You are on page 1of 2

Slam-shut valves give you the peace of mind knowing that

customers and assets are protected

Protect your customers and assets from under and overprotection events while
meeting safety and regulatory requirements.

Overview Benefits
Slam-shut valves are designed to rapidly shut off the gas flow when • System Protection—Under-pressure and/or overpressure
the pipeline pressure exceeds or falls below predefined levels. protection of your downstream systems and equipment
Emerson offers both standalone slam-shuts and integral • Zero Emissions—Environmentally friendly with no leaking or
regulator/slam-shut combinations that utilize a common body venting to atmosphere
where the slam-shut is able to act independently of the regulator. • Positive Shutoff—ANSI/FCI Class VIII Bubble-tight shutoff to
downstream equipment and systems
Applications • Easy In-Line Maintenance—Internal parts can be inspected and
replaced without removing the body from the pipeline
• Transmission
• Reliability—Trip mechanism designed with accuracy and vibration
• Distribution resistance to avoid unintentional trips
• City Gate
• Commercial Service
• Industrial Service
• Residential Service
Slam-shut devices protect your system from under and
overpressure events

Slam-Shut Devices

VS100 Standalone Series Type OSE


• Medium and high capacity body sizes available • Overpressure and under-pressure protection
• Instantaneous response time • High shock and vibration resistance – two-stage
• Complies with the Pressure Equipment Directive tripping mechanism
(97/23/EC) Requirements • Maintains up to ±1% accuracy regardless of inlet
• Modular body construction pressure, flow rate and size of slam-shut
• Water tight for pit service to 10 ft / 3.0 m
• Remote activation alarm capability

Integral Slam-Shut Devices

CS804 Series Type EZL-OSX


• Includes the Type VSX8 Slam-shut • Two configurations: OPSO and OPSO/UPSO
module for both overpressure and • Manual intervention is required for reset
under-pressure protection meeting DOT requirements
• Can be installed in any position (spring • Can be installed in any position
case vent to be pointing downward) • Bubble-tight shut off
• Minimizes cost of ownership • Thoroughly tested, high accuracy and robust
• Simplified maintenance in design

Type EZH-OSX Type 299HV


• Type EZH with a Type OS2 slam-shut device • Small envelope because of the built-in pilot
for OPSO/UPSO and internal registration combined with a
• Eliminates nuisance and wasteful bleed gas Type VSX8 slam-shut
to atmosphere by utilizing a self-contained • Wide variety of applications – natural gas
control system distribution systems, furnaces, ovens, mixers
• Metal plug design deflects particles and • Economical, labor-saving installation
debris thereby providing long life in severe
service applications

Emerson Automation Solutions

Americas
T +1 800 558 5853 webadmin.regulators@emerson.com
T +1 972 548 3574
Fisher.com
Europe
T +39 051 419 0611 Facebook.com/EmersonAutomationSolutions

Asia Pacific LinkedIn.com/company/emerson-automation-solutions


T +65 6777 8211
Twitter.com/emr_automation
Middle East / Africa
T +971 4811 8100

D352830X012 © 2019 Emerson Process Management Regulator Technologies, Inc. All rights reserved. 05/19.
The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners.
Fisher™ is a mark owned by Fisher Controls International LLC, a business of Emerson Automation Solutions.

You might also like