You are on page 1of 1

Hydrostatic Test

Vertical shop hydrostatic test based on MAWP per UG-99(b)

Gauge pressure at 25°C = 1.3 ⋅ M AW P ⋅ LSR


= 1.3 ⋅ 1,633.6 ⋅ 1

=2,123.69 kPa

Vertical shop hydrostatic test


Local test Test liquid UG-99(b) UG-99(b) Stress Allowable Stress
Identifier pressure static head stress pressure during test test stress excessive?
(kPa) (kPa) ratio factor (MPa) (MPa)
Top Head (1) 2,125.44 1.76 1 1.30 114.391 186.3 No

Straight Flange on Top Head 2,125.44 1.76 1 1.30 79.699 186.3 No

Shell 2,139.06 15.38 1 1.30 107.306 186.3 No

Straight Flange on Bottom Head 2,139.36 15.67 1 1.30 80.221 186.3 No

Bottom Head 2,140.82 17.14 1 1.30 115.219 186.3 No

Air Inlet (N1) 2,129.85 6.16 1 1.30 150.041 279.45 No

Drain (N4) 2,142.49 18.81 1 1.30 147.723 279.45 No

Hand Hole (N8) 2,134.03 10.35 1 1.30 271.7 279.45 No

PSV (N2) 2,129.85 6.16 1 1.30 150.041 279.45 No

Pressure Gauge (N3) 2,129.85 6.16 1 1.30 150.041 279.45 No

Spare nozzle (N5) 2,129.85 6.16 1 1.30 150.041 279.45 No

(1) Top Head limits the UG-99(b) stress ratio.


(2) PL stresses at nozzle openings have been estimated using the method described in Division 2 Part 4.5.
(3) 1.5*0.9*Sy used as the basis for the maximum local primary membrane stress at the nozzle intersection PL.

The field test condition has not been investigated.