You are on page 1of 4

/

Appendix 2 - Geared motor 5. Edition V301105002 Page 1

Operating and Maintenance Instructions


For geared motor

Index of Contents
Page
1 Maintenance of the gearing 1
1.1 Maintenance 1
1.2 Oi l change 2
2 Table 1 - lubricant quantities for spur gearing 2
3 Table 2 - l ubricant lYPES for spur gearing 2
4 Table 3 - technical data 3
5 Maintenance of the motor 3
5.1 Maintenance 3
5.2 Bearings 3
6 Technical drawing of motor 3
7 Technical drawing of spur gearing 4

1 Maintenance of the gearing


1.1 Maintenance
The gearing is largely maintenance-free. All gearing is supplied by us filled with oil and
lubricant and ready for use. Check this by carefully loosening the oil outlet screw; oil
should leak immediately.
See Table 1 for the prescribed oil and lubricant filling quantities. A thin film of grease may
form on the shaft and ventilation valve during Initial operation; this is quite normal.

IMPORTANT
The gearing must be installed as prescribed.
Make certain the self-ventilation works perfectly, i.e. coating air inlets and outlets
must be unhindered.

WARNING!
Maintenance and repair Is only allowed by qualified stuff.
Remark:
• The warning risk mentioned in our RWO Oily Water Separator - operating
manual, see point 1.1 ; 1.2 and 1.5
• The underlying regulations for prevention of accidents.
• The professional using of tools and lifting machines.

RWO Abwassertecnnik GmbH, Bremen Issued: 30.11.99


Appendix 2 - Geared motor 5. Edition V301105002 Page 2

1.2 Oil change


The lubricant must be changed after about 10,000 operating hours or three years at the
latest. Open up and clean the gearing and check aJi parts subject to wear ;replace the
shaft sealing rings as a precaution. Clean aJi sealing flanges before re-assembling and re-
seal with a plastic sealant (e.g. DiTko). FiJI with lubricant per Table 1 according to
installation.

WARNING!
Do not touch the rotating shaft in the stuffing box area as this may cause serious
injury to the fingers.

IMPORTANT
Never mix mineral and synthetic oils.

2 Table 1 - lubricant types for spur gearing


Oily water separator Skit S
50 Hz Net - frequency 0,1 0,25 0,5 1,0 1,5 2,5 5,0 10,0
Geared motor Type ceoo ceoo SK01 SK01 ~ SK.20 CSl CS2

~
Motor Type (non gearing) SOU6 1" '::"d'l;
Oil filling quantity (liters) 0.2 0,2 0,3 0,3 ]I 0,5 0,5

Oily water separator Skit S


60 Hz Net - frequency 0,1 0,25 0,5 1,0 1,5 2,5 5,0 10,0
Geared motor Type ceoo CSOO SK01 SK01 SK20 CSl CS2
Motor Type (non gearing) ::::. aous
Oil filling quantity (liters) 0,2 0,2 0,3 iii 0,3 0,5 0,5 0,7

3 Table 2 - lubricant types for spur gearing


Oil base ARAL BP GASTROL ESSO MOBIL iSHELL TEXACO

Temperature range EP - Gearing oil DIN 51 502

Mineral oil Oegol Energol Alpha Spartan !M0bilgear Omala Meropa


BG 320 GP-XP SP 320 EP320 632 320 320
·10 C - +50 C 320
Synthetic oil Oegol Energol Alpha Umlauf61 Glygoyle Tivela Synlube
GS220 SG-XP Syn.T220 8220 30 OilWe CLP 220
·30 C - 130 C
320
1. Mineral gearing oils are high-quality lubricants permitting service intervals up to 10,000
operating hours.

ImRortant
Never mix synthetic and mineral oils.

4 Table 3; driving data's


Oily water separator Skit S 0,1 0,25 0,5 1,0 1,5 2,5 5,0 10,0
Capacity kW 0,25 0,25 0,55 0,55 0,55 0,75 1,5 2.2
Pump rotary frequency min. -, 2BO 630 610 1130 920 740 795 780

RWO Abwassertechnik GmbH, Bremen Issued: 30.11.99


Appendix 2 • Geared motor 5. Edition V301105002 Page 3

5 Maintenance of the driving motor


5.1 Maintenance
The motor is nearly maintenance free. All drivings are filled with lubricant for application.

IMPORTANTI
Pay attention to the perfect self cooling of the air regulation, inlet and outlet of the
coating air must be unhindered.

5.2 Motor bearings


The motor bearings have to be changed usually after 20.000 working hours, but latest
after 3 year working hours.

WARNING!
Maintenance and repair is only allowed by qualified stuff.
Remark:
• The warning risk mentioned in our RWO Oily Water Separator - operating
manual , see point 1.1; 1.2 and 1.5
• The underlying regulations for prevention of accidents.
• The professional using of tools and lifting machines.

6 Technical drawing of motor

I
I

I )

t
RWO
_ • ..,rloc''" ;~

2820 tBr.m.n
- • ••- .- -- - t1~t:~..,·otoo"

- 92C053b
SKIT /S

RWO Abwassertechnik GmbH, Bremen Issued: 30.11.99


Appendix 2 - Geared motor 5. Edition V30 1105002 Page 4

7 Technical drawing of spur gearing

RWO
Abwassertechnik
2 8 2 0 1 Bremen

RWO Abwassertechnik GmbH, Bremen Issued: 30.11.99