SERIES: FTT20
UP TO 0.2% ACCURACY ' OT
HA R T ICATION PRO
TOCOL
INTRODUCTION
Indumart FTT20 series of Liquid Turbine Flow When in usage, the inlet and outlet pipes must be fully
Transmitters are accurate instruments for measuring filled with the liquids and the bubbles must be
flow rate and flow volume of low to medium viscosity entrained from the liquid (also no cavitation). The
liquids in a pipe and produce electrical signals (pulse or flow entering into the flowmeter must be without
current or both) proportional to the flow rate. These pulsation, therefore a minimum straight pipe length of
flowmeters are offered in various sizes and flow ranges at least 10 times of the internal diameter of the pipe
to suit both industrial, municipal and OEM applications. must be allowed for the inlet and at least 5 times of the
internal diameter of the pipe must be allowed for the
When liquid flows through the turbine housing of the outlet of the flow meter. As standard, straight runs
FTT20 flowmeter, it results in spinning of an internal and filter are included in the length for flowmeters with
rotor. As the rotor spins, an electrical signal is ½" thread. For other flowmeters with threaded
generated in the coil. This signal is then converted into connection, the straight runs are optional feature that,
engineering units (liters, cubic meters, gallons etc.) on if required, it must be included in the customer's order.
the local display.
The standard flow ranges are given in the table. If the
The instrument consists of two parts 1) flow sensor, 2) extended flow ranges or a special flowrate are
signal converter. The flow instrument can be supplied required, it must be specified in the order.
as the flow sensor only, without the converter/display,
or it can be supplied complete with the converter. The Optionally, the FTT20 transmitters may also have RS-
converter with LCD indications for the flow rate and 485 digital interface and HART communication.
flow volume is used for configuration of the flowmeter
parameters such as output scaling, total flow reset,
damping, etc.
Pulse RS485
Battery
2-Wire
3-wire
Model
PROCESS TEMPERATURE
120 °C Maximum 0
150 °C Maximum 1
XB
CX OPTION
None -
CB CD4MCu Rotor R
DX 1)
The models with output signals of 4..20 mA + Pulse (CP), 4..20 mA (CA)
DB and Pulse (PA) are all supplied with an aluminum enclosure. The model
with pulse output (PD) is supplied with a DIN connector.
HX 2)
Converter/display must be ordered for the unit with mA+pulse (CP)
HB output.
KX 3)
When ordering converters/display, please specify in your order the
KB measuring unit for the flow rate. Total flow will also be displayed in the
same volumetric unit. Converter/display must be ordered for the unit with
MX mA+pulse (CP) output.
MB 4)
Please mention NPT or BSP threads in your order. As standard, straight
runs and filter are included in the length for flowmeters with ½" thread. For
PX other flowmeters with threaded connection, the straight runs are optional
feature that must be included in the customer's order and then confirmed
PB by Indumart.
RX Example: FTT20CA-0CX0-040TD00 m3/h
RB 4...20 mA Output, 1% Accuracy, Dual Power 4..20 mA (2-wire)
SX Converter, Standard Flow Range (2 to 20 m3/h), 40 mm Dia.,
2" Threaded Connection, 304 SS Body, 120 °C Max. Temp.
SB