Professional Documents
Culture Documents
SETTING THE
HUNDREDONEBENCHMARK
EARTH
TECHNOLOGY
YEAR ONE
LEGACYFOR THE INDUSTRY
FUTURE
ADVANCEMENT
OF INNOVATION
Country of origin
Wuxi China
Refrigerant
R134a
Capacity
187-371 TR
EXPERIENCE
HUNDRED YEAR
LEGACY OF INNOVATION
INNOVATION
TECHNOLOGY
ADVANCEMENT
EXCEEDING
SETTING THE SUSTAINABILITY
BENCHMARK FOR ONE EARTH ONE FUTURE
THE INDUSTRY
Experience - Our history,
starting from invention by 1883
1883 York introduced the first ice machine and cooling machine 1883 Warren Johnson invented first indoor electric thermostat, which opened a
brand-new industry of thermostat
1924 York established the branch company in China
1885 Johnson Electric Service Company was set up in Milwaukee, Wisconsin
1935 York introduced the first split air conditioner
1887 First investment dividend
1954 York launched the first full year operating air conditioner
1965 Johnson Service Company listed in New York Stock Exchange
1958 York launched the first centrifugal chiller
1974 Johnson Service Company changed to Johnson Controls
1979 York introduced the first VSD centrifugal chiller
1978 Acquisition of Globe-Union, business extended to Auto Power
1995 York established the factory in China
1985 Acquisition of Hoover Universal, business extended to Auto Seating
Nearly Serving
Customers in
2000
Locations Worldwide 150+
Countries
Proven by experience
Over 12.5 million kW of VSD screw compressors operating globally
More than 90,000 years of cumulative field experience
> 250,000
50,000 - 250,000
26,000 - 50,000
6,000 - 26,000
EXPERIENCE
HUNDRED YEAR
LEGACY OF INNOVATION
INNOVATION
TECHNOLOGY
ADVANCEMENT
EXCEEDING
SETTING THE SUSTAINABILITY
BENCHMARK FOR ONE EARTH ONE FUTURE
THE INDUSTRY
Innovation - Compressor, Heart of the chiller
Sysnoise analysis on internal cavity to prevent CFD analysis on compressor internal flow velocity and static pressure to reduce internal
acoustic resonance during compressor operation. pressure drop to minimum level and then to improve compressor efficiency.
Innovation - Compressor, Heart of the chiller
Fixed and Variable Vi Design Options to meet both excellent full load and part load efficiency
Extreme high full load and part load efficiency to meet domestic and overseas market needs.
VSD with Variable Vi Design to improve chiller IPLV by 34% over fixed speed product.
GT(VSD)
GT(Fix speed)
Innovation - Compressor, Heart of the chiller
Patented Dampening Structure design to reduce compressor discharge pulsation and noise
significantly
Improved
Original
Optimized
Innovation - High efficiency condenser
Integrated oil separator in the condenser utilizes double Counter flow sub-cooler design to reduce pressure drop and increase subcooler efficiency
gas inlet with discharge bend to reduce oil velocity to to provide lower liquid refrigerant temperature and higher sub-cooling
achieve multiple-stage oil separation. This enhances the
oil separation effectiveness and reduces the noise
t1
T1 T2
t2
逆流
Innovation - Smart controller
7-inch high definition Design for industrial Real time display of multiple chiller operating parameters
color standard Real time input of chiller controlling parameters via the touch-screen
The controller algorithm accurately adjust the slide valve position, refrigerant liquid level and VSD speed to provide the most optimal output according to
the real-world needs.
Real time monitoring and setting of critical operating parameters, such as the maximum and minimum value of the slide valve position, EXV opening and
motor RPM to prevent the machine from operating beyond the limit which could lead to shut off.
Provide more than 100 types of chiller self-diagnostic function for added security
Record up to 50 alarm status
1%
The YORK VSD also equipped with a set of unique compressor control algorithm to dynamically
monitor the position and speed of the rotor and to modulate the rotor operation such that the input
current can be optimized. This way the motor efficiency can be increased by at least 1%
EXPERIENCE
HUNDRED YEAR
LEGACY OF INNOVATION
INNOVATION
TECHNOLOGY
ADVANCEMENT
EXCEEDING
SETTING THE SUSTAINABILITY
BENCHMARK FOR ONE EARTH ONE FUTURE
THE INDUSTRY
Exceeding - Surpasses All Competition
6.68
6.64 6.60
6.56 6.50 6.47
6.35 6.3
6.45
YGWH
6.0 GB Level 1 - 2015
Trane RTHD PE
Carrier 30XW PE
Daikin PFSY-L1
YR HE
INNOVATION
TECHNOLOGY
ADVANCEMENT
EXCEEDING
SETTING THE SUSTAINABILITY
BENCHMARK FOR ONE EARTH ONE FUTURE
THE INDUSTRY
Sustainability - Helping customers to
maximize the LEED points
Helps You Achieve LEED® certification
80,032
75,387 75,049
70,745 9,286 $
10.63
Yearly operation cost
saving compared to 12%
10.12
Carrier 30XWV
38,321 9.76
36,506 34,869
8.62
33,155
5,166 $
6.38
Yearly operation cost
saving compared to 13%
5.94
6.01 Trane RTHD VSD
5.63
Part load operation cost Full load operation cost Chiller COP Chiller IPLV
Assumptions:Yearly 4000 cooling operation hours at electricity rate 0.14 $/kWh (Singapore rate),calculated cooling capacity 658 kW
Condition: AHRI standard condition
Data
Centers
Healthcare
Location:Wuxi, China
Refrigerant:R134a
Cooling Capacity:187-371 TR
Capacity (kW)