3053 Mahmoud Madkor st 2nd Floor i (1 Elaoerag city, Cairo MT or PT Inspection Report Phonertae nes aasnese Call phone: -20 1052703368 Ema: se@rigsotions com Websie: vnrigolutlons com ~IG SOLUTION ST a STS Te TT TTT Tgyptanlamtenanee Company EWC) Sonney scare cae aera ern cara LaBTOT et eeton | SoS GPC Trevor ie [06117022 ‘Specification ‘API ASTM ASME Customer Spec BJ Other \STM E709 | Edition: 2021 <5 BOB SPECECERPTL a [oar etree Wa ar etroaiwe [Wa a Tr 7 ipa aa ng Se aT Ecomentnes fart a oa oa Manufacturer [Parker nz (N/A ppray Details entrant “leoner pveloper far ovebete [27067005 Wa a enecirer Ia rm he [teu feet Crterto [7.618 Ibs INA INA [Expire Date N/A [Nia [Nia Fed Viet Do iste Foreen sted Sean Gre Coan atid obtion Detala contrast Frater esoaaea Femrosonscen — |WA [ven time wa Imanufacturer —[Chemerall _[themetall [WA [PeveloperApoiy INIA Peveloptime via Expire Dove [os/2025 16/2025 [Nia ‘Light intensity INIA avinc™ INIA BRAKE BAND (OTHER PARTS) OF DRAW WORK. Model:J¢ 21/11 . Drum Size : 42.1% 12.2 In Input HP: Description 603.5 HP . Date : 05/2008 Identification No_ DRAW WORK Serial Number : 08-0501 mel Visual inspection was carried out on the ( BODY ) of the above mentioned description as shown in Picture and found ( Accepted) ‘Sommer Magnetic Particle Inspection was carried out on (CRITICAL AREAS ) of the above ‘mentioned description as shown in Picture and found ( Accepted ) od Fou cncuson Magnetic Particles Inspection Was Carried Out And Found, free from surface cracks at time of inspection (accepted) arson moking th report ‘Name = Abdou Abdel Razek Parson authenticating this report Qualification : NDT, Lifting. Qc inspector Hamdy Geddawy ste: 09/11/2022 Form # RSERF-O7 -ISSUE 05 / Jan 2022