QCond
H2so4 to preheater
28.16 kW
Condensate Out
Hot Oil
67.52 kW
Evaporator
H2So4 to recycle
Water in
Water out
Stream Summary
Object Weak H2So4 Water out Water in H2so4 to preheater H2So4 to recycle H2So4 to Evaporator H2So4 to Cooler Condensate Out Conc. H2So4
Temperature 50 33.4674 25 166.833 166.833 56.6623 160 107.665 30 C
Pressure 1.033 1.033 1.033 1.033 1.033 1.033 1.033 1.2396 1.033 kgf/cm2
Mass Flow 300 3000 3000 282.291 282.291 300 282.291 17.7084 282.291 kg/h
Specific Enthalpy (Mixture) -1146.22 -2568.72 -2609.49 -701.009 -701.009 -1124.12 -724.489 132.969 -1157.67 kJ/kg
Molar Fraction (Liquid 1) / Water 0.25 1 1 0.01 0.01 0.25 0.01 0.920097 0.01
Molar Fraction (Liquid 1) / Sulfuric acid 0.75 0 0 0.990003 0.990003 0.75 0.990003 0.0799033 0.990003