You are on page 1of 4

8/7/22, 3:25 PM DP Type Closed Tank Level Transmitter Full Calculation Formula | Wet Leg

DP Type Closed Tank Level Transmitter Calculation


Formula | Wet Leg Formula
By EERameshkumar - September 10, 2021

Differential Pressure Transmitter Installation Formula | Wet Leg


Calculation Formula | L.R.V & U.R.V and  Span Value Calculation
Formula Full Details.

Example:-
In this Given Below Figure, the DP-Type Transmitter is fitted on the Water Stored tank .
The DP-Type Transmitter has Two Legs, HP Side Leg is Fitted on the Bottom of the tank &
LP Side Leg is Fitted on the Top of the Tank. The Total height of The tank is 750 mm, and
transmitter HP side Leg is fitted below the tank is 400 mm, the Specific gravity of Liquid of
Tank which is Connected to HP Side Leg of Transmitter is =1 sg, and Other LP Side Leg of
Transmitter  is Filled with Glycerin, Suppose glycerin Specific gravity is =0.8 sg. Calculate
the LRV & LRV values and also Calculate the Span values in the Transmitter.

GIVEN DATA:-

A to C Point Height L1=750 mm

C to B Point height L2=400 mm

Specific gravity of Liquid is SG1=1

Specific gravity of Glycerin is SG2=0.8

Calculate LRV, URV and Span Value of this Transmitter ?

Subscribe
1. First Calculate to Total
the my website
heightfor
ofthe Latest updates,
Transmitter whichnotifications
is Installedabout new
on the posts.
Tank ✕
X= L1 + Your
l2 = name
400 mm + 750 mm Your email SUBSCRIBE

https://eerameshkumar.com/dp-type-closed-tank-level-transmitter-calculation-formula-wet-leg-formula/ 1/4
8/7/22, 3:25 PM DP Type Closed Tank Level Transmitter Full Calculation Formula | Wet Leg

X= 1150 mm

( X= Total Height )

Watch This Full Videos:-

L.R.V calculation:-

Next Calculate at Zero Level ( Means when Liquid tank is Empty Condition )

Fig. 1

L.R.V = Pressure Acting on HP-Side – Pressure Acting on LP-Side

Pressure Acting on HP-Side is = L1*SG1    ……. (Eqn-1)

=400X1 = 400 mmH2o

Pressure Acting on LP Side = X*SG2  …….    ( Eqn-2)

= 1150*0.8 =920 mmH2o

Lets go to Repeat it L.R.V Calculation ( Lower Range Value )

LRV = Pressure Acting on HP-Side – Pressure Acting on LP-Side

Here Put Equation….(1) – Equation….(2) Formula

⇒ (L1*SG1) – (X*SG2)

⇒ 400*1 – 1150*0.8

= 400 mmH2o – 920 mmH2o

LRV = -520 mmH2o

Subscribe to my website for the Latest updates, notifications about new posts.
U.R.V calculation :- ✕
Your name Your email SUBSCRIBE

https://eerameshkumar.com/dp-type-closed-tank-level-transmitter-calculation-formula-wet-leg-formula/ 2/4
8/7/22, 3:25 PM DP Type Closed Tank Level Transmitter Full Calculation Formula | Wet Leg

Next Calculate at 100%  Level ( Means when Liquid tank is Filled Condition )

Fig. 2

U.R.V = Pressure Acting on HP-Side – Pressure Acting on LP-Side

Pressure Acting on HP-Side is = (L1+L2)*SG1    ……. (Eqn-1)

    ⇒ (400+750)*1 = 1150 mmH20

Pressure Acting on LP-Side is = X*SG2  ……..(Eqn-2)

    = 1150*0.8 =920 mmH2o

Lets go to Repeat it U.R.V Calculation ( Upper Range Value )

URV = Pressure Acting on HP-Side – Pressure Acting on LP-Side

Here Put Equation….(1) – Equation….(2) Formula

⇒ (L1+L2)*SG1 – X*SG2

= 1150 mmH20 – 920 mmH2o

    U.R.V = 230 mmH2o

SPAN Value calculation:-


Span = URV – LRV

=230-(-520) = 750 mmH2o

Span = 750 mmH2o

How to Testing RTD Sensor with Multimeter:-

Subscribe to my website for the Latest updates, notifications about new posts. ✕
Your name Your email SUBSCRIBE

https://eerameshkumar.com/dp-type-closed-tank-level-transmitter-calculation-formula-wet-leg-formula/ 3/4
8/7/22, 3:25 PM DP Type Closed Tank Level Transmitter Full Calculation Formula | Wet Leg

EERameshkumar
https://eerameshkumar.com

EERameshkumar is an Electrical as Well as Technical Knowledge Portal. On our portal we offer All Types of Technical
Study Material like -Video Courses on YouTube Channel, Pdf Files, Images, and Word file Documents Etc.
EERameshkumar is a 100% free website and it’s our Promise it will always free for Everyone. We are working on our all
Platforms Like ( Facebook, Twitter, Instagram & YouTube ) to provide the best quality Knowledge for all of you from any
electrical or Technical stream.





Subscribe to my website for the Latest updates, notifications about new posts. ✕
Your name Your email SUBSCRIBE

https://eerameshkumar.com/dp-type-closed-tank-level-transmitter-calculation-formula-wet-leg-formula/ 4/4

You might also like