You are on page 1of 12

CURRICULUM VITAE

A.JOHN

E-Mail: johnbe26v@gmail.com
Mobile: 9047760389

MECHANICAL TECHNICIAN

OBJECTIVE:
To become competent professional through consistent updating of skills,
contributingsignificantly to the organization and to serve the organization with almost
commitment andDedication.

ACADEMIC QUALIFICATION:

DIPLOMA IN MECHANICAL ENGINEERING (2017)

NAME OF COMPANY DESIGNATION PERIOD LOCATION


Madina Group w.L.L
MECHANICAL TECHNICIAN From May 2021
to Aug 2022 Qatar

MECHANICAL TECHNICIAN From Jan 2020 Qatar


IRM OFFSHORE SERVICE to Mar 2021

CPCL – MANLAI PETROCHEMICAL MECHANICAL TECHNICIAN From June Nov Chennai


2018 to Dec 2019

MECHANICAL TECHNICIAN From Aug 2017 to MUMBAI


RELIANCE ENGINEERING MUMBAI sep 2018

WORK
EXPERIENCE – 5+ YEARS EXP IN OIL & GAS ( 2 YEARS GULF)

WORK EXPERIENCE – 5+ YEARS EXP (2 YEARS GULF)

ROTATING EQUIPMENTS:

Centrifugal Pumps:
 Worked with Single stage & multistage centrifugal pumps.
 Overhauling and Assembling experience in Centrifugal pumps. (Single/Multi Stage) 
Good Experience in installation, maintenance and troubleshooting of pumps.
 Having experience in Pump alignment (Rim and Face ,Reverse Indicator & Laser)
Centrifugal compressor:
 Replacing and repairing the Thrust Bearings, Journal Bearings, Labyrinth Seal, Dry
Gas Seal, Tertiary Seal and Honey Comb Seals and Checking its Clearance.
 Dismantling and assembling and troubleshooting experience on single and multistage
centrifugal compressors. Split & Barrel type.
Gear Boxes:
 Involved in prevents maintenance and Bearing changing, inspection its parts Gears
and Bearing, Pinions, Seals, Gaskets and Cases.
 To maintain the Shaft sleeve, Breathers, Lubrication, Temperature Backlash and Shaft
endplay.
Gas Turbine:
 Worked with Fuel Nozzles, Combustion Liners/Baskets, Flow Sleeves, Shroud Blocks,
Coupling Bolts, Doweling, Seals, Lock Plates.
 Replacing and Repairing Liquid Bypass/Throttle Valves, Gas Control/Throttle Valves,
Y strainers, Flow Dividers, Check Valves and Flexible Pig Tails.
 Maintenance works, System Pipe work and components are checked for signs of leaks,
All Gauges and Lubricating levels in the tank are assessed as a guide to component
condition, A running check of the operation of the DC Lube Oil pump may be
performed, Batteries should be boost charged.
 Experience in Installation, Troubleshooting, Maintenance and Shutdown activities.
Fin Fan:
 To take the various measurements Blade Angle, Bearing Thrust allowance, fit of fan
hub and Sheaves with Shaft, Alignment of Belt Drive.
 Do the Drive arrange methods Direct Couple with Motor Shaft and Belt Drive.
 Taking the Preventive Maintenance works Periodic Vibration Measurement,
Lubrication of Fan Bearings, Checking Belt Connections and measuring any Noisy
Operation.
Piping:
 Good knowledge in piping Isometric and P & ID Diagrams.
 Knowledge in Spool installation, hydro test, Reinstatement and Final Torque works.

Valves:
 Servicing, Pressure testing of various types of valves such as Gate valve, Globe
valve, Ball valve, Needle valve, Butterfly valve, Safety relief valve, pressure
relief valve and steam traps.
 Worked in overhauling & calibration of safety relief valves, general valves (Gate
valve, globe valve, ball valve, check valve etc.

Heat Exchangers:
 Involved maintenance activities of fixed, floating head type and U type bundle
heat exchangers.
 Hydro testing of shell test, tube test and doom test.
 Tube plugging and replacement, Hydro testing.

Other Static Equipment’s:


 Inspection of trays, down comers, drums, and supporting beams.
 Assembling and disassembling the trays and levelling the trays.
 Boiler accessories maintenance. Involved in cleaning, hydro testing, and burner
service and gun replacement.
 Pressure vessels, filters, strainers, and plant maintenance.
 Involved in shutdown maintenance of heat exchangers, Vessels, Towers,
Reactors, Tanks and Spading & de spading activities.

Safety Device:
H2S Safety, Fire safety, using crow can gas tester (CH 4, H2S), fire Extinguisher (Foam,
DCP & CO2 ;) using in fire classification, fusible plug operation, deluge valve operation,
fire-water pump operation. Breathing apparatus.

PERSONAL PROFILE:

Date of birth : 26/06/1999


Marital Status : Single
Nationality : Indian
Languages known : English, Hindi & Tamil
Permanent Address : kovilpatti, Thoothukudi Dist

Passport Details : ECNR


Passport number : S4959489
Date of Expiry : 27/08/2028
Place of Issue : Madurai

DECLARATION
I hereby declare that the above written particulars are true to the best of my knowledge and
belief. I assure to be responsible, self-motivated individual, devoted to the improvement of
the organization.

Date: Yours faithfully,


Place A.JOHN
NOV2sco/ Uah
1 JURTG REPUBIJ OF IND
$4959489
AROKKIARAJ
9594
AROKKIARAJ
JOHN
Tet/D.c ANITHA
TR INCAN 26/06/1999
KOVILPATTI, TAMIL NADU
T i.c o! SSuC
36C,VEERAVANCHI NAGAR,9TH STREET
MADURAI
An 28/08/2018
t e of lssuewre i fhf Date of Expary
27/08/2028
KOVILPATTI,THO0THUKUDI
PIN:628502,TAMIL NADU,INDIA
PINDAROKKIARAJ<<JOHN<<<<<<<<<<<<<<<<<<«<<<<
$4959489<6 I ND9906264M2 808277<<<<<<<<<<<<<<<6
MD2061442997318
O
Ministry of Health & Family Welfare
Government of India

Certificate for COVID-19 Vaccination


Issued in India by Ministry of Health & Family Welfare, Govt. of India

Certificate ID 98173639966

Beneficiary Details
Beneficiary Name / uaw6oTm6flul6on Oluurj John

Age 6JwgI 22

Gender / uTGbl60T LDD Male

ID Verified /60LWTOTE ET6O0T I Aadhaar # xXXXXXXX9442

Unique Health ID (UHID)

Beneficiary Reference ID 31544321539546

Vaccination Status/ BGUyA l6m6u Partially Vaccinated (1 Dose)

Vaccination Details
cOVISHIELD
Vaccine Name/ 56yuileT GlLuj
Vaccine Type /56uy au6m COVID-19 vaccine, non-replicating viral vector

Manufacturer/ 2-pUSSurOT Serum Institute of India

Dose Number/ LnGhO 6T60 1/2

Date of Dose/ GLT6n) 6JLpT6UULL GSS| 02 Sep 2021

Batch Number/ GuLLË ST6O0T 4121MCO68

Next Due Date/6s5Bgoas 85$ Between 25 Nov 2021 and 23 Dec 2021

Vaccinated By/ 56Lydlmu aupri6wauj Jeyajini

Vaccination At / SGUr¢l aJph &ULL gLD Chenbagaramanpudur BPHC, Kanyakumari,


Tamil Nadu

LD60T6n5lujL6OT
Together, India will defeat
cOVID-19

In case of any adverse events, kindly contact the nearest Public Health Center/
Healthcare Worker/District Immunization Office/State Helpline No. 1075

785b 1ljump ailm 1, 61 6DLILLA), BWOY Gleugi agsToLDUl gyjOTIOT olLing


Gr6nn Mbwb/ n ssluùupmofiyú uwlunorj / uomauLL 5GLIYLA aguau
Lmpblov25ol sT600T. 10758 OsTLjLy 0sno1OALu.

You might also like