OXYGEN CONCENTRATOR


Oxygen Concentrator
An oxygen concentrator is a device which concentrates the oxygen from
ambient air to supply an oxygen.

Oxygen concentrators were introduced in the mid-1970

Oxygen concentrators are alternative to using high-pressure oxygen cylinders


or liquid oxygen.

An oxygen concentrator operates with the help of electricity it receives


ambient air(21% oxygen) and it provides 90 to 90% of oxygen does not
require cylinder or bottle.

It is cost effective compare to conventional method of oxygen cylinder.

Application of Oxygen Concentrator


▪ Hospitals

▪ Home

▪ Oxygen therapy

▪ Pharmaceutical manufacturing

▪ Defense

Oxygen Concentrator in Hospitals

HOME CARE HOSPITAL O2 GAS PLANT

For Hospitals
Mass Production of O2

Installed In Hospital Compound

Cost : 50 L to 1 Cr
Equipment Unit & Accessories

Make: Respironics
Model: EverFlo

Equipment Unit & Accessories

Nasal Cannula Main Unit

Power Cable

Face Mask

Humidifier
Bottle
Equipment Unit & Accessories

Dimensions 58 cm x 38 cm x 24 cm

Weight 14 to 15 kg

Equipment Unit & Accessories

230 V AC Input
Equipment Unit & Accessories
Outlet
Pure Oxygen
90 to 96%

Power ON/OFF

Equipment Unit & Accessories

Air Intake
Air Inlet
Filter
Filter

To
Compressor
Equipment Unit & Accessories

Humidifier
Bottle
General Features
▪ Oxygen purity level (90-96%)

▪ Flow (Dual flow, single flow-5LPM)

▪ Sound Level (45 dB)

▪ Power rating (230VAC, 300W)

▪ Weight (14-15 Kg)

▪ Max Hours of operation

▪ Optional feature: Spo2


User Guidelines
▪ Oxygen concentrator should be placed away from sunlight, dust and in highly ventilated area

▪ Do not change the oxygen flow rate without consulting your doctor.

▪ Proper operation and regular maintenance should be carried out.

▪ Humidifier Bottle water should be replaced every 5 days.

▪ Primary filter cleaning/Replacement should be done within1000 hours of operation.

▪ Secondary filter replacement should be done within 3000 hours of operation.

▪ Cleaning and disinfection of accessories periodically.

▪ Backup Oxygen (Cylinders)is required for COPD Patients use during power failure.

▪ Improper maintenance result into the Respiratory infection.


Hardware - Pneumatic Diagram

Magnetic Valve
Compressor Air Intake Air
Filter

To Patient
Mainboard 90 to 96%
of Oxygen
Bacteria Filter
Pressure
1 Sieve Regulator
Beds
2 Flow
O2 Regulator
Tank

Sieve Bed Assembly

Hardware Diagram

Air

230V AC

90 to 96% O2

02
N2
Exhaust
Oxygen Concentrator - Hardware Assembly
Oxygen Concentrator - Hardware Assembly

Silicon Tubing
Oxygen Concentrator - Hardware Assembly

Compressor

Cooling Fan

200 W Electric Motor


40 to 50 psi

Oxygen Concentrator - Hardware Assembly

Capacitor
Oxygen Concentrator - Hardware Assembly

Microcontroller
Board

Power Switch
Oxygen Concentrator - Hardware Assembly

Zeolite Powder

Sieve Bed

Zeolite
Granules
Oxygen Concentrator - Hardware Assembly

Solenoid Value

Four Way Value


1.N2 Adsorption
Tank
2.N2 Adsorption
Tank
3.Oxygen Tank
4.Purge Tank

Maintenance Check
▪ Oxygen purity Level is verified with help of Oxygen

Analyzer(90 to 96%).

▪ Oxygen Concentrator outlet Pressure is verified with the

help of Pressure Gauge.


Maintenance Check
▪ Oxygen purity Level is verified with help of Oxygen

Analyzer(90 to 96%).

▪ Oxygen Concentrator outlet Pressure is verified with the help

of Pressure Gauge.

▪ Flow Meter Damage and Leakage Can be analyzed with

the help of Pressure Gauge.


Maintenance Check
▪ Oxygen purity Level is verified with help of Oxygen

Analyzer(90 to 96%).

▪ Oxygen Concentrator outlet Pressure is verified with the help

of Pressure Gauge.

▪ Flow Meter Damage and Leakage Can be analyzed with the

help of Pressure Gauge.

▪ Sieve Bed Leakage & Replacement can be verified during

Annual Maintenance.