Delete the following: Material”; and a radioactive symbol. The labeling contains a
statement of radionuclide purity, identifies probable
radionuclidic impurities, and indicates permissible quantities

Xenon Xe 127 of each impurity. The labeling indicates that in making dosage
calculations, correction is to be made for radioactive decay,
» Xenon Xe 127 is a gas suitable for inhalation in and also indicates that the radioactive half-life of 127Xe is

al
36.41 days.
diagnostic studies. Xenon 127 is a radioactive Radionuclide identification (see Radioactivity á821ñ)—Its
nuclide that may be prepared from the gamma-ray spectrum is identical to that of a known specimen
bombardment of a cesium 133 target with of xenon 127 that exhibits major photopeaks at 202.8 keV,
high-energy protons. It contains not less than 85.0 and 172.1 keV, and 375.0 keV. Minor photopeaks from other

ci
percent and not more than 115.0 percent of the xenon radioisotopes, namely Xe 129m (197 keV) and Xe
131m (164 keV) may also be present.
labeled amount of 127Xe at the calibration date Radionuclidic purity—Using a suitable counting assembly,
indicated on the labeling. determine the radioactivity of the Xe 127 in the gas by use of a
calibrated system as directed under Radioactivity á821ñ. Using
Packaging and storage—Preserve in single-dose vials

ffi
the gamma-ray spectrum, determine the energy of each
having leak-proof stoppers, at room temperature. The vials are gamma photopeak. Identify each radionuclide present, and
enclosed in appropriate lead radiation shields. The vial content using the established detector efficiency and known gamma
may be diluted with air and is packaged at atmospheric abundance, calculate the quantity of each radionuclide
pressure. present in the specimen in MBq (mCi). The amount of Xe 127
Labeling—Label it to include the following: the name of the present in the specimen is not less than 80%; the quantity of

O
preparation; the container volume, MBq (mCi) of 127Xe per either Xe 131m or Xe 129m does not exceed 10%, and no
container; the amount of 127Xe expressed as megabecquerels other radioisotope exceeds 1%.
(millicuries) per mL; the intended route of administration; Assay for radioactivity—Using a suitable counting
recommended storage conditions; the date of calibration; the assembly, determine the radioactivity, in MBq (mCi), of Xe
expiration date; the name, address, and batch number of the 127 in each container by use of a calibrated system as
manufacturer; the statement “Caution—Radioactive directed under Radioactivity á821ñ.▲ (USP 1-May-2019)