Professional Documents
Culture Documents
C7
SCJ
REFER 'TYPICAL
1C
1C
C8
FTG/PILE DOWEL
DETAIL' (TYPICAL) BSF3 BSF3
C2
C1
1C
1C
PC1 OVER
BSF2
BSF2
BS
F3
C
-
SCJ
1C
C5
C
1C
4
BSF2
6
C1
0C
BS
F3
D
-
PC1 OVER
BSF2
5
C1
C3
1C
0C
SCJ
C6
1C
CJ
0C
C1
4
BSF2
B
SI
CJ -
PC
SCJ
1
DROP BSF2 ONTO
SCJ
C3
C2
C1
FTG BELOW
0C
0C
0C
A
-
RW1
C6
C4
C5
0C
0C
0C
SCJ SCJ
7C
0C
CJ
PC1
PC2 OVER
3
2
C1
C1
0C
0C
SCJ SCJ
J
SC
0
C9
C8
C1
PC
0C
0C
0C
1
RW1
1
C1
0C
BSF1
B O U N D A R Y RW1 RW1
REFER 'TYPICAL
FTG/PILE DOWEL
DETAIL' (TYPICAL)
BOUNDARY
600
WALL OVER WHERE
APPLICABLE
N28 SPACERS AT 1000 MAX CTS
BOUNDARY
200
1000 MAX
CONTIGUOUS PILING TO
6-N28 TOP SPECIALIST CONTRACTOR
270
N12 'L' BAR DRILLED AND CONTIGUOUS PILING TO
EPOXY 250mm INTO EVERY SPECIALIST CONTRACTOR
430
SKETCH 0.1
600
450 100
MIN
600
PC1
SHOTCRETE SL102 MESH,
40 COVER
1800 MAX
BOUNDARY
270
N12 'L' BAR DRILLED AND
EPOXY 250mm INTO EVERY
430
2ND PILE AT 600 MAX. CTS.
VERTICALLY. (TYPICAL)
6-N20 'Z' BARS,
N12-300 LIGS,
1000 COG
CONTIGUOUS PILING TO
SPECIALIST CONTRACTOR
RW1/RW2 (TYPICAL)
600
PC1
SKETCH 0.2
BOUNDARY
200 200
WALL DETAILS
AND REINF. AS
PER S-9 DRGS
PILECAP DETAILS
AS PER TYPICAL
PILECAP PC1 DETAIL
600
1 1
PC PC
600 600
WATER PROOFING TO
BUILDERS DETAILS
SKETCH A
BOUNDARY
200
WATERPROOFING TO
BUILDERS DETAILS
N12-400 Z BARS
REINF. AS
PER PLAN 500
100
200
200
N16-200 STARTER BARS
PILECAP DETAILS AS
PER TYPICAL
PILECAP PC1 DETAIL
1
PC
CONTIGUOUS PILING TO
SPECIALIST CONTRACTOR
SKETCH B
200
BOUNDARY
WALL DETAILS AND
REINF. AS PER S-9 DRGS
N12-400 Z BARS
REINF. AS
100
PER PLAN
200
200
DPM
500
PC
1
CONTIGUOUS PILING TO
SPECIALIST CONTRACTOR
450
SKETCH C
200
BOUNDARY
WALL DETAILS AND
REINF. AS PER S-9 DRGS
PILECAP DETAILS
AS PER TYPICAL
PILECAP PC1 DETAIL
PC
1
SHOTCRETE SL102 MESH,
40 COVER
CONTIGUOUS PILING TO
SPECIALIST CONTRACTOR
450 100
MIN
SKETCH D
LOCATION
CAP PC1 STEP
INDICATIVE PILE
-
-
F
E
PC2 PC2 PC1 PC1
0C
0C
PC1
C
C4
8 0C
C 1C
1C
16 80 STEP C7
C1
B O U N D A R Y
B O U N D A R Y
2CB8
CJ 2CB4
0C 0C 0C
C9 C1
2CB1
C5
-
G
80 STEP
80 STEP
2C
2C
C4
1C
2CB13
C6
1C
C2
CJ
2CB2
0C
C8
2CB3
C1
4
2CB12
2C 2C
C8 C 2 1C 80 STEP
80 STEP C4
PC1
2C
2CB9
-
H
2CB10
2CB7 C5 2CB11
2CB5
2CB6
1C
2C C5
C7 80 STEP 80 STEP
CJ
1C
C3
0C 0C
0C C1
2 0C
C2
C1
0 C6
2C
C 9
2CB19
2CB14 2CB17 2CB15
2C 2C
C1 C3 1C
0C 0C
6 C
C1 0C
1
C3
0C C7
C1
3
CJ
2CB16
PC1
HOLD
CJ
CJ
PC
1
2CB18
CJ
SC
J
BOUNDARY
FENCING AS PER
ARCH'L DRAWINGS
S-12 DRAWINGS
(VARIES)
6-N32 BARS
LEFT & RIGHT,
N12-200 LIGS
N16-200 BARS
300
600
2
PC
CONSTRUCTION JOINT
N16-200 BARS
300
SKETCH E
400
N12-100 LIGS
300
FENCING AS PER
ARCH'L DRAWINGS
4-N20 TOP & BTM
BEAM REINFORCEMENT
200 AS PER PLAN & BEAM
ELEVATIONS
X SECTION
2CB9 - SCALE 1:20
200
250
1
PC
PC
CONSTRUCTION
600 JOINT COLUMN REINFORCE
690 TBC
WITH ARCH'LS AND DETAILS AS
PER S-10 DRAWINGS
REINF. AS CONTINUE
PER A1 REINF. FULLY
0CC8
SKETCH F
4-N20 TOP & BTM
250
X SECTION
250
- SCALE 1:20
SKETCH G
EXTRA REINF.
AS PER PLAN
200
SKETCH H