INSTALLATION Pag. 16
GENERAL
- ATR-MIX series Metal enclosed units which are produced by our company,have been designed and tested to be used for all energy distribution
systems till 36 Kv
- Modular Metal Enclosed units appear as the optimal solution with their easiness of taking operation by means of their moduler structure and
with their modular appositi on characteristic for companies
- ATR-MIX series Metal enclosed unit are manufactured according to IEC Standards
- Optimal dimensions
- Long term technical solutions for various applications
- High level personnel safety
APPLICATIONS
- Manufacturing industry
- Secondary electricy distribution networks
- Shopping malls
- MV / LV distribution transformer substations
- Small size power plants
- Wind power plants
- Airports, hospitals, holiday villages
Enclosure of cubicle is 2 mm galvanized steel sheet. If desired al-zinc is also possible. No welding during the assembling of the structure.
SAFETY
- There is a survelliance window on the front cover of every cubicle to check inside the cubicle without opening the door / cover
- The door / cover of the accessible compartments is mechanically interlocked with the earthing switches
- High voltage indication system in each cubicle
STANDARDS
- Compliance with standards IEC 62271 - 200
- Classification; (according to IEC 62271 - 200 )
- Classification of service contunity: LSC 2A
STRUCTURES
1 Busbars compartment
3
2 Cable compartment
1 - Busbars compartment
Busbars compartment is located on the top of the cubicle. It contains the main busbars interconnecting cubicles and also:
- Tool based accessible compartment with regard to accessibility, (it means that is not possible to open the covers without using aproper tool)
- Withstand to internal arc
- IP 3X protection degree
2 - Cable compartment
Cable compartment is located on the bottom of the cubicle. It contains switching devices, metering transformers., HV fuses, earthing devices,
support insulators according to the functional type of the cubicle.
Incoming / outgoing MV cable connection of the cubicle is made in this compartment. The door has an inspection window. And also;
- Procedure based accessible compartment with regard to accessibility, (it means that it is possible to open the covers using a proper tool)
- Withstand to internal arc
- IP 3X protection degree
Rated voltage kV 12 24 36
Rated current
kA 16 16 16
kA 20 20 20
kA 25 25 25
Partitions class PI PI PI
Ambient temperature
- Minimum value °C -5 -5 -5
Type ATR - 01 Type ATR - 02 Type ATR - 03 Type ATR - 04 Type ATR - 05
Switch Unit Fuse Switch Combination Unit Switch Unit and Metering Circuit Breaker Unit Bus Tie - Riser Unit with Switch
Type ATR - 06 Type ATR - 07 Type ATR - 08 Type ATR - 09 Type ATR - 10
Bus Tie - Riser Unit Incoming Cable Connection Unit Bus Riser Unit Metering Unit Busbars Metering Unit
06 TYPICAL UNITS ATR-01
A
ATR - 01
A C
Standart equipment
RATED VOLTAGE KV 12 24 36
ATR - 02
A C
Standart equipment
RATED VOLTAGE KV 12 24 36
ATR - 03
A C
Standart equipment
RATED VOLTAGE KV 12 24 36
ATR - 04
B
A C
Standart equipment
RATED VOLTAGE KV 12 24 36
ATR - 05
B
A C
Standart equipment
RATED VOLTAGE KV 12 24 36
ATR - 06
B
A C
Standart equipment
RATED VOLTAGE KV 12 24 36
ATR - 07
A C
Standart equipment
RATED VOLTAGE KV 12 24 36
ATR - 08
A C
Standart equipment
RATED VOLTAGE KV 12 24 36
ATR - 09
A C
Standart equipment
RATED VOLTAGE KV 12 24 36
B
ATR - 10
A C
Standart equipment
RATED VOLTAGE KV 12 24 36
Tensione nominale fusibile 50 75 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000
Installation room
Fronte Fronte
Derating for altitude > 1000 meter over sea level (example)
- Installation altitude 2000 m
- Working at rated voltage of 7 kV rms
- Power frequency 20kV rms
- Lighting impulse 50 kVp
- Factor Ka = 1.13 (see graph)
Those factors can be calculated by the IEC 60071-2 Stds par.4.2.2 with the following equation:
Ka = e m (H.1000)/8150
Considering the above parameters, the switchgear must bear (on test at altitude zero i.e. on sea level):
-Power frequency: 20 x 1,13 = 22,6 kVrms
-Lighting impulse: 50 x 1,13 = 53,5 kVp.
From the above it is understood that for installations at altitude of 2000 meters over sea level , with working voltage of 7 kV, it is necessary
to foresee a switchgear with rated voltage of 12kV and with insulation lever at power frequency of 28kV rms with 60/75 kVp as lighting
impulse voltage.
Ka
1,50
m=1
1,40
1,30
1,20
1,10
H
1,10
2000
2500
3000
3500
4000
1000
1500
H meter altitude
m constant value equal to 1 for power frequency, lighting impulse and phase-phase
FILIALE TECNICO/COMMERCIALE - TECHNICAL/SALES MILAN BRANCH SEDE ESTERA SUD AMERICA - FOREIGN OFFICE SOUTH AMERICA
20066 Melzo (MI) Italia - Viale Svezia,7 Ave 7ma 6203, Miramar - Habana - CUBA
Tel. +39 02 9573 7811 - Fax +39 02 9573 2316 Tel.: +53 720 79077 Fax : +53 720 79079
email: sales@crtsgroup.com email : crts@crts.co.cu
SEDE LEGALE E AMMINISTRATIVA - HEADQUARTER AND ADMINISTRATIVE UFFICIO ASSOCIATO NORD AFRICA - ASSOCIATE OFFICE NORTH AFRICA
00193 Roma (RM) Italia - Via Crescenzio, 82 Immeuble cercle des bureaux 4 étage bureau N11 - centre Urbain nord Tunis - Tunisia
Tel. +39 06 687 4730 - Fax +39 02 9573 2316 Tel. 216 71 822 411 - Fax. +216 712 30825
email: info@crtsgroup.com email : tunis@crtsgroup.com