Measuring & Protective Current Transformer

Manufactured To: IEC 185 & BS 7626

CURRENT TRANSFORMER
PERFORMANCE The M&P series are complied with BS 7626 and IEC 185
The technical characteristic as follows :
» Primary current : 60A to 6000A
» Secondary current : 5A or 1A
» Maximun voltage : 0.66 kV
» Test voltage : 3 kV/min
» Frequency : 50 ~ 60 Hz
» Burden : 5VA to 30VA
» Class :
Measuring CTs : 0.5, 1, 3
Protection CTs : 5P, 10P
» Short time thermal current : Ith = 60In
» Dynamic rated current : Idyn = 2.5Ith
» Standard accuracy limit factor : 5, 10, 15
» Operating temperature : - 50C to 400C
Epoxy Resin Coating Current Transformer

DIMENSIONS(mm)
MEASURING TYPE PROTECTION TYPE
RATIO
ID OD HT
ID OD HT
5P5 5P10 5P5 5P10 5P5 5P10
60/5A 35 85 50 _ _ _ _ _ _
100/5A 35 75 30 38 38 120 120 115 130
150/5A 35 70 30 38 38 110 110 95 105
200/5A 35 65 30 38 38 100 100 90 105
250/5A 35 65 30 38 38 95 95 90 105
300/5A 50 80 30 48 48 110 110 80 100
400/5A 52 80 25 52 52 105 105 70 85
500/5A 52 80 25 52 52 95 95 62 78
600/5A 65 90 25 65 65 115 115 60 65
800/5A 80 105 25 80 80 120 120 50 65
1000/5A 85 110 25 85 85 125 125 45 55
1200/5A 85 110 25 85 85 125 125 45 55
1600/5A 85 110 25 85 85 125 125 40 45
2000/5A 120 150 25 120 120 150 150 35 43
2500/5A 120 150 25 120 120 150 150 30 40
3000/5A 120 160 30 120 130 165 165 30 35
4000/5A 130 160 30 130 130 168 168 30 35
5000/5A 130 170 30 130 130 168 168 30 35
6000/5A 165 180 30 165 165 190 190 30 35

Measuring & Protective Current Transformer


Manufactured To: IEC 185 & BS 7626
EPOXY RESIN COATING CURRENT
TRANSFORMER
Measurement & Protection Type
Insulation Class "B"
Special core size, terminal arrangements
and output leads

EPOXY RESIN COATING CURRENT


TRANSFORMER SQUARE TYPE
Measurement & Protection Type
Insulation Class "B"
Special core size, terminal arrangements and
output leads

EPOXY RESIN COATING CURRENT


TRANSFORMER SQUARE TYPE
Measurement Class 0.5, 1 & 3 available
Compacted and easily mounted
Transparent terminal covers are supplied and
6.3mm push on tags for connection of shorting link.
Insulation Class "B"
Flame temperature range -30oC to 85oC case
insulation withstand 125oC for 1 hour and 140oC
for 10 minutes.
Enclosure - IP54

CURRENT TRANSFORMER
PERFORMANCE
The M&P series are complied with BS 7626 and IEC 185
The technical characteristic as follows :
» Primary current : 400A to 6000A
» Secondary current : 5A or 1A
» Maximun voltage : 0.66 kV
» Test voltage : 3 kV/min
» Frequency : 50 ~ 60 Hz
» Burden : 5VA to 30VA

» Class :
Measuring CTs : 0.5, 1, 3
Protection CTs : 5P, 10P

Epoxy Resin Coating


» Short time thermal current : Ith = 60In Current Transformer square type
» Dynamic rated current : Idyn = 2.5Ith
» Standard accuracy limit factor : 5, 10, 15
» Operating temperature : - 50C to 400C

Burden (VA)
Ratio MEASURING TYPE PROTECTION TYPE BUSBAR HOLE DIMENSIONS(mm)
5P5 5P10
400/5A 5 15 15 20 10 X 30 mm
500/5A 5 15 15 20 10 X 30 mm
600/5A 5 15 15 20 10 x 40 mm
800/5A 5 15 15 20 10 x 50 mm
1000/5A 5 15 15 20 10 x 60 mm
1200/5A 5 15 15 20 10 x 80 mm
1500/5A 5 15 15 20 10 x 80 x 2 mm
1600/5A 5 15 15 20 10 x 80 x 2 mm
2000/5A 5 15 15 20 10 x 80 x 2 mm
2500/5A 5 15 15 20 10 x 100 x 2 mm
3000/5A 5 15 15 20 10 x 120 x 2 mm
4000/5A 5 15 15 20 10 x 150 x2 mm
5000/5A 5 15 15 20 10 x 150 x 3 mm
6000/5A 5 15 15 20 10 x 150 x 4 mm