You are on page 1of 1

R

Recycle

QCond
H2so4 to preheater
28.16 kW

Condensate Out

Weak H2So4 Pre Heater H2So4 to Evaporator

Hot Oil
67.52 kW
Evaporator
H2So4 to recycle

Water in

H2So4 to Cooler Conc. H2So4


Cooler

Water out

Stream Summary
Object Weak H2So4 Water out Water in H2so4 to preheater H2So4 to recycle H2So4 to Evaporator H2So4 to Cooler Condensate Out Conc. H2So4
Temperature 50 33.4674 25 166.833 166.833 56.6623 160 107.665 30 C
Pressure 1.033 1.033 1.033 1.033 1.033 1.033 1.033 1.2396 1.033 kgf/cm2
Mass Flow 300 3000 3000 282.291 282.291 300 282.291 17.7084 282.291 kg/h
Specific Enthalpy (Mixture) -1146.22 -2568.72 -2609.49 -701.009 -701.009 -1124.12 -724.489 132.969 -1157.67 kJ/kg
Molar Fraction (Liquid 1) / Water 0.25 1 1 0.01 0.01 0.25 0.01 0.920097 0.01
Molar Fraction (Liquid 1) / Sulfuric acid 0.75 0 0 0.990003 0.990003 0.75 0.990003 0.0799033 0.990003