Enable the Alert Type of LogTag

(Red) Record a to be used


reading Place to put
Indicator, when every / (Recommended) LogTag
reading interval
Below Above
Warehouse
Temperature (Pharmaceutical) +2 °C +25 °C 6 hours TRID30-7R
Room
Warehouse
Humidity (Pharmaceutical) 0% 65 % 6 hours HAXO-8
Room
Temperature (Non- TRID30-7R/ Warehouse
+2 °C +30 °C 6 hours
Pharmaceutical) TRIX-8 Room
Ice-lined
Temperature (Cold Chain) +2 °C +8 °C 30 minutes TRIX-8
Refrigerator
Temperature (Transportation) +2 °C +40 °C 15 minutes TRIX-8 Carton
Temperature
+2 °C +8 °C 15 minutes TRIX-8 Cold Box
(Cold Chain Transportation)

*Do Not Freeze*

This is not easy to set up standard range for use at all warehouse level where has different storage items
(medicine, voluminous items like syringe, condom & water for injection, lab reagent). We concern to use
as general instruction for all items.

According to Pharmacopeia, “the stability of a drug dosage form can be influenced by environmental
conditions of storage (temperature, light, air and humidity). Controlled room temperature delineates the
allowable tolerance  in storage circumstances at any location in supply chain. The common international
guideline for long-term stability specifies 25±2° at 60±5% relative humidity.” Ref: “USP29”

As per WHO Good Storage Practice Guideline, “Do not store over 30°C” means to keep the product
between +2 to +30°C and “Do not store over 25°C” means to keep the product between +2 to +25°C as
defined storage instructions. Ref: “WHO Guide to good storage practices for pharmaceuticals”.

And HIV Rapid Test Kits do not require cold chain storage (2-8°C), so please keep in warehouse room
with regular temperature monitoring.

Here is the different storage temperature. Our reference comes from supplier’s information.

Item Storage and Transportation


Uni-Gold HIV 1/2 rapid diagnostic Between 2 and 27ºC, protected against humidity and direct
test sunlight.
Determine HIV1/2 rapid diagnostic Between 2 and 30ºC, protected against humidity and direct
test sunlight.
STAT-PAK HIV1/2 rapid diagnostic Between 8 and 30ºC, protected against humidity and direct
test sunlight.