15.11.2017
TEST REPORT
IEC 60335-43
Safety of household and similar electrical appliances
Part 2: Particular requirements for room heaters, clothes dryers and
towel rails
Report Number. .............................. : 201700368TUR-001
Date of issue ................................... : 15.11.2017
Total number of pages .................... 130
Name of Testing Laboratory Intertek Test Hizmetleri A.Ş Electrical Laboratory
preparing the Report ...................... :
Applicant’s name............................ : Radiva Isı Sistemleri San Ve Tic. Ltd. Şti.
Address ........................................... : İçmeler Mahallesi Reis Sok No:3/B Tuzla / İstanbul
Test specification:
Standard .......................................... : IEC 60335-2-43:2004 /AMD1:2005 /AMD2:2008 used in
conjunction with IEC 60335-1:2010 incl. Corr1:2010/ Corr 2:2011
/AMD1:2013
Test procedure ............................... : LVD Test Report
Non-standard test method ............ : N/A
Test Report Form No...................... : IEC60335_2_43H
Test Report Form(s) Originator .... : LCIE
Master TRF ...................................... : Dated 2016-10
Copyright © 2016 IEC System of Conformity Assessment Schemes for Electrotechnical
Equipment and Components (IECEE System). All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting
from the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the
CB Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory
and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing
Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,
responsible for this Test Report.
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
Responsible Testing Laboratory (as applicable), testing procedure and testing location(s):
CB Testing Laboratory:
Testing location/ address ............................. : Intertek Test Hizmetleri A.Ş Electrical Laboratory
Merkez Mah. Sanayi Cad. No:23 Altındağ Plaza
Yenibosna 34197 İstanbul TURKEY
Tested by (name, function, signature) ........ : Alper PEKGOZ
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
List of Attachments:
- EN 60335-2-43:2003 + A1:2006 + A2:2008 used in conjunction with EN 60335 1:2012 +AC:2014 +
A11:2014 EN 62233:2008 (14 Pages)
- IEC 60335-1:2010/A2:2016 (5 pages)
- Measurement equipment list (1 page)
- Photo documentation (3 Pages)
Summary of testing: The EUT passed the requirements of the applied standards within this test report.
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
The whole and/or the part of this report shall not be reproduced and shall not be shared with third parties,
nor to be used for juridical – official and PR activities without the written permission of INTERTEK Test
Hizmetleri A.S. The results given herein apply to the submitted sample only. Reports are invalid without
signature / seal.
The results are reported with an expanded uncertainty calculated using a coverage factor k of 2 which gives
a level of confidence of approximately 95%.
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : Radiva Isı Sistemleri San Ve Tic. Ltd. Şti.
İçmeler Mahallesi Reis Sok No:3/B Tuzla / İstanbul
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
Techinal ratings:
Brand Model Voltage (V) Frequency (Hz) Power (W) Dimension (mm)
Radiva Haiti 230 50 200 400x700
Radiva Haiti 230 50 200 400x800
Radiva Haiti 230 50 300 400x1000
Radiva Haiti 230 50 300 400x1100
Radiva Haiti 230 50 300 400x1200
Radiva Haiti 230 50 300 400x1400
Radiva Haiti 230 50 600 400x1500
Radiva Haiti 230 50 600 400x1600
Radiva Haiti 230 50 600 400x1800
Radiva Haiti 230 50 300 500x700
Radiva Haiti 230 50 300 500x800
Radiva Haiti 230 50 300 500x1000
Radiva Haiti 230 50 300 500x1100
Radiva Haiti 230 50 600 500x1200
Radiva Haiti 230 50 600 500x1400
Radiva Haiti 230 50 600 500x1500
Radiva Haiti 230 50 600 500x1600
Radiva Haiti 230 50 600 500x1800
Radiva Haiti 230 50 300 600x700
Radiva Haiti 230 50 300 600x800
Radiva Haiti 230 50 300 600x1000
Radiva Haiti 230 50 600 600x1100
Radiva Haiti 230 50 600 600x1200
Radiva Haiti 230 50 600 600x1400
Radiva Haiti 230 50 600 600x1500
Radiva Haiti 230 50 600 600x1600
Radiva Haiti 230 50 900 600x1800
Radiva Haiti 230 50 300 700x700
Radiva Haiti 230 50 300 700x800
Radiva Haiti 230 50 600 700x1000
Radiva Haiti 230 50 600 700x1100
Radiva Haiti 230 50 600 700x1200
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
Barbados 500x800mm
Fiji 650x1250mm
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
Haiti 500x800mm
Haiti 600x1800mm
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
11.8 Temperature rises monitored continuously and not (see appended table) P
exceeding the values in table 3 ............................:
If the temperature rise of a motor winding exceeds N/A
the value of table 3, or
if there is doubt with regard to classification of N/A
insulation,
tests of Annex C are carried out N/A
Sealing compound does not flow out N/A
Protective devices do not operate, except P
components in protective electronic circuits tested N/A
for the number of cycles specified in 24.1.4
Temperature rise of textile not exceeding 75 K P
(IEC 60335-2-43)
Temperature rise limits of motors, transformers or N/A
components of electronic circuits and other parts
may be exceed by 1.15 times rated power input
(IEC 60335-2-43)
For oil-filled appliances, the temperature rise of N/A
parts in contact with oil is not measured.
(IEC 60335-2-43)
11.101 Towel rails operated at rated power input but without textiles (IEC 60335-2-43) P
Temperature rises of the surface not exceeding the following values P
(IEC 60335-2-43):
metal and painted metal surfaces : < 60K P
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
16.2 Single-phase appliances: test voltage 1.06 times 1.06 x 230V = 243.8V for all P
rated voltage (V) ....................................................: tested models
Three-phase appliances: test voltage 1.06 times N/A
rated voltage divided by 3 (V) .............................:
Leakage current measurements ...........................: (see appended table) P
Limit values doubled if: N/A
- all controls have an off position in all poles, or N/A
- the appliance has no control other than a thermal N/A
cut-out, or
- all thermostats, temperature limiters and energy N/A
regulators do not have an off position, or
- the appliance has radio interference filters N/A
With the radio interference filters disconnected, the (see appended table) N/A
leakage current do not exceed limits specified .....:
16.3 Electric strength tests according to table 7 ...........: (see appended table) P
Test voltage applied between the supply cord and (see appended table) P
inlet bushing and cord guard and cord anchorage
as specified ...........................................................:
No breakdown during the tests P
17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS
No excessive temperatures in transformer or (see appended table) N/A
associated circuits in event of short-circuits likely to
occur in normal use ...............................................:
Appliance supplied with 1.06 or 0.94 times rated N/A
voltage under the most unfavourable short-circuit or
overload likely to occur in normal use (V) .............:
Basic insulation is not short-circuited N/A
Temperature rise of insulation of the conductors of N/A
safety extra-low voltage circuits not exceeding the
relevant value specified in table 3 by more than
15 K
Temperature of the winding not exceeding the N/A
value specified in table 8
However, limits do not apply to fail-safe N/A
transformers complying with sub-clause 15.5 of IEC
61558-1
18 ENDURANCE
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
During the test, parts not being ejected from the N/A
appliance
19.11 Electronic circuits, compliance checked by N/A
evaluation of the fault conditions specified in
19.11.2 for all circuits or parts of circuits, unless
they comply with the conditions specified in 19.11.1 N/A
Appliances incorporating an electronic circuit that N/A
relies upon a programmable component to function
correctly, subjected to the test of 19.11.4.8, unless
restarting does not result in a hazard N/A
Appliances having a device with an off position N/A
obtained by electronic disconnection, or a device
placing the appliance in a stand-by mode,
subjected to the tests of 19.11.4
If the safety of the appliance under any of the fault N/A
conditions depends on the operation of a miniature
fuse-link complying with IEC 60127, the test of
19.12 is carried out
During and after each test the following is checked: N/A
- the temperature of the windings do not exceed the N/A
values specified in table 8
- the appliance complies with the conditions N/A
specified in 19.13
- any current flowing through protective impedance N/A
not exceeding the limits specified in 8.1.4
If a conductor of a printed board becomes open-circuited, the appliance is N/A
considered to have withstood the particular test, provided both of the following
conditions are met:
- the base material of the printed circuit board N/A
withstands the test of Annex E
- any loosened conductor does not reduce N/A
clearance or creepage distances between live parts
and accessible metal parts below the values
specified in clause 29
19.11.1 Fault conditions a) to g) in 19.11.2 are not applied to circuits or parts of circuits N/A
meeting both of the following conditions:
- the electronic circuit is a low-power circuit, that is, N/A
the maximum power at low-power points does not
exceed 15 W according to the tests specified
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
Thread-cutting, thread rolling and space threaded screws may be used in N/A
connections providing earthing continuity provided it is not necessary to disturb the
connection:
- in normal use, N/A
- during user maintenance, N/A
- when replacing a supply cord having a type X N/A
attachment, or
- during installation N/A
At least two screws being used for each connection N/A
providing earthing continuity, unless
the screw forms a thread having a length of at least N/A
half the diameter of the screw
28.4 Screws and nuts that make mechanical connection N/A
secured against loosening if they also make
electrical connections or connections providing
earthing continuity
This requirement does not apply to screws in the N/A
earthing circuit if at least two screws are used, or
if an alternative earthing circuit is provided N/A
Rivets for electrical connections or connections N/A
providing earthing continuity secured against
loosening if the connections are subjected to
torsion
29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION
Clearances, creepage distances and solid P
insulation withstand electrical stress
For coatings used on printed circuits boards to N/A
protect the microenvironment (Type 1) or to provide
basic insulation (Type 2), Annex J applies ............:
The microenvironment is pollution degree 1 under N/A
type 1 protection
For type 2 protection, the spacing between the N/A
conductors before the protection is applied is not
less than the values specified in Table 1 of IEC
60664-3
These values apply to functional, basic, N/A
supplementary and reinforced insulation ..............:
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
29.1 Clearances not less than the values specified in (see appended table) P
table 16, taking into account the rated impulse
voltage for the overvoltage categories of table 15,
unless ....................................................................:
for basic insulation and functional insulation they N/A
comply with the impulse voltage test of clause 14
However, if the distances are affected by wear, N/A
distortion, movement of the parts or during
assembly, the clearances for rated impulse
voltages of 1500V and above are increased by 0,5
mm and the impulse voltage test is not applicable
For appliances intended for use at altitudes N/A
exceeding 2 000 m, the clearances in Table 16 is
increased according to the relevant multiplier
values in Table A.2 of IEC 60664-1
Impulse voltage test is not applicable: P
- when the microenvironment is pollution degree 3, P
or
- for basic insulation of class 0 and class 01 N/A
appliances
- to appliances intended for use at altitudes N/A
exceeding 2 000 m
Appliances are in overvoltage category II P
A force of 2 N is applied to bare conductors, other N/A
than heating elements
A force of 30 N is applied to accessible surfaces P
29.1.1 Clearances of basic insulation withstand the P
overvoltages, taking into account the rated impulse
voltage
The values of table 16 or the impulse voltage test of Table 16 applied, P
clause 14 are applicable........................................: (see appended table)
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
29.1.3 Clearances of reinforced insulation not less than (see appended table) P
those specified for basic insulation in table 16,
using the next higher step for rated impulse voltage
...............................................................................:
For double insulation, with no intermediate N/A
conductive part between basic and supplementary
insulation, clearances are measured between live
parts and the accessible surface, and the insulation
system is treated as reinforced insulation
29.1.4 Clearances for functional insulation are the largest values determined from: P
- table 16 based on the rated impulse voltage ......: (see appended table) P
- table F.7a in IEC 60664-1, frequency not N/A
exceeding 30 kHz
- clause 4 of IEC 60664-4, frequency exceeding 30 N/A
kHz
If values of table 16 are largest, the impulse voltage N/A
test of clause 14 may be applied instead, unless
the microenvironment is pollution degree 3, or P
the distances can be affected by wear, distortion, N/A
movement of the parts or during assembly
However, clearances are not specified if the N/A
appliance complies with clause 19 with the
functional insulation short-circuited
Lacquered conductors of windings considered to be N/A
bare conductors
However, clearances at crossover points are not N/A
measured
Clearance between surfaces of PTC heating N/A
elements may be reduced to 1mm
29.1.5 Appliances having higher working voltages than rated voltage, clearances for basic N/A
insulation are the largest values determined from:
- table 16 based on the rated impulse voltage ......: N/A
- table F.7a in IEC 60664-1, frequency not N/A
exceeding 30 kHz
- clause 4 of IEC 60664-4, frequency exceeding 30 N/A
kHz
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
29.2.1 Creepage distances of basic insulation not less (see appended table) P
than specified in table 17.......................................:
However, if the working voltage is periodic and has N/A
a frequency exceeding 30 kHz, the creepage
distances are also determined from table 2 of IEC
60664-4, these values being used if exceeding the
values in table 17 ..................................................:
Except for pollution degree 1, corresponding N/A
creepage distance not less than the minimum
specified for the clearance in table 16, if the
clearance has been checked according to the test
of clause 14 ...........................................................:
29.2.2 Creepage distances of supplementary insulation at (see appended table) P
least those specified for basic insulation in table 17,
or ...........................................................................:
Table 2 of IEC 60664-4, as applicable ..................: N/A
29.2.3 Creepage distances of reinforced insulation at least (see appended table) P
double those specified for basic insulation in table
17, or .....................................................................:
Table 2 of IEC 60664-4, as applicable ..................: N/A
29.2.4 Creepage distances of functional insulation not less (see appended table) P
than specified in table 18.......................................:
However, if the working voltage is periodic and has N/A
a frequency exceeding 30 kHz, the creepage
distances are also determined from table 2 of IEC
60664-4, these values being used if exceeding the
values in table 18 ..................................................:
Creepage distances may be reduced if the N/A
appliance complies with clause 19 with the
functional insulation short-circuited
29.3 Supplementary and reinforced insulation have P
adequate thickness, or a sufficient number of
layers, to withstand the electrical stresses
Compliance checked: P
- by measurement, in accordance with 29.3.1, or P
- by an electric strength test in accordance with N/A
29.3.2, or
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
For appliances intending to be supplied from a detachable supply unit for the N/A
purposes of recharging the battery, the type reference of the detachable supply unit
is stated along with the following:
WARNING: For the purposes of recharging the N/A
battery, only use the detachable supply unit
provided with this appliance
If the symbol for detachable supply unit is used, its N/A
meaning is explained
7.15 Markings placed on the part of the appliance N/A
connected to the supply mains
The type reference of the detachable supply unit is N/A
placed in close proximity to the symbol
8.2 Appliances having batteries that according to the N/A
instruction may be replaced by the user need only
have basic insulation between live parts and the
inner surface of the battery compartment
If the appliance can be operated without batteries, N/A
double or reinforced insulation required
11.7 The battery is charged for the period stated in the N/A
instructions or 24 h ................................................:
11.8 Temperature rise of the battery surface does not N/A
exceed the limit in the battery manufacturer’s
specification; measured (K); limit (K) ....................:
If no limit specified, the temperature rise does not N/A
exceed 20 K; measured (K) ..................................:
19.1 Appliances subjected to tests of 19.B.101, 19.B.102 N/A
and 19.B.103
19.10 Not applicable N/A
19.B.101 Appliances supplied at rated voltage for 168 h, the N/A
battery being continually charged
19.B.102 For appliances having batteries that can be N/A
removed without the aid of a tool, short-circuit of
the terminals of the battery, the battery being fully
charged,
19.B.103 Appliances having batteries replaceable by the user N/A
supplied at rated voltage under normal operation
with the battery removed or in any position allowed
by the construction
19.13 The battery does not rupture or ignite N/A
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
e
TABLE R.1 – GENERAL FAULT/ERROR CONDITIONS
b, c
Component Fault/error Acceptable measures Definitions Document Document Ver-
a
reference reference dict
for applied for applied
measure test
1 CPU N/A
1.1
Registers Stuck at Functional test, or H.2.16.5
periodic self-test using either: H.2.16.6
- static memory test, or H.2.19.6
- word protection with H.2.19.8.2
single bit redundancy
1.2 VOID N/A
1.3 Stuck at Functional test, or H.2.16.5 N/A
Programme Periodic self-test, or H.2.16.6
counter
Independent time-slot H.2.18.10.4
monitoring, or
Logical monitoring of the H.2.18.10.2
programme sequence
2 No Functional test, or H.2.16.5 N/A
Interrupt interrupt or time-slot monitoring H.2.18.10.4
handling too
and frequent
execution interrupt
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
a)
For fault/error assessment, some components are divided into their sub-functions.
b)
For each sub-function in the table, the Table R.2 measure will cover the software fault/error.
c)
Where more than one measure is given for a sub-function, these are alternatives.
d)
To be divided as necessary by the manufacturer into sub-functions.
e)
Table R.1 is applied according to the requirements of R.1 to R.2.2.9 inclusive.
S ANNEX S (NORMATIVE)
BATTERY OPERATED APPLIANCES POWERED BY BATTERIES THAT ARE
NON-RECHARGEABLE OR NOT RECHARGED IN THE APPLIANCE
The following modifications to this standard are N/A
applicable for battery-operated appliances where
the batteries are either non-rechargeable (primary
batteries), or
rechargeable batteries (secondary batteries) that N/A
are not recharged in the appliance
5.8.1 If the supply terminals for the connection of the N/A
battery have no indication of polarity, the more
unfavourable polarity is applied
5.S.101 Appliances intended for use with a battery box are N/A
tested with the battery box supplied with the
appliance or with the battery box recommended in
the instructions
5.S.102 Appliances are tested as motor-operated N/A
appliances.
7.1 Appliances marked with the battery voltage (V) and N/A
the polarity of the terminals, unless ............ ..........:
the polarity is irrelevant N/A
Appliances also marked with: N/A
– name, trade mark or identification mark of the N/A
manufacturer or responsible vendor .......... ..........:
– model or type reference .......................... ..........: N/A
– IP number according to degree of protection N/A
against ingress of water, other than IPX0 .. ..........:
– type reference of battery or batteries ...... ..........: N/A
If relevant, the positive terminal is indicated by the N/A
symbol IEC 60417-5005 and the negative terminal
by the symbol IEC 60417-5006
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
Supplementary information:
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
Supplementary information:
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
Supplementary information:
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
Supplementary information:
Supplementary information:
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
temperature flames,
during the molten metal,
test of Clause or poisonous
11 is short- or
circuited. ignitable gas
in hazardous
amounts and
temperature
rises shall not
exceed the
values shown
in Table 9.
19.5 one end of Safe N/A N/A N/A N/A P
the element is continuous
connected to operation
the sheath of
the heating
element.
19.6 N/A N/A N/A N/A N/A N/A N/A
19.7 N/A N/A N/A N/A N/A N/A N/A
19.8 N/A N/A N/A N/A N/A N/A N/A
19.9 N/A N/A N/A N/A N/A N/A N/A
19.10 N/A N/A N/A N/A N/A N/A N/A
19.11.2 N/A N/A N/A N/A N/A N/A N/A
19.11.4.8 N/A N/A N/A N/A N/A N/A N/A
19.10X N/A N/A N/A N/A N/A N/A N/A
Supplementary information:
Supplementary information:
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
Supplementary information:
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
On-off switch Arcolectric .85.0.. 10(6)A 250V T125 IEC 61058 ENEC-
1E4 148185-02
.85.3..
Supplementary information: Certificate of heating element is set and comprise of thermostat, thermal
link, supply cord and plug that are given above list. These components are taken from VDE 125415
certificate.
1
) Provided evidence ensures the agreed level of compliance. See OD-CB2039.
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
1000 and 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0
1000 and 1250 6,4 10,0 14,2 20,0 25,0 28,0 32,0
1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0
1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0
1250 and 1600 8,4 12,6 18,0 25,0 32,0 36,0 40,0
1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0
1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0
1600 and 2000 11,2 16,0 22,0 32,0 40,0 44,0 50,0
2000 and 2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0
2000 and 2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0
2000 and 2500 15,0 20,0 28,0 40,0 50,0 56,0 64,0
2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0
2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0
>2500 and 3200 20,0 25,0 36,0 50,0 64,0 72,0 80,0
3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0
3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0
3200 and 4000 25,0 32,0 44,0 64,0 80,0 90,0 100,0
4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0
4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0
4000 and 5000 32,0 40,0 56,0 80,0 100,0 112,0 126,0
5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0
5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0
5000 and 6300 40,0 50,0 72,0 100,0 126,0 142,0 160,0
6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0
6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0
6300 and 8000 50,0 64,0 90,0 126,0 160,0 180,0 200,0
8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0
8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0
8000 and 10000 64,0 80,0 112,0 160,0 200,0 220,0 250,0
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0
10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0
10000 and 12500 80,0 100,0 142,0 200,0 250,0 280,0 320,0
Supplementary information:
)
* Material group IIIb is allowed if the working voltage does not exceed 50 V
)
** B = Basic insulation, S = Supplementary insulation, R = Reinforced insulation
1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0
1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0
2000 and 2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0
2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0
3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0
4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0
5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0
8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0
10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0
Supplementary information:
)
* Material group IIIb is allowed if the working voltage does not exceed 50 V
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
ZA ANNEX ZA (NORMATIVE)
SPECIAL NATIONAL CONDITIONS
Norway
19.5 The test is also applicable to appliances intended to N/A
be permanently connected to fixed wiring
Norway
22.2 The second paragraph of this subclause, dealing N/A
with single-phase, permanently connected class I
appliances having heating elements, is not
applicable due to the supply system
ZB ANNEX ZB (INFORMATIVE)
A-DEVIATIONS
Ireland
25.6 These regulations apply to all plugs for domestic N/A
use at a voltage of not less than 200 V and in
general allow only plugs complying with I.S.
401:1997, or equivalent, to be fitted to domestic
appliances
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
United Kingdom
25.6 These regulations apply to all plugs for domestic N/A
use at a voltage of not less than 200 V and in
general allow only plugs to BS 1363 to be fitted to
domestic appliances. It also allows plugs to BS
4573 and EN 50075 to be fitted to shavers and
toothbrushes
ZC ANNEX ZC (NORMATIVE)
NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR
CORRESPONDING EUROPEAN PUBLICATIONS
A list of referenced documents in this standard P
ZD ANNEX ZD (INFORMATIVE)
IEC and CENELEC CODE DESIGNATIONS FOR FLEXIBLE CORDS
A table with IEC and CENELEC code designations P
for flexible cords
ZE ANNEX ZE (INFORMATIVE)
SPECIFIC ADDITIONAL REQUIREMENTS FOR APPLIANCES AND MACHINES
INTENDED FOR COMMERCIAL USE
7.1 Business name and full address of the N/A
manufacturer and, where applicable, his authorized
representative ....................................................... :
Model or type reference ........................................ : N/A
Serial number, if any ............................................. : N/A
Production year N/A
Designation of the appliance ................................ : N/A
7.12 Instructions provided with the appliance so that the N/A
appliance can be used safely
The instructions contain at least the following information: N/A
- the business name and full address of the N/A
manufacturer and, where applicable, his authorized
representative
- model or type reference of the appliance as N/A
marked on the appliance itself, except for the serial
number
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
ZF ANNEX ZF (INFORMATIVE)
CRITERIA APPLIED FOR THE ALLOCATION OF PRODUCTS COVERED BY
STANDARDS IN THE EN 60335 SERIES UNDER LVD OR MD
List of standards under CENELEC/TC61 with the LVD P
allocation under the LVD (Low Voltage Directive) or
the MD (Machinery Directive) ............................... :
ZG ANNEX ZG (NORMATIVE)
UV APPLIANCES
The following modifications to this standard apply to N/A
appliances having UV emitters
This annex is not applicable to appliances covered N/A
by the scopes of IEC 60335-2-27, IEC 60335-2-59
or IEC 60335-2-109
7.12.ZG The instructions for appliances incorporating UVC N/A
emitters include the substance of the following:
WARNING — This appliance contains a UV
emitter. Do not stare at the light source
32 For appliances incorporating UV emitters the N/A
manufacturer delivers a declaration providing
evidence that the plastic material exposed to the
radiation is UV resistant
ZZ ANNEX ZZ (INFORMATIVE)
COVERAGE OF ESSENTIAL REQUIREMENTS OF EC DIRECTIVES
Description of the relation between this European LVD (2014/35/EU) was taken P
standard and the LVD (Low Voltage Directive, into consideration.
2006/95/EC) and the MD (Machinery Directive, A separate risk assessment
2006/42/EC) shall be performed.
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
Annex EN 62233:2008
Clause Requirement + Test Result - Remark Verdict
EMF- ELECTROMAGNETICS FIELDS
The tested product also complies with the requirements of EN 62233:2008
Limit ……………100% Measured max. :0.41% P
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
TRF No . IEC60335_2_43H
AB-0823-T
201700368TUR-
001
15.11.2017
Testing / measuring
Last Calibration Calibration due
Measurement / testing equipment / material used,
date date
(Equipment ID)
Variable Stabilized Power CHROMA 61612 Initial calibration Initial calibration
Source
Mono-Phase Power Meter YOKOGAWA WT310 12.2016 12.2017
Temperature Recorder YOKOGAWA MV2040 12.2016 12.2017
Hand-held Thermometer FLUKE 52-II 09.2017 09.2018
Hand-held Multimeter FLUKE 289 09.2017 09.2018
Force Gauge IMADA DS2-110 08.2017 08.2018
Electrical Safety Analyzer CHROMA 19032-P 09.2017 09.2018
Glow Wire Test Apparatus TESTING EUROPE T4-08 01.2017 01.2018
Test Nail TESTING EUROPE T5-76 09.2016 09.2019
Chronometer CASIO HS-80TW 01.2017 01.2018
Torque Screwdriver IMADA 09.2017 09.2018
Calliper MITUTOYO 573-635 09.2017 09.2018
Angle Meter MITUTOYO950-317 09.2017 09.2018
Probe B TESTING EUROPE T5-75 08.2016 09.2019
Probe 11 TESTING EUROPE T5-41 09.2016 09.2019
Probe 13 TESTING EUROPE T5-47 09.2016 09.2019
EMF Tester NARDA ELT-400 06.2016 06.2019
EMF Tester Probe NARDA 100cm2 06.2016 06.2019
Climatic Chamber ANGELANTONI DY 1200 01.2017 01.2018
Impact Hammer PTL F 22.50 05.2016 05.2019
Tracking Test Apparatus TESTING EUROPE T4-41A 04.2017 04.2018