56,000 1.492 1,213 1,648 2,220
1.625 8 80,000 56,000 1.775 1,556 2,116 2,852
1.875 8 80,000 56,000 2.414 2,423 3,299 4,455
2.000 8 80,000 56,000 2.771 2,956 4,029 5,443
2.500 8 80,000 56,000 4.442 5,869 8,012 10,845
3.000 8 80,000 56,000 6.506 10,250 14,011 18,989
3.250 8 80,000 56,000 7.686 13,085 17,895 24,265
3.500 8 80,000 56,000 8.963 16,400 22,437 30,436
4.000 8 80,000 56,000 11.813 24,619 33,703 45,749
5.000 8 75,000 52,500 18.690 45,433 62,253 84,583

KLR U:\1Inspection\Bolting Flange Information-files\621439370.xls


Gray Cells Indicate User Input

Torque Values for ASTM A 193 B16 Bolts @ 70 % Yield

Bolt Torque Value (ft-lbf) Torque Value (ft-lbf) Using Torque Value(ft-lbf) Using
Bolt Size SMYS 70 % SMYS Using Friction Factor Friction Factor Friction Factor
TPI (n) Area-As
(in) (lbf/in2) lbf/in2 for Jet Lube -550 for Jet Lube-Kopr Kote for Jet Lube-Nikal
(in2)
u= 0.08 u= 0.11 u= 0.15
0.500 13 105,000 73,500 0.142 58 77 100
0.625 11 105,000 73,500 0.226 111 147 195
0.750 10 105,000 73,500 0.334 191 256 340
0.875 9 105,000 73,500 0.462 302 406 541
1.000 8 105,000 73,500 0.606 446 601 804
1.125 8 105,000 73,500 0.790 647 875 1,173
1.250 8 105,000 73,500 1.000 901 1,221 1,640
1.500 8 105,000 73,500 1.492 1,592 2,163 2,913
1.625 8 105,000 73,500 1.775 2,042 2,777 3,743
1.875 8 105,000 73,500 2.414 3,180 4,331 5,847
2.000 8 105,000 73,500 2.771 3,880 5,288 7,144
2.500 8 105,000 73,500 4.442 7,702 10,516 14,235
3.000 8 95,000 66,500 6.506 12,172 16,638 22,550
3.250 8 95,000 66,500 7.686 15,538 21,250 28,814
3.500 8 95,000 66,500 8.963 19,475 26,644 36,143
4.000 8 95,000 66,500 11.813 29,235 40,022 54,327
5.000 8 85,000 59,500 18.690 51,491 70,554 95,860

KLR U:\1Inspection\Bolting Flange Information-files\621439370.xls