Condensate cleaners — installation guide for

SEP 120 ST - SEP 360 ST - SEP 900 ST


Check you have all the parts Fit the inlet block
Step Step to your chosen
needed to complete the con-
1 2 side using the
densate cleaner.
You should have 4 screws & screws supplied.
washers, a manifold block, 2 Extra blocks can
elbows and a straight push be purchased if
fitting, a length of tube, 1 required
large and 3 smaller blanking Step Fit the circular
plates, 2 spare sampler caps 3 blanking plug
and a spring steel strip.
into the opposite
SEP 900 ST has 2 spring
side of unit
steel strips.
Insert the Insert the metal retainer
Step Step
STERLING with its bent ends facing
4 filter, which 5 upwards.
is the white Slide it down until it makes
netting bag contact with the top of the
with the tied STERLING filter. Do not
top, pushing compress the filter.
it gently but For the larger SEP 900 ST,
firmly down two retainers are used at
base of the 90 degrees to each other
housing. for each filter set

Step Check that Sample


Step Step
the twist-off
6 7 8 cap is fitted to
the sample point.
Connect a reinforced
hose to the outlet
nipple, ensuring it
has unimpeded flow Outlet
to the foul drain. The
Insert the needle-felt Connect the inlet block to the outlet point is either moulded or a
filter with its inlet tube filter inlet tube using fittings separate fitting as shown depending
as shown supplied. upon the model.
Fill with water and check for any leaks
NOTES: Please ensure a steady down slope from the outlet point to the foul drain. Never discharge to
storm drain or surface water. Test outlet quality weekly using kit provided. Replace filters before outlet
cloudiness exceeds the ppm limit for your region.