You are on page 1of 302

Company: CYTEC Corporation

Model Tested: RS-8-S-R Mainframe


Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

TEST SPECIFICATIONS:

RTCA/DO/160D (July 29, 1997)

RADIO TECHNICAL COMMISSION FOR AERONAUTICS

ENVIRONMENTAL CONDITIONS

AND

TEST PROCEDURES FOR AIRBORNE EQUIPMENT

THE FOLLOWING ''MEETS'' Section 16, Section 17, Section 18, Section 19, Section 20, & Section 21
TEST PROCEDURE(S) OF THE ABOVE TEST SPECIFICATION

Formal Name: Ruggadized 9 Pole Switching Multiplexer

Kind of Equipment: Switching Multiplexer - 9 Poles

Test Configuration: 8x1 Nine Pole Multiplexer (Tested at 115 vac, 400 Hz)

Model Number(s): RS/8-S-R Mainframe

Model(s) Tested: RS-8-S-R Mainframe

Serial Number(s): 136906

Date of Tests: March 27, 29, 30, 31 and April 2, 3, 5, 6, & 7, 2004

Test Conducted for: CYTEC Corporation


2555 Baird Road
Penfield, New York 145265

NOTICE: “This report must not be used by the client to claim product endorsement by NVLAP or any
agency of the U.S. Government”. Please see the "Additional Description of Equipment Under Test" page
listed inside of this report. This report must not be reproduced (except in full), without the approval of
D.L.S. Electronic Systems.

Page -1-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SIGNATURE PAGE

Report Written By:

Arnom C. Rowe
Test Engineer
EMC-001375-NE

Report Reviewed By:

Jack Prawica
Lab Manager
EMC-002412-NE

Report Approved By:

Brian J. Mattson
General Manager

Test Witnessed By:

Mail Order
CYTEC Corporation

Company Official:

CYTEC Corporation

Page -2-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Page -3-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Page -4-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Page -5-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Page -6-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Page -7-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Page -8-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Page -9-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Page -10-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Page -11-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Page -12-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

TABLE OF CONTENTS

i. Cover Page................................................................................................................................................ 1
ii. Signature Page ...................................................................................................................................... 2
iii. NVLAP Certificate of Accreditation .................................................................................................... 3
iv. NVLAP Scope of Accreditation ........................................................................................................... 4
v. Table of Contents................................................................................................................................ 13
1.0 Introduction......................................................................................................................................... 16
2.0 Test Equipment ................................................................................................................................... 16
3.0 Test Set-Up ......................................................................................................................................... 17
4.0 Operating Conditions of Test Sample................................................................................................. 18
5.0 Performance Monitored ...................................................................................................................... 19
6.0 Description of Test Sample................................................................................................................. 20
7.0 Additional Description of Equipment Under Test.............................................................................. 23
8.0 Photo Information and Test Setup ...................................................................................................... 24
9.0 Photos Taken During Testing ............................................................................................................. 25
10.0 References....................................................................................................................................... 26
11.0 Test Results..................................................................................................................................... 27
12.0 Conclusion of Immunity Tests........................................................................................................ 27

Section 16 Power Input.................................................................................................................................. 28


1.0 Purpose of Test ................................................................................................................................... 29
2.0 Equipment Categories......................................................................................................................... 29
3.0 Test Setup and Apparatus ................................................................................................................... 30
4.0 Test Procedure .................................................................................................................................... 31
5.0 Limits & Results ................................................................................................................................. 33
5.2 Power Input Test Data Sheets............................................................................................................. 38
6.0 Photos Taken During Testing ............................................................................................................. 43
Section 16 Test Instrumentation / Table 1 ................................................................................................... 44

Section 17 Voltage Spike............................................................................................................................... 45


1.0 Purpose of Test ................................................................................................................................... 46
2.0 Equipment Categories......................................................................................................................... 46
3.0 Test Setup and Apparatus ................................................................................................................... 47
4.0 Test Procedure .................................................................................................................................... 48
5.0 Limits & Results ................................................................................................................................. 49
5.2 Voltage Spike Test Check Off Sheet(s).............................................................................................. 50
5.2 Voltage Spike Calibration Data Sheet(s) ............................................................................................ 52
5.2 Voltage Spike Test Data Sheet(s) ....................................................................................................... 59
6.0 Voltage Spike Photos Taken During Testing ..................................................................................... 62
Section 17 Test Instrumentation / Table 1 ................................................................................................... 65
Section 17 Test Equipment / Table 2........................................................................................................... 66

Page -13-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

TABLE OF CONTENTS

Section 18 Audio Frequency Conducted Susceptibility – Power Inputs ....................................................... 67


1.0 Purpose of Test ................................................................................................................................... 68
2.0 Equipment Categories......................................................................................................................... 68
3.0 Test Setup and Apparatus ................................................................................................................... 69
4.0 Test Procedure .................................................................................................................................... 70
5.0 Limits & Results ................................................................................................................................. 71
5.2 Audio Frequency Test Data Sheet(s) .................................................................................................. 72
5.2 Audio Frequency Calibration Data Sheet(s)....................................................................................... 74
5.2 Audio Frequency Test Data Sheets..................................................................................................... 76
6.0 Audio Frequency Power Inputs Photos Taken During Testing ...................................................... 78
Section 18 Test Instrumentation / Table 1 ................................................................................................... 80
Section 18 Test Equipment / Table 2........................................................................................................... 81

Section 19 Induced Signal Susceptibility ...................................................................................................... 82


1.0 Purpose of the Test ............................................................................................................................. 83
2.0 Equipment Categories......................................................................................................................... 83
3.0 Test Setup and Apparatus ................................................................................................................... 84
4.0 Test Procedure .................................................................................................................................... 88
5.0 Limits & Results ................................................................................................................................. 89
5.0 Limits & Results ................................................................................................................................. 90
5.2 Magnetic Field Check Off Sheet(s) .................................................................................................... 91
5.2 Magnetic Fields Induced Into the Equipment................................................................................... 102
5.2 Induced Signal Susceptibility Test Data Sheet(s)............................................................................. 103
5.2 Magnetic Fields Induced Into Interconnecting Cables ..................................................................... 105
5.2 Induced Signal Susceptibility Test Data Sheet(s)............................................................................. 106
5.2 Electric Fields Induced Into Interconnecting Cables........................................................................ 110
5.2 Induced Signal Susceptibility Test Data Sheet(s)............................................................................. 111
5.2 Spikes Induced Into Interconnecting Cables .................................................................................... 115
5.2 Induced Signal Susceptibility Calibration Data Sheet(s).................................................................. 116
5.2 Induced Signal Susceptibility Test Data Sheet(s)............................................................................. 125
6.0 Induced Signal Photos Taken During Testing .................................................................................. 132
Section 7.0 Test Instrumentation / Table 1 ................................................................................................ 143
Section 19.3.1 Test Equipment / Table 2................................................................................................... 144
Section 19.3.2 Test Instrumentation / Table 3 ........................................................................................... 145
Section 19.3.2 Test Equipment / Table 4................................................................................................... 146
Section 19.3.3 Test Instrumentation / Table 5 ........................................................................................... 147
Section 19.3.3 Test Equipment / Table 6................................................................................................... 148
Section 19.3.4 Test Instrumentation / Table 7 ........................................................................................... 149
Section 19.3.4 Test Equipment / Table 8................................................................................................... 150

Page -14-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

TABLE OF CONTENTS

Section 20.4 Conducted Susceptibility 10 kHz – 400 MHz ....................................................................... 151


1.0 Purpose of the Test ........................................................................................................................... 152
2.0 Equipment Categories....................................................................................................................... 153
3.0 Test Setup and Apparatus ................................................................................................................. 154
4.0 Test Procedure .................................................................................................................................. 155
5.0 Limits & Results ............................................................................................................................... 157
5.2 Calibration and Conducted Susceptibility Test Data Sheets .................................................... 158
6.0 Photos Taken During Testing ........................................................................................................... 187
Section 20.4 Test Instrumentation / Table 1 .............................................................................................. 191
Section 20.4 Test Equipment / Table 2...................................................................................................... 192

Section 20.5 Radiated Susceptibility 100 MHz – 18 GHz ......................................................................... 193


1.0 Purpose of the Test ........................................................................................................................... 194
2.0 Equipment Categories....................................................................................................................... 195
3.0 Test Setup and Apparatus ................................................................................................................. 196
4.0 Test Procedure .................................................................................................................................. 197
5.0 Limits & Results ............................................................................................................................... 199
5.2 Radiated Susceptibility Forward Power CW Test Data Sheets .................................................... 200
5.2 Radiated Susceptibility Forward Power SW Test Data Sheets..................................................... 207
5.2 Radiated Susceptibility Probe CW Test Data Sheets........................................................................ 214
5.2 Radiated Susceptibility Probe SW Test Data Sheets ........................................................................ 221
6.0 Photos Taken During Testing ........................................................................................................... 228
Section 20.5 Test Instrumentation / Table 1 .............................................................................................. 237
Section 20.5 Test Equipment / Table 2...................................................................................................... 238

Section 21 Emission of Radio Frequency Energy 2 MHz – 6 GHz ........................................................... 239


1.0 Purpose of Test ................................................................................................................................. 240
2.0 Equipment Categories....................................................................................................................... 240
3.0 Test Setup and Apparatus ................................................................................................................. 241
4.0 Test Procedure .................................................................................................................................. 242
5.0 Limits & Results ............................................................................................................................... 244
5.2 Emission of Radio Frequency Energy / Verification Data and Graphs .................................... 247
5.2 Emission of Radio Frequency Energy / Conducted Emission Graphs ..................................... 261
5.2 Emission of Radio Frequency Energy / Radiated Emission Graphs ................................... 270
6.0 Conducted Emissions Photos Taken During Testing ....................................................................... 285
6.0 Radiated Emissions Photos Taken During Testing........................................................................... 289
Section 21.3 Test Instrumentation / Table 1 .............................................................................................. 299
Section 21.3 Test Equipment / Table 2...................................................................................................... 300
Section 21.4 Test Instrumentation / Table 1 .............................................................................................. 301
Section 21.4 Test Equipment / Table 2...................................................................................................... 302

Page -15-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

1.0 INTRODUCTION:

On March 27, 29, 30, 31 and April 2, 3, 5, 6, & 7, 2004, a series of susceptibility tests was made to
demonstrate that the Ruggadized 9 Pole Switching Multiplexer, Model Number(s) RS/8-S-R
Mainframe, Serial Number 136906, manufactured by CYTEC Corporation, ''meets'' the emissions
and susceptibility requirements of RTCA/DO-160D, Change Number 2 (June 12, 2001),
Environmental conditions and Test Procedures for Airborne Equipment, using the following test
procedure(s): Section 16, Section 17, Section 18, Section 19, Section 20, & Section 21. The tests
were performed by personnel of D.L.S. Electronic Systems, Inc., who are responsible to Donald L.
Sweeney, Senior EMC Engineer.

This test report relates only to the items tested and contains the following number of pages:

Text: 302 pages

2.0 TEST EQUIPMENT:

A list of the test equipment used, along with identification and calibration data, is included in the
Table of each Appendix of this report. All primary equipment was calibrated against known
reference standards with a verified traceable path to NIST.

Page -16-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

3.0 TEST SET-UP:

All susceptibility tests were performed at D.L.S. Electronic Systems, Inc. The Ruggadized 9 Pole
Switching Multiplexer was placed on a non-conductive table. The following describes the various
Labs that are used for testing:

LAB B 20' long x 10' wide x 10' high double-walled, shielded enclosure (this shielded
enclosure is broken into two 10' x 10' x 10' identical size rooms).
LAB C 26' long x 16' wide x 16' high semi-ferrite lined enclosure.
LAB E 26' long x 16' wide x 16' high semi-ferrite lined enclosure.
LAB F 34' long x 24' wide x 13' high anechoic/ferrite tiled lined enclosure.
LAB H 20' long x 10' wide x 10' high screen shielded enclosure.
LAB J 21' long x 10' wide x 10' high screen shielded enclosure.
LAB K 16' long x 10' wide x 10' high screen shielded enclosure.
LAB L 20' long x 10' wide x 10' high ferrite tiled lined enclosure.
LAB M 20' long x 12' wide x 12' high screen shielded enclosure.
LAB Q* 36' long x 25' wide x 20' high screen shielded enclosure.
LAB R* 36' long x 25' wide x 20' high screen shielded enclosure.
LAB S* 36' long x 25' wide x 20' high screen shielded enclosure.

*Electromagnetic field absorbers were strategically placed according to Figure 21-7 of the
RTCA/DO-160 Standard. All lines leaving the room were filtered. The load banks were located
outside the main room. The shielded load bank room measured 6' x 6' x 8'.

The tests were run in the following labs:

LAB S Section 16, Power Input


LAB S Section 17, Voltage Spike
LAB S Section 18, Audio Frequency Conducted Susceptibility - Power Inputs
LAB S Section 19, Induced Signal Susceptibility
LAB S Section 20.4, Conducted Susceptibility
LAB S Section 20.5, Radiated Susceptibility
LAB S Section 21, Emission of Radio Frequency Energy

*Tests were not performed

Page -17-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

4.0 OPERATING CONDITIONS OF TEST SAMPLE:

All test measurements were made at a laboratory temperature of 72°F at 40% humidity with the
following mode of operation:

Loop communication was established from external PCU to the “I/O Signal” Port on the EUT and
than from Port “O” to external PCU. RS-232 communication was continued during the tests.

Page -18-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

5.0 PERFORMANCE MONITORED:

The Ruggadized 9 Pole Switching Multiplexer performance was monitored as follows:

The RS-232 communication cable was monitored during all of the performed tests. Any
interruptions in data flow would be considered abnormal.

Page -19-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 DESCRIPTION OF TEST SAMPLE: (See also Paragraph 7.0)

6.1 DESCRIPTION:

This unit is a special, "ruggadized" 8 to 1, nine pole, computer controlled switching


multiplexer. Remote computer control is via RS232. The unit is intended to switch nine
wire RS232 level signals. It will be eventually be installed on a military aircraft.

Page -20-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 DESCRIPTION OF TEST SAMPLE: (CON'T)

6.2 PHYSICAL DIMENSIONS OF EQUIPMENT UNDER TEST:

Length: 15.6" Width: 19" x Height: 3.5"

6.3 LINE FILTER USED:

Corcom 5EFLA2S

6.4 INTERNAL CLOCK FREQUENCIES:

Switching Power Supply Frequencies:

LINEAR Power Supply Used

Clock Frequencies:

11.0592 MHz

Page -21-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 DESCRIPTION OF TEST SAMPLE: (CON'T)

6.5 DESCRIPTION OF ALL CIRCUIT BOARDS:

1. IF-3A RS232 Control Module - Qty 1 PN: 11-00-10

2. RS/8 Motherboard - Qty. 1 PN: 2-077-1 Cut

3. Switch Module Driver Backplane - Qty 1 PN: 2-013-3 Cut

4. RS/9-P Switch Module - Qty. 8 PN: 2-451-1

5. RS/9-P Signal I/O Module - Qty. 1 PN: 2-451-1SIO

6. Front Panel LED Indicator - Qty. 1 PN: 5-020-3

7. PS/12-5 Power Supply, 12 V with 5 V Regulator - Qty. 1 PN: HB12-1.7A+

Page - 22 -
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

7.0 ADDITIONAL DESCRIPTION OF EQUIPMENT UNDER TEST:


(See also Paragraph 6.0)

1: There were no changes made at D.L.S. Electronic Systems, Inc.

I certify that the above, combined with paragraph 6.0, describes the equipment tested and that the equipment
will be manufactured as stated.

by________________________________________ ____________________________________
Signature Title

for________________________________________ ____________________________________
Company Name Date

Page -23-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

8.0 PHOTO INFORMATION AND TEST SETUP:

The test setup can be seen in the accompanying photograph.

Item 0 Ruggadized 9 Pole Switching Multiplexer


Model Number: RS-8-S-R Mainframe

Page -24-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

9.0 PHOTOS TAKEN DURING TESTING:

Page -25-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

10.0 REFERENCES:

1. Document No. RTCA/DO-160D, July 29, 1997


Prepared by: SC-135

Page -26-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

11.0 TEST RESULTS:

The Ruggadized 9 Pole Switching Multiplexer was subject to the test procedure(s) Section 16,
Section 17, Section 18, Section 19, Section 20, & Section 21. A detailed explanation of how these
tests and their measurements were made is shown in Appendix(es) A-G at the end of this report.

12.0 CONCLUSION OF IMMUNITY TESTS:

The Ruggadized 9 Pole Switching Multiplexer, Model Number(s) RS/8-S-R Mainframe, ''meets''
RTCA/DO-160D (July 29, 1997), Environmental conditions and Test Procedures for Airborne
Equipment using test procedure(s) Section 16, Section 17, Section 18, Section 19, Section 20, &
Section 21. See the Appendix(es) A-G for a detailed explanation of the test results.

Page -27-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

APPENDIX A

RTCA/DO-160D

SECTION 16

Power Input

Page -28-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

1.0 PURPOSE OF THE TEST:

This test defines the test procedures for the electrical input power applied to the terminals of the
equipment under test.

2.0 EQUIPMENT CATEGORIES:

The Ruggadized 9 Pole Switching Multiplexer was subjected to Category E.

When equipment requires only AC input power and is tested to the AC input parameters, the
equipment is identified as Category E.

Page -29-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

3.0 TEST SETUP AND APPARATUS:

The AC Voltage Surge test set up as shown in Figure 16-3 is shown below:

Page -30-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

4.0 TEST PROCEDURE:

For AC Normal Operating Conditions:

For voltage and frequency, single phase equipment was operated according to the test procedures in
paragraph 16.5.1.1b. The equipment was operated at a maximum duty cycle for at least 30 minutes
with the primary power adjusted to 122 Vrms at 420 Hz. The voltage was then decrease to 100 Vrms
at 380 Hz with the duty cycle set at the maximum for 30 minutes.

For voltage and frequency, single phase emergency electrical system equipment was operated at
maximum duty cycle for 30 minutes with the primary power adjusted to 100 Vrms at 360 Hz. Then
the test was repeated with voltage adjusted to 122 Vrms at 360 Hz for 30 minutes. The test was then
set up with the voltage adjusted to 122 Vrms at 440 Hz with a maximum duty cycle for at least 30
minutes. After 30 minutes the voltage was decreased to 100 Vrms at 440 Hz with a maximum duty
cycle

Page -31-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

4.0 TEST PROCEDURE (CON'T):

For voltage and frequency, three phase equipment was operated according to the test procedures in
paragraph 16.5.1.1c. The equipment was operated at a maximum duty cycle for at least 30 minutes with the
primary power adjusted to 120.5 Vrms at 420 Hz. The voltage was then decrease to 101.5 Vrms at 380 Hz
with the duty cycle set at the maximum for 30 minutes.

For voltage and frequency, three phase emergency electrical system equipment was operated at
maximum duty cycle for 30 minutes with the primary power adjusted to 101.5 Vrms at 360 Hz. Then
the test was repeated with voltage adjusted to 120.5 Vrms at 360 Hz for 30 minutes. The test was
then set up with the voltage adjusted to 120.5 Vrms at 440 Hz with a maximum duty cycle for at
least 30 minutes. After 30 minutes the voltage was decreased to 101.5 Vrms at 440 Hz with a
maximum duty cycle

For voltage modulation, the equipment under test was operated according to the test procedures in paragraph
16.5.1.2 using the limits from Figure 16-1, the modulation envelope was applied for two minutes with the
voltage modulation set at 3.5 volts maximum peak-to-valley difference between the minimum and the
maximum voltage.

For frequency modulation, the equipment under test was operated according to the test procedures in
paragraph 16.5.1.3 defined by Figure 16-2, the modulation envelope was within the narrow frequency limits
and occurs as a result of speed variations in a generator coupling and drive speed regulation. The variations
of the primary system frequency, due to frequency modulation during any two-minute period was within a
band about the mean frequency as shown in Figure 16-2.

For momentary power interruptions, the equipment under test was operated according to the test procedures
in paragraph 16.5.1.4 using the test conditions from Table 16-1. The equipment under test was fully
operational with the nominal voltage and frequency applied prior to each test condition. The test conditions
from Table 16-1 was repeated twice for each operating mode of the equipment.

For normal Surge Voltage (AC), the equipment was set up as shown in Paragraph 16.5.1.5, Figure
16-3. The equipment under test was operated at a voltage 115V rms ±1 Vrms for five minutes. The
voltage is then cycled three times from 115 Vrms to 160 Vrms ±2Vrms for 30 minutes, returning the
voltage to 115 Vrms for five seconds. Then the voltage is decrease to 60 Vrms.

Page -32-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

5.0 LIMITS & RESULTS:

5.1 LIMITS:

For AC:

The frequency components of the voltage modulation envelope waveform does not exceed
the limits of Figure 16-1. The equipment was subjected to the above test conditions and
operates within the applicable equipment performance standards.

FIGURE 16-1 Frequency Characteristics of AC Voltage Modulation Envelope

Page -33-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

5.1 LIMITS (CON'T):

The variations of primary system frequency due to the frequency modulation does remain
within a band about the mean frequency defined by Figure 16-2.

FIGURE 16-2 Characteristics of AC Frequency Modulation

Page -34-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

5.1 LIMITS (CON'T):

The envelope of equipment step function of AC voltage surges does remain within the limits
defined by Figure 16-5.

FIGURE 16-5 Envelope of Equlvalent Step Functions of AC Voltage Surges

Page -35-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

5.1 LIMITS (CON'T):

The test conditions in Table 16-1 was applied twice to each operating mode of the equipment
under test.

TABLE 16-1 Test Conditions for Equipment with Digital Circuits

Page -36-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

5.0 LIMITS & RESULTS: (CON’T)

5.2 RESULTS:

There were no problems found during testing.

Page -37-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 16

POWER INPUT TEST DATA SHEET(S)

Page -38-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Test Report RTCA/DO-160D


Report Name: RTCA/DO-160D Immunity Test Report
Report print date: 04-06-2004 16:06:37
Program version: AC Source GUI32 ,version: 1.18 - Apr 18, 2003
AC or DC Source information:: Model = 3001iX, Serial no.= 53237

RTCA/D-160D Test Result: USER ABORT


Time test started: Tuesday, April 06, 2004 1:05:04 PM
Time test completed: Tuesday, April 06, 2004 4:05:52 PM
Test File:
Selected test type: AC Frequency and Voltage test Test site: Lab S
Test operator: DLS Electronic Systems
EUT description: Cytec RS/8-S Mainframe
User comments: Category E
Test Conditions:
Nominal Voltage (Un): 115.0 V AC Ambient Temp: 72 F
Nominal Frequency: 400.0 Hz Humidity: 40 %
Phase or output selection: A Pressure:
Standard Revision: RTCA Group: N/A
Test Options:

Normal State Test Options

Voltage and Frequency Minimum: SELECTED


Voltage and Frequency Maximum: SELECTED

Emergency Test Options

Voltage and Frequency Minimum: SELECTED


Voltage and Frequency Maximum: SELECTED

User observations regarding this EUT:


Observations: No Responses

Page -39-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Test Report RTCA/DO-160D


Report Name: RTCA/DO-160D Immunity Test Report
Report print date: 04-06-2004 16:21:39
Program version: AC Source GUI32 ,version: 1.18 - Apr 18, 2003
AC or DC Source information:: Model = 3001iX, Serial no.= 53237

RTCA/D-160D Test Result: USER ABORT


Time test started: Tuesday, April 06, 2004 4:10:30 PM
Time test completed: Tuesday, April 06, 2004 4:20:02 PM
Test File:
Selected test type: AC Frequency and Voltage test Test site: Lab S
Test operator: DLS Electronic Systems
EUT description: Cytec RS/8-S Mainframe
User comments: Category E
Test Conditions:
Nominal Voltage (Un): 115.0 V AC Ambient Temp: 72 F
Nominal Frequency: 400.0 Hz Humidity: 40 %
Phase or output selection: A Pressure:
Standard Revision: RTCA Group: N/A
Test Options:

Normal State Test Options

Frequency Modulation Level = 0.014: SELECTED


Voltage Modulation Depth = 1.0: SELECTED
Voltage Surge: SELECTED

User observations regarding this EUT:


Observations: No Responses

Page -40-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Test Report RTCA/DO-160D


Report Name: RTCA/DO-160D Immunity Test Report
Report print date: 04-07-2004 08:50:31
Program version: AC Source GUI32 ,version: 1.18 - Apr 18, 2003
AC or DC Source information:: Model = 3001iX, Serial no.= 53237

RTCA/D-160D Test Result: COMPLETED


Time test started: Wednesday, April 07, 2004 8:43:44 AM
Time test completed: Wednesday, April 07, 2004 8:47:49 AM
Test File:
Selected test type: AC Frequency and Voltage test Test site: Lab S
Test operator: DLS Electronic Systems
EUT description: Cytec RS/8-S Mainframe
User comments: Category E
Test Conditions:
Nominal Voltage (Un): 115.0 V AC Ambient Temp: 71F
Nominal Frequency: 400.0 Hz Humidity: 40 %
Phase or output selection: A Pressure:
Standard Revision: RTCA Group: N/A
Test Options:

Normal State Test Options

Power Interruption # 1, Repeat= 2: SELECTED


Power Interruption # 2, Repeat= 2: SELECTED
Power Interruption # 3, Repeat= 2: SELECTED
Power Interruption # 4, Repeat= 2: SELECTED
Power Interruption # 5, Repeat= 2: SELECTED
Power Interruption # 6, Repeat= 2: SELECTED
Power Interruption # 7, Repeat= 2: SELECTED
Power Interruption # 9, Repeat= 2: SELECTED
Power Interruption # 10, Repeat= 2: SELECTED
Power Interruption # 11, Repeat= 2: SELECTED
Power Interruption # 12, Repeat= 2: SELECTED
Power Interruption # 13, Repeat= 2: SELECTED
Power Interruption # 14, Repeat= 2: SELECTED

User observations regarding this EUT:


Observations: No Responses

Page -41-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Test Report RTCA/DO-160D


Report Name: RTCA/DO-160D Immunity Test Report
Report print date: 04-07-2004 09:24:00
Program version: AC Source GUI32 ,version: 1.18 - Apr 18, 2003
AC or DC Source information:: Model = 3001iX, Serial no.= 53237

RTCA/D-160D Test Result: USER ABORT


Time test started: Wednesday, April 07, 2004 9:11:14 AM
Time test completed: Wednesday, April 07, 2004 9:22:01 AM
Test File:
Selected test type: AC Frequency and Voltage test Test site: Lab S
Test operator: DLS Electronic Systems
EUT description: Cytec RS/8-S Mainframe
User comments: Category E
Test Conditions:
Nominal Voltage (Un): 115.0 V AC Ambient Temp: 71 F
Nominal Frequency: 400.0 Hz Humidity: 40 %
Phase or output selection: A Pressure:
Standard Revision: RTCA Group: N/A
Test Options:

Abnormal State Test Options

Voltage Minimum: SELECTED


Voltage Maximum: SELECTED
Voltage Drop: SELECTED
Voltage Surge: SELECTED

User observations regarding this EUT:


Observations: No Responses

Page -42-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 PHOTOS TAKEN DURING TESTING:

Page -43-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SECTION 16

TEST INSTRUMENTATION

TABLE 1

Model Serial Cal Cal Due


Description Manufacturer Number Number Range On Dates
Oscilloscope Hewlett 54845A US3845 1.5 GHz 8/22/03 8/22/04
Packard 0334 8G Samples/sec
Programmable California 3001ix 53237 3kVA 3/03/04 03/03/05
Power Supply Instruments

All primary equipment is calibrated against known reference standards with a verified traceable path NIST.

Page -44-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

APPENDIX B

RTCA/DO-160D

SECTION 17

Voltage Spike

Page -45-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

1.0 PURPOSE OF THE TEST:

This test determines whether the equipment can withstand the effects of voltage spikes arriving at
the equipment on its power leads, either AC or DC. The main adverse effects to be anticipated are:

a. Permanent damage, component failure, insulation breakdown.

b. Susceptibility degradation, or changes in equipment performance.

2.0 EQUIPMENT CATEGORIES:

The Ruggadized 9 Pole Switching Multiplexer was subjected to Category A.

Category A

Equipment intended primarily for installation where a high degree of protection against damage by
voltage spikes is required is identified as Category A.

Page -46-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

3.0 TEST SETUP AND APPARATUS:

The transient generator used produced the waveform shown in Figure 17-1 of the test specification.
A typical test setup is shown in Figure 17-2. Any method of generating the spike may be used if the
waveform complies with Figure 17-1. The generator was inserted in series with the Ruggadized 9
Pole Switching Multiplexer.

Page -47-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

4.0 TEST PROCEDURE:

With the equipment under test disconnected, the transient wave shape was verified to be within
specification. The Ruggadized 9 Pole Switching Multiplexer was set to its designated voltage. A
series of positive and negative spikes (described in Figure 17-1 of the Standard) were injected to
each of the primary inputs of the equipment under test. A minimum of 50 transients of each polarity
were injected within a period of one minute. The test was repeated for each operating mode or
function of the equipment.

In order to thoroughly test AC power lines, the pulse positioning function of the Spike Generator
was used. The generator was connected to the same 400 Hz power source as the power input line
under test in order to sync to the line. Using the Pulse Position Control in conjunction with the
Polarity Reversing Switch, the spike was injected through the entire 360° of the sine wave. The
generator injects at a rate of 6.2 pulses per second when set to sync to 400 Hz lines, resulting in
372 pulses in 60 seconds.

Page -48-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

5.0 LIMITS & RESULTS:

5.1 LIMITS:

A following Voltage Spike Waveform was used for the test:

FIGURE 17-1

5.2 RESULTS:

The AC Power Line was tested with no problems found at these levels.

Page -49-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160C

Section 17

POWER LEADS TESTED FOR VOLTAGE SPIKE

TEST CHECK OFF SHEET(S)

Page -50-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Company: Cytec EUT: RS/8-S Mainframe


Date: 4/6/04 Engineer: JDB
Voltage: 115VAC, 400Hz Category: A

Calibration: Record the generator setting required to reach the OC limit


Test: Apply at least 50 pulses in one minute.
60Hz lines: 450 ppm. 400Hz lines: 372 ppm
Results: Record any susceptibility noted and the threshold level or enter "None"

Lead: 115VAC, 400Hz Generator Setting: 490 Positive, 490 Negative


Polarity Limit (Vp) Pulses Applied/min. Susceptibility/ Threshold
Positive 600 372/1 None
Negative -600 372/1 None

Page -51-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160C

Section 17

VOLTAGE SPIKE CALIBRATION DATA SHEET(S)

Page -52-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Category A Positive Td (Duration)

Page -53-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Category A Negative Td (Duration)

Page -54-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Category A Positive Tr (Rise Time)

Page -55-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Category A Negative Tr (Rise Time)

Page -56-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Category A Positive (Impedance)

Page -57-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Category A Negative (Impedance)

Page -58-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160C

Section 17

VOLTAGE SPIKE TEST DATA SHEET(S)

Page -59-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Category A Positive 115 Vac, 400 Hz (Hot Lead)

Page -60-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Category A Negative 115 Vac, 400 Hz (Hot Lead)

Page -61-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 VOLTAGE SPIKE PHOTOS TAKEN DURING TESTING

CALIBRATION

Page -62-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 VOLTAGE SPIKE PHOTOS TAKEN DURING TESTING (CON’T)

IMPEDANCE VERIFICATION

Page -63-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 VOLTAGE SPIKE PHOTOS TAKEN DURING TESTING (CON’T)

115 Vac TEST

Page -64-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SECTION 17

TEST INSTRUMENTATION

TABLE 1

Model Serial Cal Cal Due


Description Manufacturer Number Number Range On Dates
Oscilloscope Hewlett 54845A US3845 1.5 GHz 7/29/03 7/29/04
Packard 0334 8G
Samples/sec
Oscilloscope Agilent 10076A N/A 100:1 7/29/03 7/29/04
Probe 66.7 Meg
Ohms/3pF

All primary equipment is calibrated against known reference standards with a verified traceable path NIST.

Page -65-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SECTION 17

TEST EQUIPMENT

TABLE 2

Model Serial
Description Manufacturer Number Number Range
Spike Generator Solar 7054-1 980705 2x10us
600V
Pulse Solar 2201-1 DLS# 2x10us
Transformer 000386 600V
Capacitor DLS JSU23X NA 10 uF
230V
Isolation Hammond 171E DLS# 115 Vac
Transformer 000396
Resistor DLS DLS50 N/A 50 Ohms
Assembly ½ Watt

Page -66-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

APPENDIX C

RTCA/DO-160D

SECTION 18

Audio Frequency Conducted Susceptibility –


Power Inputs

Page -67-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

1.0 PURPOSE OF THE TEST:

This test determines whether the equipment will accept frequency components of a magnitude
normally expected when the equipment is installed in the aircraft. These frequency components are
normally harmonically related to the power source fundamental frequency.

2.0 EQUIPMENT CATEGORIES:

The Ruggadized 9 Pole Switching Multiplexer was subjected to Category E.

When equipment requires only AC input power and is tested to the AC input parameters, the
equipment is identified as Category E.

Page -68-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

3.0 TEST SETUP AND APPARATUS:

The test was set up as shown in Figure 18-1 shown below.

Page -69-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

4.0 TEST PROCEDURE:

For AC:

The equipment was set up as shown in Figure 18-1, Paragraph 3.0. A sine wave audio frequency
signal was applied successively in series with each ungrounded AC input power lead. The frequency
of the applied signal was varied between 750 Hz and 15 kHz.

Page -70-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

5.0 LIMITS & RESULTS:

5.1 LIMITS:

The amount of voltage injected over the frequency range is shown below:

For AC:

The rms amplitude of the signal was maintained at not less than five percent of the nominal
AC input voltage. While injecting the signal, compliance with the standard was determined.

5.2 RESULTS:

The AC Power Line was tested with no problems found at this level.

Page -71-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 18

AUDIO FREQUENCY TEST CHECK OFF SHEET(S)

Page -72-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Company: Cytec EUT: RS/8-S Mainframe Power Lead: 115VAC, 400Hz


Engineer: JDB Cal Date: 4/3/04 Test Date: 4/7/04 Z Ver. Date: 11/14/03
Calibration: Record the generator setting required to reach 4.24Vrms across .6-Ohms (30W.)
Results: Record any susceptibility noted and the threshold level (Vp-p) or enter "None."
List any additional ranges and thresholds of susceptibility noted throughout the sweep.

Freq(Hz) 30W Cal - Gen Setting 115VACLimit (Vp-p) Level Applied (Vp-p) Suscept./Threshold 30W (Y or N)
750 20.05 16.3 16.3 None N
800 19.99 16.3 16.3 None N
900 19.98 16.3 16.3 None N
1000 19.88 16.3 16.3 None N
2000 19.84 16.3 16.3 None N
3000 19.69 16.3 16.3 None N
4000 19.63 16.3 16.3 None N
5000 19.61 16.3 16.3 None N
6000 19.63 16.3 16.3 None N
7000 19.75 16.3 16.3 None N
8000 19.65 16.3 16.3 None N
9000 19.65 16.3 16.3 None N
10000 19.64 16.3 16.3 None N
11000 19.76 16.3 16.3 None N
12000 19.62 16.3 16.3 None N
13000 19.78 16.3 16.3 None N
14000 19.75 16.3 16.3 None N
15000 19.85 16.3 16.3 None N

Page -73-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 18

AUDIO FREQUENCY CALIBRATION DATA SHEET(S)

Page -74-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CALIBRATION
4.24 VOLTS ACROSS .6 OHMS = 30 WATTS

Page -75-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 18

AUDIO FREQUENCY TEST DATA SHEET(S)

Page -76-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

115 Vac, 400 Hz (Hot Lead)

Page -77-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 AUDIO FREQUENCY POWER INPUTS PHOTOS TAKEN DURING TESTING:

AUDIO FREQUENCY CONDUCTED SUSCEPTIBILITY


CALIBRATION

Page -78-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 AUDIO FREQUENCY POWER INPUTS PHOTOS TAKEN DURING TESTING: (CON’T)

115 Vac TEST

Page -79-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SECTION 18

TEST INSTRUMENTATION

TABLE 1

Model Serial Cal Cal Due


Description Manufacturer Number Number Range On Dates
Oscilloscope Hewlett 54845A US3845 1.5 GHz 7/29/03 7/29/04
Packard 0334 8G Samples/sec
Oscilloscope Agilent 10076A N/A 100:1 7/29/03 7/29/04
Probe 66.7 Meg
Ohms/3pF
Power Sweep Solar 8850-1 004311 .03 – 10/25/03 10/25/04
Generator 100 kHz

All primary equipment is calibrated against known reference standards with a verified traceable path NIST.

Page -80-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SECTION 18

TEST EQUIPMENT

TABLE 2

Model Serial
Description Manufacturer Number Number Range
Audio Isolation Solar 6220-1A DLS# 10 Hz – 250 kHz
Transformer 000392
Power Isolation Hammond 171E DLS# 115v, 50/60 Hz
Transformer Manufacturing 000396
Calibration/ DLS CSVR 0506 DLS# .6 Ohms
Impedance 000711
Verification
Resistor
Power DLS RA18 DLS# 200 Hz – 150 kHz
Resistor 000707
Assembly
Capacitor Mallory SPU25Z106 N/A 10 uF
AQSD
Digital Multi- Wavetek 2005 000707435 DC – 1 kHz
Meter

Page -81-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

APPENDIX D

RTCA/DO-160D

SECTION 19

Induced Signal Susceptibility

Page -82-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

1.0 PURPOSE OF THE TEST

This test determines whether the equipment interconnect circuit configuration will accept a level of
induced voltages caused by the installation environment. This section relates specifically to
interfering signals related to the power frequency and its harmonics, audio frequency signals, and
electrical transients that are generated by other on-board equipment or systems and coupled to
sensitive circuits within the EUT through its interconnecting wiring.

2.0 EQUIPMENT CATEGORIES

The Ruggadized 9 Pole Switching Multiplexer was subjected to Category C.

Category C

Equipment intended primarily for operation in systems where interference-free operation is required
and where severe coupling occurs due to long wire runs or minimum wire separation is identified as
Category C.

Page -83-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

3.0 TEST SETUP AND APPARATUS:

This section consists of four different configurations: 1) Magnetic Fields Induced Into the
Equipment; 2) Magnetic Fields Induced into Interconnecting Cables; 3) Electric Fields Induced into
Interconnecting Cables; and 4) Spikes Induced into Interconnecting Cables.

The Magnetic Field induced into the equipment consisted of a straight wire radiator located within
0.15m of the periphery of the equipment under test. The field generated is shown in Table 19-1.

Paragraph Test Category Z Category A Category B Category C


19.3.1 Magnetic fields 20 A rms at 400 20 A rms at 400 Hz 20 A rms at 400 Hz 20 A rms at 400 Hz
induced into the Hz
equipment

19.3.2 Magnetic fields I x L = 30 A-m at I x L – 18 A-m Not applicable I x L – 120 A-m from
induced into 400 Hz reducing from 380 to 420 Hz 380 to 420 Hz, and 60
interconnecting to 0.8 A-m at 15 A-m at 400 Hz
cables kHz (as shown in reducing to 1.6 A-m at
Figure 19-1(a)) 15 kHz (as shown in
Figure 19-1(a))

19.3.3 Electric fields V x L –1800 V-m V x L – 360 V-m Not applicable V x L – 5400 V-m
induced into from 380 to 420 from 380 to 420 Hz from 380 to 420 Hz,
interconnecting Hz and 5400 V-m at 400
cables Hz reducing to 135
V-m at 15 kHz (as
shown in Figure
19-1(b))

19.3.4 Spikes Figure 19-4 Figure 19-4 Figure 19-4 Figure 19-4
induced into L = 3.0m L = 3.0m L = 1.2m L = 3.0m
interconnecting
cables

Table 19-1

Page -84-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

3.0 TEST SETUP AND APPARATUS (CON’T):

The cable magnetic field setup is shown in Figure 19-2:

Page -85-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

3.0 TEST SETUP AND APPARATUS (CON’T):

The cable electric field setup is shown in Figure 19-3:

Page -86-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

3.0 TEST SETUP AND APPARATUS (CON’T):

The cable voltage splice setup is shown in Figure 19-4:

Page -87-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

4.0 TEST PROCEDURE:

Magnetic Fields Induced Into the Equipment


The equipment under test was subjected to an audio frequency magnetic field, generated by
the current specified in Figure 19-1. A straight wire radiator was located within 0.15m of
the periphery of the unit of the equipment under test. The radiator was oriented on each
surface of the EUT and extended a minimum of 0.6m beyond each extremity of the EUT.
Each unit was tested individually.

Magnetic Fields Induced Into Interconnecting Cables


Each wire bundle was subjected to an audio frequency magnetic field as illustrated in
Figure 19-2. Each bundle was tested individually.

Electric Fields Induced Into Interconnecting Cables


Each wire bundle was subjected to an audio frequency electric field as illustrated in
Figure 19-3. Each bundle was tested individually.

Spikes Induced Into Interconnecting Cables.


Each wire bundle was subjected to transient fields using the test setup shown in Figure 19-4.
Both positive and negative fields were injected on each cable bundle individually.

Page -88-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

5.0 LIMITS & RESULTS:

5.1 LIMITS:
The Audio Frequency Magnetic Fields are shown in Figure 19-1(a) using Category C:

The Audio Frequency Electric Fields are shown in Figure 19-1(b) using Category C:

Page -89-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

5.0 LIMITS & RESULTS (CON’T):

5.1 LIMITS:

The Voltage Spike limits are shown in Figure 19-5:

5.2 RESULTS:

The AC Power Line was tested with no problems found at this level.

Page -90-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Sections 19.3.1, 19.3.2, 19.3.3, &


19.3.4

CHECK OFF SHEET(S)

Page -91-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Company: Cytec EUT: RS/8-S Mainframe


Date: 4/3/04 Engineer: JDB

Test: 20Arms at 400Hz for all categories (Z, A, B and C)


Results: Record any susceptibility noted and the threshold level or enter "None"

EUT EUT Surface Limit (Arms) Measured (Arms) Susceptibility/ Threshold


Top 20 20 None
Front 20 20 None
Left 20 20 None
Right 20 20 None
Back 20 20 None

Section 19.3.1

Page -92-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Company: Cytec EUT: RS/8-S Mainframe


Date: 4/5/04 Engineer: TD
Cable Bundle Under Test: Control Radiator Wire Length (m) 3.0

Results: Record any susceptibility noted and the threshold level or enter "None"
List any additional ranges and thresholds of susceptibility noted throughout the sweep

Freq. (kHz) Limit (Arms-m) Limit for 3m (Arms) Measured I (Arms) Susceptibility/Threshold
0.38 120 40 40 None
0.39 120 40 40 None
0.4 120 40 40 None
0.41 120 40 40 None
0.42 120 40 40 None

0.40 60 20.0 20.0 None


0.57 42.4 14.1 14.1 None
0.80 30.0 10.0 10.0 None
1.13 21.2 7.1 7.1 None
1.60 15.0 5.0 5.0 None
2.26 10.6 3.5 3.5 None
3.20 7.6 2.5 2.5 None
4.53 5.4 1.80 1.80 None
6.40 3.8 1.27 1.27 None
9.05 2.6 0.87 0.87 None
12.80 1.8 0.60 0.60 None
15.00 1.6 0.53 0.53 None

Section 19.3.2
CONTROL

Page -93-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Company: Cytec EUT: RS/8-S Mainframe


Date: 4/5/04 Engineer: TD
Cable Bundle Under Test: 0 Out Radiator Wire Length (m) 3.0

Results: Record any susceptibility noted and the threshold level or enter "None"
List any additional ranges and thresholds of susceptibility noted throughout the sweep

Freq. (kHz) Limit (Arms-m) Limit for 3m (Arms) Measured I (Arms) Susceptibility/Threshold
0.38 120 40 40 None
0.39 120 40 40 None
0.4 120 40 40 None
0.41 120 40 40 None
0.42 120 40 40 None

0.40 60 20.0 20.0 None


0.57 42.4 14.1 14.1 None
0.80 30.0 10.0 10.0 None
1.13 21.2 7.1 7.1 None
1.60 15.0 5.0 5.0 None
2.26 10.6 3.5 3.5 None
3.20 7.6 2.5 2.5 None
4.53 5.4 1.80 1.80 None
6.40 3.8 1.27 1.27 None
9.05 2.6 0.87 0.87 None
12.80 1.8 0.60 0.60 None
15.00 1.6 0.53 0.53 None

Section 19.3.2
O Output

Page -94-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Company: Cytec EUT: RS/8-S Mainframe


Date: 4/5/04 Engineer: TD
Cable Bundle Under Test: Signal I/O Radiator Wire Length (m) 3.0

Results: Record any susceptibility noted and the threshold level or enter "None"
List any additional ranges and thresholds of susceptibility noted throughout the sweep

Freq. (kHz) Limit (Arms-m) Limit for 3m (Arms) Measured I (Arms) Susceptibility/Threshold
0.38 120 40 40 None
0.39 120 40 40 None
0.4 120 40 40 None
0.41 120 40 40 None
0.42 120 40 40 None

0.40 60 20.0 20.0 None


0.57 42.4 14.1 14.1 None
0.80 30.0 10.0 10.0 None
1.13 21.2 7.1 7.1 None
1.60 15.0 5.0 5.0 None
2.26 10.6 3.5 3.5 None
3.20 7.6 2.5 2.5 None
4.53 5.4 1.80 1.80 None
6.40 3.8 1.27 1.27 None
9.05 2.6 0.87 0.87 None
12.80 1.8 0.60 0.60 None
15.00 1.6 0.53 0.53 None

Section 19.3.2
SIGNAL I/O

Page -95-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Company: Cytec EUT: RS/8-S Mainframe


Date: 4/5/04 Engineer: TD
Cable Bundle Under Test: Control Radiator Wire Length (m): 3.0

Results: Record any susceptibility noted and the threshold level or enter "None"
List any additional ranges and thresholds of susceptibility noted throughout the sweep

Freq. (kHz) Limit (Vrms-m) Limit for 3m (Vrms) Measured V (Vrms) Susceptibility/Threshold
0.38 5400 1800 1800
0.39 5400 1800 1800
0.40 5400 1800 1800
0.41 5400 1800 1800
0.42 5400 1800 1800

0.40 5400 1800 1800


0.50 4305 1435 1435
0.60 3577 1192 1192
0.70 3055 1018 1018
0.80 2667 889 889
0.90 2366 789 789
1 2126 709 709
2 1050 350 350
3 695 232 232
4 518 173 173
5 413 138 138
6 343 114 114
7 293 97.7 97.7
8 256 85.3 85.3
9 227 75.7 75.7
10 204 68.0 68.0
11 185 61.7 61.7
12 169 56.3 56.3
13 156 52.0 52.0
14 145 48.3 48.3
15 135 45.0 45.0

Section 19.3.3
CONTROL

Page -96-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Company: Cytec EUT: RS/8-S Mainframe


Date: 4/5/04 Engineer: TD
Cable Bundle Under Test: 0 Output Radiator Wire Length (m): 3.0

Results: Record any susceptibility noted and the threshold level or enter "None"
List any additional ranges and thresholds of susceptibility noted throughout the sweep

Freq. (kHz) Limit (Vrms-m) Limit for 3m (Vrms) Measured V (Vrms) Susceptibility/Threshold
0.38 5400 1800 1800
0.39 5400 1800 1800
0.40 5400 1800 1800
0.41 5400 1800 1800
0.42 5400 1800 1800

0.40 5400 1800 1800


0.50 4305 1435 1435
0.60 3577 1192 1192
0.70 3055 1018 1018
0.80 2667 889 889
0.90 2366 789 789
1 2126 709 709
2 1050 350 350
3 695 232 232
4 518 173 173
5 413 138 138
6 343 114 114
7 293 97.7 97.7
8 256 85.3 85.3
9 227 75.7 75.7
10 204 68.0 68.0
11 185 61.7 61.7
12 169 56.3 56.3
13 156 52.0 52.0
14 145 48.3 48.3
15 135 45.0 45.0

Section 19.3.3
O Output

Page -97-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Company: Cytec EUT: RS/8-S Mainframe


Date: 4/5/04 Engineer: TD
Cable Bundle Under Test: Signal I/O Radiator Wire Length (m): 3.0

Results: Record any susceptibility noted and the threshold level or enter "None"
List any additional ranges and thresholds of susceptibility noted throughout the sweep

Freq. (kHz) Limit (Vrms-m) Limit for 3m (Vrms) Measured V (Vrms) Susceptibility/Threshold
0.38 5400 1800 1800
0.39 5400 1800 1800
0.40 5400 1800 1800
0.41 5400 1800 1800
0.42 5400 1800 1800

0.40 5400 1800 1800


0.50 4305 1435 1435
0.60 3577 1192 1192
0.70 3055 1018 1018
0.80 2667 889 889
0.90 2366 789 789
1 2126 709 709
2 1050 350 350
3 695 232 232
4 518 173 173
5 413 138 138
6 343 114 114
7 293 97.7 97.7
8 256 85.3 85.3
9 227 75.7 75.7
10 204 68.0 68.0
11 185 61.7 61.7
12 169 56.3 56.3
13 156 52.0 52.0
14 145 48.3 48.3
15 135 45.0 45.0

Section 19.3.3
SIGNAL I/O

Page -98-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Cable Bundle Under Test: Control L - Radiator Wire Length (m): 3.0

Setup: L = 3.0m for Categories Z, A and C. L = 1.2m for Category B.

Positive Polarity
Spike Parameter Specification Applied
Voltage Spike Amplitude (Vp-p) >600 >600
Spike Repetition Period (microseconds) .2 to 10 1.3
Burst Duration (microseconds) 50 to 1000 270
Duration of Test (minutes) >2 2:10

Susceptibility Response: None

Negative Polarity
Spike Parameter Specification Applied
Voltage Spike Amplitude (Vp-p) >600 >600
Spike Repetition Period (microseconds) .2 to 10 1.8
Burst Duration (microseconds) 50 to 1000 238
Duration of Test (minutes) >2 2:10

Susceptibility Response: None

Section 19.3.4
CONTROL

Page -99-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Company: Cytec EUT: RS/8-S Mainframe Category: C


Date: 4/5/04 Engineer: TD
Cable Bundle Under Test: 0 Out L - Radiator Wire Length (m): 3.0

Setup: L = 3.0m for Categories Z, A and C. L = 1.2m for Category B.

Positive Polarity
Spike Parameter Specification Applied
Voltage Spike Amplitude (Vp-p) >600 >600
Spike Repetition Period (microseconds) .2 to 10 1.3
Burst Duration (microseconds) 50 to 1000 268
Duration of Test (minutes) >2 2:10

Susceptibility Response: None

Negative Polarity
Spike Parameter Specification Applied
Voltage Spike Amplitude (Vp-p) >600 >600
Spike Repetition Period (microseconds) .2 to 10 1.8
Burst Duration (microseconds) 50 to 1000 267
Duration of Test (minutes) >2 2:10

Susceptibility Response: None

Section 19.3.4
O OUTPUT

Page -100-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Company: Cytec EUT: RS/8-S Mainframe Category: C


Date: 4/5/04 Engineer: TD
Cable Bundle Under Test: Signal I/O L - Radiator Wire Length (m): 3.0

Setup: L = 3.0m for Categories Z, A and C. L = 1.2m for Category B.

Positive Polarity
Spike Parameter Specification Applied
Voltage Spike Amplitude (Vp-p) >600 >600
Spike Repetition Period (microseconds) .2 to 10 1.3
Burst Duration (microseconds) 50 to 1000 345
Duration of Test (minutes) >2 2:10

Susceptibility Response: None

Negative Polarity
Spike Parameter Specification Applied
Voltage Spike Amplitude (Vp-p) >600 >600
Spike Repetition Period (microseconds) .2 to 10 1.8
Burst Duration (microseconds) 50 to 1000 282
Duration of Test (minutes) >2 2:10

Susceptibility Response: None

Section 19.3.4
SIGNAL I/O

Page -101-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 19.3.1

Magnetic Fields Induced Into the Equipment

Page -102-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 19.3.1

INDUCED SIGNAL SUSCEPTIBILITY

TEST DATA SHEET(S)

Page -103-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CATEGORY C 20 Amps @ 400 Hz

Page -104-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 19.3.2

Magnetic Fields Induced Into Interconnecting Cables

Page -105-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 19.3.2

INDUCED SIGNAL SUSCEPTIBILITY

TEST DATA SHEET(S)

Page -106-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CONTROL CABLE

Page -107-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

O OUTPUT

Page -108-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SIGNAL I/O

Page -109-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 19.3.3

Electric Fields Induced Into Interconnecting Cables

Page -110-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 19.3.3

INDUCED SIGNAL SUSCEPTIBILITY

TEST DATA SHEET(S)

Page -111-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CONTROL CABLE

Page -112-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

O OUTPUT

Page -113-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SIGNAL I/O

Page -114-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 19.3.4

Spikes Induced Into Interconnecting Cables

Page -115-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 19.3.4

INDUCED SIGNAL SUSCEPTIBILITY

CALIBRATION DATA SHEET(S)

Page -116-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CALIBRATION
TOTAL DURATION POSITIVE

Page -117-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CALIBRATION
TOTAL DURATION NEGATIVE

Page -118-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CALIBRATION
REPETITION RATE POSITIVE

Page -119-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CALIBRATION
REPETITION RATE NEGATIVE

Page -120-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CALIBRATION
REPETITION PERIOD POSITIVE

Page -121-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CALIBRATION
REPETITION PERIOD NEGATIVE

Page -122-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CALIBRATION
DURATION AND AMP POSITIVE

Page -123-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CALIBRATION
DURATION AND AMP NEGATIVE

Page -124-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 19.3.4

INDUCED SIGNAL SUSCEPTIBILITY

TEST DATA SHEET(S)

Page -125-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CATEGORY C
POSITIVE
CONTROL

Page -126-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CATEGORY C
NEGATIVE
CONTROL

Page -127-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CATEGORY C
POSITIVE
O OUTPUT

Page -128-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CATEGORY C
NEGATIVE
O OUTPUT

Page -129-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CATEGORY C
POSITIVE
SIGNAL I/O

Page -130-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CATEGORY C
NEGATIVE
SIGNAL I/O

Page -131-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 INDUCED SIGNAL PHOTOS TAKEN DURING TESTING:

SECTION 19.3.1

Page -132-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 INDUCED SIGNAL PHOTOS TAKEN DURING TESTING: (CON’T)

SECTION 19.3.2
CONTROL

Page -133-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 INDUCED SIGNAL PHOTOS TAKEN DURING TESTING: (CON’T)

SECTION 19.3.2
O OUTPUT

Page -134-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 INDUCED SIGNAL PHOTOS TAKEN DURING TESTING: (CON’T)

SECTION 19.3.2
SIGNAL I/O

Page -135-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 INDUCED SIGNAL PHOTOS TAKEN DURING TESTING: (CON’T)

SECTION 19.3.3
CONTROL

Page -136-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 INDUCED SIGNAL PHOTOS TAKEN DURING TESTING: (CON’T)

SECTION 19.3.3
O OUTPUT

Page -137-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 INDUCED SIGNAL PHOTOS TAKEN DURING TESTING: (CON’T)

SECTION 19.3.3
SIGNAL I/O

Page -138-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 INDUCED SIGNAL PHOTOS TAKEN DURING TESTING: (CON’T)

SECTION 19.3.4
CALIBRATION

Page -139-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 INDUCED SIGNAL PHOTOS TAKEN DURING TESTING: (CON’T)

SECTION 19.3.4
CONTROL

Page -140-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 INDUCED SIGNAL PHOTOS TAKEN DURING TESTING: (CON’T)

SECTION 19.3.2
O OUTPUT

Page -141-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 INDUCED SIGNAL PHOTOS TAKEN DURING TESTING: (CON’T)

SECTION 19.3.4
SIGNAL I/O

Page -142-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

7.0 TEST INSTRUMENTATION

SECTION 19.3.1

MAGNETIC FIELDS INDUCED INTO THE EQUIPMENT

TABLE 1

Model Serial Cal Cal Due


Description Manufacturer Number Number Range On Dates
Oscilloscope Hewlett 54845A US3845 1.5 GHz 7/29/03 7/29/04
Packard 0334 8G
Samples/sec
Oscilloscope Agilent 1146A US40000 DC-100 kHz 9/18/03 9/18/04
AC/DC Current 559 0-70A rms
Probe
Power Sweep Solar 8850-1 004311 .03 - 100 kHz 10/24/03 10/24/04
Generator

All primary equipment is calibrated against known reference standards with a verified traceable path NIST.

Page -143-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

7.0 TEST EQUIPMENT

SECTION 19.3.1

MAGNETIC FIELDS INDUCED INTO THE EQUIPMENT

TABLE 2

Model Serial
Description Manufacturer Number Number Range
Current Hevi-Duty H522F3A DLS# 380 – 15 kHz
Step-Up 000397 20:1
Transformer
Straight Wire N/A N/A N/A AWG8
Radiator

All primary equipment is calibrated against known reference standards with a verified traceable path NIST.

Page -144-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

7.0 TEST INSTRUMENTATION

SECTION 19.3.2

MAGNETIC FIELDS INDUCED INTO INTERCONNECTING CABLES

TABLE 3

Model Serial Cal Cal Due


Description Manufacturer Number Number Range On Dates
Oscilloscope Hewlett 54845A US3845 1.5 GHz 7/29/03 7/29/04
Packard 0334 8G
Samples/sec
Oscilloscope Agilent 1146A US40000 DC-100 kHz 9/18/03 9/18/04
AC/DC 559 0-70A rms
Current Probe
Power Sweep Solar 8850-1 004311 .03 - 100 kHz 10/24/03 10/24/04
Generator

All primary equipment is calibrated against known reference standards with a verified traceable path NIST.

Page -145-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

7.0 TEST EQUIPMENT

SECTION 19.3.2

MAGNETIC FIELDS INDUCED INTO INTERCONNECTING CABLES

TABLE 4

Model Serial
Description Manufacturer Number Number Range
Current Hevi-Duty H522F3A DLS# 380 – 15 kHz
Step-Up 000397 20:1
Transformer
Magnetic Field N/A N/A N/A AWG8
Radiating Wire

Page -146-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

7.0 TEST INSTRUMENTATION

SECTION 19.3.3

ELECTRIC FIELDS INDUCED INTO INTERCONNECTING CABLES

TABLE 5

Model Serial Cal Cal Due


Description Manufacturer Number Number Range On Dates
Oscilloscope Hewlett 54845A US3845 1.5 GHz 7/29/03 7/29/04
Packard 0334 8G Samples/sec
Oscilloscope Tektronix P6015A B043743 1000x 7/29/03 7/29/04
Probe 20 kV
Power Sweep Solar 8850-1 004311 .03 - 100 kHz 10/24/03 10/24/04
Generator

All primary equipment is calibrated against known reference standards with a verified traceable path NIST.

Page -147-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

7.0 TEST EQUIPMENT

SECTION 19.3.3

ELECTRIC FIELDS INDUCTED INTO INTERCONNECTING CABLES

TABLE 6

Model Serial
Description Manufacturer Number Number Range
Audio Isolation Solar 6220-1A DLS# 10 Hz – 250 kHz
Transformer 000393
High Voltage Transco 4B15N3-02 DLS# 125:1
Transformer 000395
Impedance Solar 7033-1 DLS# 30 Hz – 150 kHz
Matching 000394
Transformer
Radiating Wire NA NA NA 3.5 meter AWG 24

Page -148-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

7.0 TEST INSTRUMENTATION

SECTION 19.3.4

SPIKES INDUCED INTO INTERCONNECTING CABLES

TABLE 7

Model Serial Cal Cal Due


Description Manufacturer Number Number Range On Dates
Oscilloscope Hewlett 54845A US3845 1.5 GHz 7/29/03 7/29/04
Packard 0334 8G
Samples/sec
Oscilloscope Agilent 10076A NA 100x 7/29/03 7/29/04
Probe 1kV
Power Sweep Solar 8850-1 004311 .03 – 10/24/03 10/24/04
Generator 100 kHz
Inductive DLS BL-1900 0001 N/A 4/5/04 4/5/05
Switching
Transient
Generator

All primary equipment is calibrated against known reference standards with a verified traceable path NIST.

Page -149-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

7.0 TEST EQUIPMENT

SECTION 19.3.4

SPIKES INDUCTED INTO INTERCONNECTING CABLES

TABLE 8

Description Manufacturer Model Serial Range


Number Number
Loop Radiating N/A N/A N/A AWG8
Wire

Page -150-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

APPENDIX E

RTCA/DO-160D

SECTION 20.4

Conducted Susceptibility
10 kHz – 400 MHz

Page -151-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

1.0 PURPOSE OF THE TEST:

This test determines whether the equipment under test will operate within performance specifications
when the equipment and its interconnecting wiring are exposed to a level of RF modulated power by
injection probe induction onto the power lines and interface circuit wiring.

From 10 kHz to 400 MHz, the equipment under test (EUT) is subjected to RF signals coupled by
means of injection probes into its cable bundles.

Equipment with special signal, frequency, modulation or bandpass characteristics may require test
variations as specified by the applicable performance standards.

The result of this test is to permit categories to be assigned defining the conducted and RF test levels
of the equipment. This test, along with the radiated susceptibility, is sufficient to obtain
environmental qualification for radio frequency susceptibility of the equipment. Additional tests may
be necessary to certify the installation of systems in an aircraft dependent on the functions performed.

Page -152-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

2.0 EQUIPMENT CATEGORIES:

Categories designate the RF test levels and establish the EUT minimum RF susceptibility level. The
categories may be given in the applicable equipment performance standard.

The category to be applied to a system or equipment frequently must be chosen before the internal RF
environment of the aircraft is known. Further, many systems or equipments are designed with the
intent that they will be installed in several different types of aircraft. Therefore, if a category is not
identified in the equipment specification, the equipment manufacturer should design, test and qualify
the equipment to the category level consistent with expected location, exposure and use.

Category designation for equipment consists of three characters. Conducted susceptibility test levels
are designated with the first category character. Continuous wave (CW) and square wave (SW)
modulated radiated susceptibility test levels are designated with the second category character. Pulse
modulated radiated susceptibility test levels are designated with the third category character.

To aid the equipment manufacturer in selecting appropriate test limits for the equipment and its
interconnecting wiring, categories have been defined below. The descriptions are for guidance only.
Equipment location, anticipated exposure and location of interconnecting wiring, aircraft size and
construction determine the test level.

The Ruggadized 9 Pole Switching Multiplexer was subjected to Category V.

Category V is intended for equipments and interconnecting wiring installed in a moderate


environment such as the more electromagnetically open areas of an aircraft composed principally of
metal.

Page -153-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

3.0 TEST SETUP AND APPARATUS:

The Ruggadized 9 Pole Switching Multiplexer is set up according to Figure 20-9 shown below. The
induced current monitor probe is installed 5cm from the EUT. If the EUT connector plus backshell
length exceeds 5cm, the probe shall be placed as close to the connector backshell as possible and the
position noted. Support and center the probe. Install the injection probe 5cm from the face of the
monitor probe.

Page -154-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

4.0 TEST PROCEDURE:

Proper probe locations, software installation, modes of operation and stability of the EUT, test
equipment and all monitoring circuits and loads were established.

CAUTION: RF fields can be hazardous. Observe appropriate RF exposure limits.

Set the signal generator to 10 kHz, unmodulated. Establish the forward power to the injection probe
on amplitude measurement instrument #2 at 10 kHz at the power determined in the probe calibration
procedure for the selected category of Figure 20-6. The frequency range was scanned slowly at the
proper forward power. Both CW and square wave modulation were applied. The RF carrier was
amplitude modulated with a 1 kHz square wave at greater than 90 percent depth, with optional 1 to 3
Hz superimposed. When modulation was applied, the peak amplitude complies with the definitions
of Figure 20-5.

Also consider applying other modulations associated with the EUT, such a clock, data, IF, internal
processing or modulation frequencies. Consider any possible low frequency response characteristic
of the EUT, for example, a flight control equipment's response to 1 to 3 Hz modulation in the 2 to 30
MHz HF range. When using 1 Hz to 3 Hz modulation, ensure that sweeping and/or frequency
stepping is suspended during the "off" period of the modulation. As an option, tests can be run using
only the modulation to which the EUT is most susceptible.

Slowly scan the frequency range to 400 MHz at the forward power amplitude using the proper probes
and modulations. Dwell at internal modulation, data or clock frequencies, as required.

Monitor the induced cable bundle current with the amplitude measurement instrument and data
recorder to capture resonances. When necessary, adjust and control the forward power to limit
induced current on the bundle:

Cat Y – 1 A;
Cat W – 500 mA;
Cat V – 250 mA;
Cat U and R – 100 mA;
Cat T – 25 mA
Cat S – 5 mA

While scanning, evaluate EUT operation and DETERMINE COMPLIANCE WITH APPLICABLE
EQUIPMENT PERFORMANCE STANDARDS.

Page -155-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Page -156-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

5.0 LIMITS & RESULTS:

5.1 LIMITS:

The Ruggadized 9 Pole Switching Multiplexer was subjected to Category V. The level is shown
below in Figure 20-6.

5.2 RESULTS:

The AC Power Line was tested with no problems found at this level.

Page -157-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 20.4

CONDUCTED SUSCEPTIBILITY

CALIBRATION AND TEST DATA SHEETS

Page -158-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

C Y T E C R S /8 -S M a in fra m e
S N 1 3 6 9 0 6 "A C C a b le " C W 0 4 -0 3 -0 4
1000

100

10

T e s t C u rre n t (m A )
C a lib ra tio n c u rre n t L im it (m A )
M a x im u m C u rre n t L im it (m A )
0 .1
10000 100000 1000000 10000000 100000000 1000000000
F re q u e n c y (H z)

C Y T E C R S /8 -S M a in fra m e
S N 1 3 6 9 0 6 "A C C a b le " C W 0 4 -0 3 -0 4
100

10

L a b S c a lib ra tio n fo rw a rd p o w e r le v e l (d B m )
1
10000 100000 1000000 10000000 100000000 1000000000
F re q u e n c y (H z)

Page -159-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

C Y T E C R S /8 -S M a in fr a m e
S N 1 3 6 9 0 6 " A C C a b le " C W 0 4 -0 3 -0 4
100

10

C a lib ra tio n le v e l (m A )
L a b S m e a s u re d c a lib ra tio n le v e l (m A )
1
10000 100000 1000000 10000000 100000000 1000000000
F r e q u e n c y (H z )

C Y T E C R S /8 -S M a in fra m e
S N 1 3 6 9 0 6 " A C C a b le " C W 0 4 -0 3 -0 4
1000

100

C a lib ra tio n L a b S L e v e ls (d B u V )
C a lib ra tio n L im it (d B u V )
10
10000 100000 1000000 10000000 100000000 1000000000
F re q u e n c y (H z )

Page -160-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CYTEC RS/8-S Mainframe


SN 136906 "AC Cable" CW 04-03-04
1000

100

Current Limit (dBuA)


Test Current (dBuA)
10
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

CYTEC RS/8-S Mainfram e


SN 136906 "AC Cable" CW 04-03-04
1000

100

10

Lab S Calibration Forward Power (mA)


Lab S Test Forward Power (mA)
1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

Page -161-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CYTEC RS/8-S Mainframe


SN 136906 "AC Cable" CW 04-03-04
100

10

Measured Forward Power (dBm)


Calibrated Forward Power (dBm)
1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

C Y T E C R S /8 -S M a in fra m e
S N 1 3 6 9 0 6 D 9 "0 " C W 0 4 -0 2 -0 4
1000

100

10

T est C urrent (m A )
C alibration current Lim it (m A )
M axim um C urrent Lim it (m A )
0.1
10000 100000 1000000 10000000 10000 0000 1000000000
F req u en cy (H z)

Page -162-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

C Y T E C R S /8 -S M a in fra m e
S N 1 3 6 9 0 6 D 9 "0 " C W 0 4 -0 2 -0 4
100

10

L a b S c a lib ra tio n fo rw a rd p o w e r le v e l (d B m )
1
1 0 0 00 1 0 0 00 0 1 00 0 00 0 1 0 0 00 0 00 1 00 0 00 0 0 0 1 00 0 00 0 0 00
F re q u e n c y (H z)

C Y T E C R S /8 -S M a in fra m e
S N 1 3 6 9 0 6 D 9 " 0 " C W 0 4 -0 2 -0 4
100

10

C a lib ra tio n le v e l (m A )
L a b S m e a s u re d c a lib ra tio n le v e l (m A )
1
10000 100000 1000000 10000000 100000000 1000000000
F re q u e n c y (H z )

Page -163-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

C Y T E C R S /8 -S M a in fra m e
S N 1 3 6 9 0 6 D 9 " 0 " C W 0 4 -0 2 -0 4
1000

100

C a lib ra tio n L a b S L e v e ls (d B u V )
C a lib ra tio n L im it (d B u V )
10
10000 100000 1000000 10000000 100000000 1000000000
F r e q u e n c y (H z )

CYTEC RS/8-S Mainframe


SN 136906 D9 "0" CW 04-02-04
1000

100

Current Limit (dBuA)


Test Current (dBuA)
10
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

Page -164-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CYTEC RS/8-S M ainfram e


SN 136906 D9 "0" CW 04-02-04
1000

100

10

Lab S calibration Forward Power (m A)


Lab S Test Forward Power (mA)
1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

CYTEC RS/8-S Mainframe


SN 136906 D9 "0" CW 04-02-04
100

10

Measured Forward Power (dBm)


Calibrated Forward Power (dBm)
1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

Page -165-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CYTEC RS/8-S M ainfram e


SN 136906 D9 "Signal I/O" CW 04-02-04
1000

100

10

1
Test Current (m A)
Calibration current Lim it (m A)
M axim um Current Lim it (m A)
0.1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

CYTEC R S/8-S M ainfram e


SN 136906 D9 "S ignal I/O " CW 04-02-04
100

10

Lab S calibration forw ard pow er level (dB m )


1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

Page -166-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

C Y T E C R S /8 -S M a in fra m e
S N 1 3 6 9 0 6 D 9 " S ig n a l I/O " C W 0 4 -0 2 -0 4
100

10

C a lib ra tio n le v e l (m A )
H S L a b S m e a s u re d c a lib ra tio n le v e l (m A )
1
10000 100000 1000000 10000000 100000000 1000000000
F re q u e n c y (H z )

C Y T E C R S /8 -S M a in fr a m e
S N 1 3 6 9 0 6 D 9 " S ig n a l I/O " C W 0 4 -0 2 -0 4
1000

100

C a lib ra tio n L a b S L e v e ls (d B u V )
C a lib ra tio n L im it (d B u V )
10
10000 100000 1000000 10000000 100000000 1000000000
F re q u e n c y (H z )

Page -167-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CYTEC RS/8-S M ainfr am e


SN 136906 D9 "Signal I/O" CW 04-02-04
1000
Amplitude (dBuA)

100

Current Lim it (dB uA )


Test Current (dB uA )
10
10000 100000 1000000 10000000 100000000 1000000000
Fr e que ncy (Hz)

CYTEC RS/8-S M ainfr am e


SN 136906 D9 "Signal I/O" CW 04-02-04
1000

100
Amplitude (mA)

10

Lab S calibration Forward Power (mA)


Lab S Test Forward Power (mA)
1
10000 100000 1000000 10000000 100000000 1000000000
Fr e que ncy (Hz)

Page -168-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CYTEC RS/8-S Mainframe


SN 136906 D9 "Signal I/O" CW 04-02-04
100

10

Measured Forward Power (dBm)


Calibrated Forward Power (dBm)
1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

CYTEC RS/8-S M ainfram e


SN 136906 D25 "Control Connector" C W 04-03-04
1000

100

10

1
Test C urrent (m A )
C alibration current Lim it (m A )
M axim um C urrent Lim it (m A )
0.1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

Page -169-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CYTEC RS /8 -S M a infr a m e
S N 1 3 6 9 0 6 D2 5 " Control Conne c tor" CW 0 4 -0 3 -0 4
100
Amplitude (dBm)

10

Lab S Calibration F orward P ower Level (dB m )


1
10000 100000 1000000 10000000 100000000 1000000000
Fr e q u e n cy (Hz )

C Y T E C R S /8 - S M a in f r a m e
SN 1 3 6 9 0 6 D 2 5 " C o n tr o l C o n n e c to r " C W 0 4 -0 3 -0 4
100
Amplitude (mA)

10

C a lib ra t io n le ve l (m A )
L a b S m e a s u re d c a lib ra t io n le ve l (m A )

1
10000 100000 1000000 10000000 100000000 1000000000
Fr e q u e n c y ( Hz )

Page -170-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

C YT EC R S /8 -S M a in fr a m e
S N 1 3 6 9 0 6 D 2 5 " C o n tr o l C o n n e c to r " C W 0 4 -0 3 -0 4
1000
Amplitude (dBuV)

100

C a lib ra t io n L a b S L e ve ls (d B u V )
C a lib ra t io n L im it (d B u V )
10
10000 100000 1000000 10000000 100000000 1000000000
Fr e q u e n c y ( Hz )
CYTEC RS/8-S M ainfr am e
SN 136906 D25 "Co ntr ol Con ne ctor " CW 04-03-04
1000
Amplitude (dBuA)

100

Current Lim it (dB uA )


Tes t Current (dB uA )
10
10000 100000 1000000 10000000 100000000 1000000000
Fr e que ncy (Hz )

Page -171-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CYTEC RS/8-S Mainframe


SN 136906 D25 "Control Connector" CW 04-03-04
1000

100

10

Lab S Calibration Forward Power (mA)


Lab S Test Forward Power (mA)
1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

CYTEC RS/8-S Mainframe


SN 136906 D25 "Control Connector" CW 04-03-04
100

10

Measured Forward Power (dBm)


Calibrated Forward Power (dBm)

1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

Page -172-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CYTEC RS/8-S Mainfram e


SN 136906 "AC Cable" SW 04-03-04
1000

100

10

1
Test Current (m A)
Calibration current Lim it (mA)
Maxim um Current Limit (mA)
0.1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

CYTEC RS/8-S M ainfram e


SN 136906 "AC Cable" SW 04-03-04
100

10

Lab S calibration forward power level (dBm )


1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

Page -173-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

C Y T E C R S /8 -S M a in fr a m e
S N 1 3 6 9 0 6 " A C C a b le " S W 0 4 -0 3 -0 4
100

10

C a lib ra tio n le v e l (m A )
L a b S m e a s u re d c a lib ra tio n le v e l (m A )
1
10000 100000 1000000 10000000 100000000 1000000000
F r e q u e n c y (H z )

C Y T E C R S /8 -S M a in fra m e
S N 1 3 6 9 0 6 " A C C a b le " S W 0 4 -0 3 -0 4
1000

100

C a lib ra tio n L a b S L e v e ls (d B u V )
C a lib ra tio n L im it (d B u V )
10
10000 100000 1000000 10000000 100000000 1000000000
F re q u e n c y (H z )

Page -174-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

C YTEC R S/8-S M ainfram e


SN 136906 "A C C able" SW 04-03-04
1000

100

C urrent Lim it (dB uA )


Test C urrent (dB uA )
10
10000 100000 1000000 10000000 100000000 1000000000
Frequency (H z)

CYTEC RS/8-S Mainframe


SN 136906 "AC Cable" SW 04-03-04
1000

100

10

Lab S Calibration Forward Power (mA)


Lab S Test Forward Power (mA)
1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

Page -175-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CYTEC RS/8-S Mainframe


SN 136906 "AC Cable" SW 04-03-04
100

10

Measured Forward Power (dBm)


Calibrated Forward Power (dBm)
1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

CYTEC RS/8-S M ainfram e


SN 136906 D9 "0" SW 04-02-04
1000

100

10

Test Current (m A)
Calibration current Lim it (m A)
M axim um Current Lim it (m A)
0.1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

Page -176-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

C YTEC R S/8-S M ainfram e


S N 136906 D 9 "0" SW 04-02-04
100

10

Lab S calibration forw ard pow er level (dB m )


1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (H z)

C Y T E C R S /8 -S M a in fra m e
S N 1 3 6 9 0 6 D 9 " 0 " S W 0 4 -0 2 -0 4
100

10

C a lib ra tio n le v e l (m A )
L a b S m e a s u re d c a lib ra tio n le v e l (m A )
1
10000 100000 1000000 10000000 100000000 1000000000
F re q u e n c y (H z )

Page -177-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

C Y T E C R S /8 -S M a in fra m e
S N 1 3 6 9 0 6 D 9 " 0 " S W 0 4 -0 2 -0 4
1000

100

C a lib ra tio n L a b S L e v e ls (d B u V )
C a lib ra tio n L im it (d B u V )
10
10000 100000 1000000 10000000 100000000 1000000000
F re q u e n c y (H z )

CYTEC RS/8-S Mainframe


SN 136906 D9 "0" SW 04-02-04
1000

100

Current Limit (dBuA)


Test Current (dBuA)
10
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

Page -178-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CYTEC RS/8-S Mainframe


SN 136906 D9 "0" SW 04-02-04
1000

100

10

Lab S calibration Forward Power (mA)


Lab S Test Forward Power (mA)
1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

CYTEC RS/8-S Mainframe


SN 136906 D9 "0" SW 04-02-04
100

10

Measured Forward Power (dBm)


Calibrated Forward Power (dBm)
1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

Page -179-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

C YTEC R S/8-S M ainfram e


SN 136906 D 9 "Signal I/O " SW 04-02-04
1000

100

10

Test C urrent (m A )
C alibration current Lim it (m A )
M axim um C urrent Lim it (m A )
0.1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

C Y T E C R S /8-S M a in fra m e
S N 13 6 90 6 D 9 "S ig n a l I/O " S W 04 -0 2-0 4
100

10

Lab S calibration forw ard pow er level (dB m )


1
10000 100000 1000000 10000000 100000000 1000000000
F req u en cy (H z)

Page -180-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

C Y T E C R S /8 -S M a in fra m e
S N 1 3 6 9 0 6 D 9 " S ig n a l I/O " S W 0 4 -0 2 -0 4
100

10

C a lib ra tio n le v e l (m A )
L a b S m e a s u re d c a lib ra tio n le v e l (m A )
1
10000 100000 1000000 10000000 100000000 1000000000
F re q u e n c y (H z)

C Y T E C R S /8 -S M a in fr a m e
S N 1 3 6 9 0 6 D 9 " S ig n a l I/O " S W 0 4 -0 2 -0 4
1000

100

C a lib ra tio n L a b S L e v e ls (d B u V )
C a lib ra tio n L im it (d B u V )
10
10000 100000 1000000 10000000 100000000 1000000000
F r e q u e n c y (H z )

Page -181-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CYTEC RS/8-S M ainfram e


SN 136906 D9 "Signal I/O" SW 04-02-04
1000

100

Current Lim it (dBuA)


Test Current (dBuA)
10
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

CYTEC RS/8-S Mainframe


SN 136906 D9 "Signal I/O" SW 04-02-04
1000

100

10

Lab S calibration Forward Power (mA)


Lab S Test Forward Power (mA)
1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

Page -182-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CYTEC RS/8-S Mainframe


SN 136906 D9 "Signal I/O" SW 04-02-04
100

10

Measured Forward Power (dBm)


Calibrated Forward Power (dBm)
1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

CYTEC RS/8-S M ainfram e


SN 136906 D25 "Control C onnector" SW 04-02-04
1000

100

10

1
Test C urrent (m A )
Calibration current Lim it (m A )
M axim um Current Lim it (m A )
0.1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

Page -183-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CYT EC RS/8-S M ain fr am e


SN 136906 D25 "Co n tr o l Co n n e ctor " SW 04-02-04
100
Amplitude (dBm)

10

Lab S c alibration forward power level (dB m )


1
10000 100000 1000000 10000000 100000000 1000000000
Fr e q u e n cy (Hz )

C YT EC R S /8 -S M a i n fra m e
S N 1 3 6 9 0 6 D 2 5 "C o n tro l C o n n e c to r" S W 0 4 -0 2 -0 4
100
Amplitude (mA)

10

C a lib ra t io n le ve l (m A )
L a b S m e a s u re d c a lib ra tio n le ve l (m A )
1
10000 100000 1000000 10000000 100000000 1000000000
Fr e q u e n c y ( Hz )

Page -184-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

C Y T E C R S /8 -S M a in fr a m e
S N 1 3 6 9 0 6 D 2 5 " C o n tr o l C o n n e c to r " S W 0 4 -0 2 -0 4
1000

100

C a lib ra tio n L a b S L e v e ls (d B u V )
C a lib ra tio n L im it (d B u V )
10
10000 100000 1000000 10000000 100000000 1000000000
F r e q u e n c y (H z )

CYTEC RS/8-S Mainframe


SN 136906 D25 "Control Connector" SW 04-02-04
1000

100

Current Limit (dBuA)


Test Current (dBuA)
10
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

Page -185-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

CYTEC RS/8-S M ainfr am e


SN 136906 D25 "Contr ol Conne ctor" SW 04-02-04
10 0 0

10 0

10

Lab S Calibration Forward Power (mA)


Lab S Test Forward Power (mA)
1
10 0 0 0 10 0 0 0 0 10 0 0 0 0 0 10 0 0 0 0 0 0 10 0 0 0 0 0 0 0 10 0 0 0 0 0 0 0 0
F r e q ue nc y ( Hz )

CYTEC RS/8-S Mainfram e


SN 136906 D25 "Control Connector" SW 04-02-04
100
Amplitude (dBm)

10

Measured Forward Power (dBm)


Calibrated Forward Power (dBm)
1
10000 100000 1000000 10000000 100000000 1000000000
Frequency (Hz)

Page -186-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 PHOTOS TAKEN DURING TESTING:

AC CABLE

Page -187-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 PHOTOS TAKEN DURING TESTING:

D9 INPUT PORT

Page -188-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 PHOTOS TAKEN DURING TESTING:

D9 SIGNAL I/O

Page -189-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 PHOTOS TAKEN DURING TESTING:

D25 CONTROL CONNECTOR

Page -190-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SECTION 20.4

TEST INSTRUMENTATION

TABLE 1

Model Serial Cal Cal Due


Description Manufacturer Number Number Range On Dates
Spectrum Agilent E4411B MY4144 10 kHz – 12/12/03 12/12/04
Analyzer 00693 400 MHz
Spectrum Agilent E4411B MY4144 10 kHz – 12/12/03 12/12/04
Analyzer 0681 400 MHz
Display
Signal Rohde & SML01 100025 10 kHz – 10/03/03 10/03/04
Generator Schwarz 400 MHz
RF Current Solar F-55 54 10 kHz – 5/08/03 5/08/04
Probe 400 MHz

All primary equipment is calibrated against known reference standards with a verified traceable path NIST.

Page -191-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SECTION 20.4

TEST EQUIPMENT

TABLE 2

Model Serial
Description Manufacturer Number Number Range
Amplifier Amplifier 50W 23419 80 MHz – 400 MHz
Research 1000A
Amplifier Amplifier 150A100 14331 10 kHz – 80 MHz
Research
RF Coupler Amplifier DC6180 303130 80 MHz – 400 MHz
Research
RF Coupler Amplifier DC2035 301080 10 kHz – 80 MHz
Research
Software Dell Dimension N/A 10 kHz – 400 MHz
Computer L100R
RF Injection Solar 9142-1N 945013 80 MHz – 400 MHz
Probe
RF Injection Solar 9144-1N 974512 10 kHz – 80 MHz
Probe

Page -192-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

APPENDIX F

RTCA/DO-160D

SECTION 20.5

Radiated Susceptibility
100 MHz – 18 GHz

Page -193-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

1.0 PURPOSE OF THE TEST:

This test determines whether equipment will operate within performance specifications when the
equipment and its interconnecting wiring are exposed to a level of RF modulated power by a radiated
RF field.

For frequencies between 100 MHz and the upper frequency limit, the Ruggadized 9 Pole Switching
Multiplexer is subjected to radiated RF fields.

Equipment with special signal, frequency, modulation or band pass characteristics may require test
variations as specified by the applicable performance standards.

The result of this test is to permit categories to be assigned defining radiated RF, along with the
conducted test levels of the equipment. These tests are sufficient to obtain environmental qualification
for radio frequency susceptibility of the equipment. Additional tests may be necessary to certify the
installation of systems in an aircraft dependent on the functions performed.

Page -194-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

2.0 EQUIPMENT CATEGORIES:

Categories designate the RF test levels and establish the EUT minimum RF susceptibility level. The
categories may be given in the applicable equipment performance standard.

The category to be applied to a system or equipment frequently must be chosen before the internal RF
environment of the aircraft is known. Further, many systems or equipments are designed with the
intent that they will be installed in several different types of aircraft. Therefore, if a category is not
identified in the equipment specification, the equipment manufacturer should design, test and qualify
the equipment to the category level consistent with expected location, exposure and use.

Category designation for equipment consists of three characters. Radiated susceptibility test levels are
designated with the first category character. Continuous wave (CW) and square wave (SW) modulated
radiated susceptibility test levels are designated with the second category character. Pulse modulated
radiated susceptibility test levels are designated with the third category character.

To aid the equipment manufacturer in selecting appropriate test limits for the equipment and its
interconnecting wiring, categories have been defined below. The descriptions are for guidance only.
Equipment location, anticipated exposure and location of interconnecting wiring, aircraft size and
construction determine the test level.

The Ruggadized 9 Pole Switching Multiplexer was subjected to Category V.

Category V is intended for equipments and interconnecting wiring installed in a moderate environment
such as the more electromagnetically open areas of an aircraft composed principally of metal.

Page -195-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

3.0 TEST SETUP AND APPARATUS:

The Ruggadized 9 Pole Switching Multiplexer shall be set up according to Figure 20.2 shown below.

Signal generators, amplifiers, antennas and probes shall maintain required RF field levels to properly
illuminate the EUT and interconnecting wiring. Position and aim antennas to establish the RF field
strengths at the EUT and interconnecting wiring. When the beam width of the antenna does not totally
cover the EUT and wiring, perform multiple area scans. Directly expose apertures in the EUT to the
transmitting antenna, which may require additional LRU orientations. Vertical and horizontal antenna
orientations are required for polarized antennas.

Page -196-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

4.0 TEST PROCEDURE:

Establish appropriate antenna and isotropic probe locations, software installation, modes of operation
and stability of the EUT, test equipment and all monitoring circuits and loads.

CAUTION: RF fields can be hazardous. Observe appropriate RF exposure limits.

Use the forward power settings determined from the radiated field calibration. When modulation is
applied, ensure that the peak amplitude complies with the definitions of Figure 20-5.

Scan the frequency range to the upper frequency limit using the proper antennas and modulations.
Dwell at internal modulation, data and clock frequencies, as required.

While scanning, evaluate EUT operation and DETERMINE COMPLIANCE WITH APPLICABLE
EQUIPMENT PERFORMANCE STANDARDS.

Page -197-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

Page -198-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

5.0 LIMITS & RESULTS:

5.1 LIMITS:

The Ruggadized 9 Pole Switching Multiplexer was subjected to Category V as shown in Figure
20-10 below:

FIGURE 20-10

5.2 RESULTS:

There were no problems found at this level.

Page -199-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 20.5

RADIATED SUSCEPTIBILITY

FORWARD POWER CW TEST DATA SHEETS

100 MHz to 8000 MHz

Page -200-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 100-200MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Forward Power Level & Modulation - 50V/m, CW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
100.0M 1.0G
Frequency

03:44:29 PM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 100-200MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Forward Power Level & Modulation - 50V/m, CW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
100.0M 1.0G
Frequency

04:10:22 PM, Wednesday, March 31, 2004

Page -201-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 200-1000MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Forward Power Level & Modulation - 50V/m, CW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

100.0M 1.0G
Frequency

04:47:54 PM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 200-1000MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Forward Power Level & Modulation - 50V/m, CW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

100.0M 1.0G
Frequency

05:49:29 PM, Wednesday, March 31, 2004

Page -202-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 1-2.8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Forward Power Level & Modulation - 50 V/m, CW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

08:37:08 AM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 1-2.8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Forward Power Level & Modulation - 50 V/m, CW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

09:19:39 AM, Wednesday, March 31, 2004

Page -203-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8


Freq. Range - 2.8-5 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Forward Power Level & Modulation - 50 V/m, CW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

10:07:37 AM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 2.8-5 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Forward Power Level & Modulation - 50 V/m, CW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

10:34:45 AM, Wednesday, March 31, 2004

Page -204-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 5-7.5 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Forward Power Level & Modulation - 50 V/m, CW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

12:44:58 PM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 5-7.5 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Forward Power Level & Modulation - 50 V/m, CW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

11:38:02 AM, Wednesday, March 31, 2004

Page -205-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 7.5-8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Forward Power Level & Modulation - 50 V/m, CW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

01:19:05 PM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 7.5-8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Forward Power Level & Modulation - 50 V/m, CW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

01:13:54 PM, Wednesday, March 31, 2004

Page -206-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 20.5

RADIATED SUSCEPTIBILITY

FORWARD POWER SW TEST DATA SHEETS

100 MHz to 8000 MHz

Page -207-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 100-200MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Forward Power Level & Modulation - 50V/m, SW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
100.0M 1.0G
Frequency

03:56:37 PM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 100-200MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Forward Power Level & Modulation - 50V/m, SW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
100.0M 1.0G
Frequency

04:04:43 PM, Wednesday, March 31, 2004

Page -208-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 200-1000MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Forward Power Level & Modulation - 50V/m, SW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
100.0M 1.0G
Frequency

05:01:48 PM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 200-1000 MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Forward Power Level & Modulation - 50V/m, SW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
100.0M 1.0G
Frequency

06:02:41 PM, Wednesday, March 31, 2004

Page -209-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160 Section 20.5 EUT - Rs/S-8 Mainframe


Freq. Range - 1-2.8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Forward Power Level & Modulation - 50 V/m, SW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

08:52:28 AM, Wednesday, March 31, 2004

RTCA/DO-160 Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 1-2.8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Forward Power Level & Modulation - 50 V/m, SW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

09:09:15 AM, Wednesday, March 31, 2004

Page -210-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160 Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 2.8-5 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Forward Power Level & Modulation - 50 V/m, SW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

10:15:43 AM, Wednesday, March 31, 2004

RTCA/DO-160 Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 2.8-5GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Forward Power Level & Modulation - 50 V/m, SW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

10:24:33 AM, Wednesday, March 31, 2004

Page -211-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160 Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 5-7.5GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Forward Power Level & Modulation - 50 V/m, SW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

12:39:30 PM, Wednesday, March 31, 2004

RTCA/DO-160 Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 5-7.5 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Forward Power Level & Modulation - 50 V/m, SW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

12:29:57 PM, Wednesday, March 31, 2004

Page -212-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160 Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 7.5-8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Forward Power Level & Modulation - 50 V/m, SW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

01:23:16 PM, Wednesday, March 31, 2004

RTCA/DO-160 Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 7.5-8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Forward Power Level & Modulation - 50 V/m, SW

100.0

90.0

80.0

70.0
Amplitude (dBm)

60.0

50.0

40.0

30.0

20.0
Calibrated Forward Power
10.0 Test Forward Power

0
1.0G 10.0G
Frequency

01:09:27 PM, Wednesday, March 31, 2004

Page -213-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 20.5

RADIATED SUSCEPTIBILITY

PROBE CW TEST DATA SHEETS

100 MHz to 8000 MHz

Page -214-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 100-200MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Probe Values Obtained During Calibration Level & Modulation - 50V/m, CW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
100.0M 1.0G
Frequency

03:34:34 PM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 100-200MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Probe Values Obtained During Calibration Level & Modulation - 50V/m, CW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
100.0M 1.0G
Frequency

03:26:08 PM, Wednesday, March 31, 2004

Page -215-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 200-1000MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Probe Values Obtained During Calibration Level & Modulation - 50V/m, CW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

100.0M 1.0G
Frequency

04:32:48 PM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 200-1000MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Probe Values Obtained During Calibration Level & Modulation - 50V/m, CW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

100.0M 1.0G
Frequency

05:26:32 PM, Wednesday, March 31, 2004

Page -216-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 1-2.8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, CW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

08:19:14 AM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 1-2.8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, CW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

04:21:36 PM, Tuesday, March 30, 2004

Page -217-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8


Freq. Range - 2.8-5 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, CW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

09:56:08 AM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 2.8-5 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, CW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

09:48:38 AM, Wednesday, March 31, 2004

Page -218-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 5-7.5 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, CW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

11:12:02 AM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 5-7.5 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, CW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

11:24:38 AM, Wednesday, March 31, 2004

Page -219-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 7.5-8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, CW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

12:56:58 PM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 7.5-8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, CW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

01:01:32 PM, Wednesday, March 31, 2004

Page -220-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 20.5

RADIATED SUSCEPTIBILITY

PROBE SW TEST DATA SHEETS

100 MHz to 8000 MHz

Page -221-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 100-200MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Probe Values Obtained During Calibration Level & Modulation - 50V/m, SW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
100.0M 1.0G
Frequency

03:34:34 PM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 100-200MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Probe Values Obtained During Calibration Level & Modulation - 50V/m, SW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
100.0M 1.0G
Frequency

03:26:08 PM, Wednesday, March 31, 2004

Page -222-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 200-1000MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Probe Values Obtained During Calibration Level & Modulation - 50V/m, SW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
100.0M 1.0G
Frequency

04:32:48 PM, Wednesday, March 31, 2004

RTCA/DO-160D Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 200-1000 MHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Probe Values Obtained During Calibration Level & Modulation - 50V/m, SW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
100.0M 1.0G
Frequency

05:26:32 PM, Wednesday, March 31, 2004

Page -223-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160 Section 20.5 EUT - Rs/S-8 Mainframe


Freq. Range - 1-2.8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, SW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

08:19:14 AM, Wednesday, March 31, 2004

RTCA/DO-160 Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 1-2.8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, SW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

04:21:36 PM, Tuesday, March 30, 2004

Page -224-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160 Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 2.8-5 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, SW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

09:56:08 AM, Wednesday, March 31, 2004

RTCA/DO-160 Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 2.8-5GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, SW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

09:48:38 AM, Wednesday, March 31, 2004

Page -225-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160 Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 5-7.5GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, SW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

11:12:02 AM, Wednesday, March 31, 2004

RTCA/DO-160 Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 5-7.5 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, SW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

11:24:38 AM, Wednesday, March 31, 2004

Page -226-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160 Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 7.5-8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Vertical
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, SW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

12:56:58 PM, Wednesday, March 31, 2004

RTCA/DO-160 Section 20.5 EUT - RS/S-8 Mainframe


Freq. Range - 7.5-8 GHz
D.L.S. Electronic Systems, Inc. Ant. Position - EUT
Ant. Polarization - Horizontal
Probe Values Obtained During Calibration Level & Modulation - 50 V/m, SW

250.0

225.0

200.0

175.0
Amplitude (V/m)

150.0

125.0

100.0

75.0

50.0

Calibrated Probe Values


25.0

0
1.0G 10.0G
Frequency

01:01:32 PM, Wednesday, March 31, 2004

Page -227-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 PHOTOS TAKEN DURING TESTING:

PROBE LOCATION DURING CALIBRATION

Page -228-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 PHOTOS TAKEN DURING TESTING: (CON’T)

100 MHz TO 200 MHz VERTICAL POLARIZATION

Page -229-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 PHOTOS TAKEN DURING TESTING: (CON’T)

100 MHz TO 200 MHz HORIZONTAL POLARIZATION

Page -230-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 PHOTOS TAKEN DURING TESTING: (CON’T)

200 MHz TO 1000 MHz VERTICAL POLARIZATION

Page -231-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 PHOTOS TAKEN DURING TESTING: (CON’T)

200 MHz TO 1000 MHz HORIZONTAL POLARIZATION

Page -232-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 PHOTOS TAKEN DURING TESTING: (CON’T)

1000 MHz TO 5000 MHz VERTICAL POLARIZATION

Page -233-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 PHOTOS TAKEN DURING TESTING: (CON’T)

1000 MHz TO 5000 MHz HORIZONTAL POLARIZATION

Page -234-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 PHOTOS TAKEN DURING TESTING: (CON’T)

5000 MHz TO 8000 MHz VERTICAL POLARIZATION

Page -235-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 PHOTOS TAKEN DURING TESTING: (CON’T)

5000 MHz TO 8000 MHz HORIZONTAL POLARIZATION

Page -236-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SECTION 20.5

TEST INSTRUMENTATION

TABLE 1

Model Serial Cal Cal Due


Description Manufacturer Number Number Range On Dates
Spectrum Hewlett 8566B 2421A 2 – 22 GHz 1/09/04 1/09/05
Analyzer Packard 00452
Spectrum Hewlett 85622A 2043A N/A 1/09/04 1/09/05
Analyzer Packard 06406
Display
Signal Rohde & SLM-01 100025 9 kHz – 1.1 GHz 10/30/03 10/30/04
Generator Schwarz
Signal Rohde & SLM-20 100052 1 GHz – 20 GHz 7/29/03 7/29/04
Generator Schwarz
Field Strength Amplifier FP5083 300136 80 MHz – 40 GHz 5/22/03 5/22/04
Probe Research
Coupler Amplifier DC6280 22293 80 MHz – 1 GHz 10/28/03 10/28/04
Research

All primary equipment is calibrated against known reference standards with a verified traceable path NIST.

Page -237-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SECTION 20.5

TEST EQUIPMENT FOR

TABLE 2

Model Serial
Description Manufacturer Number Number Range
Field Monitor Amplifier FM5004 302153 NA
Research
Amplifier Amplifier 1000W 22243 100 – 1000 MHz
Research 1000M7
TWT Amplifier Amplifier 200T1G3A 301643 800 MHz –
Research 2.8 GHz
TWT Amplifier Amplifier 200T2G8A 301027 2.5 GHz –
Research 7.5 GHz
TWT Amplifier Amplifier 200T8G18A 301107 7.5 GHz –
Research 18 GHz
RS Dell Dimension N/A N/A
Computer L1000R
Test Software Quantum Rev 2.28 N/A N/A
(T.I.E.)
Log Antenna Amplifier AT1230 23709 80 – 230 MHz
Research
Tripod Amplifier TP1000A 301946 N/A
Research
Large Horn Amplifier AT4000 22305 200 – 1000 MHz
Antenna Research
Medium Horn Amplifier AT4002A 301759 800 MHz –
Antenna Research 5 GHz
Small Horn Amplifier AT4003 301597 4 – 8 GHz
Antenna Research

Page -238-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

APPENDIX G

RTCA/DO-160D

SECTION 21

Emission of Radio Frequency Energy

Page -239-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

1.0 PURPOSE OF THE TEST:

These tests determine that the equipment does not emit undesired RF noise in excess of the levels
specified below. The notches specified in the radiated emissions limits are included to protect aircraft
RF sensors operating frequencies.

2.0 EQUIPMENT CATEGORIES:

Categories are defined in terms of location and separation between the equipment and aircraft radio
antennas. As these parameters are widely linked to aircraft type and size, some examples are given
with each category definition.

The Ruggadized 9 Pole Switching Multiplexer was subjected to Category M. A 7 dB relaxation limit
was applied to the Category L limits on the Integrated Drive Generator (IDG) Output Feeder wires
from 150 kHz to 500 kHz.

Page -240-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

3.0 TEST SETUP AND APPARATUS:

The conducted setup can be seen in Figure 21-3 shown below:

The radiated setup can be seen in Figure 21-7 shown below:

Page -241-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

4.0 TEST PROCEDURE:

Conducted RF Emission:

a. Interference currents generated by the equipment and measured by using a clamp-on interference
measuring device within the frequency ranges and in excess of the values given in Figure 21-1 shall
not appear on any power line normally connected to an aircraft bus.

Line Impedance Stabilization Networks (LISNs) shall be used as shown in Figure 21-3. Power return
wires tied locally to the ground plane as noted in RTCA/DO-160C/D Section 20.3a(6) are not tested.

b. Interference currents on interconnecting cable bundles other than antenna feed cables and
primary power lines shall be measured by using a clamp-on interference measuring device.
The limits and frequency ranges are as shown in Figure 21-2.

Figure 21-3 shows a simplified test arrangement for the use of the current probe.

Install the current probe five centimeters from the EUT. If the EUT connector plus backshell length
exceeds five centimeters the probe shall be placed as close to the connector backshell as possible and
the position noted.

Radiated RF Emission:

Radiated interference fields generated by the equipment within the frequency ranges, and in excess of
the values shown in Figures 21-4 for the appropriate categories, shall not be radiated from any unit,
cable or interconnecting wiring. A typical arrangement of equipment for conducting the radiated RF
emission test is shown in Figure 21-7.

NOTE:
Subsection 21.4 does not measure or control spurious signals conducted out of the antenna terminals
of receivers and transmitters. That control should be specified in the equipment performance standard
for that receiver or transmitter.

Page -242-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

4.0 TEST PROCEDURE (CON’T):

General Requirements:

The equipment under test shall be set up on a ground plane and operated in accordance with the
criteria in Subsection 20.3 subparagraph a and parts 1, 2 and 5 of subparagraph b, with the following
additions:

a. Interference shall be measured using the peak detector function of the interference measuring
equipment. Interference measuring instruments with selectable IF bandwidths (BWI) may be used,
and the selected BWI must be the values given in the following table. The time constant of the
peak detector must be lower or equal to 1/BWI. Where applicable, video bandwidths shall be
selected to be greater than or equal to the resolution bandwidth.

Frequency Bands BWI


0.15 – 30 MHz 1 kHz
30 – 400 MHz 10 kHz
400 – 1000 MHz 100 kHz
1000 – 6000 MHz 1 MHz

Note: During radiated tests the above bandwidths may not provide a low enough noise floor to make
proper measurements in the notches defined for categories M & H. In that case, a 10 kHz BWI
shall be used for measurements in the notches with no correction factor being applied.

b. Field strength units are obtain by using any appropriate antenna and adding the appropriate antenna
factor to the measured voltage in dB microvolts. Appropriate correction factor for cable losses and
matching networks must also be applied.

c. When linearly polarized antennas are used for radiated tests above 25 MHz, measure radiated
emissions using both vertically and horizontally polarized orientations.

d. For EUT with multiple apertures and sensors such as displays, several different orientations may be
required, for example connector side and aperture side(s) facing the antenna.

e. Consider EUT realistic operating modes that produce maximum emission.

f. Radiated ambient data (EUT "off" and test support equipment "on") is required only if EUT
emissions are greater than 3 dB below the selected category limit. It is good engineering practice to
check ambient radiated emissions prior to a radiated emissions test, and it is desirable that the
ambient emissions be at least 6 dB below the selected limit line.

g. Measure and record the EUT emissions conditions and apply the appropriate limit from Figures 21-
4 for the selected category.

Page -243-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

5.0 LIMITS & RESULTS:

5.1 LIMITS:

The maximum level of conducted RF interference on the power lines is shown in Figure 21-1 using
Category M:

The maximum level of conducted RF interference on interconnecting cables is shown in Figure 21-2
using Category M:

Page -244-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

5.0 LIMITS & RESULTS (CON’T):

5.1 LIMITS:

The maximum level of radiated RF interference is shown in Figure 21-4 & Figure 21-5 using
Category M:

Page -245-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

5.0 LIMITS & RESULTS CON’T:

5.1 LIMITS:

5.2 RESULTS:

There were no problems found during testing.

Page -246-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 21

EMISSION OF RADIO FREQUENCY ENERGY

VERIFICATION DATA AND GRAPHS

Page -247-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 21

EMISSION OF RADIO FREQUENCY ENERGY

CONDUCTED EMISSION GRAPHS

Page -261-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

RTCA/DO-160D

Section 21

EMISSION OF RADIO FREQUENCY ENERGY

RADIATED EMISSION GRAPHS

Page -270-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 CONDUCTED EMISSIONS PHOTOS TAKEN DURING TESTING

AC POWER

Page -285-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 CONDUCTED EMISSIONS PHOTOS TAKEN DURING TESTING: (CON’T)

D9 PORT 0

Page -286-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 CONDUCTED EMISSIONS PHOTOS TAKEN DURING TESTING: (CON’T)

D9 PORT SIGNAL I/O

Page -287-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 CONDUCTED EMISSIONS PHOTOS TAKEN DURING TESTING: (CON’T)

D25P CONTROL

Page -288-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 RADIATED EMISSIONS PHOTOS TAKEN DURING TESTING:

SETUP 1

Page -289-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 RADIATED EMISSIONS PHOTOS TAKEN DURING TESTING: (CON’T)

SETUP 2

Page -290-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 RADIATED EMISSIONS PHOTOS TAKEN DURING TESTING: (CON’T)

SETUP 3

Page -291-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 RADIATED EMISSIONS PHOTOS TAKEN DURING TESTING: (CON’T)

2 MHz TO 25 MHz

Page -292-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 RADIATED EMISSIONS PHOTOS TAKEN DURING TESTING: (CON’T)

25 MHz TO 200 MHz VERTICAL POLARIZATION

Page -293-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 RADIATED EMISSIONS PHOTOS TAKEN DURING TESTING: (CON’T)

25 MHz TO 200 MHz HORIZONTAL POLARIZATION

Page -294-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 RADIATED EMISSIONS PHOTOS TAKEN DURING TESTING: (CON’T)

200 MHz TO 1000 MHz VERTICAL POLARIZATION

Page -295-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 RADIATED EMISSIONS PHOTOS TAKEN DURING TESTING: (CON’T)

200 MHz TO 1000 MHz HORIZONTAL POLARIZATION

Page -296-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 RADIATED EMISSIONS PHOTOS TAKEN DURING TESTING: (CON’T)

1000 MHz TO 6000 MHz VERTICAL POLARIZATION

Page -297-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

6.0 RADIATED EMISSIONS PHOTOS TAKEN DURING TESTING: (CON’T)

1000 MHz TO 6000 MHz HORIZONTAL POLARIZATION

Page -298-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SECTION 21.3

CONDUCTED RF EMISSIONS

TEST INSTRUMENTATION

TABLE 1

Model Serial Cal Cal Due


Description Manufacturer Number Number Range On Dates
Spectrum Hewlett 8566B 3138A 2 – 22 GHz 12/03/01 8/12/04
Analyzer Packard 07914
Spectrum Hewlett 85622A 3144A 100 Hz – 8/12/01 8/12/04
Analyzer Packard 21038 22 GHz
Display
Quasi Peak Hewlett 85650A 3107A NA 12/29/03 12/29/04
Detector Packard 01519
RF Pre-Selector Hewlett 8568A 2947A 20 Hz – 12/29/03 12/29/04
Packard 01023 2 GHz
Current Probe Fischer F-55 62 10 kHz – 8/06/03 8/06/04
100 MHz

All primary equipment is calibrated against known reference standards with a verified traceable path NIST.

Page -299-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SECTION 21.3

CONDUCTED RF EMISSIONS

TEST EQUIPMENT

TABLE 2

Model Serial
Description Manufacturer Number Number Range
Computer Packard Bell 204CD N351041092 N/A

EMI Hewlett 85869A N/A N/A


Measurement Packard Rev.
Software A.04.01
Plotter Hewlett 7550A 2725A N/A
Packard 89078
3 Coaxial Pasternack RG223-U N/A 10 kHz –
Cables 1 GHz
Printer Hewlett LASER JET USPG039860 N/A
Packard 1100
RF Limiter Hewlett 11867A 05085 0 – 1800 MHz
Packard
Monitor Packard Bell 1402S 2MMN N/A
52009852

Page -300-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SECTION 21.4

RADIATED RF EMISSIONS

TEST INSTRUMENTATION

TABLE 1

Model Serial Cal Cal Due


Description Manufacturer Number Number Range On Dates
Spectrum Hewlett 8566B 2240A 100 Hz-25 GHz 12/29/03 12/29/04
Analyzer Packard 02041 2-22 GHz
Spectrum Hewlett 85622A 2304A 100 Hz – 12/29/03 12/29/04
Analyzer Packard 04459 22 GHz
Display
RF Pre- Hewlett 85685A 2901A 20 Hz – 2 GHz 12/29/03 12/29/04
Selector Packard 00884
Rod Antenna EMCO 3301 2614 30 Hz – 50 12/04/03 12/04/04
MHz
Bicon Antenna Electro-Metrics BIA-25C 2617 20 MHz – 220 8/12/03 8/12/04
MHz
Double-Ridge EMCO 3106 2127 200 MHz – 8/12/03 8/12/04
Wave Guide 2 GHz
(DRWG) Horn
Antenna
Double-Ridge EMCO 3115 2304 1 –18 GHz 12/03/03 12/03/04
Wave Guide
(DRWG) Horn
Antenna
Pre-Amp MITEQ AMF-60- 580257 1 GHz – 9/01/03 9/01/04
010100- 10 GHz
50
Pre-Amp Electro-Metrics EM4206 265 10 kHz – 1/02/04 1/02/05
1 GHz

All primary equipment is calibrated against known reference standards with a verified traceable path NIST.

Page -301-
Company: CYTEC Corporation
Model Tested: RS-8-S-R Mainframe
Report Number: 10683

1250 Peterson Dr., Wheeling, IL 60090

SECTION 21.4

RADIATED RF EMISSIONS

TEST EQUIPMENT

TABLE 2

Model Serial
Description Manufacturer Number Number Range
Coaxial Cable Pasternack RG223-U N/A 10 kHz – 1 GHz

Coaxial Cable Micro Coax UFB311A N/A 1 GHz – 10 GHz

RF Limiter Hewlett 11867A 05085 0 – 1800 MHz


Packard
Counterpoise EMCO N/A N/A 60 cm x 60 cm

Computer Packard Bell 204 CD N351041092 N/A

Monitor Packard Bell 1402S LMMN N/A


52009852
EMI Hewlett 85869A N/A N/A
Measurement Packard Rev.
Software A.04.01

Page -302-